Original sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking (all, by stage)
References: 106 extracted, 0 linked to papers
CKC Laboratories, Inc. Radio Frequency Electromagnetic Exposure Statement Of Compliance (January 2009)
CKC Laboratories, Inc. Addendum to L-3 Communications Safeview Inc. Test Report Ets07-009a for the Safescout Or Provision: ETSI EN 301 489-3 V1.4.1 (2002-08) Testing (Excerpt)
ADMINISTRATION: Report of Measurements and Assessment for Potential Electromagnetic Interference Effects on Personal Medical Electronic Devices from Exposure to Emissions from the L3 Provision Millimeter Wave Advanced Imaging Technology (AIT) Security System April 4, 2011
IEEE Std C95.1-2005: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. Institute of Electrical and Electronics Engineers 19 April 2006.
ICNIRP: Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz). Health Physics 1998; 74 (4): 494-522.
IEC 60601-1-2: 2007: Medical electrical equipment — Part 1-2: General requirements for basic safety and essential performance — Collateral standard: Electromagnetic compatibility — Requirements and tests. International Electrotechnical Commission March 2007.
ANSI/AAMI PC69:2007: Active implantable medical devices—Electromagnetic compatibility—EMC test protocols for implantable cardiac pacemakers and implantable cardioverter defibrillators. Association for the Advancement of Medical Instrumentation 2007.
ANSI/AAMI/ISO 14708-3 2008: American National Standard for Implants for Surgery – Active implantable Medical Devices – Part 3: Implantable Neurostimulators. Association for the Advancement of Medical Instrumentation 2008.
BS EN ISO 14971:2009: Medical devices — Application of risk management to medical devices. BSI British Standards 2009.
Hayes D, Wang P, Reynolds D, et al. Interference with cardiac pacemakers by cellular telephones. New England Journal of Medicine 1997; 21:1473-1479. Kanda M and Orr D. Near-Field Gain of a Horn and an Open-Ended Waveguide: Comparison between Theory and Experiment. IEEE Transactions on Antennas and Propagation 1987; 35 (1): 33-40.
Laurent A, Mistretta F, Bottigioli D, et al. Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines. Vaccine 2007; 25: 64236430. 10. Communications with Brian Lewis, M.D., Cardiologist, PDLB, Division of Cardiovascular Devices, Office of Device Evaluation, Center for Radiological Devices and Health, U S Food and Drug Administration.
11. BS EN ISO 7350-2: Basic human body measurements for technological design. BSI British Standards 2010.
FOR PUBLIC RELEASE CKC Laboratories, Inc. Radio Frequency Electromagnetic Exposure Statement Of Compliance (January 2009)
FOR PUBLIC RELEASE CKC Laboratories, Inc. Addendum to L-3 Communications Safeview Inc. Test Report Ets07-009a for the Safescout Or Provision: ETSI EN 301 489-3 V1.4.1 (2002-08) Testing (Excerpt)
EMC International Services: Radiated Emissions Testing and Power Density Calculations June 26, 2005
Safeview, Inc. Suite 110 469 El Camino Real Santa Clara, CA 95050 Subject: Radiated Emissions Testing and Power Density Calculation Dear Mr. , This letter provides details on a power density calculation that is based on a field strength measurement taken on the Guardian 100 system in our 10 meter semi-anechoic chamber on April 25, 2005. The unit under test was configured to transmit a continuous wave signal (sweeping stopped) at 26.378 GHz. A field strength of 93.67 dBµV/m was measured from a distance of 2.5 m from the unit. Converting this field strength into µV/m we have: Peak Field Strength (µV/meter) = 10field strength in dBµV /20 = 4.83 x 104 µV/meter = 4.83 x 10-2 volts/meter The theoretical equivalent isotropic radiated power (EIRP) of the unit under test is given by the formula:
EIRP (dBm) = 10 Log (4.86 x 10-4 Watts) = -3.14 dBm This represents the theoretical transmit power of the unit under test in terms of a point (isotropic) source. June 24, 2005 Page 2 When the unit under test operates as intended (with the sweeping not stopped), the transmitter sweeps from 24.25 to 30 GHz on one antenna. After this sweep is done, the next antenna in the array is swept. This process repeats until all antennas in the array have been swept. Due to the sweeping and also the spatial variance of transmitting from different antennas, a duty cycle figure can be calculated to determine how often transmission occurs at any one given frequency and at any one point in space. The following calculations show the duty cycle correction: Duty Cycle calculation: 1. Duty Cycle (frequency ramp) Frequency bandwidth = 24.25-30 GHz = 5750 MHz Sweep rate = 1.1MHz/ns
Averbeck D. Non-targeted effects as a paradigm breaking evidence. Mutat Res 2010; 687:7-12.
Becker J, Zankl M, Fill U and Hoeschen C 2007 About Katja, a virtual human phantom of a 24-week pregnant woman 7th International Scientific Conference SATERRA "Human and Environment" (Mittweida, Germany) vol 3) eds L Otto and H Exner (Hochschule Mittweida (FH)) p 5-7
Becker J, Zankl M, Fill U and Hoeschen C 2008 Katja — the 24th week of virtual pregnancy for dosimetric calculations Pol J Med Phys Eng. 14 13-9
BEIR. Health risks from exposure to low levels of ionizing radiation: Biological Effects of Ionising Radiation (BEIR) Committee report VII, phase 2; 2006. Berrington de Gonzáles A, Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 2004; 363:345-51. Berrington de Gonzales A, Curtis RE, Fry SF, et al. Proportion of second cancers attributable to radiotherapy treatment in adults. Lancet Oncol 2011;12:353-60
Brenner DJ. Are x-ray backscatter scanners safe for airport passenger screening? For most individuals, probably yes, but a billion scans per year raises long-term public health concerns. Radiology 2011; 259:6-10.
Cardis E, Krewski D, Boniol M, Drozdovitch V, Darby SC, Gilbert ES, et al. Estimates of the cancer burden in Europe from radioactive fallout from the Chernobyl accident. Int J Cancer 2006; 119:1224-35.
Daniels RD, Schubauer-Berigan MK. A meta-analysis of leukemia risk from protracted exposure to low-dose gamma radiation. Occup Environ Med 2011; 68:457-64.
Goodhead DT. New radiobiological, radiation risk and radiation protection paradigms. Mutat Res 2010; 687:13-6.
Grudzenski S, Raths A, Conrad S, Rübe CE, Löbrich M. Inducible response required for repair of low-dose radiation damage in human fibroblasts. Proc Natl Acad Sci U S A 2010; 107:14205-10.
Hammer GP, Seidenbusch MC, Regulla DF, Spix C, Zeeb H, Schneider K, et al. Childhood cancer risk from conventional radiographic examinations for selected referral criteria: results from a large cohort study. AJR Am J Roentgenol 2011; 197:217-23.
Hill MA. The variation in biological effectiveness of X-rays and gamma rays with energy. Radiat Prot Dosimetry 2004; 112:471-81.
Hunter N, Muirhead CR. Review of relative biological effectiveness dependence on linear energy transfer for low-LET radiations. J Radiol Prot 2009; 29:5-21.
ICRP. Recommendations of the ICRP. International Protection (ICRP) Publication 26. Ann ICRP 1977; 1:3. Commission Radiological
ICRP. Recommendations of the International Commission on Radiological Protection. International Commission on Radiological Protection (ICRP) Publication 60. Ann ICRP 1991; 21:1-3.
ICRP. Genetic Susceptibility to Cancer. ICRP Publication 79. Ann ICRP 1998; 28:1-2.
ICRP. Adult reference computational phantoms International Commission on Radiological Protection (ICRP) Publication 110. Ann ICRP 2009; 39:2.
ICRP. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103 (Users Edition). Ann ICRP 2007; 37:2-4.
ICRP. Draft report: Early and late effects of radiation in normal tissues and organs: threshold doses for tissue reactions and other non-cancer effects of radiation in a radiation protection context. Ann ICRP January 20, 2011; ref 4844-6029-7736.
Jacob P, Ruhm W, Walsh L, et al. Is cancer risk of radiation workers larger than expected? Occup Environ Med 2009;66:789-796
Kendall G, Little MP, Wakeford R. Numbers and proportions of leukemias in young people and adults induced by radiation of natural origin. Leuk Res 2011; 35:1039-43.
Leatherbarrow EL, Harper JV, Cucinotta FA, O'Neill P. Induction and quantification of gamma-H2AX foci following low and high LET-irradiation. Int J Radiat Biol 2006; 82:1118. Löbrich M, Rief N, Kühne M, Heckmann M, Fleckenstein J, Rübe C, et al. In vivo formation and repair of DNA double-strand breaks after computed tomography examinations. Proc Natl Acad Sci U S A 2005; 102:8984-9.
Maddams J, Parkin DM, Darby SC. The cancer burden in the United Kingdom in 2007 due to radiotherapy. Int J Cancer 2011 ;129 :2885-93
Munley MT, Moore JE, Walb MC, Isom SP, Olson JD, Zora JG, et al. Cancer-prone mice expressing the Ki-rasG12C gene show increased lung carcinogenesis after CT screening exposures. Radiat Res 2011; 176:842-48.
Nakano M, Kodama Y, Ohtaki K, Nakashima E, Niwa O, Toyoshima M, et al. Chromosome aberrations do not persist in the lymphocytes or bone marrow cells of mice irradiated in utero or soon after birth. Radiat Res 2007; 167:693-702.
NCRP. Report No. 91 – Limitation of exposure to ionizing radiation. National Council on Radiation Protection and Measurements (NCRP); 1987 (this report has been superseded by NCRP Report No. 116).
NCRP. Report No. 116 – Limitation of exposure to ionizing radiation. National Council on Radiation Protection and Measurements (NCRP); 1993.
NCRP. Commentary No. 16 – Screening of humans for security purposes using ionizing radiation scanning systems. National Council on Radiation Protection and Measurements (NCRP); 2003.
Pazzaglia S, Pasquali E, Tanori M, Mancuso M, Leonardi S, di Majo V, et al. Physical, heritable and age-related factors as modifiers of radiation cancer risk in patched heterozygous mice. Int J Radiat Oncol Biol Phys 2009; 73:1203-10.
Preston DL, Ron E, Tokuoka S et al. Solid cancer incidence in atomic bomb survivors: 1958-1998.Radiat Res 2007;168:1-64
Rajaraman P, Simpson J, Neta G, Berrington de Gonzales A, Ansell P, Linet MS, et al. Early life exposure to diagnostic radiation and ultrasound scans and risk of childhood cancer: case-control study. BMJ 2011; 342:d472.
Ray JG, Schull MJ, Urquia ML, You JJ, Guttmann A, Vermeulen MJ. Major radiodiagnostic imaging in pregnancy and the risk of childhood malignancy: a population-based cohort study in Ontario. PLoS Med 2010; 7:e1000337.
Rez P, Metzger RL, Mossman KL. The dose from Compton backscatter screening. Radiat Prot Dosimetry 2011; 145:75-81.
Rothkamm K, Löbrich M. Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses. Proc Natl Acad Sci U S A 2003; 100:5057-62.