Official Proceedings of the 2014 International Water Conference DCN SGE01067.A01
Other documents for the same rulemaking (all, by stage)
References
Presser, T. (1994), “The Kesterson Effect”, Environmental Management, Vol.18, Issue 3, pp. 437-454.
Meng, X.; Bang, S.; Korfiatis, G. P.; Water Res. 2002, 36, 3867.
Report, El Segundo, California, USA, 1992.
WSPA; Selenium Removal Technology Study: Project Final Report, Western States Petroleum Association, Sacramento, California, USA, 1995.
Water, North American Metals Council, 2010. Water Environment Federation (WEF), Overview of Selenium Issues in Industrial Wastewater Discharges – Technical Practice Update, 2010.
Hansen, D.; Duda, P.; Zayed, A.; Terry, N. (1998) Selenium Removal by Constructed Wetlands: Role of Biological Volatilization. Environ. Sci. Technol., 32 (5), 591– 597. <<Back>> <<Next>>
Dukes, S (2014). Reactive Iron Media – An Enhanced Zero Valent Iron Process for Metals and Metalloid Removal from Water and Wastewater. (IWC 14-58). Meng X (2002). Removal of Selenocyanate from Water Using Elemental Iron. Water
Research, 36, 3867. Sandy, T (2010). Review of Available Technologies for the Removal of Selenium from Water. Prepared for the North American Metals Council, copyright by CH2MHill.
Shamas, J (2009). Technologies and Strategies for the Treatment of Selenium as a Micronutrient in Industrial Wastewater. Water and Environment Federation, 423438.
Twidwell, L (1999). Potential Technologies for Removing Selenium from Process and Mine Wastewater. Montana Tech, University of Montana. Figures 1, 2 and 4 used with the kind permission of the Texas A&M University System. <<Back>> <<Next>>
Modern Industrial Boilers, (1994), The American Society of Mechanical Engineers.
Ed. (2011). The Nalco Guide to Boiler Failure
Port, R. D. and Herro, H. M., (1991). The Nalco Guide to Boiler Failure Analysis, New York,
Godfrey, M. R., Chen T.-Y., (1995) “Monitoring corrosion in boiler systems with colorimetric tests for ferrous and total iron,” Corrosion, 51(10), 797-804.
Godfrey, M. R., (2000) “On-line determination of corrosion products in steam generating systems,” Corrosion/2000, paper no. 00663, (Houston TX: NACE International, 2000) <<Back>> <<Next>>
API RP 11T (1994), Recommended Practice for Installation and Operation of Wet Steam Generators, 2
K. (2007), Solution Mining in Salt Deposits Outline of recent development trends, AGH University of Science and Technology Press, Krakow.
Kobylka, L., Hosseini, A. E., Perdicakis, B. (2013), A Water Toolbox to Optimize SAGD Water Recycling
Longshore, D. R. (Fall 2012), Salt Caverns for the Purpose of Waste Disposal, Solution Mining Research
C. (2012), Common Practices – Gas Cavern Site Characterization, Design, Construction,
B. (2012), Silicate Deposit Control in Steam-Assisted Gravity Drainage (SAGD) and Produced Water Applications, International Water Conference, IWC 12-40.
P. (2010), Method and System Generating Steam in Oil Industry, Canadian Patent, CA 2621991.
Suggett, J. and Wasylyk, M. (2011), OTSG Serial Connection to Blowdown Outputs from OTSG Systems, Canadian Patent, CA 2641866.
Sun, A., Giesbrecht, G. and Berruti, A. (2014), Increasing OTSG Steam Quality to 90% while Operating on WLS Treated BFW, COSIA Oil Sands Water Conference.
Sun, S. and Wasylyk, M. (2014), Push the Boiler to the Limit – Steam Quality, COSIA Oil Sands Water Conference.
Sun, S. and Wasylyk, M. (2011), An Innovative Solution to SAGD Blowdown Water – Blowdown Boiler
Technology, Susan Sun, Mike Wasylyk. International Water Conference, IWC 11-39. Van Doorn, E. J. and Belanger R. (2012), Silicate Scale Inhibitor Use in Once-Through Steam Generators in the SAGD Industry, International Water Conference, IWC 12-39.
Weagle, G. (2013), Forensic Analysis and Interpretation of Once Through Steam Generator (OTSG) deposits can Assist in System Operational Improvements”, International Water Conference, IWC 13-56. <<Back>> <<Next>>
D. (1980). The Solubility of Oxygen in Brines from 0 to 300 °C. Industrial & Engineering Chemistry Process Design and Development, 19(2), 300-305 . doi:10.1021/i260074a018 • Heaton, P., Lynn Lord, H., & Hay, J. (2014). Thermal Water Chemical Analysis. World Heavy Oil Congress, WHOC14-152. New Orleans, LA. USA • Standard Methods for the Examination of Water and Wastewater, 22nd Edition, 2005. • YSI Incorporated. (2014, 09 08). Luminescent-Based Detection Methods for Dissolved Oxygen. Retrieved from www.ysi.com/weknowDO: http://www.ysi.com/media/pdfs/NB7US-EPA-OpticalDO-Status.pdf <<Back>> <<Next>>
ASME PANEL SESSION - 2014 Melonie Myszczyszyn, Canadian Natural Resources, LTD: We’ll get started with our discussion session. If you have a question, this is the time to ask it because all the experts are here, as well as other operators and people that we can interact with. When you are asking questions, please give your name and who you are with. This will all be transcribed so that everyone can have access to these questions and answers after this session is done, so it’s very important you give your name and your affiliation. I’ve been very happy to be here today as your session chair with the ASME session. I’ve been working on this Produced Water consensus document for the last 6 years. I’ve come from the field with Canadian Natural Resources at Wolf Lake and Primrose and before that with Amoco. I’ve been able to experience a lot of these boiler failures firsthand and had to fix a lot of different OTSGs [once through steam generator] and also a HRSG [heat recovery steam generator] unit that we have at Primrose. So it’s near and dear to my heart that we start sharing this information and start fixing these issues before they happen to everyone else and that’s why I’m here. And then I’ll introduce Ivan Morales who will be leading our discussion today. Ivan has been working in the water treatment industry for the last 18 years. He worked 12 years for Nalco in
Venezuela, Mexico and Canada, 4 years for MEG Energy, and since June 2013 he’s been working for Devon Energy Canada. His current position is Water Operations Specialist, Lead Water Engineering Specialist. He’s been working in the SAGD industry since 2006 when he worked for Nalco Canada providing service to the Suncor Firebag and ConocoPhillips Canada Surmont plants. He has a bachelor’s degree in materials engineering from Simon Bolivar <<Back>> <<Next>>
ASME PANEL SESSION - 2014 University of Venezuela and an MBA at the University of Calgary. In 2011 he presented a paper at IWC. He’s part of the ASME Produced Water Consensus Task Group and has worked as session chair, discussion leader, and advisory council member for the IWC so we are very happy to have Ivan helping us with our ASME session. So with that, Ivan, do you want to start on the discussion side? Ivan Morales, Devon Energy, Canada: Well like Melonie said we are going to be opening the floor for questions and the questions can be related to any of the presentations. We have a great panel here today with a lot of experience, but also we would like to hear if you have any other questions that could be open to the floor as well. As a reminder, please state your name and affiliation for the transcript. Raise your hand for the microphone and let us know if this is a continuation on the topic that we are discussing or if it’s a new topic. Please be patient, you all are going to have a chance to speak today. Charles Dyke, WorleyParsons: We are looking at a steam flooding application with OTSGs and also modeling then with OTS OLI. And looking at the scaling I know that sodium EDTA or
ASME PANEL SESSION - 2014 Subodh Peramanu, Canadian Natural Resources, Ltd.: No, we didn’t look at EDTA because in our CSS operation we never had to use EDTA to control the hardness. We regularly just use amine and then a sodium bisulfite to control the oxygen level, so EDTA was not the one we looked at. Charles Dyke: I’ve got a follow-up question. In our case we are making our OTSG feed water with an evaporator so we have very, very high quality water with a TDS of about 20 ppm. That’s the feed water quality, but calcium is predicted to still be about 0.1 to 0.2 ppm. So one of our process engineers up in Calgary suggested our feed water is so good that we can recirculate the
ASME PANEL SESSION - 2014 ppm, so it’s well within the 40,000 ppm you might be able to see in an OTSG. And for that reason they are saying “Well, why we can’t we do it that way? Why can’t we do that and get these really high recoveries by recirculating the blowdown?” So has anybody had any experience doing that? Rafael Gay-de-Montella, Transprocess Inc.: My point of view is many people forget about the blowdown, but when you look at a true boiler you have other things than the actual feed water. You have for instance substrates and you can have other things. The thing is that the blowdown could go in the range of 3,000 to maybe 4,000 ppm, and if you are having 600 ppm I don’t see any reason why you couldn’t recycle; but, there is always a “but”, in recycling are you then saying that you are getting 90% dryness in your pipes? Charles Dyke: We are only saying 80% of water per pass will be evaporated. Rafael Gay-de-Montella: Okay, you say 80% per pass. Charles Dyke: Okay, per pass 80% of the water is evaporating into steam and 20% stays liquid. Then that liquid is recirculated back to the front end of the system combining with the net feed
J. (1982). Process Chemistry for Water and Wastewater Treatment. Englewood Cliffs:
Prentice-Hall, Inc. Blythe, G. (2008). Factors Affecting Mercury Chemistry and Capture in Wet FGD Systems. PowerGen Conference.
S. (2012). Corrosion in Alloy WFGD Absorber Reaction Tanks. In AWMA (Ed.), MEGA
R. (2013). Optimization and Process Control of Air Quality Control Systems for Improved
Brown, S. R. (2013, July). ORP as a Predictor of WFGD Chemistry and Wastewater Treatment. POWER, 157, 40-42.
Chang, R. a. (2012, November). Current Strategies for MATS Compliance: Technologies of Mitigation of Mercury. EPRI 1023938.
Edstrom Industries. (2003). Forms of Chlorine in Water.
Emmerson Process Management. (2008, May). Fundamentals of ORP Measurment. Retrieved June 24, 2014, from http://www2.emersonprocess.com/siteadmincenter/PM%20Rosemount%20Analytical%20Docum ents/Liq_ADS_43-014.pdf
FMC Industrial Chemicals. (2010). Persulfates Technical Brochure.
S. (1999). Elements of Chemical Reaction Engineering. Upper Saddle River: Prentice Hall, Inc.
Guberlet, H. (1996). Flue Gas Cleaning Chemistry. Power Plant Chemical Technology, International Conference.
B. (2009). Crystallisation of Gypsum and Prevention of Foaming in Wet Flue Gas Desulphurisation (FGD) Plants. Copenhagen: Department of Chemical and Biochemical
W. (2002). Procedure Used for Root Cause Analysis: Pitting in Stainless Steel Tubes Associated with MnO2 Deposition. Corrosion (p. Paper 02472). San Diego.
Pourbaix, M. (1966). Atlas of Electrochemical Equilibria in Aqueous Solutions (Vol. Volume 1). Pergamon Press.
Rosenberg, H.S. (Environmental Science & Technology). NOx Influence on Sulifte Oxidation and Scaling in Lime/Limestoen Flue Gas Desulfurization (FGD) Systems. Amercain Chemical Society, 470472. The Babcock & Wilcox Company. (2005). Steam/its Generation and Use (41st ed.). (J. B. Kitto and S.C.
Stultz, eds.) United States Environmental Protection Agency. (2009). Steam Electric Power Generating Point Source Category: Final Detailed Study Report. Disclaimer Although the information presented in this work is believed to be reliable, this work is published with the understanding that Babcock & Wilcox Power Generation Group, Inc. (B&W PGG) and the authors and contributors to this work are supplying general information and are not attempting to render or provide engineering or professional services. Neither B&W PGG nor any of its employees make any warranty, guarantee or representation, whether expressed or implied, with respect to the accuracy, completeness or usefulness of any information, product, process, method or apparatus discussed in this work, including warranties of merchantability and fitness for a particular or intended purpose. Neither B&W PGG nor any of its officers, directors or employees shall be liable for any losses or damages with respect to or resulting from the use of, or the inability to use, any information, product, process, method or apparatus discussed in this work. <<Back>> <<Next>>