{"document":{"doc_id":21829,"source":"ria","org":"HUD","doc_type":"regulatory_impact_analysis","title":"Regulatory Impact Analysis","date":"2018-12-10","url":"https://www.regulations.gov/document/HUD-2018-0097-0002","source_native_id":"HUD-2018-0097-0002","status":"fetched","abstract":null,"action":null},"dockets":["HUD-2018-0097"],"rins":["RIN 2506-AC45"],"related":[{"doc_id":8076,"source":"fr_rule","org":"DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT","doc_type":"Proposed Rule","title":"Conforming the Acceptable Separation Distance (ASD) Standards for Residential Propane Tanks to Industry Standards","date":"2018-12-10"},{"doc_id":7245,"source":"fr_rule","org":"DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT","doc_type":"Rule","title":"Conforming the Acceptable Separation Distance (ASD) Standards for Residential Propane Tanks to Industry Standards","date":"2020-01-24"},{"doc_id":129271,"source":"docket_item","org":"HUD","doc_type":"analysis","title":"6054-F-02  HUD Propane Final Rule_RIA Final 1-24-2020","date":"2020-01-24"},{"doc_id":209480,"source":"docket_item","org":"HUD","doc_type":"other","title":"6054-F-02 FONSI","date":"2020-01-24"}],"references":[{"citation_id":294982,"raw_reference":"Safety Consideration in Siting Housing Projects, prepared by Arthur D. Little Inc., 1975","cited_authors":"Arthur D. Little Inc.","cited_year":"1975","cited_title":"Safety Consideration in Siting Housing Projects","cited_venue":"HUD","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 3","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294983,"raw_reference":"Urban Development Siting with Respect to Hazardous Commercial/Industrial Facilities, by Rolf Jensen and Associates Inc., 1982","cited_authors":"Rolf Jensen and Associates Inc.","cited_year":"1982","cited_title":"Urban Development Siting with Respect to Hazardous Commercial/Industrial Facilities","cited_venue":"HUD","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 3","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294984,"raw_reference":"Ahrens, M. (2018). Home Structure Fires in Which LP-Gas was the Type of Material First Ignited and the Type of Material First Ignited in All Home Structure Fires, Research, National Fire Protection Association, Quincy, MA, May.","cited_authors":"Ahrens, M.","cited_year":"2018","cited_title":"Home Structure Fires in Which LP-Gas was the Type of Material First Ignited and the Type of Material First Ignited in All Home Structure Fires","cited_venue":"National Fire Protection Association","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 7","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294985,"raw_reference":"Ahrens, M. (2017). Home Structure Fires Involving Lightning and/or Natural Gas or LP-gas, Research, National Fire Protection Association, Quincy, MA, February.","cited_authors":"Ahrens, M.","cited_year":"2017","cited_title":"Home Structure Fires Involving Lightning and/or Natural Gas or LP-gas","cited_venue":"National Fire Protection Association","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Section 8 References","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294986,"raw_reference":"Flynn, J. (2010). Natural Gas and LP-gas Home Structure Fires, Fire Analysis and Research, National Fire Protection Association, Quincy, MA, January.","cited_authors":"Flynn, J.","cited_year":"2010","cited_title":"Natural Gas and LP-gas Home Structure Fires","cited_venue":"National Fire Protection Association","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 7","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294987,"raw_reference":"Hall, J. R. (2014). Fires Starting with Flammable or Combustible Gas or Liquid, Fire Analysis and Research Division, National Fire Protection Association, Quincy, MA, February.","cited_authors":"Hall, J. R.","cited_year":"2014","cited_title":"Fires Starting with Flammable or Combustible Gas or Liquid","cited_venue":"National Fire Protection Association","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 7","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294988,"raw_reference":"Bullerdiek, W.A. (1986). Engineering Hazard Analysis of Residential LP-gas Fuel Usage, Frontier Technical Associates Report, June. Prepared for U.S. Consumer Product Safety Commission.","cited_authors":"Bullerdiek, W.A.","cited_year":"1986","cited_title":"Engineering Hazard Analysis of Residential LP-gas Fuel Usage","cited_venue":"Frontier Technical Associates","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Section 5.1 Risk Analysis","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294989,"raw_reference":"Raj, P. (2005). Exposure of a liquified gas container to an external fire, Journal of Hazardous Materials, 122(1-2): 37–49.","cited_authors":"Raj, P.","cited_year":"2005","cited_title":"Exposure of a liquified gas container to an external fire","cited_venue":"Journal of Hazardous Materials","cited_doi":"10.1016/j.jhazmat.2005.04.004","cited_url":null,"ref_kind":"journal_article","section":"fn 13","page":null,"context_sentence":null,"paper_id":37166,"paper_title":"Exposure of a liquefied gas container to an external fire","paper_year":2005,"paper_doi":"10.1016/j.jhazmat.2005.04.004"},{"citation_id":294990,"raw_reference":"Roscioli, J., et al. (2017). Methane, Ethane, and Propane Sensor for Real-time Leak Detection and Diagnostics, U.S. Department of Energy. https://www.osti.gov/servlets/purl/1347976.","cited_authors":"Roscioli, J., et al.","cited_year":"2017","cited_title":"Methane, Ethane, and Propane Sensor for Real-time Leak Detection and Diagnostics","cited_venue":"U.S. Department of Energy","cited_doi":"10.2172/1347976","cited_url":"https://www.osti.gov/servlets/purl/1347976","ref_kind":"research_report","section":"fn 21","page":null,"context_sentence":null,"paper_id":58129,"paper_title":"Methane, Ethane, and Propane Sensor for Real-time Leak Detection and Diagnostics","paper_year":2017,"paper_doi":"10.2172/1347976"},{"citation_id":294991,"raw_reference":"National Fire Protection Association (2018). Fact Sheet Liquified Petroleum Gas, March, National Fire Protection Association, Quincy, MA.","cited_authors":"National Fire Protection Association","cited_year":"2018","cited_title":"Fact Sheet Liquified Petroleum Gas","cited_venue":"National Fire Protection Association","cited_doi":null,"cited_url":null,"ref_kind":"web_page","section":"Section 5.1 Risk Analysis","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294992,"raw_reference":"Nette, E. (2017). NFPA 58 LP-Gas Code Handbook, 11th edition, National Fire Protection Association, Quincy, MA.","cited_authors":"Nette, E.","cited_year":"2017","cited_title":"NFPA 58 LP-Gas Code Handbook","cited_venue":"National Fire Protection Association","cited_doi":null,"cited_url":null,"ref_kind":"book","section":"Section 8 References","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294993,"raw_reference":"U.S. Fire Administration (2017). Fire in the United States 2006-2015, 19th edition, December.","cited_authors":"U.S. Fire Administration","cited_year":"2017","cited_title":"Fire in the United States 2006-2015","cited_venue":"U.S. Fire Administration","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"fn 12","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294994,"raw_reference":"U.S. Department of Housing and Urban Development (2011). Acceptable Separation Distance Guidebook, Office of Community Planning and Development.","cited_authors":"U.S. Department of Housing and Urban Development","cited_year":"2011","cited_title":"Acceptable Separation Distance Guidebook","cited_venue":"Office of Community Planning and Development","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"fn 4","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294995,"raw_reference":"U.S. Consumer Product Safety Commission (1987). Characterization of LP-Gas Odorant Fade. Prepared by Arthur D. Little, Inc.","cited_authors":"U.S. Consumer Product Safety Commission; Arthur D. Little, Inc.","cited_year":"1987","cited_title":"Characterization of LP-Gas Odorant Fade","cited_venue":"U.S. Consumer Product Safety Commission","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 19","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":294996,"raw_reference":"Energy Information Administration, 2015 Residential Energy Consumption Survey (RECS)","cited_authors":"U.S. Energy Information Administration","cited_year":"2015","cited_title":"Residential Energy Consumption Survey (RECS)","cited_venue":"U.S. Energy Information Administration","cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"Section 4.1.1","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}