Policy Replication

Verification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust

Federal Register2000-07-07 · DEPARTMENT OF LABOR; Mine Safety and Health Administration · Proposed Rule · 00-16149
Proposed rule; notice of hearings.

MSHA is proposing to revoke existing operator respirable dust sampling procedures under parts 70 and 90, and to implement new regulations that would require each underground coal mine operator to have a verified mine ventilation plan. Under this proposal, MSHA would verify the effectiveness of the mine ventilation plan for each mechanized mining unit (MMU) in controlling respirable dust under typical mining conditions. MSHA would collect full-shift respirable dust samples, called "verification samples," to demonstrate the adequacy of the dust control parameters specified in the mine ventilation plan in maintaining the concentration of respirable coal mine and quartz dust at or below 2.0 mg/m\3\ and 100 <greek-m>g/m\3\, respectively. The adequacy of these parameters would be demonstrated on shifts during which the amount of the material produced is at or above the "verification production level" (VPL) or the tenth highest production level recorded in the most recent 30 production shifts. The proposal would require mine operators to: First, set and maintain the dust control parameters during MSHA verification sampling at levels specified in the plan; second, maintain and make available to MSHA records of the amount of material produced by each mechanized mining unit during each production shift; and third, additional information in mine ventilation plans. For longwall mine operations, MSHA is also proposing to permit the use of either approved powered, air-purifying respirators (PAPRs) or verifiable administrative controls as a supplemental means of compliance if MSHA has determined that further reduction in respirable dust levels cannot be achieved using all feasible engineering or environmental controls appropriate for the operational conditions involved. In addition, through this rule, MSHA would conduct all compliance and abatement sampling under existing parts 70 and 90.

RIN 1219-AB14

Other documents for the same rulemaking (all, by stage)

2000-07-07 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2000-07-25 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust; Correction
2000-08-11 Federal RegisterDetermination of Concentration of Respirable Coal Mine Dust; Verification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2003-03-06 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2003-03-17 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust; Determination of Concentration of Respirable Coal Mine Dust
2003-04-01 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2003-05-29 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2003-07-03 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust

References: 106 extracted, 48 linked to papers

Page 3Download these results: CSV · JSON
Attfield and Morring, 1992a
MSHA recognizes that simple CWP increases the risk of developing PMF substantially (Cochrane, 1962; Jacobsen, et al., 1971; McLintock, et al., 1971; Balaan, et al., 1993). Progressive massive fibrosis (PMF) is associated with decreased lung function and increased premature mortality (Rasmussen, et al., 1968; Atuhaire, et al., 1985; Miller and Jacobsen, 1985; Attfield and Wagner, 1992).
Boden, L.I. and Gold, M.
journal articleThe accuracy of self‐reported regulatory data: The case of coal mine dust (1984) · Section V.C.3 Epidemiological Literature
studies is the possible bias in the exposure data, which has been the subject of several studies (Boden and Gold, 1984; Seixas et al., 1991; Attfield and Hearl, 1996).
Freedman, A.P. and S.E. Robinson
book chapterNot linked to a paper · Section V.C.2 Toxicological Literature
Fiscor, S.
newsNot linked to a paper · Appendix B References
Greenough, G.K.
journal articleTrials of the dust helmet in coal mines (1980) · Appendix B References
Soft plastic seals join the face-shield visor to the sides of the head and jaw limiting entry of unfiltered mine air (Greenough, 1979).
Bartley, D.
otherNot linked to a paper · Appendix A Derivation of the Critical Values