Existing Chemical Exposure Limit (ECEL) for Occupational Use of Methylene Chloride
Other documents for the same rulemaking (all, by stage)
References
DCM) CASRN: 75-09-2. EPA-740-R1-8010. Office of Chemical Safety and Pollution Prevention. June 2020. Available at: EPA-HQ-OPPT-2019-0437-0107. U.S. Environmental Protection Agency. 2002. A Review of the Reference Dose and Reference Concentration Processes. Final Report. EPA/630/P-02/002F. Prepared for the Risk Assessment Forum. December. 1 EPA used the 1st percentile to account for susceptibility from the toxicokinetic variability among humans related to differences in metabolism. Using the 1st percentile, EPA reduced the intraspecies uncertainty factor (UFH) from 10 to 3. The remaining UFH of 3 accounts for any toxicodynamic differences among humans. Appendix B: Summary of Current Workplace Air Monitoring Methods for Methylene Chloride This summary provides associated limits of detection or quantification, which generally range from about 0.2 to 0.4 ppm.
NIOSH Manual of Analytical Methods (NMAM); 5th Edition (April 2016) (https://www.cdc.gov/niosh/nmam/default.html)
NIOSH NMAM 4th Edition (January 1998) (https://www.cdc.gov/niosh/docs/2003154/default.html)
NIOSH NIOSH 1998 (Issue 3) https://www.cdc.gov/niosh/docs/2003-154/pdfs/1005.pdf 1005 (4th Ed.), PubChem
NIOSH NIOSH 1996 (Issue 1) https://www.cdc.gov/niosh/docs/2003-154/pdfs/2549.pdf 2549 (4th Ed.), PubChem
NIOSH NIOSH 2016 (Issue 2) https://www.cdc.gov/niosh/docs/2014MAM 3800 151/pdfs/methods/3800.pdf (5th Ed.)
NIOSH NIOSH 2018 https://www.cdc.gov/niosh/nmam/pdf/3900.pdf 3900 (5th Ed.)
OSHA, OSHA 1990 https://www.osha.gov/dts/sltc/methods/organic/org080/org PubChem 80 080.html Note that NIOSH method 3800 is a direct-reading instrument, and direct-reading methods may have the lower accuracy compared to the other collection methods. A summary of the methods found in the search is shown in Table 2, which includes sampling media, equipment, analytical instruments, LOD/LOQs and sampling volume and flow rate. Table 2: Summary of Workplace Air Monitoring Methods PerSample Concentration Sampling
NIOSH Charcoal GC + FID LOD: 0.4 Working range: 0.4 1005 sampling analysis to 749 ppm (1.4 to (Rev. sorbent tubes; per sample 2600 mg/m3) for a (estimated) 1-L air sample. 1998) personal sampling Accuracy: +/pump 15.8% Precision: 0.076
NIOSH Charcoal GC + LOD: Extrapolated 1005 sampling electron 0.002 µg working range 200 (Rev. sorbent tubes; capture per sample times lower than 1998) personal detector (estimated) GC+FID: 0.0002 to Alternate sampling (ECD) 3.7 ppm analytical pump desorbed equipment with toluene Accuracy: +/15.8% Precision: 0.05 at 320 µg.
OSHA (Occupational Safety and Health Administration). 1990. Method 80: Methylene Chloride. Sampling and Analytical Methods. OSHA Salt Lake Technical Center, Sandy, UT. https://www.osha.gov/dts/sltc/methods/organic/org080/org080.html
NIOSH (National Institute for Occupational Safety and Health). 1998. Method 1005, Issue 3: Dichloromethane (in Methylene Chloride). NIOSH Manual of Analytical Methods (NMAM), 4th Edition. http://www.cdc.gov/niosh/docs/2003-154/pdfs/1005.pdf
NIOSH (National Institute for Occupational Safety and Health). 1996. Method 2549, Issue 1: Dichloromethane (in VOLATILE ORGANIC COMPOUNDS (SCREENING)). NIOSH Manual of Analytical Methods (NMAM), 4th Edition. https://www.cdc.gov/niosh/docs/2003154/pdfs/2549.pdf
NIOSH (National Institute for Occupational Safety and Health). 2003. Method 3800, Issue 2: Dichloromethane ( in ORGANIC AND INORGANIC GASES by Extractive FTIR Spectrometry).
NIOSH Manual of Analytical Methods (NMAM), 5th Edition. https://www.cdc.gov/niosh/docs/2014-151/pdfs/methods/3800.pdf
NIOSH (National Institute for Occupational Safety and Health). 2018. Method 3900, Issue 1: Dichloromethane (in Volatile Organic Compounds, C1 to C10, Canister Method). NIOSH Manual of Analytical Methods (NMAM), 5th Edition. https://www.cdc.gov/niosh/nmam/pdf/3900.pdf