Comment letter from the Halogenated Solvents Industry Alliance, Inc. on the draft perchloroethylene TSCA risk evaluation
Other documents for the same rulemaking (all, by stage)
References
Tibaldi, R., ten Berge, W., & Drolet, D. (2014). Dermal absorption of chemicals: estimation by IH SkinPerm. Journal of Occupational and Environmental Hygiene, 11(1), 19-31.
Tibaldi, R., ten Berge, W., & Drolet, D. (2017). IH SkinPerm v2.0 Reference Manual. AIHA Exposure Assessment Strategies Committee. Available at: https://aihaassets.sfo2.digitaloceanspaces.com/AIHA/resources/IH_SkinPerm_Manual_May_2017.pdf
USEPA. (2020a). DRAFT Risk Evaluation for Perchloroethylene (Ethene, 1,1,2,2-Tetrachloro)
USEPA. (2020b). Assessment of Occupational Exposure and Environmental Releases for Perchloroethylene (Ethene, 1,1,2,2-Tetrachloro) CASRN: 127-18-4. Office of Chemical Safety and Pollution Prevention. July 6, 2020 Cardno ChemRisk Appendix 11 Distribution Analysis of Perchloroethylene Manufacturing Data Prepared for Halogenated Solvents Industry Alliance, Inc. 3033 Wilson Boulevard, Suite 700
Cincinnati, Ohio 45242 July 6, 2020 Distribution Analysis of PCE Manufacturing Data Table of Contents Introduction ..................................................................................................................... 1-1 Background on IH Data Sets .......................................................................................... 2-1 Case Study Using HSIA Data Set ................................................................................... 3-1 Occupational Non-Users ................................................................................................ 4-1 Conclusions..................................................................................................................... 5-1 References ....................................................................................................................... 6-1 July 6, 2020 Cardno ChemRisk Distribution Analysis of PCE Manufacturing Data Introduction In August 2018, the Halogenated Solvents Industry Alliance, Inc. (HSIA) submitted commentary to the United States Environmental Protection Agency (EPA) in response to the EPA’s problem formulation phase of the perchloroethylene (PCE) Toxic Substances Control Act (TSCA) risk evaluation. Within these comments, HSIA provided an occupational exposure dataset for various exposure scenarios in PCE manufacturing facilities, including 8- and 12-hour full-shift samples and 15- and 30-minute task-length samples.
EPA utilized the dataset provided by HSIA in its 2020 draft PCE risk evaluation to characterize exposures to workers and occupational non-users (ONUs) for manufacturing use scenarios (EPA, 2020). The 50th percentile central tendency exposure (CTE) and the 95th percentile values for 15-minute, 30-minute, 8-hour, and 12-hour time-weighted average (TWA) exposures calculated from the HSIA data were selected as representative of typical worker exposures, while the 50th
CTE was selected as representative of ONU exposures. The exposure data submitted by HSIA were highly censored, with 65%, 73%, 24%, and 55% of the 8-hour, 12-hour, 15-minute, and 30-minute TWA exposure data below the limit of detection (LOD), respectively. Therefore, the calculated exposure estimates are highly influenced by the high-end outliers in this dataset. Because of the task-oriented nature of chemical manufacturing, as discussed further below, these EPA estimates are likely an inappropriate lumping of routine and non-routine tasks. To address values reported as below the LOD, EPA relied upon guidance provided in the EPA Guidelines for Statistical Analysis of Occupational Exposure Data (EPA, 1994). For the 8-hour, 12-hour, and 15-min samples, the LOD divided by 2 (LOD/2) was used as a substitute for values reported as lower than the LOD, while the LOD divided by the square root of 2 was substituted for 30-min samples below the LOD. The EPA recognized the potential introduction of bias through the use of LOD substitution methods on highly censored data sets (>50% samples below the
LOD divided by the square root of 2 was utilized for samples that were reported as below an identified LOD. Following the AIHA recommendations for exposure monitoring data sets, summary statistics were calculated for the full, task-length, and unspecified samples, provided in Table 1. Table 1: Summary Statistics of Full-shift, Task-length, and Unspecified Sample Types from 2018 HSIA Manufacturing Monitoring Data Full-Shift Task Length Unspecified Sample Type Sample Count a Average Duration (min) 16.9 23.2 Average Concentration (ppm) 0.29 5.19 5.89 Standard Deviation (ppm) 0.98 16.2 4.82 Minimum 0.01 0.03 1.52 Maximum 8.74 11.2 Average of Ln Concentration -2.92 0.52 1.44 St. Dev. of Ln Concentration 1.40 1.46 1.00 Geometric Mean 0.05 1.68
EPA. July 6, 2020 Cardno ChemRisk