Existing Chemical Exposure Limit (ECEL) for Occupational Use of Carbon Tetrachloride
Other documents for the same rulemaking (all, by stage)
References
EPA conducted a web search to identify relevant NIOSH/OSHA/EPA analytical methods used to monitor for the presence of carbon tetrachloride in air (see Table 1). The sources used for the search included the following: 1) NIOSH Manual of Analytical Methods (NMAM); 5th Edition o URL: https://www.cdc.gov/niosh/nmam/default.html 2) NIOSH NMAM 4th Edition o URL: https://www.cdc.gov/niosh/docs/2003-154/default.html 3) OSHA Index of Sampling and Analytical Methods o URL: https://www.osha.gov/dts/sltc/methods/ 4) EPA Environmental Test Method and Monitoring Information o URL: https://www.epa.gov/emc/epa-websites-environmental-test-method-and-monitoringinformation Table 1: LOD summary for air sampling analytical methods identified. Air Sampling Year Limit of Analytical Notes Published Detection (LOD) Methods
EPA Method 325 b (method for VOCs) 2003 (Issue 3) specified 2019 (updated)
LOD: 4 µg per sample Source LOD is for carbon tetrachloride https://www.cdc.gov/niosh/docs/ 2003-154/pdfs/1003.pdf