Voluntary Consensus Standard Results for Large Municipal Waste Combustors NSPS and EG
Other documents for the same rulemaking (all, by stage)
References
ASTM D3154-00 (2014) - Standard Method for Average Velocity in a Duct (Pitot Tube Method)
EPA Method 2, 3A, 4, ASME B133.9-1994 (2001) - Measurement of Exhaust Emissions from Stationary Gas Turbine Engines (Revision of ANSI B133.9-1979)
ASME B133.9-1994 (2001) is the latest version. This method has been withdrawn with no further updates
EPA Method 3, 6C, 7A, ISO 10396:(2007) - Stationary Source Emissions: Sampling for the Automated Determination of Gas Concentrations
ANSI/ASME PTC 19-10-1981- Part 10 (2010) Flue and Exhaust Gas Analyses This standard includes manual and instrumental methods of analyses for carbon dioxide (CO2), carbon monoxide (CO), hydrogen sulfide (H2S), nitrogen oxides (NOx), oxygen (O2), and sulfur dioxide (SO2). The VCS method analytes that include one or more of the same techniques as the EPA
ISO 12039:2001(2012) - Stationary Source Emissions Determination of Carbon Monoxide, Carbon Dioxide, and Oxygen Automated Methods
EPA Method 3, 10 ASTM D5835-95 (2013) - Standard Practice for Sampling Stationary Source Emissions for Automated Determination of Gas Concentration This method is similar to EPA Methods 3A, 10, and 20 (oxygen portion of 20 only). However, ISO 12039 is missing some key features. In terms of sampling, the hardware required by ISO 12039 does not include a 3-way calibration valve assembly or equivalent to block the sample gas flow while calibration gases are introduced. In its calibration procedures, ISO 12039 only specifies a two-point calibration while the EPA methods specify a 3-point calibration. Also,
EPA Method 5 ISO 9096:1992 (2003) - Determination of Concentration and Mass Flow Rate of Particulate
EPA Method 5 ANSI/ASME PTC-38-1980 (1985) - Determination of the Concentration of Particulate Matter in Gas Streams
ASTM D3685/D3685M- 98 (2013) - Test Methods for Sampling and Determination of Particulate Matter in Stack Gases
CAN/CSA Z223.1 requires only weighing to the nearest 0.5 mg. Lastly, CAN/CSA Z223.1 allows the use of a standard pitot for velocity measurement when plugging of the tube opening is not expected to be a problem, whereas EPA Method 5 requires an S-shaped pitot. This standard is only applicable to sources with 30 mg/m3 SO2 or more. Also, this standard does not separate SO3 from SO2 as does the EPA methods; therefore, ISO 7934:1998 is not valid if more than a negligible amount of SO3 is present.
EPA Method 6 ISO 7934:1998 - Stationary Source Emissions Determination of the Mass Concentration of Sulfur Dioxide Hydrogen Peroxide/Barium Perchlorate/Thorin Method (This standard was reviewed and confirmed 2010)
EPA Method 6 ISO 11632:1998 - Stationary Source Emissions Determination of the Mass Concentration of Sulfur Dioxide Ion Chromatography (This standard was reviewed and confirmed 2016) Sampling procedures are similar to EPA Method 6, but lacks in detail and quality control procedures, such as calibration checks and leaks tests.
EPA Method 7 ASTM D1608-98 (2016) - Test Method for Oxides of Nitrogen in Gaseous Combustion Products (PhenoDisulfonic Acid Procedures) This standard is very similar to EPA Method 7, however there are some key differences. ASTM D1608 variations are as follows (corresponding EPA Method 7 procedures are in parentheses and italics): 405 nm absorbance (410 nm or optimized); 3 mL of 3% hydrogen peroxide in the absorbing solution (6 mL 3% hydrogen peroxide); no shaking of reaction flask to mix before or after sitting (shake for at least 5 minutes before and 2 minutes after sitting); overnight sample sitting
EPA Method 7, 7C ISO 11564:1998 - Stationary Source Emissions Determination of the Mass Concentration of Nitrogen Oxides - NEDA (naphthylethylenediamine)/ Photometric Method (This standard was reviewed and confirmed 2016)
EPA Method 23 EN 1948-3 (2006) (European Committee for Standardization)-Determination of the Mass Concentration of PCDD’S/PCDF’S Part 3: Identification and Quantification Provides additional sampling options other than what is acceptable in EPA Method 23.
EPA Method 26, 26A EN 1911-1,2,3 (1998) - Stationary Source EmissionsManual Method of Determination of HCl-Part 1: Sampling of Gases Ratified European Text-Part 2: Gaseous Compounds Absorption Ratified European Text-Part 3: Adsorption Solutions Analysis and Calculation Ratified European Text Part 3 of this standard cannot be considered equivalent to EPA
EN 13211:2001 - Air Quality Stationary Source Emissions Determination of the Concentration of Total Mercury
Since ASTM D4358-94 (1999) does not require the use of HF, it cannot be used in the preparation, digestion, and analysis of Method 29 samples.