LIST OF PICTURES Picture 1. The north end of Room 1, Panel 1 on March 4, 1998 Picture 2. The north end of Room 7, Panel 1 and S1600 drift on March 4, 1998 Picture 3. A waste-handling-bay crane is lifting a 14-drum pack with simulated waste from them TRUPACT-II Picture 4. Three TRUPACT-II shipping containers with simulated waste arrive at the WffP security gate for inspection P.10
American National Standards Institute. 1969. Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities. La Grange Park, IL: American Nuclear Society, ANSI N13.1-1969.
American National Standards Institute. 1983. Nuclear Safety Criteria for the Design of Stationary Pressurized Water Reactor Plants. La Grange Park, IL: American Nuclear
Society, ANSI/ANS-51.1-1983. Bartlett, W. T. 1993. An Evaluation ofthe Air Effluent and Workplace Radioactivity Monitoring*at the Waste Isolation Pilot Plant. Albuquerque, NM: Environmental Evaluation Group, i
EEG-52. Bartlett, W. T. and B. A. Walker. 1996. The Influence of Salt Aerosol on Alpha Radiation Detection by WffP Continuous Air Monitors. Albuquerque, NM: Environmental Evaluation Group, EEG-60.
Bartlett, W. T. and B. A. Walker. 1997. "The Influence of Salt Aerosol on Alpha Radiation Detection by WffP Continuous Air Monitors," in the Proceedings ofthe 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference, Portland, Oregon, July 15-18, 1996, edited by M. W. First. Boston, MA: Harvard School of Public Health, 188-201.
Chavez, M. C, D. L. O'Neal, A. McFarland, C. Ortiz. 1997. An Analysis of Salt Deposition on the Performance ofthe WffP Station A Air Sampling System. Submitted to the Westinghouse Electric Corporation in August.
Conway, J. T. 1998. February 17 letter from J. T. Conway, Chairman DNFSB to the Congress ofthe United States, Annual Report for calendar year 1997.
Defense Nuclear Facilities Safety Board. 1997. Integrated Safety Management. Technical
Report, DNFSB/TECH-16. Duke Engineering and Services. 1996. Exhaust Shaft Hydraulic Assessment Data Report. Westinghouse Electric Corporation, Waste Isolation Division, DOE/WIPP 97-2219. P.40 Duke Engineering and Services. 1997. Exhaust Shaft: Phase 2 Hydraulic Assessment Data Report Involving Drilling, Installation, Water-Quality Sampling, and Testing of Piezometers 1-12. Westinghouse Electric Corporation, Waste Isolation Division,
DOE/WIPP 97-2278. Greenfield, M. A. 1990. Probabilities of a Catastrophic Waste Hoist Accident at the Waste Isolation Pilot Plant. Albuquerque, NM: Environmental Evaluation Group, EEG-44.
Greenfield, M. A. and T. J. Sargent. 1993. A Probabilistic Analysis of a Catastrophic Waste Hoist Accident at the WffP. Albuquerque, NM: Environmental Evaluation Group, EEG53.
Greenfield, M. A. and T. J. Sargent. 1995. An Analysis ofthe Annual Probability of Failure of the Waste Hoist Brake System at the Waste Isolation Pilot Plant (WIPP). Albuquerque,
Greenfield, M. A. and T. J. Sargent. 1998. Probability of Failure ofthe Waste Hoist Brake System at the Waste Isolation Pilot Plant (WffP). Albuquerque, NM: Environmental Evaluation Group, EEG-65.
Hunter, E. K. 1998a. February 27 letter from E. Kent Hunter, DOE, Office of National TRU Waste Operations to Robert H. Neill, Director, EEG, on request for drawings underground ventilation system.
Hunter, E. K. 1998b. March 27 letter from E. Kent Hunter, DOE, Office of National TRU Waste Operations to Robert H. Neill, Director, EEG, on request for DNFSB's WffP SAR comments and CAO reply.
Kenney, J. W., D. H. Gray, and S. C. Ballard. 1998. Preoperational Radiation Surveillance ofthe WffP Project by EEG During 1993 through 1995. Albuquerque, NM: Environmental Evaluation Group, EEG-67.
Maleki, H. and L. Chaturvedi. 1996. Stability Evaluation ofthe E140 Drift and Panel 1 Rooms at WffP. Albuquerque, NM: Environmental Evaluation Group, EEG-63.
Nazarali, A. M., M. W. Carter, G. E. Chabot, and K. W. Skrable. 1993. Analysis ofthe Underground Effluent Dispersion and Deposition for Off-site and On-site Radiation Dose Assessment at the Waste Isolation Pilot Plant (WffP) Using Smoke Test Method. Westinghouse Electric Corporation, Waste Isolation Division, DOE/WIPP-92-051.
Neill, R. H. 1998. January 26 letter from R. H. Neill, Director, EEG to G. E. Dials, Manager,
DOE/CAO, on the review of 1997 SAR. Schepens, Roy. 1998. Department of Energy Operational Readiness Review for the Startup of the Waste Isolation Pilot Plant, March 10. U.S. Department of Energy. P.41 U.S. Congress. 1992. Waste Isolation Pilot Plant Land Withdrawal Act, Public Law 102-579, October 23. U.S. Congress. 1996a. Balanced Budget Downpayment Act, I. Public Law 104-99. U.S. Congress. 1996b. Waste Isolation Pilot Plant Land Withdrawal Act, Public Law 102-579, October 23, 1992, as amended by Public Law 102-201, September 23. U.S. Department of Energy. 1989. General Design Criteria. DOE Order 6430.1 A. U.S. Department of Energy. 1994. Personnel Selection, Qualification, and Training Requirements for DOE Nuclear Facilities. DOE Order 5480.20A. U.S. Department of Energy. 1995. Startup and Restart of Nuclear Facilities. DOE Order 425.1, Chgl. U.S. Department of Energy, Carlsbad Area Office. 1996. Waste Acceptance Criteria for the Waste Isolation Pilot Plant. DOE/WIPP-069, Rev. 5. U.S. Department of Energy, Carlsbad Area Office. 1997a. National TRU Waste Management Plan. DOE/NTP-96-1204, Rev. 1. §U.S. Department of Energy, Carlsbad Area Office. 1997b. Waste Isolation Pilot Plant Disposal Phase Final Supplemental Impact Statement. DOE/EIS-0026-S-2/V. 1.
Weaver, G, D. L. O'Neal, A. McFarland, and C. Ortiz. 1996. Analysisof Salt and Moisture on the Air Sampling Probes at the Waste Isolation Pilot Plant. Submitted to the Westinghouse Electric Corporation in April. ESL/TR-W1. Westinghouse Electric Corporation, Waste Isolation Division. 1997a. Waste Isolation Pilot Plant Safety Analysis Report. DOE/WIPP-95-2065, Rev. 1. Westinghouse Electric Corporation, Waste Isolation Division. 1997b. Waste Isolation Pilot Plant Safety Analysis Report. DOE/WIPP-95-2065, Rev. 2. Westinghouse Electric Corporation, Waste Isolation Division. 1998a. "Posting and Access," WP12-HP1500, Rev. 0, 3/27/97, in Control WffP Operational Health Physics Procedures Manual. WP12-HP. Westinghouse Electric Corporation, Waste Isolation Division. 1998b. "TLD Assignment, Issue and Retrieval," WP 12-DS3326, Rev. 0, Chg. 2, in Dosimetry Program Manual. WP12-3.
Winters, D. and J. Roarty. 1997. June 17 memorandum from D. Winters and J. Roarty to G. W.