BDL–742 BDL–4,630 References Solo-Gabriele et al., 2020 Solo-Gabriele et al., 2020
PFAS-containing wastes (e.g., building materials and carpeting with fluoropolymer coatings) (OECD, 2013; Solo-Gabriele et al., 2020). 3.b.ii Ability of engineered landfill components to contain PFAS
Li (2011) investigated the effect of PFAS on sodium bentonite, a
PFAS-Containing Materials biodegradable organic matter, dissolved and suspended solids, heavy metals, ammonia, and sulfur compounds (Mukherjee et al., 2015; Renou et al., 2008). The waste type, age, climate at the landfill site, and methods of landfill operation dictate the characteristics of leachate. These factors result in highly variable leachate characteristics across landfill types and on a site-by-site basis within the different landfill types. Subtitle C hazardous waste landfills are required to use a leachate collection system during their active and post-closure care periods to mitigate adverse impact to human health and the environment. Since the use of leachate collection systems at Subtitle D landfills varies by landfill type and state requirements, the efficacy of leachate management and PFAS emissions depends on the controls implemented. PFAS containment in landfills is expected to be indefinite, so the generation of
PFAS-Containing Materials Treatment Technology Ozonation/ ozofractionation Fenton oxidation Photocatalytic advance oxidation process Treatment Mechanism Pros for PFAS Treatment Cons for PFAS Treatment References Oxidation • Potentially effective multi-contaminant removal • Potential sideproduct formation • Secondary treatment required Franke et al. (2019), Lin et al. (2012), Rahman et al. (2014), Ross et al. (2018) Oxidation Limited data available Limited data available None identified Oxidation • Permanent degradation • Potential sideproduct formation • Cost Lockwood (2018), Ross et al. (2018) Coagulationflocculation Precipitation Limited data available Limited data available Bao (2014), Dickenson & Higgins (2016), ITRC (2018), Rahman et al. (2014) Chemical precipitation Precipitation Limited data available Limited data available None identified Air stripping Volatilization More research needed • Potential secondary emissions None identified Physical separation • Commonly used • Effective for short and long-chain PFAS • Secondary treatment required for highvolume concentrate • Membrane fouling Dickenson & Higgins (2016), Ross et al. (2018) Physical separation • Uses less energy than RO • Effective for shortand long-chain PFAS • Secondary treatment required Boo et al. (2018), Dickenson & Higgins (2016) • Not effective for
EPA (2020a) • Potential secondary emissions None identified • Oversaturation • Potential surface water contamination • Dependent on climate None identified Physical Processes Reverse osmosis (RO) Nanofiltration (NF) Ultrafiltration (UF); Physical microfiltration separation (MF) Climatic evaporation; thermal Volume Limited data available evaporation; reduction mist evaporation Other On-Site Management Methods Recirculation Containment
ITRC (2017), Yamada et al. (2005) None identified Limited data available • Limited by high concentrations of non-biodegradable organic matter Ross et al. (2018), Saez et al. (2008), U.S.
EPA (2020a) • Direct release of
EPA (2020a) Leachate management and treatment technologies Membrane treatments separate compounds from the leachate using mechanical filtration and pressure. Leachate passes through selective membranes (such as RO, NF, UF, and MF membranes) that divide it into two parts: permeate (which has passed through the membrane) and concentrate (which has not). The permeate and concentrate can then be treated as independent streams. The primary difference between these membranes is the pore size, which in turn affects the operating pressure and removal efficiency for different types of contaminants. RO is the most commonly used type of membrane for leachate treatment, while NF, UF, and MF are generally used in combination with other treatment technologies including RO. RO and NF are known to be effective in concentrating some PFAS, but UF and
MF have pores that are too large to limit the migration of most water-bound PFAS across the filtration membrane. Membrane fouling and a large amount of concentrate generation are two of the major drawbacks observed in implementing the membrane treatment system for landfill leachate and may be further complicated by high concentrations of PFAS (Dickenson & Higgins, 2016; ITRC, 2018; Ross et al., 2018).
PFAS-Containing Materials An adsorption process with activated carbon is used for targeted removal of organic matter at some landfill sites. Activated carbon is known to be effective at trapping some PFAS, but it may need to be combined with other treatment methods to manage the range of PFAS found in landfill leachate. Activated carbon is a non-selective treatment method, expected to be less effective in nutrient-laden effluents like landfill leachate. Once saturated, activated carbon needs to be reactivated through a pyrolysis process (see Section 3.a), collected as solid waste, or otherwise treated, with consideration of the PFAS concentration (ITRC, 2017). Leachate also may need to be pretreated before activated carbon treatment to avoid rapidly saturating the carbon. Methods using ozone, Fenton’s reagent, or advanced photocatalytic technologies are used to oxidize organic matter in the leachate. Ozone and hydrogen peroxide (H2O2) in combination with other oxidizing agents have been observed to remove up to 99 percent of chemical oxygen demand from leachate at different operating conditions (Renou et al., 2008) and may be effective at reducing or modifying certain
NMOC with a one-time performance test and operating parameters set during the test for the requisite flare temperature and flow rate. Combustion temperatures and duration may prove to be critical factors for destruction of PFAS in LFG. While on-site flare systems average 850°C (1,550°F) (U.S. EPA, 2008), engine and boiler systems may run cooler and have a lower destructive potential for PFAS (as indicated in the EPA boiler database). See Section 3.a for a more complete discussion on conditions required for PFAS destruction.
LFG condensate is a liquid that has condensed in the LFG collection system during the extraction of gas from the landfill. Gases with high concentrations of water vapor condense in traps staged throughout the network. Condensate contains volatile compounds and accounts for a relatively small percentage of flow from a landfill. Gas condensate is commonly collected and managed with the landfill leachate as liquid wastes. PFAS has been detected in LFG condensate, with perfluorobutanesulfonic acid (PFBS) being the dominant species at a concentration of 1,000 ng/L (Li, 2011). 3.b.v Potential for releases during landfilling Over time, the potential increases for certain pollutants to move into the environment beyond the footprint of the landfill. As water passes through the landfill, it may leach pollutants from the waste— including PFAS from PFAS-containing waste—and move them deeper. Controlled landfill leachate is collected and either reinjected, treated on-site, or sent to a POTW for off-site treatment. In the absence of leachate management systems, uncontrolled leachate releases occur when water travels through the waste, out of the landfill, and into groundwater or surface water (see Section 4).
LFG can also contain heavy metals, organic chemicals, and greenhouse gases and can produce explosive mixtures of gas in the vicinity of the landfill if not properly controlled (ATSDR, 2001). LFG capture technologies are widely used to control gaseous emissions from landfills. However, despite the active capture of LFG, a fraction of LFG is emitted directly to the environment through the landfill surface and other routes as fugitive losses (see Section 4). Even years after landfill closure, direct human and ecological exposure is possible if PFAS are emitted through the air, groundwater, or surface water, or if remaining waste is disturbed. Because landfills contain PFAS but are not designed to destroy these compounds, they represent a potential source of
Ideally, landfill areas could be used for other beneficial purposes after closure; this requires that potential risks from landfill contents be adequately managed. Direct exposure to PFAS from landfilled waste is possible for people living or working near landfills as a result of gaseous or water releases from the site. Additionally, if PFAS-containing wastes are present on trucks and moved to active cells, landfill employees are directly exposed on the job. Research has shown elevated concentrations of PFAS in landfill ambient air (Hamid et al., 2018). 3.b.vi Testing and monitoring
PFAS-Containing Materials Table 3-7. Average MSW Tipping Fees per Ton for States and Regions (EREF, 2019) Region/State Pacific Average Tipping Fee $73.03 Region/State Midwest Average Tipping Fee $48.87 Alaska $154.92 Wisconsin $65.00 Hawaii $112.33 Minnesota $63.52 Washington $89.08 Missouri $62.42 Nevada $74.20 Illinois $51.78 Oregon $71.28 Iowa $48.47 Idaho $68.71 Indiana $47.91 California $55.56 Ohio $44.35 Arizona $43.39 Michigan $41.97 Kansas $39.32 Nebraska $39.21 Northeast $66.53 Rhode Island $110.00 Delaware $85.00 New Jersey $81.91 Maine $78.50 New Hampshire $74.34 Florida $55.08 Maryland $68.57
INTERIM GUIDANCE FOR PUBLIC COMMENT Planned Research and Development on Destruction and Disposal Technologies for PFAS and PFAS-Containing Materials U.S. EPA (Environmental Protection Agency). (2020). Innovative Ways to Destroy PFAS Challenge. https://www.epa.gov/innovation/innovative-ways-destroy-pfas-challenge
https://doi.org/10.1080/10473289.2006.10464429
and Technology, 6, 1–7. https://pubs.acs.org/doi/10.1021/acs.estlett.8b00531
Management, 7(4), 513–541. https://doi.org/10.1002/ieam.258
products (pp. 1–24). Springer. https://doi.org/10.1007/978-3-642-21872-9_1
https://doi.org/10.1080/10643389.2019.1614848
http://dx.doi.org/10.1016/j.scitotenv.2016.10.130
foams. Chemosphere, 183, 53–61. https://doi.org/10.1016/j.chemosphere.2017.05.056
Chemosphere, 67, 2011–2019. https://doi.org/10.1016/j.chemosphere.2006.11.049
Science and Technology, 43, 6507–6514. https://pubs.acs.org/doi/10.1021/es9010465
http://dx.doi.org/10.1016/j.chemosphere.2014.06.069
https://pubs.acs.org/doi/10.1021/es049860w
872. https://pubs.acs.org/doi/10.1021/es051362f
and Technology, 42(10), 3710–3716. https://doi.org/10.1021/es703165m
Processes and Impacts, 20(12), 1680–1690. https://doi.org/10.1039/C8EM00368H
Technology, 40(23), 7350–7357. https://pubs.acs.org/doi/10.1021/es061025m
https://pubs.acs.org/doi/10.1021/es051798v
Management, 107, 191–200. https://doi.org/10.1016/j.wasman.2020.03.034
Technology Letters, 3(12), 415–419. https://pubs.acs.org/doi/abs/10.1021/acs.estlett.6b00398
252–253, 413–418. https://doi.org/10.1016/j.jhazmat.2013.03.016
https://doi.org/10.1016/j.envint.2014.04.013
https://doi.org/10.1016/j.chemosphere.2019.03.191
https://doi.org/10.1016/j.atmosenv.2008.05.012
Environmental Monitoring, 9(6), 530–541. https://doi.org/10.1039/B701417A
https://doi.org/10.1016/j.envpol.2019.06.118
https://doi.org/10.1021/ac015630d
Visualized Experiments (146), e59142. https://doi.org/10.3791/59142
Miguel, G. S., Lambert, S. D., & Graham, N. J. D. (2001). The regeneration of field-spent granularactivated carbons. Water Research, 35(11), 2740–2748. https://doi.org/10.1016/S00431354(00)00549-2
Chemistry. https://doi.org/10.1007/s00216-020-02658-w
https://doi.org/10.1021/acs.estlett.9b00196
Chemosphere, 110, 17-22. https://doi.org/10.1016/j.chemosphere.2014.02.037
https://doi.org/10.1080/00102209808952095
Engineering, 2(4), 426–437. https://doi.org/10.1016/J.ENG.2016.04.005
Environmental Science and Technology, 49(9), 5672–5680. https://doi.org/10.1021/es506234b