Attachment 1 ASHRAE Application, R-471A
Other documents for the same rulemaking (all, by stage)
References
OTHER ACUTE TOXICITY (for example, oral, dermal) None: Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 9.6.1.f
GLP (Yes/No) Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 Method Result/Conclusions Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 Additional Comment Reference 9.6.1h
GLP (Yes/No) Method Result/Conclusions Additional Comment Reference Key study Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 9.6.2a
OTHER TOXICITY – GENETIC TOXICITY Mutagenicity – In vitro bacterial: Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 Reference Clastogenicity – In vitro mammalian: Reference Mutagenicity – In vitro mammalian: Reference Genetic Toxicity – in vivo:
HFO-1336mzz(E) ATEL Value: Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 Toxicity Information Blend
ATEL calculated using ATEL-RCL spreadsheet version provided Jan 2015: Lethality Cardiac Anesthetic Effects Sensitization Component 4-hr LC50
NOEL LOEL EC50 NOEL LOEL ppm v/v ppm v/v ppm v/v ppm v/v ppm v/v ppm v/v Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 Section 9.7: Flammability Information Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 Flammability Information (ANSI/ASHRAE Standard 34-2019 Section 9.7 Flame Propagation Flammability Testing – Appendix B1 Conclusion Method The testing was performed per ASHRAE Standard 34-2019 test protocol (condition, apparatus and procedure) using the current method ASTM E681-09 annex A1. The testing was performed with the 0.4 s duration spark from the secondary of a 15 kV/30 mA illumination transformer. The electrodes were L shaped 1mm tungsten wire with a gap of ¼ inch. The igniter was place 1/3 diameter of the flask from the bottom of the flask. The vessel was a 12-liter flask. The test conditions were ambient, 60°C temperatures using 0.0088 g water/g dry air (50% RH air at 23°C). Criterion for flame propagation:
GO: Greater than 90 degree arc per ASHRAE 34-2019, B1.8
NO GO: Less than or equal to 90 degree arc Honeywell Application to ANSI/ASHRAE Standard 34 Submitted: December 2019 Figure 1. E681 flammability flask and burn/no burn criteria Material The material used was 99.8 % or better purity and was degassed by repeated freeze-pumpedthaw cycles until no evidence of air was seen on a vacuum gage. The range of mixture in air tested was such that if it were possible, flame propagation would have occurred. The WCFF1_LFL, by the largest Figures 2 and 3 show the WCFF1 has a larger amount of the flammable component . Thus, only WCF1 and WCFF1 compositions were tested for flammability. The percentage mass results of the refrigerant mixtures WCF1 and WCFF1 tested are shown below. Table 1. WCF and WCFF tested for flammability