Electronic Products; Performance Standard for Diagnostic X-Ray Systems and Their Major Components
The Food and Drug Administration (FDA) is proposing to amend the performance standard for diagnostic x-ray systems and their major components. The agency is taking this action to update the standard to account for changes in technology and use of radiographic and fluoroscopic systems as well as to fully utilize the currently accepted metric system of units in the standard. For clarity and ease of understanding, FDA is republishing the complete contents of the affected regulations. This action is being taken under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Safe Medical Devices Act of 1990 (SMDA).
Original sourceXML (328 KB)PDF (305 KB)
Other documents for the same rulemaking
References: 17 extracted, 9 linked to papers
Allisy, A. et al., "Fundamental Quantities and Units for Ionizing Radiation," ICRU Report No. 60, International Commission on Radiation Units and Measurements, Bethesda, MD, December 1998.
National Council on Radiation Protection and Measurements, "Medical X-Ray and Gamma-Ray Protection for Energies Up to 10 MeV, Equipment Design and Use," NCRP Report No. 33, Bethesda, MD, February 1, 1968.
Cranley, K., B. J. Gilmore, and G. W. A. Fogarty, "Data for Estimating X-Ray Tube Total Filtration," Institute of Physical Sciences in Medicine, Report No. 64, York, England, 1991.
Shope, T. B., "Radiation-Induced Skin Injuries From Fluoroscopy," RadioGraphics, vol. 16, pp. 1195-1199, September 1996.
Gagne, R. M., P. W. Quinn, and R. J. Jennings, "Comparison of Beam-Hardening and K-Edge Filters for Imaging Barium and Iodine During Fluoroscopy," Medical Physics, vol. 21, pp. 107-121, 1994.
Stern, S. H. et al., "Handbook of Selected Tissue Doses for Fluoroscopic and Cineangiographic Examination of the Coronary Arteries," HHS Publication FDA 95-8288, 1995.
Rudin, S. and D. R. Bednarek, "Spatial Shaping of the Beam: Collimation, Grids, Equalization Filters, and Region-of-Interest Fluoroscopy," A Categorical Course in Physics, RSNA 1995.
Solomon, E. et al., "Low-Exposure Scanning-Beam X-Ray Fluoroscopy System," SPIE, vol. 2708, pp. 140-149, 1996.
National Council on Radiation Protection and Measurements, "Quality Assurance for Diagnostic Imaging Equipment," NCRP Report No. 99, Bethesda, MD, December 30, 1988.
National Council on Radiation Protection and Measurements, "Medical X-Ray, Electron Beam and Gamma-Ray Protection for Energies up to 50 MeV," NCRP Report No. 102, Bethesda, MD, June 30, 1989.
Upton, A. C. et al., "Health Effects of Exposure to Low Levels of Ionizing Radiation: BEIR V," National Research Council, National Academy Press, Washington, DC, 1990.
Rosenstein, M. et al., "Handbook of Selected Tissue Doses for the Upper Gastrointestinal Fluoroscopic Examination," FDA Publication 92-8282, Rockville, MD, 1992.
Suleiman, O. H. et al., "Nationwide Survey of Fluoroscopy: Radiation Dose and Image Quality," Radiology, vol. 203, pp. 471-476, 1997.
Stern, S. H. et al., "Estimated Benefits of Proposed Amendments to the FDA Radiation-Safety Standard for Diagnostic X-ray Equipment," Poster presented at the 2001 FDA Science Forum, February 15-16, 2001.
National Council on Radiation Protection and Measurements, "Evaluation of the Linear-Nonthreshold Dose-Response Model for Ionizing Radiation," NCRP Report 136, Bethesda, MD, June 2001.
UNSCEAR 2000 Report to the General Assembly, with Scientific Annexes, "Sources and Effects of Ionizing Radiation," United Nations, 2000.
"Assessment of the Impact of the Proposed Amendments to the Performance Standard for Diagnostic X-Ray Equipment Addressing Fluoroscopic X-ray Systems," Food and Drug Administration, November 15, 2000.