DRO-ISG-2023-03
Other documents for the same rulemaking (all, by stage)
References
NRC (1989). “A Status Report Regarding Industry Implementation of Safety Parameter Display Systems” (NUREG-1342), Washington, DC: U.S. Nuclear Regulatory Commission, April 1989. ML090060858
NRC (1988). “Development and Utilization of the NRC Policy Statement on the Regulation of Advanced Nuclear Power Plants” (NUREG-1226). Washington, DC: U.S. Nuclear Regulatory
ML13253A431 NRC (1983). “Clarification of TMI Action Plan Requirements” (NUREG-0737, Supplement 1).
Washington, DC: U.S. Nuclear Regulatory Commission. January 1983. ML102560009
NRC (1981). “Human Factors Acceptance Criteria for the Safety Parameter Display System” (NUREG-0835). Washington, DC: U.S. Nuclear Regulatory Commission, October 1981. ML102520360.
Hughes (2022). “Safety Evaluations of Adaptive Automation: Suitability of Existing Review Guidance” (RIL-2020-06). Upton, NY: Brookhaven National
D’Agostino (2021). “Development of HFE Review Guidance for Advanced Reactors” (BNL Technical Letter Report F0028-04). Washington, DC: U.S. Nuclear Regulatory Commission, October 12, 2021. ML21287A088.
Higgins (2020). “Adaptive Automation: Current Status and Challenges” (RIL-2020-05). Upton, NY: Brookhaven National Laboratory, November 30, 2020. ML20176A199.
Anderson (2019). “The Development of Guidance for the Review of the Interfaces for Managing the Effects of Degraded Human-System Interface and Instrumentation and Control Conditions on Operator Performance” (NUREG/CR-7264). Washington, DC: U.S. Nuclear Regulatory Commission.
Higgins (2010). “Human-System Interfaces to Automatic Systems: Review Guidance and Technical Basis” (BNL Technical Report 91017-2010). Upton, NY: Brookhaven National Laboratory. B-43
Boggi, M. (NRC) (2008). “Human Factors Considerations with Respect to Emerging Technology in Nuclear Power Plants” (NUREG/CR-6947). Washington, D.C.: U. S. Nuclear Regulatory Commission. October 2008.
Pint (2021). “Corrosion in Sodium Fast Reactors” (TLR0RES/DE/CIB-CMB-2021-07). Oak Ridge, Tennessee: Oak Ridge National Laboratory, May 13, 2021. ML21116A231.
Whitus (2003). “Emerging Technologies in Instrumentation and Controls” (NUREG/CR-6812). Washington, DC: U.S. Nuclear Regulatory Commission, March 2003. B-44
APPENDIX C—SCREENING SELECTING HUMAN FACTORS ENGINEERING ACTIVITIES FOR REVIEW Screening is the process by which the reviewer selects for review those human factors engineering (HFE) activities that the applicant has conducted, or plans to conduct, in support of the license application. This appendix provides guidance to aid reviewers in applying the screening process to a review. Section C-1 of this appendix provides general guidance for screening. Section C-2 briefly summarizes HFE activities as described in NUREG-0711, Revision 3, “Human Factors Engineering Program Review Model,” issued November 2012 (NRC, 2012), and the objectives of those activities. Review of the HFE activity objectives can guide the application-specific selection of HFE activities for a given review. Section C-3 discusses several analytical challenges the reviewer might anticipate when reviewing HFE activities for advanced reactors, and section C-4 contains an example HFE activity selection for a combination of facility characteristics.
HFE activities that supported development of the alarm system (e.g., operating experience review, task analysis, and human-system interface (HSI) design). In determining which HFE activities to review for a given characteristic, the reviewer may find it useful to consult NUREG/CR-7202, “NRC Reviewer Aid for Evaluating the Human Factors Engineering Aspects of Small Modular Reactors,” issued June 2015 (NRC, 2015).
HFE within its scope. Accordingly, the applicant’s HFE activities supporting compliance with these requirements should be included in the scope of the review for all applications subject to these requirements. C-1.5 No Applicant Human Factors Engineering Activity for Selected Target It is possible the reviewer may find that the applicant has identified no HFE activities associated with the development or implementation of a target the reviewer has selected for the scope of the review. In such instances, the reviewer should confirm the importance of the target to the review, verify that there are no applicable HFE activities, and if none, understand the applicant’s basis for no application of HFE to the development or implementation of the target. If the reviewer finds a reason to keep the target within the scope of the review plan, the reviewer should identify appropriate functional or design acceptance criteria during the grading process (as described in appendix D) to apply during the review. For example, if there is no HFE activity, the reviewer might need to rely on NUREG-0700, Revision 3, “Human-System Interface Design Review Guidelines,” issued July 2020 (NRC, 2020b), or other design standards, or if necessary, request a performance-based validation (e.g., ISV). Exhibit C-1.1 NUREG-0711 Elements Impacted by Potential SMR Issues (Reproduced from NUREG/CR-7202 (NRC, 2015))
Luxat (2020). “Human Factors Considerations for Automating Microreactors.” Albuquerque, NM: Sandia National Laboratories. June 2020. Agencywide Documents Access and Management System (ADAMS) Accession No. ML20175A117.
Engela (2005). “Function allocation for industrial human-system interfaces.” In Proceedings of CybErg 2005. Johannesburg, South Africa: International Ergonomics Association Press.
NEI (2019). “Risk-Informed Performance-Based Technology Inclusive Guidance for Non-Light Water Reactor Licensing Basis Development” (NEI 18-04, Rev. 1). Washington, DC: Nuclear Energy Institute, August 2019.
NRC (2020a). “Acceptability of Probabilistic Risk Assessment Results for Risk-Informed Activities” (Regulatory Guide 1.200, Rev. 3). Washington, DC: U.S. Nuclear Regulatory
NRC (2020b). “Human-System Interface Design Review Guidelines” (NUREG-0700, Rev. 3).
Washington, DC: U.S. Nuclear Regulatory Commission, July 2020. ML20162A214.
NRC (2018). “An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis” (Regulatory Guide 1.174, Rev. 3).
Washington, DC: U.S. Nuclear Regulatory Commission, January 2018. ML17317A256.
NRC (2015). “NRC Reviewer Aid for Evaluating the Human Performance Aspects Related to the Design and Operation of Small Modular Reactors” (NUREG/CR-7202). Washington, DC: U.S. Nuclear Regulatory Commission, June 2015. ML15182A199.
Washington, DC: U.S. Nuclear Regulatory Commission, November 2012. ML12324A013.
NRC (2007a). “Guidance for the Review of Changes to Human Actions” (NUREG-1764, Rev. 1).
Washington, DC: U.S. Nuclear Regulatory Commission, September 2007. ML072640413.
NRC (2007b). “Demonstrating the Feasibility and Reliability of Operator Manual Actions in Response to Fire” (NUREG-1852). Washington, DC: U.S. Nuclear Regulatory Commission, October 2007. ML073020676
NRC (2001). “Integrated Safety Analysis Guidance Document” (NUREG-1513). Washington,
DC: U.S. Nuclear Regulatory Commission, May 2001. ML011440260
NRC (2000). “Standard Review Plan for the Review of an Application for a Mixed Oxide (MOX) Fuel Fabrication Facility” (NUREG-1718). Washington, DC: U.S. Nuclear Regulatory
Higgins (2010). “Human-System Interfaces to Automatic Systems: Review Guidance and Technical Basis” (BNL Technical Report 91017-2010). Upton, NY: Brookhaven National Laboratory. ML102720251
Roth, E., J. O’Hara, K. Dickerson, & N. Hughes, N. (2022). “Cognitive Task Analysis: Technical Basis and Guidance Development” (RIL 2020-07). Washington, DC: U.S. Nuclear Regulatory Commission. ML22087A406. C-19
NUREG-0711, Revision 3, “Human Factors Engineering Program Review Model,” issued November 2012 (NRC, 2012)
NUREG-0700, Revision 3, “Human-System Interface Design Review Guidelines,” issued July 2020 (NRC, 2020)
NUREG-1764, Revision 1, “Guidance for the Review of Changes to Human Actions,” issued September 2007 (NRC, 2007)
NRC’s HFE guidance is developed and updated using a standard methodology (NRC, 2008). A high priority is placed on establishing the internal and external validity of the guidance. “Internal validity” is the degree to which the guidelines are linked to a clear, well-founded, and traceable technical basis. “External validity” is the degree to which independent peer review supports the guidance. Peer review is a good method of screening guidelines for conformance to generally accepted HFE practices and to industry-specific considerations (i.e., for ensuring that the guidelines are appropriate based on practical operational experience in actual systems). When selecting criteria from standards or guidance documents other than those developed using the
DANU-ISG-2022-01, “Review of Risk-Informed, Technology-Inclusive Advanced Reactor Applications—Roadmap” (NRC, 2024), during preapplication interactions, an applicant could use a white paper to identify any consensus codes and standards or code cases it intends to use and identify any standards or code cases that have not been endorsed or previously accepted by the staff. For any such standards or code cases, the applicant should engage in preapplication discussions to identify areas where additional information may be needed in the application to support the proposed approach. Whether proposed by the applicant or selected by the reviewer, use of guidance or standards other than those developed or endorsed by the NRC should include the considerations discussed in this section and be chosen in consultation with the reviewer’s supervisor. Table D-1 lists references reviewers may find helpful as supplements or alternatives to
IEEE Std 1023-2004, “IEEE Recommended Practice for the Application of Human Factors Engineering to Systems, Equipment, and Facilities of Nuclear Power Generating Stations and Other Nuclear Facilities”
EPRI 1008122-2004, “Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification”
IEEE (2022). “IEEE Guide for Human Factors Applications of Computerized Operating Procedure Systems (COPS) at Nuclear Power Generating Stations and Other Nuclear Facilities (IEEE Std 1786-2022). Piscataway, New Jersey: The Institute of Electrical and Electronics Engineers, June 2022.
NRC (2024). “Review of Risk-Informed, Technology-Inclusive Advanced Reactor Applications— Roadmap” (DANU-ISG-2022-01). Washington, DC: U.S. Nuclear Regulatory Commission. March 2024. Access and Management System (ADAMS) Accession No. ML23277A139.
NRC (2008). “Human Factors Considerations with Respect to Emerging Technology in Nuclear Power Plants” (NUREG/CR-6947). Washington, DC: U.S. Nuclear Regulatory Commission, October 2008. ML083090338
NRC (2004). “Guidance for the Review of Changes to Human Actions” (NUREG-1764, Rev. 1).
Washington, DC: U.S. Nuclear Regulatory Commission, September 2007. ML072640413 D-10
Washington, DC: U.S. Nuclear Regulatory Commission, July 2020. Access and Management System (ADAMS) Accession No. ML20162A214