National Institute for Occupational Safety and Health (NIOSH). 2020. NIOSH Manual of Analytical Methods (NMAM), 5th Edition.
Other documents for the same rulemaking (all, by stage)
References
Hocking AD, Pitt JI [1980]. Dichloran-glycerol medium for enumeration of xerophilic fungi from low-moisture foods. Appl Environ Microbiol 39(3):488-492.
Hodges LR, Rose LJ, O'Connell H, Arduino MJ [2010]. National validation study of a swab protocol for the recovery of Bacillus anthracis spores from surfaces. J Microbiol Methods 81(2):141-146.
Hodges LR, Rose LJ, Peterson A, Noble-Wang J, Arduino MJ [2006]. Evaluation of a macrofoam swab protocol for the recovery of Bacillus anthracis spores from a steel surface. Appl Environ Microbiol 72(6):4429-4430. Hogan CJ Jr., Kettleson EM, Lee MH, Ramaswami B, Angenent LT, Biswas P [2005]. Sampling methodologies and dosage assessment techniques for submicrometre and ultrafine virus aerosol particles. J Appl Microbiol 99(6):1422-1434.
Holmgren H, Bake B, Olin AC, Ljungstrom E [2011]. Relation between humidity and size of exhaled particles. J Aerosol Med Pulm Drug Deliv 24(5):253-260.
Hook-Barnard I, Norris SMP, Alper J [2014]. Technologies to enable autonomous detection for BioWatch: ensuring timely and accurate information for public health officials: workshop summary. Washington DC: Institute of Medicine.
HUD [2008]. Vacuum dust sample collection protocol for allergens. Washington, DC: Department of Housing and Urban Development, http://portal.hud.gov/hudportal/documents/huddoc?id=DOC_12539.pdf.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-78 of BA-115 Sampling and Characterization of Bioaerosols
Hung LL, Miller JD, Dillon HK [2005]. Field guide for the determination of biological contaminants in environmental samples. Fairfax, VA: American Industrial Hygiene Association.
Hunter CA, Grant C, Flannigan B, Bravery AF [1988]. Mould in buildings: the air spora of domestic dwellings. Int Biodeterior 24(2):81-101.
Hussein T, Norros V, Hakala J, Petaja T, Aalto PP, Rannik U, Vesala T, Ovaskainen O [2013]. Species traits and inertial deposition of fungal spores. J Aerosol Sci 61(0):81-98.
Hyvarinen A, Hirvonen MR [2016]. Inflammatory potential in relation to the microbial content of settled dust samples collected from moisture-damaged and reference schools: results of HITEA study. Indoor Air 26(3):380-390.
Hyvarinen A, Vahteristo M, Meklin T, Jantunen M, Nevalainen A, Moschandreas D [2001]. Temporal and spatial variation of fungal concentrations in indoor air. Aerosol Sci Technol 35(2):688-695.
Ibach MJ, Larsh HW, Furcolow ML [1954]. Isolation of Histoplasma capsulatum from the air. Science 119(3080):71.
Ijaz MK, Brunner AH, Sattar SA, Nair RC, Johnson-Lussenburg CM [1985a]. Survival characteristics of airborne human coronavirus 229E. J Gen Virol 66(Pt 12):2743-2748.
Ijaz MK, Sattar SA, Johnson-Lussenburg CM, Springthorpe VS, Nair RC [1985b]. Effect of relative humidity, atmospheric temperature, and suspending medium on the airborne survival of human rotavirus. Can J Microbiol 31(8):681-685.
Ijaz MK, Zargar B, Wright KE, Rubino JR, Sattar SA [2016]. Generic aspects of the airborne spread of human pathogens indoors and emerging air decontamination technologies. Am J Infect Control 44(9 Suppl):S109-120.
IOM [2004]. Damp indoor spaces and health. Washington, DC: Institute of Medicine.
ISO [2003]. ISO 14698:2003 Cleanrooms and associated controlled environments -Biocontamination control. Geneva, Switzerland: International Organization for Standardization.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-79 of BA-115 Sampling and Characterization of Bioaerosols
ISO [2012]. ISO 13138:2012 Air quality -- Sampling conventions for airborne particle deposition in the human respiratory system. Geneva, Switzerland: International Organization for Standardization. Jacobs RR [1989]. Airborne endotoxins: an association with occupational lung disease. Appl Ind Hyg 4(2):50-56.
Jensen PA, Todd WF, Davis GN, Scarpino PV [1992]. Evaluation of eight bioaerosol samplers challenged with aerosols of free bacteria. Am Ind Hyg Assoc J 53(10):660-667.
Johansson E, Reponen T, Meller J, Vesper S, Yadav J [2014]. Association of Streptomyces community composition determined by PCR-denaturing gradient gel electrophoresis with indoor mold status. Environ Monit Assess 186(12):8773-8783. Johnson FB [1990]. Transport of viral specimens. Clin Microbiol Rev 3(2):120-131.
Johnston AM, Vincent JH, Jones AD [1985]. Measurements of electric charge for workplace aerosols. Ann Occup Hyg 29(2):271-284.
Jones RM, Brosseau LM [2015]. Aerosol transmission of infectious disease. J Occup Environ Med 57(5):501-508.
Jonges M, van Leuken J, Wouters I, Koch G, Meijer A, Koopmans M [2015]. Wind-mediated spread of low-pathogenic avian influenza virus into the environment during outbreaks at commercial poultry farms. PLoS ONE 10(5):e0125401.
Julian TR, Tamayo FJ, Leckie JO, Boehm AB [2011]. Comparison of surface sampling methods for virus recovery from fomites. Appl Environ Microbiol 77(19):6918-6925.
Kanaani H, Hargreaves M, Smith J, Ristovski Z, Agranovski V, Morawska L [2008]. Performance of UVAPS with respect to detection of airborne fungi. J Aerosol Sci 39(2):175189.
Karim YG, Ijaz MK, Sattar SA, Johnson-Lussenburg CM [1985]. Effect of relative humidity on the airborne survival of rhinovirus-14. Can J Microbiol 31(11):1058-1061.
Karlsson K, Malmberg P [1989]. Characterization of exposure to molds and actinomycetes in agricultural dusts by scanning electron microscopy, fluorescence microscopy and the culture method. Scand J Work Environ Health 15(5):353-359.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-80 of BA-115 Sampling and Characterization of Bioaerosols Kendrick B [2000]. The fifth kingdom, 3rd Edition. Newburyport, MA: Focus Publishing, R. Pullins Company.
Mark D, Riediger G, Prodi V [1997]. A collaborative European study of personal inhalable aerosol sampler performance. Ann Occup Hyg 41(2):135-153.
Kesavan J, Sagripanti JL [2015]. Evaluation criteria for bioaerosol samplers. Environ Sci Process Impacts 17(3):638-645.
Kesavan J, Schepers D, McFarland AR [2010]. Sampling and retention efficiencies of batchtype liquid-based bioaerosol samplers. Aerosol Sci Technol 44(10):817-829.
Kesavan JS, Schepers D, Bottiger J [2011]. Characteristics of twenty-nine aerosol samplers tested at U.S. Army Edgewood Chemical Biological Center (2000 - 2006). Aberdeen Proving
Kettleson E, Kumar S, Reponen T, Vesper S, Meheust D, Grinshpun SA, Adhikari A [2013].
Kettleson EM, Adhikari A, Vesper S, Coombs K, Indugula R, Reponen T [2015]. Key determinants of the fungal and bacterial microbiomes in homes. Environ Res 138:130-135.
Kilburg-Basnyat B, Metwali N, Thorne PS [2016]. Performance of electrostatic dust collectors (EDCs) for endotoxin assessment in homes: effect of mailing, placement, heating, and electrostatic charge. J Occup Environ Hyg 13(2):85-93.
Kilburg-Basnyat B, Peters TM, Perry SS, Thorne PS [2015]. Electrostatic dust collectors compared to inhalable samplers for measuring endotoxin concentrations in farm homes. Indoor Air 26(5):724-733.
King EM, Filep S, Smith B, Platts-Mills T, Hamilton RG, Schmechel D, Sordillo JE, Milton D, van Ree R, Krop EJ, Heederik DJ, Metwali N, Thorne PS, Zeldin DC, Sever ML, Calatroni A, Arbes SJ Jr., Mitchell HE, Chapman MD [2013]. A multi-center ring trial of allergen analysis using fluorescent multiplex array technology. J Immunol Methods 387(1-2):89-95.
Kissell FN, Sacks HK [2002]. Inaccuracy of area sampling for measuring the dust exposure of mining machine operators in coal mines. Mining Eng 54(2):33-39.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-81 of BA-115 Sampling and Characterization of Bioaerosols
Koncsag CI, Barbulescu A [2011]. Liquid-liquid extraction with and without a chemical reaction. In: El-Amin M, ed. Mass transfer in multiphase systems and its applications. Rijeka, Croatia: InTech. DOI: 10.5772/594. Koneman EW [1988]. Color atlas and textbook of diagnostic microbiology. Philadelphia: Lippincott.
Kujundzic E, Hernandez M, Miller SL [2006]. Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons. Indoor Air 16(3):216-226. Kuo Y-M [2015]. Field evaluation of sampling bias with plastic petri dishes for sizefractionated bioaerosol sampling. Aerosol Sci Technol 49(3):127-133.
Lacey J, Crook B [1988]. Fungal and actinomycete spores as pollutants of the workplace and occupational allergens. Ann Occup Hyg 32(4):515-533.
LeBouf R, Yesse L, Rossner A [2008]. Seasonal and diurnal variability in airborne mold from an indoor residential environment in Northern New York. J Air Waste Manag Assoc 58(5):684-692.
Lednicky J, Pan M, Loeb J, Hsieh H, Eiguren-Fernandez A, Hering S, Fan ZH, Wu C-Y [2016]. Highly efficient collection of infectious pandemic influenza H1N1 virus (2009) through laminar-flow water based condensation. Aerosol Sci Technol 50(7):i-iv.
Lee KS, Bartlett KH, Brauer M, Stephens GM, Black WA, Teschke K [2004a]. A field comparison of four samplers for enumerating fungal aerosols I. Sampling characteristics. Indoor Air 14(5):360-366.
Lee SA, Adhikari A, Grinshpun SA, McKay R, Shukla R, Reponen T [2006]. Personal exposure to airborne dust and microorganisms in agricultural environments. J Occup Environ Hyg 3(3):118-130.
Lee SA, Liao CH [2014]. Size-selective assessment of agricultural workers' personal exposure to airborne fungi and fungal fragments. Sci Total Environ 466-467:725-732.
Lee SA, Willeke K, Mainelis G, Adhikari A, Wang H, Reponen T, Grinshpun SA [2004b]. Assessment of electrical charge on airborne microorganisms by a new bioaerosol sampling method. J Occup Environ Hyg 1(3):127-138.