National Institute for Occupational Safety and Health (NIOSH). 2020. NIOSH Manual of Analytical Methods (NMAM), 5th Edition.
Other documents for the same rulemaking (all, by stage)
References
Lee T, Lee EG, Kim SW, Chisholm WP, Kashon M, Harper M [2012]. Quartz measurement in coal dust with high flow rate samplers – Laboratory study. Ann Occup Hyg 56:413-425. Mine Safety and Health Administration (MSHA) [2013]. Infrared determination of quartz in respirable coal mine dust; Method No. P-7. Pittsburgh, PA: MSHA.
Larsen DJ, von Loenhoff LJ, Crable JV [1972]. The quantitative determination of quartz in coal dust by infrared spectroscopy. Am Ind Hyg Assoc J 33:367-372.
Freedman RW, Toma SZ, Lang HW [1974]. On-filter analysis of quartz in respiratory coal dust by infrared absorption and x-ray diffraction. Am Ind Hyg Assoc J 35:411-418. [10]
[12] Ojima J [2003]. Determining crystalline silica in respirable samples by infrared spectrophotometry in the presence of interferences. J Occup Health 45:94-103.
[13] Talvitie NA [1951]. Determination of quartz in the presence of silicates using phosphoric acid. Anal Chem 23:623-626. [14]
QUARTZ IN RESPIRABLE COAL DUST BY IR (Redeposition): METHOD 7603, Issue 4, dated 25 July 2017 - Page 7 of 8 [16]
ASTM International [2014]. ASTM D7948, Standard test method for measurement of respirable crystalline silica in workplace air by infrared spectrometry. West Conshohocken, PA: ASTM International. [17]
Commerce, National Institute of Standards and Technology, https://www.nist.gov. Date accessed: July 25, 2017. [18]
Stacey P, Mecchia M, Verpaele S, Pretorius C, Key-Schwartz R, Mattenklott M [2014]. Differences between samplers for respirable dust and the analysis of quartz – An international study. In: Silica and associated respirable mineral particles (ASTM STP 1565); Harper M, Lee T, eds. W.
ISO [1995]. Air quality – Particle size fraction definitions for health-related sampling. Geneva, Switzerland: International Organization for Standardization. [20]
Verpaele S, Jouret J [2013]. A comparison of the performance of samplers for respirable dust in workplaces and laboratory analysis for respirable quartz. Ann Occup Hyg 57:54–62. [21]
Lee T, Chisholm WP, Kashon M, Key-Schwartz RJ, Harper M [2013]. Consideration of kaolinite interference correction for quartz measurements in coal mine dust. J Occup Environ Hyg 10:425-434. [22]
Ainsworth, SM [2005]. Infrared analysis of respirable coal mine dust for quartz: Thirty five years. J
Shulman SA, Groff JH, Abell MT [1992]. Performance of laboratories measuring silica in the Proficiency Analytical Testing program. Am Ind Hyg Assoc J 53:49-56. [24]
Boiano JM, Wallace ME, Sieber WK, Groff JH, Wang J, Ashley K [2000]. Comparison of three sampling and analytical methods for the determination of airborne hexavalent chromium. J Environ Monit 2:329- 333.
Ashley K, Andrews RN, Cavazos L, Demange M [2001]. Ultrasonic extraction as a sample preparation technique for elemental analysis by atomic spectrometry. J Anal At Spectrom 16:1147-1153.
Foote P, Wickman DC, Perkins JB [2002]. Back-up data report for determination of hexavalent chromium by HPLC with post-column derivatization, prepared under NIOSH Contract 2000-95-2955. Unpublished.
CHROMIUM, HEXAVALENT by Ion Chromatography: METHOD 7605, Issue 2, dated 10 March 2016 - Page 5 of 5 Eide ME [2000]. Hexavalent Chromium, Method No. W 4001. Salt Lake City, Utah: U.S. Department of Labor (USDOL), Occupational Safety and Health Administration (OSHA), Salt Lake Technical Center.
Ku JC, Eide M [1998]. Hexavalent chromium in the workplace atmosphere, OSHA ID -215 . Salt Lake
ISO [2005; reapproved 2010]. Method No. 16740 Workplace air - Determination of hexavalent chromium in airborne particulate matter - Method by ion chromatography and spectrophotmetric measurement using diphenyl carbazide. Geneva, Switzerland: International Organization for Standardization (ISO).
Arar EJ, Pfaff JD, Martin TD [1994]. Method 218.6, Revision 3.3. Cincinnati, Ohio: Environmental Monitoring Systems Laboratory, Office of Research and Development, U.S. Environmental Protection Agency.
NIOSH [1975]. Criteria for a recommended standard: occupational exposure to chromium (VI).
Wang J, Ashley K, Kennedy ER, Neumeister C [1997]. Determination of hexavalent chromium in industrial hygiene samples using ultrasonic extraction and flow injection analysis. Analyst 122:1307-1312. [10]
Ndung’u K, Djane N-K, Malcus F, Mathiasson L [1999]. Ultrasonic extraction of hexavalent chromium in solid samples followed by automated analysis using a combination of supported liquid membrane extraction and uv detection in a flow system. Analyst 124:1367-1372. [11]
Wang J, Ashley K, Marlow D, England EC, Carlton G [1999]. Field method for the determination of hexavalent chromium by ultrasonic and strong anion exchange solid phase extraction. Anal Chem 71:1027-1032. [12]
EC/IRMM [1997]. Certificate of analysis, CR M545: Cr(VI) and total leacheable Cr in welding dust loaded on a filter. Brussels: Commission of the European Communities, Institute for Reference Materials and Measurements.
[13] Burkart JA [1986]. General procedures for limit of detection calculations in industrial hygiene chemistry laboratory. Appl Ind Hyg, 1(3):153 -155.
EVALUATION: FULL OSHA: 0.05 mg/m3 NIOSH: 0.05 mg/m3 Issue 1: 15 January 1998 Issue 3: 17 February 2016
LEAD BY PORTABLE ULTRASONIC EXTRACTION/ASV: METHOD 7701, Issue 3, dated 17 February 2016 - Page 2 of 5
Ashley K, Mapp KJ, Millson M [1998]. Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples. Am Ind Hyg Assoc J 59:671-679.
Ashley K, Song R, Esche CA, Schlecht PC, Baron PC, Wise TJ [1999]. Ultrasonic extraction and portable anodic stripping voltammetric measurement of lead in paint, dust wipes, soil, and air: An interlaboratory evaluation. J Environ Monit 1:459-464.
Sussell A, Ashley K [2002]. Field measurement of lead in workplace air and paint chip samples by ultrasonic extraction and portable anodic stripping. J Environ Monit 4:156-161. Ashley K [1994 ]. Electroanalytical applications in occupational and environmental health. Electroanalysis 6:805-820.
Ashley K, Wise TJ, Mercado W , Parry DB [2001]. Ultrasonic extraction and portable anodic stripping voltammetric measurement of lead in dust wipe samples. J Hazard Mater 83:41-50.
NIOSH [1994]. Lead: Method 7082, Lead by GFAAS: Method 7105, Elements: Method 7300. In: Eller PM,
ASTM [2003]. Standard Nos. E1613, E1741, E1775, E1979, E2051. In: Annual Book of ASTM Standards, Vol. 04.11. W. Conshohocken, PA: ASTM International. [11]
ASTM [2003]. Standard No. D1193: Specification for reagent water. In: Annual Book of ASTM Standards, Vol. 11.01. W. Conshohocken, PA: ASTM International. [12]
ASTM [2011]. Standard No. E1792: Standard specification for wipe sampling materials for lead in surface dust. In: Annual Book of ASTM Standards, Vol. 04.11. W. Conshohocken, PA: ASTM International. [13]
Ashley K, Harper M [2013]. Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces. J Occup Environ Hyg 10:D29-D33.
LEAD BY PORTABLE ULTRASONIC EXTRACTION/ASV: METHOD 7701, Issue 3, dated 17 February 2016 - Page 5 of 5
[1] NIOSH [1994]. Chromium, hexavalent: Method 7600. In: Eller PM, Cassinelli ME, eds. NIOSH manual of analytical methods. 4th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health,
[2] ASTM [2013]. Standard test method for the determination of hexavalent chromium in workplace air by ion chromatography and spectrophotometric measurement using 1,5-diphenylcarbazide: method D6832-13. West Conshohocken, PA: ASTM International. DOI: 10.1520/D6832-13.
[3] Marlow D, Wang J, Wise TJ, Ashley K [2000]. Field test of a portable method for the determination of hexavalent chromium in workplace air. Am Lab 32(15):26–28.
[4] Wang J, Ashley K, Marlow D, England EC, Carlton G [1999]. Field method for the determination of hexavalent chromium by ultrasonication and strong anion-exchange solid-phase extraction. Anal Chem 71(5):1027–1032.
[5] Wang J, Ashley K, Kennedy ER, Neumeister C [1997]. Determination of hexavalent chromium in industrial hygiene samples using ultrasonic extraction and flow injection analysis. Analyst 122(11):1307–1312.
[6] Foster RD, Howe AM, Cottrell SJ, Northage C [1996]. An investigation of the exposure of workers to hexavalent chromium in the air of plating works. Sheffield, UK: Health and Safety Executive, Health and Safety Laboratory, HSL Report IR/L/95/15.
[7] Molina D, Abell MT [1987]. An ion chromatographic method for insoluble chromates in paint aerosol. Am Ind Hyg Assoc J 48(10):830–835.
CHROMIUM, HEXAVALENT (Field-Portable Spectrophotometry): METHOD 7703, Issue 2, dated 20 October 2015 - Page 6 of 6
[8] Ndung’u K, Djane N-K, Malcus F, Mathiasson L [1999]. Ultrasonic extraction of hexavalent chromium in solid samples followed by automated analysis using a combination of supported liquid membrane extraction and UV detection in a flow system. Analyst 124(9):1367–1372.
[9] Health and Safety Executive [1988]. Total hexavalent chromium compounds in air—colorimetric laboratory method using 1,5-diphenylcarbazide: MDHS 61. In: Methods for the determination of hazardous substances. London: Health and Safety Executive.
[10] NIOSH [2013]. Criteria for a recommended standard: occupational exposure to hexavalent chromium. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH)