National Institute for Occupational Safety and Health (NIOSH). 2020. NIOSH Manual of Analytical Methods (NMAM), 5th Edition.
Other documents for the same rulemaking (all, by stage)
References
ISO [1995]. ISO 10312 Ambient air-determination of asbestos fibres-direct transfer transmission electron microscopy method. Geneva, Switzerland: International Organization for Standardization.
ISO [1999]. ISO 13794 Ambient air-determination of asbestos fibres-indirect transfer transmission electron microscopy method. Geneva, Switzerland: International Organization for Standardization.
ISO [2002]. ISO 14966 Determination of numerical concentration of inorganic fibrous particles-scanning electron microscopy method. Geneva, Switzerland: International Organization for Standardization. Jankovic JT [1985]. Asbestos bulk sampling procedure. Am Ind Hyg Assoc J 46:B8-B10.
Maynard A, Riediger G, Sahle W [2001]. Thoracic sampling of fibres. Contact research report 349/2001. Norwich, UK: Health and Safety Executive. Kauffer E [1989]. The French asbestos quality control scheme. In: Sixth International Colloquium on Dust Measurement Technique and Strategy. Jersey, Channel Islands: Asbestos International Association. Kenny LC [1984]. Asbestos fibre counting by image analysis-the performance of the Manchester asbestos program on Magiscan. Ann Occup Hyg 28:401-415.
LeGuen JMM, Ogden TL, Shenton-Taylor T, Verrill JF [1984]. The HSE/NPL phase-contrast test slide. Ann Occup Hyg 28:237-247.
Lilienfeld P, Elterman P, Baron P [1979]. Development of a prototype fibrous aerosol monitor. Am Ind Hyg Assoc J 40:270-282. Lippmann M [1988]. Asbestos exposure indices. Environ Res 46:86-106. Lippmann M [1990]. Effects of fiber characteristics on lung deposition, retention, and disease. Environ Health Perspec 88:311-317.
Huffman CB, Rodriguez-Macias F, Shon Y-S, Lee TR, Colbert DT, Smalley RE [1998]. Fullerene pipes. Science 280:1253-1256.
NIOSH Manual of Analytical Methods 5th Edition Chapter FI April 2016 Page FI-27 of FI-31 Measurement of Fibers
Lundgren L, Lundström S, Laszlo I, Westling B [1995]. Modern fibre counting-a technique with the phase-contrast microscope on-line to a Macintosh computer. Ann Occup Hyg 39:455-467.
Marijnissen J, Lilienfeld P, Zhou Y [1996]. A laser monitor for the fiber deposition in a lung model. J Aerosol Sci 27:S523-S524. Maynard AD [1996]. The development of samplers for size selective sampling of fibres: phase 2 report: selection and development of personal thoracic samplers. IR/A/96/11. Sheffield, UK: Health and Safety Laboratory. Maynard AD [1999]. Measurement of aerosol penetration through six personal thoracic samplers under calm air conditions. J Aerosol Sci 30:1227-1242. McCrone WC [1980]. The asbestos particle atlas. Ann Arbor, MI: Ann Arbor Science
Publishers, Inc. McCrone W, McCrone L, Delly J [1978]. Polarized light microscopy. Ann Arbor, MI: Ann Arbor Science Publishers, Inc. Middleton AP [1979]. The identification of asbestos in solid materials. In: Michaels L, Chissick
Morigi MP, Giacomelli GM, Prodi V [1999]. Mineral fibre sampling and size selection. Ann Occup Hyg 43:117-124.
NHMRC [1976]. Membrane filter method for estimating airborne asbestos dust. Woden, Australia: National Health and Medical Research Council.
NIOSH [1994a]. Asbestos (Bulk) by PLM: Method 9002. In: Eller PM, Cassinelli ME, eds.
NIOSH [1994b]. Asbestos by TEM: Method 7402. In: Eller PM, Cassinelli ME, eds. NIOSH manual of analytical methods. 4th ed. Cincinnati OH: U.S. Department of Health and Human
NIOSH Manual of Analytical Methods 5th Edition Chapter FI April 2016 Page FI-28 of FI-31 Measurement of Fibers
NIOSH [1994c]. Asbestos, chrysotile by XRD: Method 9000 In: Eller PM, Cassinelli ME, eds.
Ogden TL, Thomson DJ, Ellwood PA [1986]. Euparal and its use in measurement of asbestos. Microscope 34:173-179.
Pang TWS, Schonfeld-Starr FA, Patel K [1989]. An improved membrane filter technique for evaluation of asbestos fibers. Am Ind Hyg Assoc J 50:174-180. Perkins RL and Harvey BW [1993]. Method for the determination of asbestos in bulk building materials. Washington, DC: Environmental Protection Agency, EPA/600/R- 93/116.
Rajhans GS, Sullivan JL [1981]. Asbestos sampling and analysis. Ann Arbor, MI: Ann Arbor Science Publishers, Inc. Rickards AL [1978]. The routine monitoring of airborne asbestos in an occupational environment. Ann Occup Hyg 21:315-322.
Rooker SJ, Vaughan NP, LeGuen JM [1982]. On the visibility of fibers by phase contrast microscopy. Am Ind Hyg Assoc J 43:505-515.
Sahle W, Laszlo I [1996]. Airborne inorganic fibre level monitoring by transmission electron microscope (TEM): comparison of direct and indirect sample transfer methods. Ann Occup Hyg 40:29-44.
Schlecht PC, Shulman SA [1986]. Performance of asbestos fiber counting laboratories in the
Schneider T, Holst E, Skotte J [1983]. Size distribution of airborne fibres generated from manmade mineral fiber products. Ann Occup Hyg 27:157-171.
NIOSH Manual of Analytical Methods 5th Edition Chapter FI April 2016 Page FI-29 of FI-31 Measurement of Fibers
Selikoff IJ, Lee DHKE [1978]. Asbestos and disease. New York: Academic Press, Inc.
Steel EB, Small JA [1985]. Accuracy of transmission electron microscopy for the analysis of asbestos in ambient environments. Anal Chem 57:209-213. Stöber W [1972]. Dynamic shape factors of nonspherical aerosol particles. In: Mercer TT,
Taylor DG, Baron PA, Shulman SA, Carter JW [1984]. Identification and counting of asbestos fibers. Am Ind Hyg Assoc J 45:84-88.
Tombes, C, Calpin JA [2002]. A simple quality control system for evaluation of interlaboratory differences in fiber counting in accordance with NIOSH Method 7400. Am Ind Hyg Assoc J 49:A695-A697.
Vaughan NP, Rooker SJ, LeGuen JM [1981]. In situ identification of asbestos fibres collected on membrane filters for counting. Ann Occup Hyg 24:281-290. Walton WH [1982]. The nature, hazards, and assessment of occupational exposure to airborne asbestos dust: a review. Ann Occup Hyg 25:115-247.
Walton WH, Beckett ST [1977]. A microscope eyepiece graticule for the evaluation of fibrous dusts. Ann Occup Hyg 20:19-23.
Webber JS, Janulis RJ, Carhart LJ, Gillespie MB [1990]. Quantitating asbestos content in friable bulk sample: development of a stratified point-counting method. Am Ind Hyg Assoc J 51:447-452.
WHO [1985]. Reference methods for measuring airborne man-made mineral fibres (MMMF).
WHO [1986]. Asbestos and other natural mineral fibres. Geneva, Switzerland: World Health Organization.
WHO [1997]. Determination of airborne fibre number concentration: a recommended method by phase contrast optical microscopy (membrane filter method). Geneva, Switzerland: World Health Organization.
NIOSH Manual of Analytical Methods 5th Edition Chapter FI April 2016 Page FI-30 of FI-31 Measurement of Fibers Wylie AG [1979]. Fiber length and aspect ratio of some selected asbestos samples. In: Selikoff
NIOSH Manual of Analytical Methods 5th Edition Chapter FI April 2016 Page FI-31 of FI-31
NIOSH Manual of Analytical Methods (NMAM), 5th Edition Sampling and Analysis of Soluble Metal Compounds by Kevin Ashley, Ph.D., NIOSH and Richard Fairfax, CIH, OSHA [Much of this chapter was adapted from Fairfax and Blotzer 1994; and Ashley 2001.] Introduction Soluble and insoluble metal compounds Health effects Sampling considerations Analytical considerations
France, Germany, UK, USA) have established occupational exposure limits (OELs) for soluble metal and metalloid compounds [ACGIH 2015; IFA 2014]. Some examples of elements for which soluble OELs have been promulgated are listed in Table 1 (see Appendix for additional details). For many of these elements (e.g., Tl, Ag, Cr[VI], Ni, Pt), the OELs for the soluble compounds are lower than for the corresponding insoluble forms [ACGIH 2001; CRC 2015].
INRS 2014]. Efforts to harmonize sample preparation approaches have led to the promulgation of related consensus standards [Ashley 2015]. a. European standard Guidance on sample preparation methods for soluble metals and metalloids in workplace air has been promulgated recently in a European Standard [CEN 2009]. In these published methods and guidelines [NIOSH 1994; HSE 1998; BIA 1989; INRS 2014], two methodologies are generally favored for the extraction of “soluble” metal species: (1) extraction in pure water, or (2) extraction in diluted (~0.1 M) hydrochloric acid (HCl). In the European Standard [CEN 2009], both strategies are given as options for the dissolution of “soluble” metals in workplace air samples. Extraction of metals and metalloids in water is meant to reflect the chemical definition of “soluble” (as mentioned above), while extraction in diluted HCl is designed to mimic the dissolution of “soluble”
NIOSH Manual of Analytical Methods 5th Edition Chapter SM April 2016 Page SM-5 of SM-17 Sampling and Analysis of Soluble Metal Compounds metal compounds in stomach acid, which is highly acidic (pH 1). A temperature of 37 °C is recommended since this is normal body temperature. b. Extraction solvent A researcher in Germany [Hahn 2000] argued for the establishment of 0.1 M HCl in an operational definition for soluble metals in occupational hygiene samples and, also, specified mechanical agitation at 37 °C for two hours prior to sample analysis. An exception is made for thallium, which can form insoluble TlCl, in which case HCl is replaced by diluted nitric acid (HNO3). (A similar problem would arise if HCl were used as the extraction acid for soluble silver compounds.) The German extraction method for several soluble metal species [BIA 1989] is consistent with the strategy outlined [Hahn 2000], which attempts to address bioavailability by choosing HCl as the extraction acid.
However, in standard methods promulgated by the United States [NIOSH 1994], the United Kingdom [HSE 1998], and France [INRS 2014], deionized water is the solvent chosen in the operational definition of “soluble” for numerous metallic elements in workplace air samples. An exception to extraction in water is made for nickel [HSE 1998], where an ammonium citrate solution is specified as the leachate for soluble compounds of this element. Ammonium citrate provides buffering and chelating properties that are desirable for leaching soluble nickel compounds [HSE 1998]. c. Operational definitions Operational definitions of “soluble” metal species have been promulgated for consumer products such as toys, paper products, paints and art materials [ASTM 2014; CEN 2013;
ISO 2011]. Standard procedures for the extraction of metal compounds from consumer products are based on sample treatments in 0.07 - 0.14 M HCl (depending on the sample) for an hour at a temperature of 37 °C [Hahn 2000] or at room temperature [CEN 2013]. An ASTM International procedure (formerly the American Society for Testing and Materials) [ASTM 2014] is meant to provide an estimate of the bioavailability of several metals in art materials, using ~0.1 M HCl and extraction at body temperature. d. Quantity of solvent Another uncontrolled variable is the quantity of solvent used in laboratory analytical procedures for soluble metals at different laboratories. Different laboratories may (and do) use different amounts of deionized water for extraction. For example, one laboratory might use 10 mL of deionized water to extract the metal from a sample, while another lab may use anywhere from 25 to 100 mL to extract the compound. Depending upon the amount of material present in the sample, the procedure using 25 to 100 mL can dissolve a larger mass of solute than that using 10 mL. A conservative analytical method for metals used 15 mL of deionized water for extraction. This volume was chosen as a convenience
NIOSH Manual of Analytical Methods 5th Edition Chapter SM April 2016 Page SM-6 of SM-17 Sampling and Analysis of Soluble Metal Compounds and may not bear any relationship to what the body might absorb. Thus, two identical samples could produce two different results depending on the volume of solvent and other analytical parameters. A further factor affecting solubility is the particle size distribution of the sample: smaller particles are ordinarily more easily dissolved than larger ones. Thus for two samples having the same mass, the sample comprised of small particles may be more easily dissolved than a sample having large particles. 6 ISO procedure for soluble metals and metalloids Various procedures for the extraction of soluble metals and metalloids have been used for years, based on different operational definitions of solubility. The International Organization for Standardization, Technical Committee 146 on Air Quality, Subcommittee 2 on Workplace
NIOSH Manual of Analytical Methods 5th Edition Chapter SM April 2016 Page SM-10 of SM-17 Sampling and Analysis of Soluble Metal Compounds Disclaimer Mention of any company or product does not constitute endorsement by NIOSH. In addition, citations to websites external to NIOSH do not constitute NIOSH endorsement of the sponsoring organizations or their programs or products. Furthermore, NIOSH is not responsible for the content of these websites. All web addresses referenced in this document were accessible as of the publication date. 8 References
ACGIH [1987]. American Conference of Governmental Industrial Hygienists (ACGIH) Committee Activities and Reports – TLVs for Chemical Substances. Appl Ind Hyg 2:R4-R5.
ACGIH [2001]. Documentation of the Threshold Limit Values and Biological Exposure
ACGIH [2015]. Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices. Cincinnati, OH, USA: American Conference of Governmental Industrial Hygienists (ACGIH). Ashley K [1994]. Electroanalytical Applications in Occupational and Environmental Health. Electroanalysis 6:805-820. Ashley K [2001]. International Standard Procedure for the Extraction of Metal Compounds Having Soluble Threshold Limit Values. Appl Occup Environ Hyg 16:850- 853. Ashley K [2015]. Harmonization of NIOSH Sampling and Analytical Methods with Related International Voluntary Consensus Standards. J Occup Environ Hyg 12:D107-D115.
Ashley K, Applegate GT, Marcy AD, Drake PL, Pierce PA, Carabin N, Demange M [2009]. Evaluation of Sequential Extraction Procedures for Soluble and Insoluble Hexavalent Chromium Compounds in Workplace Air Samples. J Environ Monit 11:318-325.
ASTM [2013]. ASTM D6832, Standard Test Method for the Determination of Hexavalent Chromium in Workplace Air by Ion Chromatography ad Spectrophotometric Measurement Using 1,5-Diphenylcarbazide. West Conshohocken, PA, USA: ASTM International; [www.astm.org]. Date accessed: April 6, 2016.