National Institute for Occupational Safety and Health (NIOSH). 2020. NIOSH Manual of Analytical Methods (NMAM), 5th Edition.
Other documents for the same rulemaking (all, by stage)
References
Turgeon N, Toulouse MJ, Martel B, Moineau S, Duchaine C [2014]. Comparison of five bacteriophages as models for viral aerosol studies. Appl Environ Microbiol 80(14):4242-4250.
Unser S, Bruzas I, He J, Sagle L [2015]. Localized surface plasmon resonance biosensing: current challenges and approaches. Sensors (Basel) 15(7):15684-15716.
Usachev EV, Usacheva OV, Agranovski IE [2014]. Surface plasmon resonance-based bacterial aerosol detection. J Appl Microbiol 117(6):1655-1662.
USP [1997]. Microbiological evaluation of clean rooms and other controlled environments. Pharmacopeial Forum 23(6):5269-5295.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-97 of BA-115 Sampling and Characterization of Bioaerosols
Verreault D, Gendron L, Rousseau GM, Veillette M, Masse D, Lindsley WG, Moineau S, Duchaine C [2011]. Detection of airborne lactococcal bacteriophages in cheese manufacturing plants. Appl Environ Microbiol 77(2):491-497.
Verreault D, Moineau S, Duchaine C [2008]. Methods for sampling of airborne viruses. Microbiol Mol Biol Rev 72(3):413-444.
MT, Cox D, Dewalt G, Ashley PJ [2013]. Higher Environmental Relative Moldiness Index (ERMI) values measured in homes of asthmatic children in Boston, Kansas City, and San Diego. J Asthma 50(2):155-161.
Vesper S, McKinstry C, Haugland R, Wymer L, Bradham K, Ashley P, Cox D, Dewalt G, Friedman W [2007]. Development of an Environmental Relative Moldiness Index for US homes. J Occup Environ Med 49(8):829-833. Vincent JH [2005]. Health-related aerosol measurement: a review of existing sampling criteria and proposals for new ones. J Environ Monit 7(11):1037-1053. Vincent JH [2007]. Aerosol sampling: science, standards, instrumentation and applications.
Hoboken, NJ: John Wiley & Sons. Wagner J, Macher JM [2003]. Comparison of a passive aerosol sampler to size-selective pump samplers in indoor environments. Am Ind Hyg Assoc J 64(5):630-639.
Walls HJ, Ensor DS, Harvey LA, Kim JH, Chartier RT, Hering SV, Spielman SR, Lewis GS [2016]. Generation and sampling of nanoscale infectious viral aerosols. Aerosol Sci Technol 50(8):802-811.
Walter MV, Marthi B, Fieland VP, Ganio LM [1990]. Effect of aerosolization on subsequent bacterial survival. Appl Environ Microbiol 56(11):3468-3472.
Wang H, Reponen T, Lee SA, White E, Grinshpun SA [2007]. Size distribution of airborne mist and endotoxin-containing particles in metalworking fluid environments. J Occup Environ Hyg 4(3):157-165.
Wang Z, Reponen T, Grinshpun SA, Gorny RL, Willeke K [2001]. Effect of sampling time and air humidity on the bioefficiency of filter samplers for bioaerosol collection. J Aerosol Sci 32(5):661-674.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-98 of BA-115 Sampling and Characterization of Bioaerosols
Warren JC, Akers TG, Dubovi EJ [1969]. Effect of prehumidification on sampling of selected airborne viruses. Appl Microbiol 18(5):893-896.
Weber TP, Stilianakis NI [2008]. Inactivation of influenza A viruses in the environment and modes of transmission: a critical review. J Infect 57(5):361-373.
West JS, Atkins SD, Emberlin J, Fitt BD [2008]. PCR to predict risk of airborne disease. Trends Microbiol 16(8):380-387.
Whitehead T, Leith D [2008]. Passive aerosol sampler for particle concentrations and size distributions. J Environ Monit 10(3):331-335.
WHO [2009]. WHO guidelines for indoor air quality: dampness and mould. Geneva: World Health Organization.
Wilken JA, Marquez P, Terashita D, McNary J, Windham G, Materna B [2014]. Coccidioidomycosis among cast and crew members at an outdoor television filming event-California, 2012. MMWR Morb Mortal Wkly Rep 63(15):321-324.
Gilliss D, Ancock B, Prudhomme J, Gold D, Windham GC, Lee L, Materna BL [2015]. Coccidioidomycosis among workers constructing solar power farms, California, USA, 20112014. Emerg Infect Dis 21(11):1997-2005.
Willeke K, Lin X, Grinshpun SA [1998]. Improved aerosol collection by combined impaction and centrifugal motion. Aerosol Sci Technol 28(5):439-456.
Willeke K, Macher JM [1999]. Air sampling. In: Macher JM, ed. Bioaerosols: assessment and control. Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
Wurtz H, Sigsgaard T, Valbjorn O, Doekes G, Meyer HW [2005]. The dustfall collector--a simple passive tool for long-term collection of airborne dust: a project under the Danish Mould in Buildings program (DAMIB). Indoor Air 15(Suppl 9):33-40.
Yang W, Elankumaran S, Marr LC [2011]. Concentrations and size distributions of airborne influenza A viruses measured indoors at a health centre, a day-care centre and on aeroplanes. J R Soc Interface 8(61):1176-1184.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-99 of BA-115 Sampling and Characterization of Bioaerosols
Brami D, Zeigler-Allen L, Hoffman J, Goll JB, Fadrosh D, Glass J, Adams MD, Friedman R, Venter JC [2013]. A metagenomic framework for the study of airborne microbial communities. PLoS ONE 8(12):e81862.
Zhao Y, Aarnink AJ, Wang W, Fabri T, Groot Koerkamp PW, de Jong MC [2014]. Airborne virus sampling: efficiencies of samplers and their detection limits for infectious bursal disease virus (IBDV). Ann Agric Environ Med 21(3):464-471.
Zimmerman NJ, Reist PC, Turner AG [1987]. Comparison of two biological aerosol sampling methods. Appl Environ Microbiol 53(1):99-104.
Zuo ZL, Kuehn TH, Verma H, Kumar S, Goyal SM, Appert J, Raynor PC, Ge S, Pui DYH [2013]. Association of airborne virus infectivity and survivability with its carrier particle size. Aerosol Sci Technol 47(4):373-382.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-100 of BA-115 Sampling and Characterization of Bioaerosols 14 Appendix 1- List of manufacturers/distributors of common bioaerosol samplers and related products This list is not inclusive, and the inclusion of a specific product or company does not constitute endorsement by the National Institute for Occupational Safety and Health (NIOSH). If your bioaerosol equipment manufacturing or supply company is not listed or the information is incorrect or out-of-date, please contact us and we will review your information for inclusion as the list is updated. Manufacturers/Distributors of Common Bioaerosol Samplers and Related Products A.P. Buck Inc. 7101 Presidents Drive, Suite 110
Rickmansworth, Hertfordshire WD3 1PJ England Phone: +44 (0) 1923 773134 Fax: +44 (0) 1923 774790 http://www.burkard.co.uk Climet Instruments Company 1320 W. Colton Avenue
Boulder, CO 80301 USA Phone: (303) 440-5576Fax: (303) 4401965 http://www.dropletmeasurement.com March 2017 Page BA-101 of BA-115 Sampling and Characterization of Bioaerosols Manufacturers/Distributors of Common Bioaerosol Samplers and Related Products Continued Dycor Technologies, Ltd. 1851 94th Street
SKC, Inc. 863 Valley View Road Eighty Four, PA 15330 USA Phone: (800) 752-8472 Phone: (724) 941-9701 Fax: (724) 941-1369 http://www.skcinc.com March 2017 Page BA-102 of BA-115 Sampling and Characterization of Bioaerosols Manufacturers/Distributors of Common Bioaerosol Samplers and Related Products Continued Tecora 211-215 Rue la Fontaine 94134 Fontenay sous Bois Cedex, France Phone: Tel: +33 1 48 75 82 82 Fax: +33 1 48 75 82 96 http://www.tecora.com/en/ Thermo Scientific 27 Forge Parkway
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-103 of BA-115 Sampling and Characterization of Bioaerosols 15 Appendix 2 – Commonly used bioaerosol samplers This list is not inclusive, and the inclusion of a specific product or company does not constitute endorsement by the National Institute for Occupational Safety and Health (NIOSH). If a bioaerosol sampler is not listed or the information is incorrect or out-of-date, please contact us and we will review your information for inclusion as the list is updated.
NIOSH Manual of Analytical Methods 5th Edition Chapter FP April 2016 Page FP-3 of FP-14 Filter Pore Size and Aerosol Sample Collection a filter, they are giving the actual pore diameter for capillary pore filters and the equivalent pore diameter for other types of filters. The equivalent pore diameter is commonly measured by a “bubble-point test” [ASTM 2011]. This test is fairly simple, is non-destructive, and provides a good quality-control check for the filter. A bubble-point test works like this: Imagine that you have an ideal capillary pore filter with smooth holes that are of a uniform diameter, as shown in Figure 2. Now imagine that there is air on one side of this filter and a liquid that wets the filter on the other side. If the air pressure is low, the surface tension of the liquid will stop the air bubble from being pushed through the filter. If you slowly increase the air pressure, at some point it will be high enough to overcome the surface tension, and a visible stream of air bubbles will be produced. This pressure is called the bubble point. The pore diameter can be calculated from the bubble-point pressure with this formula [Brock 1983]: Where: 𝐷𝐷 = 4𝛾𝛾 cos 𝜃𝜃 × 106 (Equation 1) D = pore diameter (micrometers) P = bubble-point air pressure (Pa) γ = surface tension of the liquid (N/m) θ = contact angle between the liquid and the filter material Figure 2: Principle of the bubble-point test.
NIOSH Manual of Analytical Methods 5th Edition Chapter FP April 2016 Page FP-7 of FP-14 Filter Pore Size and Aerosol Sample Collection Figure 5: Theoretical collection efficiencies of aerosol particle collection mechanisms for a fibrous filter 1 mm thick with 2 µm fibers and an air velocity of 10 cm/sec. Diffusioninterception interaction is the particle collection due to an enhancement of interception by particle diffusion. The filter surface is assumed to be horizontal with air flowing downward into it, which enhances sedimentation. Total shows the collection efficiency of the filter due to all mechanisms combined. Electrostatic collection is not included because it is very difficult to model. These calculations were based on “single-fiber efficiency” for filters, which is explained in more detail in Hinds [1999]. Figure is adapted from Hinds [1999]. 5 Aerosol filter efficiency and pore size
NIOSH Manual of Analytical Methods 5th Edition Chapter FP April 2016 Page FP-10 of FP-14 Filter Pore Size and Aerosol Sample Collection
NIOSH Manual of Analytical Methods 5th Edition Chapter FP April 2016 Page FP-11 of FP-14 Filter Pore Size and Aerosol Sample Collection Society for Testing and Materials) publish test methods for a variety of aerosols that include the characteristics of the filters to be used. For example, in the NIOSH Manual of Analytical
NIOSH Manual of Analytical Methods 5th Edition Chapter FP April 2016 Page FP-12 of FP-14 Filter Pore Size and Aerosol Sample Collection sponsoring organizations or their programs or products. Furthermore, NIOSH is not responsible for the content of these websites. All web addresses referenced in this document were accessible as of the publication date. 9 References
ASTM [2011]. Standard test methods for pore size characteristics of membrane filters by bubble point and mean flow pore test. ASTM F316 - 03(2011). West Conshohocken, PA:
ASTM. Barrett LW, Rousseau AD [1998]. Aerosol loading performance of electret filter media. AIHA J 59(8):532-539. Breuer D [2012]. Flow resistance of samplers for personal monitoring in work areas and requirements for sampling pump performance. J Occup Environ Hyg 9(2):D25–D32. Brock TD [1983]. Membrane filtration: a user's guide and reference manual. Madison, WI: Science Tech.
Burton NC, Grinshpun SA, Reponen T [2007]. Physical collection efficiency of filter materials for bacteria and viruses. Ann Occup Hyg 51(2):143–151.
Charvet A, Gonthier Y, Gonze E, Bernis A [2010]. Experimental and modelled efficiencies during the filtration of a liquid aerosol with a fibrous medium. Chemical Engineering Science 65(5):1875-1886.
Contal P, Simao J, Thomas D, Frising T, Callé S, Appert-Collin JC, Bémer D [2004]. Clogging of fibre filters by submicron droplets. Phenomena and influence of operating conditions. J Aerosol Sci 35(2):263-278.
Givehchi R, Tan Z [2014]. An overview of airborne nanoparticle filtration and thermal rebound theory. Aerosol Air Qual Res 14(1):45-63. Hinds WC [1999]. Aerosol technology: properties, behavior, and measurement of airborne particles. New York: John Wiley & Sons.
Isaacs KK, Rosati JA, Martonen TB [2005]. Mechanisms of particle deposition. In: Ruzer LS,
Raton, FL: CRC Press, pp. 75-99. NIOSH Manual of Analytical Methods 5th Edition Chapter FP April 2016 Page FP-13 of FP-14 Filter Pore Size and Aerosol Sample Collection
Lee KW, Liu BYH [1980]. On the minimum efficiency and the most penetrating particle size for fibrous filters. Journal of the Air Pollution Control Association 30(4): 377-381. Lippmann M [2001]. Filters and Filter Holders. In: Cohen BS, McCammon CS Jr., eds. Air Sampling Instruments for Evaluation of Atmospheric Contaminants. Cincinnati, OH: American Conference of Governmental Industrial Hygienists, pp. 281-314. Martin SB Jr., Moyer ES [2000]. Electrostatic respirator filter media: filter efficiency and most penetrating particle size effects. Appl Occup Environ Hyg 15(8):609-617.