Policy Replication

Verification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust

Federal Register2003-03-06 · DEPARTMENT OF LABOR; Mine Safety and Health Administration · Proposed Rule · 03-3941
Proposed rule; notice of public hearings; close of record.

This proposed rule supercedes the proposed rule published by MSHA on July 7, 2000. Under this proposed rule mine operators would be required to verify and periodically monitor, through sampling, the effectiveness of the dust control parameters for each mechanized mining unit (MMU) specified in the mine ventilation plan. For samples to be valid, the operator would be required to sample on a production shift during which the amount of material produced by a MMU is at or above the verification production level using only the dust control parameters listed in the ventilation plan. The use of approved powered, air-purifying respirators (PAPRs) and/or verifiable administrative controls would be allowed as a supplemental means of compliance when MSHA determines that all feasible engineering or environmental controls are being used. MSHA is also proposing to rescind operator compliance sampling in underground coal mines. The use of a personal, continuous dust monitor (PCDM), once developed and approved, could be used by an operator in conjunction with the dust control parameters specified in the mine ventilation plan. The proposed rule would significantly improve miners health protection by limiting the exposure of individual miners to respirable coal mine dust.

RIN 1219-AB14

Other documents for the same rulemaking (all, by stage)

2000-07-07 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2000-07-07 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2000-07-25 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust; Correction
2000-08-11 Federal RegisterDetermination of Concentration of Respirable Coal Mine Dust; Verification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2003-03-17 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust; Determination of Concentration of Respirable Coal Mine Dust
2003-04-01 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2003-05-29 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust
2003-07-03 Federal RegisterVerification of Underground Coal Mine Operators' Dust Control Plans and Compliance Sampling for Respirable Dust

References: 58 extracted, 11 linked to papers

Page 2Download these results: CSV · JSON
Johnson, 1976
otherNot linked to a paper · Section III.D.4.a. Selection of Respirators
Terry Spear, et al., 2000
otherNot linked to a paper · Section III.D.4.c. PAPR Protection Factor
NIOSH Respirator Decision Logic (May 1987)
research reportNIOSH respirator decision logic. (1987) · Section III.D.4.c. PAPR Protection Factor
Guide to Industrial Respiratory Protection (September 1987)
research reportNIOSH guide to industrial respiratory protection. (1987) · Section III.D.4.c. PAPR Protection Factor
Cecala, et al., (1981)
journal articleNot linked to a paper · Section III.D.4.c. PAPR Protection Factor
Howie, et al., 1987; Sherwood, 1991
journal articleNot linked to a paper · Section III.D.4.c. PAPR Protection Factor
Bhaskar, et al. (1994)
journal articleNot linked to a paper · Section III.D.4.c. PAPR Protection Factor
Spear (2000)
otherNot linked to a paper · Section III.D.4.c. PAPR Protection Factor
← Previous