Ballast 2004 EPA CSO Fact Sheet
Other documents for the same rulemaking (all, by stage)
References
EPA Office of Prevention, Pesticides, and Toxic Substances. 2002. “Definitions National Prevention Pollution Policy.” Retrieved November 22, 2002. http://www.epa.gov/p2/p2policy/definitions.htm.
EPA Office of Water. 1999. Combined Sewer Overflow Management Fact Sheet: Pollution Prevention. EPA 832-F99-038.
Ferguson, T. et al. 1997. “Rouge River National Wet Weather Demonstration Project: Cost Estimating Guidelines Best Management Practices and Engineering Controls.” Retrieved December 9, 2002. http://www.rougeriver.com/pdfs/stormwater/sr10.pdf. Land-of-Sky Regional Council. 2001. “Waste Reduction Partners Annual Report 2001.” December 10, 2002. (Retrieved July 10, 2003.) http://www.landofsky.org/publications/annual_report2001/ default.htm. Minnesota Pollution Control Agency (MPCA). 2002. “Household Hazardous Waste.” Retrieved November 25, 2002. http://www.pca.state.mn.us/waste/hhw.html#map. O&M-20 North Carolina Division of Pollution Prevention and Environmental Assistance (NCDPPEA). 2002. “Considerations for the Management of Discharge of Fats,
Oil, and Grease (FOG) to the Sanitary Sewer Systems.” Retrieved November 22, 2002. http://www.p2pays.org/ref/20/19024.pdf. Northern Virginia Planning District Commission (NVPDC). 1996. Nonstructural Urban BMP Handbook. Prepared for the Department of Conservation and Recreation/Division of Soil and Water Conservation.
Bartram, J., and G. Rees, eds. 2000. Monitoring Bathing Waters: A Practical Guide to the Design and Implementation of Assessments and Monitoring Programmes. London and New York: E&FN SPON.
Boehm, A.B., et. al. 2002. Decadal and shorter period variability and surf zone water quality at Huntington Beach, California. Environmental Science and Technology. 36:38853892. Citizens Environmental Research Institute (CERI). 1999. Assessment Strategy for Evaluating the Environmental and Health Impacts of Sanitary Sewer CSOs and SSOs from Separate Sanitary Sewers. EPA Cooperative Agreement CX824848-01-1.
EPA Office of Water. 1995. Combined Sewer CSOs and SSOs: Guidance for Nine Minimum Controls. EPA 832-B-95-003.
EPA Office of Wastewater Management. 1999. Combined Sewer CSOs and SSOs: Guidance for Monitoring and Modeling. EPA 832-B-99-002.
EPA Office of Water. 2001. Report to Congress: Implementation and Enforcement of the Combined Sewer Overflow Control Policy. EPA 833-R-01-003.
EPA Office of Water. 2001a. Source Water Protection Practices Bulletin: Managing Sanitary Sewer CSOs and SSOs and Combined Sewer CSOs and SSOs to Prevent Contamination of Drinking Water. EPA 916-F-01-032.
Water. 2001. National Coastal Condition Report. EPA 620-R01-005.
EPA Office of Research and Development. 2002a. TimeRelevant Beach and Recreational Water Quality Monitoring and Reporting. EPA 625-R-02-0017.
EPA Office of Environmental Informantion. 2002c. Guidance for Quality Assurance Project Plans (EPA QA/G-5).
EPA 240-R-02-009. EPA Office of Water. 2003. Guidelines establishing test procedures for the analysis of pollutants; analytical methods for biological pollutants in ambient water: Final rule. Federal Register 68, no. 139, July 21, 2003. King County Department of Natural Resources and Parks Wastewater Treatment Division. “The CSO Control Program.” Retrieved June 3, 2003. http:// www.dnr.metrokc.gov/wtd/cso/page02.htm. King County Department of Natural Resources and Parks Wastewater Treatment Division. March 2002. “Regional Wastewater Services Plan - Water Quality Report.” Retrieved October 1, 2003. http://dnr.metrokc.gov/wtd/rwsp/documents/WQ2002.pdf. King County Department of Natural Resources and
Parks Wastewater Treatment Division. 2002. “2001/2002 Combined Sewer Overflow Report.” Retrieved October 1, 2003. http://dnr.metrokc.gov/WTD/cso/2001-02-intro.htm.
Leecaster, M.K., and S.B. Weisberg. 2001. Effect of sampling frequency on shoreline microbiology assessments. Marine Pollution Bulletin 42:1150-1154. Southern California Coastal Water Research Project (SCCWRP). 2003. “Research Plan 2003-2004.” Retrieved July 7, 2003. http://www.sccwrp.org/about/rspln2003-2004.html. Inclusion of this technology description in this Report to Congress does not imply endorsement of this technology by EPA and does not suggest that this technology is appropriate in all situations. Use of this technology does not guarantee regulatory compliance. The technology description is solely informational in intent.
EPA Office of Water. 2002b. National Beach Guidance and Required Performance Criteria for Grants. EPA-823-B-02004. O&M-29 Sewer system maintenance practices (NJ Dept. of Environmental Protection).
TECHNOLOGY DESCRIPTION Collec tion System Controls Maximizing Flow to Treatment Plant Overview Maximizing the amount of wet weather flow transported to the wastewater treatment plant (WWTP) is a common technique for reducing the volume and frequency of CSO and SSO discharges. Maximizing the use of existing facilities to treat wet weather flows that would otherwise overflow without treatment is constructive in all circumstances. The various technologies available for maximizing the amount of flow conveyed to the WWTP include minimum measures that can be implemented without capital investment, and more capital intensive projects that require planning, design, and construction. Maximizing flow to the WWTP is one of the nine minimum controls (NMC) established under EPA’s 1994
CSC-3 Report to Congress on the Impacts and Control of CSOs and SSOs percent removal requirement. Waivers are not available, however, from effluent concentration limits (EPA 1995).
WWTP for treatment. To garner information for PWD’s NMC program (and eventually the long term control plan), PWD instituted a $6.5 million project to upgrade its comprehensive system flow monitoring network in its three drainage districts. This flow monitoring program provided information to monitor system performance and enhance operation of the system through existing infrastructure (PWD 1997).
DETROIT, MI Assessing Transport Capacity Responsible Agency: Detroit Water and Sewage Department Population Served: 3 million Service Area: 921 sq. mi. Sewer System: 3,000 mi. of sewer The WWTP for the City of Detroit receives wastewater via three interceptors. The city conducted an extensive study which rated its sewer system for both conveyance and storage of combined sewage. Rating the conveyance capacity involved determining the maximum amount of flow that can be transported by the primary trunk sewers and interceptors without raising water elevations in these sewers to levels that increase the risk of basement or street flooding. Historical information was used to establish these water levels throughout the CSS. In addition, design data at specific locations were used, and detailed risk evaluations were conducted at specific locations in the system. System rating included use of the Greater Detroit Regional Sewer System model to simulate flow throughout the sewer system for a range of storm events. Target water levels determined from the historic information were compared against the resulting water levels produced by the model. Flow rates, which predicted water levels equal to or less than target water levels, were used to establish the transport ratings. Trunk sewers and four interceptor sewers were rated separately (Sherrill et al. 1997). More information at http://www.wadetrim.com/resources/pub_conf_collrate.pdf
CSC-5 Report to Congress on the Impacts and Control of CSOs and SSOs References American Society of Civil Engineers (ASCE). 2000. Protocols for Identifying Sanitary Sewer Overflows. Prepared by Black & Veatch under EPA, Office of Wastewater Management Cooperative Agreement. EPA Cooperative Agreement #CX 826097-01-0. Reston, VA: ASCE.
EPA Office of Water. 1995. Combined Sewer Overflows– Guidance for Nine Minimum Controls. EPA 832-B-95-003.
Field, R., et al. 1994. Optimization of CSO Storage and Treatment Systems. Presented at “A Global Perspective for Reducing CSOs: Balancing Technologies, Costs, and Water Quality” Water Environment Federation (WEF) Specialty
Conference, Louisville, Kentucky. July 10-13, 1994. Massachusetts Water Resources Authority (MWRA). 2000.
MWRA Business Plan Strategy #17: Implement CSO Control Plan by FY09 - Draft. v. 1.2. Retrieved September 1, 2003 http://www.mwra.state.ma.us/org/busplan/17.pdf
MWRA. 2001. Facts about the Braintree-Weymouth Relief Facilities Project. Boston, MA: Massachusetts Water Resources Authority. Retrieved September 4, 2003 http://www.mwra.state.ma.us/03sewer/graphic/ braintreeweyFS01.pdf
CSC-6 NYSDEC. 2003. Wet Weather Operating Practices for POTWs with Combined Sewers: “Technology Transfer Document.” Retrieved September 1, 2003 http://www.dec.state.ny.us/website/dow/bwcp/ww_ techtran.pdf Philadelphia Water Department (PWD). 1997. CSO Documentation Long Term Control Plan. Submitted to: Pennsylvania Department of Environment Protection Bureau of Water Quality Management in partial fulfillment of NPDES Permit Nos. PA 0026689, 002662, 0026671 (January 27, 1997).
Sherrill, J.D., et al. 1997. Rating and Optimization of Collection System Transport and Storage. Presented at Water Environment Federation Technical and Exhibition Conference in Chicago, IL. October 18-22, 1997. Inclusion of this technology description in this Report to Congress does not imply endorsement of this technology by EPA and does not suggest that this technology is appropriate in all situations. Use of this technology does not guarantee regulatory compliance. The technology description is solely informational in intent.
Colas, H., et al. 2001. Operation and Performance of an Optimized Real time Control System for Wet Weather Pollution Control, Vulnerability of Water Quality in Intensively Developing Watersheds, Making the Case for High-Performance Integrated Control. Presented at the University of Georgia, Athens, Georgia, May 14-16, 2001.
Colas, H. BPR CSO. E-mail correspondence with LimnoTech, Inc., 2003. Washington, DC.
Field, R., Villenueve, E., Stinson, M.K. 2000. “Get Real!” Water Environment & Technology. Vol. 12, No. 4: 64-67.
Hwang, G., City of San Diego Metropolitan Wastewater Division (MWWD). Interview by Limno-Tech, Inc., February 2003. Washington, DC.
Schultz, N., et al. 2001. Milwaukee’s Experience in Collection System Controls. Proceedings of WEF Speciality
Washington, July 2001. Stevens, Pat, ADS Environmental Services. Interview by
Limno-Tech, Inc., January 2003. Washington, DC.
Swarmer, Bob, King County, WA Wastewater Treatment Division. Interview by Limno-Tech, Inc., December 2002.
Washington, DC. Toomer, K., Atlanta Department of Public Works. Interview by Limno-Tech, Inc., February 2003. Washington, DC.
Water Environment Research Foundation. 1999. Using Flow Prediction Technologies to Control Sanitary Sewer Overflows. Prepared by D. Bennett, et al. Project 97-CTS-8. Alexandria,
Limno-Tech, Inc., 2003. Washington, DC. CSC-13 A roof leader or down-spout connected to the sewer system (MMSD).
Arbour, Rick, and Ken Kerri. 1998. Collection Systems: Methods for Evaluating and Improving Performance. Prepared for EPA, Office of Water Programs, Municipal Permits and Operations Division and developed under EPA Grant No. CX924908-01-0. Sacramento, CA: California State University, Sacramento Foundation.
EPA Office of Water. September 1999. Combined Sewer Overflow Technology Fact Sheet: Inflow Reduction. EPA-F-99035. Narragansett Bay Commission (NBC). April 2000. Stormwater Attenuation Study - Technical Memorandum No. 3, Evaluation of Alternatives. Prepared by the Maguire Group Inc. Rhode Island: NBC. Water Environment Federation (WEF). 1999. Control of Infiltration and Inflow in Private Building Connections.
EPA. 2001. Report to Congress: Implementation and Enforcement of the Combined Sewer Overflow Control Policy. EPA/833-R-01-003.
EPA Office of Water. 2000. Progress in Water Quality: An Evaluation of the National Investment in Municipal Wastewater Treatment. EPA-832-R-00-008. Metropolitan Council Environmental Services (MCES). 1996. Separating Combined Sewers to Improve and Protect Mississippi River Water Quality: A TenYear Commitment, Annual Progress Report to the Public - Year Ten. St. Paul, MN: MCES and Cities of
Minneapolis, St. Paul, South St. Paul. The Narragansett Bay Commission (NBC). 2000. Storm Water Attenuation Study: Technical Memorandum No.3 Evaluation Alternatives. Prepared by MacGuire Group, Inc. Rhode Island: NBC. National Research Council (NRC), Committee on the Use of Treated Municipal Wastewater Effluents and Sludge in the Production of Crops for Human
Consumption. 1996. Use of Reclaimed Water and Sludge in Food Crop Production. The National Academies Press.
Pitt, R. et al. 2003. “The National Stormwater Quality Database (NSQD, version 1.0).” Retreived August 6, 2003. Tuscaloosa, AL: University of Alabama.http: //www.eng.ua.edu/~rpitt/Research/ms4/Paper/ Mainms4paper.html Inclusion of this technology description in this Report to Congress does not imply endorsement of this technology by EPA and does not suggest that this technology is appropriate in all situations. Use of this technology does not guarantee regulatory compliance. The technology description is solely informational in intent.
Therefore, sliplining is not always a completely trenchless technology, but it is much less intrusive than traditional dig-and-replace methods (EPA 1999). Also, sliplining is not applicable in force mains. Existing pipe Manhole Heated water Figure 2. Schematic of a cured-in-place technique (O’Brien and Gere 2002) manholes, making it a true trenchless technology, as shown in Figure 2. Existing pipe Spiral wound pipe with interlocking edges Figure 1. Schematic of a spiral wound lining. Cured-in-Place Pipe During CIPP rehabilitation, a flexible fabric liner coated with a thermosetting resin is inserted into the existing sewer and then cured (EPA 1999). The most common techniques for installing the liners are the winch-in-place and invert-in-place methods. In the former, a winch is used to pull the liner into place. The liner is then filled with air to push it against the existing pipe. When using the invert-in-place technique, the resin is applied to the inside of the liner. Water or air pressure is used to invert the liner so that the resin covered side “flips out” to meet the existing pipe. For both methods, heat is used to seal the liner to the pipe (EPA 1999). CIPP liners can be installed from existing
CSC-29 Report to Congress on the Impacts and Control of CSOs and SSOs complicate traditional dig-and-replace methods; trenchless technologies avoid underground utilities. Advantages of trenchless technologies include (EPA 1999): Reduced air pollution from construction equipment Fewer traffic detours Decreased construction noise Reduced vegetation disturbance Limited areas where safety concerns must be identified Table 1 highlights conditions for which various trenchless technologies are most applicable. Trenchless technologies are not without limitations, however, and they are summarized in Table 2. Table 2. Disadvantages of trenchless sewer rehabilitation technologies (EPA 1999). Method Disadvantage Grouting and Epoxy Injections Sliplining Utilize harsh chemicals that may be dangerous for installation crews Will not prevent further pipe movement, and may crack if pipe shifts Requires an insertion pit Reduces pipe diameter ● Cannot be used with small diameter pipes Cost Selection of a cost-effective sewer rehabilitation technique depends on the present condition of the sewer and other site-specific considerations. In general, grouting is the least expensive of the sewer rehabilitation methods presented.
Further, trenchless sewer rehabilitation techniques are often less expensive than open-cut methods because the amount of excavation for the trenchless technology is minimal (EPA 1999). A representative range of costs for several trenchless technologies (CIPP, sliplining, and pipe bursting) is presented in Table 3; actual costs for sewer rehabilitation projects undertaken by a number of municipalities are summarized in Table 4. As shown in Table 4, there is considerable variation in the cost per foot for an individual technology; the diameter of the pipe drives much of this variation. Figure 4 illustrates the increase in cost of CIPP replacement as a function of increasing sewer diameter. Table3. Cost of selected trenchless technologies. Technology Cost ($/foot)