Deposition of Air Pollutants to the Great Waters-Second Report to Congress, Office of Air Quality Planning and Standards, June 1997, [EPA-453/R-97-011]. NOTE: WE HAVE THE THIRD REPORT IN THE DOCKET: Docket A-99-66, Document No. IV-A-06 [A-2000-02-IV-A-40]
Other documents for the same rulemaking
References
TSI DusTrak 0.83. Brauer and Mannetje (1998)
PM,„ 51-268 ng/m3. Lee and Chang (1999) Hong Kong Indoor and outdopr 5 classrooms
PM„, Indoor PM,,,: 30-470 ng/m3 Outdoor PMI0: 20-617 ng/m3 Chan (2002) A Hong Kong Office monitored indoor and outdoor
Temp, RH and solar intensity influence In/Out. Wind speed has no effect. Levy et al. (2002) Arbitrary choice of one library, coffee shop, urban shopping mall, food court, apartment, hospital, subway, diesel bus in Boston, MA
PM by volunteers in TRM in London, UK 16 lpm personal monitor. Porous foam size selector PM25 Volunteers rode/cycled along fixed routes repetitively. Personal exposures were generally double those at fixed-site ambient station. Subway exposures are maximal. Aim et al. (1999) Kuopio, Finland 9-km commuter route, rush hours 1/mo Climet 6 channels Windows closed, vents open air exchange rate 36-47 h"'. Morning commutes were generally higher than afternoon commutes; relationships determined between PM and wind speed and vehicle speed. Chan et al. (2002)
HiVol PM,„ PM,, andPM,,, Repetitive sampling over 8 fixed routes. Highly variable by mode. Tram exposures are maximal. Hoek et al. (2001) Hoek et al. (2002)
GIS used to interpolate background and regional ambient BS with added increment for distance to traffic < 50 m and < 100 m. May be useful technique. Estimates not validated with BS measurements at interpolated loci. Jinsart et al. (2002)
Bangkok, Thailand Sibata personal single nozzle 2.5 lpm PM2.5 and PM,0 Sampled 12-h while on duty at post at intersection. Exposures of both PM25 and PM10 higher than ambient PM measured at station with P gauge. Not comparable to U.S. conditions. Lena et al. (2002) PM25 and EC in the Bronx,
EEL for BS Sampled 10-h at sidewalk locations while counting cars and trucks for 3-weeks in summer of 1999.
EC is a large component of Diesel PM 2 , and varies with truck traffic. Zhu et al. (2002) Ultrafine near Interstate Highway in Los Angeles, CA with heavy Diesel traffic
COPD patients have (1) smaller personal clouds and (2) higher correlations between personal exposure and ambient concentrations compared to healthy elderly, children, and the general population. The analysis by Wallace (2000a) and three subsequent longitudinal studies June 2003 5-40
DRAFT-DO NOT QUOTE OR CITE TABLE 5-6. PAPERS REPORTING REANALYSES OF PARTICULATE MATTER EXPOSURE STUDIES Reference Study Cited Objectives/Hypotheses Findings Wallace (2000a)
PTEAM (Ozkaynak et al., 1990; Spengler et al., 1989; Wiener 1988, 1989; Wiener etal., 1990)
THEES (Lioy et al., 1990) Nashville COPD (Bahadori et al„ 2001) Amsterdam COPD (Janssen et al., 1997, 1998a) Boston COPD (Rojas-Bracho et al., 2000) Examines the differences between pooled and longitudinal correlations in personal and ambient (or outdoor) data for PM 2 . and PM,„. Median longitudinal correlation coefficient is much higher than the pooled correlation coefficient for the same data sets. Personal cloud for PMI0: 3-67 pg/m 3 ; PM 2 J 6-27 pg/m 3 . Personal cloud for elderly COPD was much smaller (PM, 0 : 611 ng/m 3 ; PM 25 = 6 g/m3) than for other healthy populations (PM,0: 27-56 pg/m3; PM 25 : 11-27 ng/m 3 ) of elderly, children, and the general population. However, correlations of personal exposure with ambient concentrations were not higher for elderly COPD than for other groups. Dockery and Spengler, 1981 Uses statistical modeling techniques to examine the relationship between ambient PM concentrations and personal exposures. Data analysis involves use of air exchange rates, penetration factors, and indoor/outdoor ratios, as well as examining exposure in various microenvironments (traveling, working, outdoors, indoors) activities (exposure to smoke, cooking), and source strengths. The important components of personal exposures are received during contact with indoor sources, mainly in homes and work places. Ozkaynak and Spengler (1996)
PTEAM (Ozkaynak et al., 1996a,b) Netherlands (Janssen et al., 1995) Discusses the personal cloud for PM 23 and PM, 0 . Hypothesizes that COPD patients have ( I ) smaller personal clouds (supported) and (2) higher correlations of personal exposure with outdoor concentrations because of reduced mobility (not supported). Ambient aerosols contribute about 50% or more to the personal
PM,„ exposures ofthe general population. The contribution of ambient aerosols to the total toxicity of inhaled particles is significant; Brown and Paxton (1998)
THEES (Lioy et al., 1990) PTEAM pilot (Wallace, 1996) Boston and Nashville COPD (Rojas-Bracho et al., 2000); Bahadori et al., 2001) Cross-sectional and longitudinal regression analysis on data sets. Individual personal PM exposure is subject to high variability, which makes the personal-to-ambient PM relationship difficult to predict. Wilson and Suh (1997) Philadelphia (Burton et al., 1996; Suggs and Burton, 1983) Determines the utility of fine and coarse PM concentrations as indicators of time-series epidemiology with regard to day-today variability, area uniformity, and indoor/outdoor PM ratios. Fine and coarse particles should be considered separate classes of pollutants.
EPA AIRS database Wilson et al. (2000) New Jersey (Lioy et al., 1990) Japan (Tamura et al., 1996a)
PTEAM (Clayton et al., 1993; Ozkaynak et al., 1996a,b) Netherlands (Janssen, 1998a; Suh etal., 1992) Necessary to treat personal exposure to ambient PM and personal exposure to nonambient PM as separate components of total personal PM exposure. Fixed-site ambient fine-particle measurements likely give a reasonable indication ofthe variability in the concentration of ambient fine particles across the community. Coarse-particle measurements most likely will not. Synoptic review of the "exposure paradox": Low correlations between personal exposure and ambient PM concentrations in spite ofthe existence of statistical association between ambient
PTEAM (Clayton et al., 1993; Ozkaynak etal., 1996a,b) Examines the influence of nonambient PM on total PM concentrations and how it may confound the outdoor/personal
PTEAM (Clayton et al., 1993; Ozkaynak et al., 1993, 1996a,b) Uses a reduced-form mass-balance model to predict the average fraction of ambient PM to which the average person is exposed. On average, a person is exposed to > 75% of ambient PM 25 and > 64% of ambient PM,„ measured by the community monitor.
Monn (2001) Multiple Literature Review To make an objective review of literature published since 1996 as an implicit update to the 1996 U.S. EPA PM AQCD. Emphasis on European studies. "It is important to note that a personal measurement does not a priori provide more valid data than a stationary ambient measurement, i.e. a personal sample in a study investigating effects from outdoor combustion particles is often influenced by sources other than outdoor sources and may thus confound the exposure-effect outcome." Exposure to ambient PM is highly correlated in time with ambient PM concentrations measured at a community site. Indoor PM does not confound the relationship between daily mortality and ambient PM. "Despite some lack of correlation between personal (PM 10 ) and outdoor values, outdoor fine particle concentrations were strongly associated with mortality and morbidity indicating that outdoor sources (e.g. vehicular emissions) emit the toxic entity (Dockerey et al., 1993; Schwartz et al., 1996)." Rotko et al. (2000a) Jantunen etal. (1998) Carrer etal. (1997)
Koistinenetal. (1999) To make a comparison of exposure relationships between the six EXPOLIS European cities (Athens, Basel, Grenoble,
Helsinki, Milan, Prague). Demographic bias exists because women and more-educated individuals are more likely to respond to survey. Socioeconomic bias exists in low SES subjects less likely to participate in diary keeping and exposure monitoring. Weighting is required for inter-city comparisons. Selection bias is not a problem for characterizing physical factors influencing personal exposure. Rotko et al. (2000b) Rotko et at. (2000a), Jantunen etal. (1998) To determine sociodemographic influences of exposure in Helsinki. Distinct male vs female differences: males had higher exposures to PM 2 5 , related to ETS, and a larger variance between sociodemographic groupings. No sociodemographic differences existed in outdoor PM2 5 concentrations. Lower occupational status contributed to greater PM 2 5 exposures than higher (professional) occupational status. Rodes et al. (2001)
EPA Baltimore and Fresno 1 and 2 To investigate relationships between the different retirement centers and identify most likely factors influencing personal and indoor concentrations. Mean personal exposure PM 2 . was higher than their apartment concentrations. Personal cloud of 3 ng/m 3 for PM 2 J was negligible but cloud for PM, 0 was 20 pg /m 3 . Indoor PM2 5 data were less than ambient concentrations. (Williams 2000a,b,c; Ebelt et al., 2000; Sarnat et al., 2000) supported hypothesis 1 but not hypothesis 2. Ozkaynak and Spengler (1996) showed that at least 50% of personal PM10 exposure for the general population comes from ambient particles. Wilson and Suh (1997) concluded that fine and coarse particles should be treated as separate classes of pollutants because of differences in characteristics and potential health effects. Wilson et al. (2000) gave a review of what they call the "exposure paradox" and determine that personal PM needs to be divided into different classes according to source type and that correlations between personal and ambient PM will be higher when nonambient sources of PM are removed from the personal PM concentration.
Mage (1998) conducted analysis using the PTEAM data and showed that the average person in PTEAM (Riverside, CA in the fall) was exposed to > 75% of ambient PM2 5 and > 64% of ambient PM10. Mage et al. (1999) used an algorithm to fill in missing data and outliers to analyzed data sets and show that variation in daily personal exposures for subjects
PM exposures and ambient PM concentrations. Of primary interest are the PM concentrations measured in ambient, indoor, and outdoor air; personal exposure measurements; the statistical correlations between measurements; and the attenuation and/or infiltration factors developed for June 2003 5-43
Abraham, J. L.; Siwinski, G.; Hunt, A. (2002) Ultrafine particulate exposures in indoor, outdoor, personal and mobile environments: effects of diesel, traffic, pottery kiln, cooking and HEPA filtration on micro-environmental particle number concentration. Ann. Occup. Hyg. 46(suppl. 1): 406-411.
Abt, E.; Suh, H. H.; Allen, G.; Koutrakis, P. (2000a) Characterization of indoor particle sources: a study conducted in the metropolitan Boston area. Environ. Health Perspect. 108: 35-44.
Abt, E.; Suh, H. H.; Catalano, P.; Koutrakis, P. (2000b) The relative contribution of outdoor and indoor particle sources to indoor concentrations. Environ. Sci. Technol. 34: 3579-3587.
Adams, H. S.; Nieuwenhuijsen, M. J.; Colvile, R. N.; McMullen, M. A. S.; Khandelwal, P. (2001) Fine particle (PMLS) personal exposure levels in transport microenvironments, London, UK. Sci. Total Environ. 279: 29-44.
Adgate, J. L.; Ramachandran, G.; Pratt, G. C; Waller, L. A.; Sexton, K. (2002) Spatial and temporal variability in outdoor, indoor, and personal PM2 5 exposure. Atmos. Environ. 36: 3255-3265.
W. (1985) Measuring human exposure to carbon monoxide in Washington, D.C, and Denver, Colorado, during the winter of 1982-1983. Environ. Sci. Technol. 19:911-918.
D. (2000) Personal exposures to PM and gaseous air pollutants at the end ofthe 1991 Kuwait oil fires. Presented at: PM2000: particulate matter and health—the scientific basis for regulatory decision-making, specialty conference & exhibition; January; Charleston, SC. Pittsburgh, PA: Air & Waste Management Association.
Aim, S.; Jantunen, M. J.; Vartiainen, M. (1999) Urban commuter exposure to particle matter and carbon monoxide inside an automobile. J. Exposure Anal. Environ. Epidemiol. 9: 237-244.
Q. (1998) Simultaneous indoor and outdoor particle light-scattering measurements at nine homes using a portable nephelometer. J. Exposure Anal. Environ. Epidemiol. 8:483-493.
Baek, S.-O.; Kim, Y.-S.; Perry, R. (1997) Indoor air quality in homes, offices and restaurants in Korean urban areas-indoor/outdoor relationships. Atmos. Environ. 31: 529-544.
Bahadori, T. (1998) Human particulate exposure assessment: relationship between outdoor, indoor, and personal measurements (air pollution) [dissertation]. Boston, MA: Harvard University.
Bahadori, T.; Suh, H. H.; Rojas, L.; Koutrakis, P. (1999) Characterization of personal PM10 and PM2.5 exposures for individuals with COPD: results from a pilot study in Nashville, TN. J. Exposure Anal. Environ. Epidemiol.: in press.
Bahadori, T.; Suh, H. H.; Rojas-Bracho, L.; Koutrakis, P. (2001) Personal exposure to particulate matter of individuals with chronic obstructive pulmonary disease (COPD). J. Exposure Anal. Environ. Epidemiol.: accepted.
Bohadana, A. B.; Massin, N.; Wild, P.; Toamain, J.-P.; Engel, S.; Goutet, P. (2000) Symptoms, airway responsiveness, and exposure to dust in beech and oak wood workers. Occup. Environ. Med. 57: 268-273.
Brauer, M.; Mannetje, A. (1998) Restaurant smoking restrictions and environmental tobacco smoke exposure. Am. J. Public Health 88: 1834-1836.
D. (1989) Personal exposures to acidic aerosols and gases. Environ. Sci. Technol. 23: 1408-1412.
D. (1990) Indoor and outdoor concentrations of acidic aerosols and gases. In: Indoor air '90: precedings ofthe 5th international conference on indoor air quality and climate, volume 2, characteristics of indoor air; July-August; Toronto, ON, Canada. Ottawa, ON, Canada: International Conference on Indoor Air Quality and Climate, Inc.; pp. 447-452.
Brauer, M.; Bartlett, K.; Regalado-Pineda, J.; Perez-Padilla, R. (1996) Assessment of particulate concentrations from domestic biomass combustion in rural Mexico. Environ. Sci. Technol. 30: 104-109.
R. (1999) Monitoring personal fine particle exposure with a particle counter. J. Exposure Anal. Environ. Epidemiol. 9: 228-236.
Cullen, A. (2000) Personal exposure to particles in Banska Bystrica, Slovakia. J. Exposure Anal. Environ. Epidemiol. 10: 478-487. June 2003 5-128
IV-12 Pollutants of Concern in the Great Waters Great Waters Pollutants of Concern and CAA Section 112 Summary of Water Quality Criteria Used for Comparison in This Report Comparison of Water Quality Criteria to Pollutant Concentrations in the Great Lakes Concentration of Total PCBs in Lake Superior Water Column Commercial Fishing Bans in the Great Waters Fish Consumption Advisories in the Great Lakes and Lake Champlain Fish Consumption Advisories in Selected Coastal Waters Eight-Year Trends of Pollutant Concentrations in Mussel Watch Project (1986-1993) Potential Effects of the Pollutants of Concern on Aquatic Life and Wildlife Potential Human Health Effects Associated Widi Pollutants of Concern Mean Serum PCB and DDT Levels in Fish Eaters and Controls
CHAPTER IV COASTAL WATERS A recent study of nutrient (i.e., nitrogen and phosphorus) and suspended solids loadings conducted for the Tampa Bay NEP suggests that direct atmospheric deposition of nitrogen to the tidal waters of Tampa Bay is the second largest source of nitrogen entering the Bay, contributing up to 28 percent of the total nitrogen load (Zarbock et al. 1994). The largest source of nitrogen, according to that study, is urban storm water runoff. A portion of the nitrogen entering the Bay from urban storm runoff represents atmospherically deposited nitrogen to impervious surfaces such as paved roads and sidewalks. These studies prompted the Tampa Bay NEP to revise its
Achman, D.R., K.C. Hornbuckle, and S.J. Eisenreich. 1992. Volatization of polychlorinated biphenyls from Green Bay, Lake Michigan. Environ. Sci. Technol. 27:75-87. Agency for Toxic Substances and Disease Registry (ATSDR). 1988. Toxicological profile for benzo(a)pyrene. U.S. Department of Health and Human Services, U.S. Public Health Services,