Federal Register, Requirements for Preparation, Adoption, and Submittal of implementation Plans; Final Rule, 40 CFR Parts 51 and 52, August 12, 1996, pp. 41838-41894 [A-92-55-I-F-7]
Other documents for the same rulemaking
References
AVACTA II is Gaussian segment/puff Briggs, open country (Gifford, 1975) model.
Briggs, urban, i.e., McElroy-Pooler (Gifford, e. Pollutant Types 1975)
AVACTA II can handle any couple of LO-LOCAT (MacCready et al.. 1974) User-specified function, with a user's primary-secondary pollutants (e.g., S0 2 and subroutine
Zannetti P., G. Carboni and A. Ceriani, 1985. AVACTA II Model Simulations of Worst-Case Air Pollution Scenarios in Northern Italy. 15th international Technical Meeting on Air Pollution Modeling and Its Application. St. Louis, Missouri, April 1519. B.2 Dense Gas Dispersion Model (DEGADIS) Availability The model code is only available on the Support Center for Regulatory Air Models Bulletin Board System (see Section B.O). Abstract
ENSR Consulting and Engineering. 1990. ERT Visibility Model: Version 4; Technical Description and User's Guide. Document M2020-003. ENSR Consulting and
Post, L. (ed.). 1994. HGSYSTEM 3.0 Technical Reference Manual. Shell Research Limited. Thornton Research Centre, Chester, United Kingdom. (TNER 94.059) Post. L., 1994. HGSYSTEM 3.0 User's Manual. Shell Research Limited, Thornton Research Centre, Chester, United Kingdom. (TNER 94.059) Availability The PC-DOS version ofthe HGSYSTEM software (HGSYSTEM: Version 3.0, Programs for modeling the dispersion of ideal gas and hydrogen fluoride releases, executable programs and source code can be installed from diskettes. These diskettes and all documentation are available as a package from API 1(202) 682-8340] or from NTIS as
Doug N. Blewitt. AMOCO Corporation, 1670 Broadway/MC 2018, Denver, CO, 80201,(303)830-5312. g. Plume Behavior
Howard J. Feldman, American Petroleum Briggs (1971) plume rise equations for final Institute. 1220 L Street Northwest, rise are used.
Washington, DC 20005, (202) 682-8340. Single source and hour is simulated. Unlimited number of lines-of-sight (receptors) is permitted per model run. h. Horizontal Wind Field A single wind speed and direction is specified for each case study. The wind is assumed to be spatially uniform. i. Vertical Wind Speed Vertical wind speed is assumed equai to zero. J. Horizontal Dispersion Rural dispersion coefficients from Turner (1969) are used. fc. Vertical Dispersion Rural dispersion coefficients from Turner (1969) are used. Mixing height is accounted for with multiple reflection handled by summation of series near the source, and Fourier representation farther downwind. /. Chemical Transformation First order transformations of sulfates and nitrates are used. m. Physical Removal Dry deposition is treated by the source depletion method. n. Evaluation Studies
Seigneur, C, R.W. Bergstrom and A.B. Hudischewskyj, 1982. Evaluation ofthe EPA
PLUVUE Model and the ERT Visibility Model Based on the 1979 VISTTA Date Base.
White, W.H., C. Seigneur. D.W. Heinold, M.W. Eltgroth, L.W. Richards. P.T. Roberts, P.S. Bhardwaja. W.D. Conner and W.E. Wilson. Jr., 1985. Predicting the Visibility of Chimney Plumes: An Inter-comparison of Four Models with Observations at a WellControlled Power Plant. Atmospheric
HEGADAS: This model adopts a for Geophysical Fluid Problems. Rev. method is equivalent to the random particle concentration similarity profile expressed in Geophys. Space Phys., 20: 851-875. method with a Gaussian kernel for particle terms of an unknown center-line groundYamada. T. and S. Bunker. 1988. distribution. The advantage of the puff level concentration and unknown vertical/ Development of a Nested Grid, Second method is the accuracy and speed of cross-wind dispersion parameters. These Moment Turbulence Closure Model and computation. The particle method requires quantities are determined from a number of Application to the 1982 ASCOT Brash Creek the release of a large number of particles basic equations describing gas-mass Data Simulation. Joumal of Applied which could be computationally expensive. conservation, air entrainment (empirical law Meteorology. 27: 562-578. The puff method requires the release of a describing vertical top-entrainment in terms much less number of puffs, typically Vio to Availability of global Richardson number), cross-wind '/too ofthe number of particles required by gravity spreading (initial gravity spreading For a cost to be negotiated with the model the particle method. followed by gravity-current collapse) and developer, a '/t-inch data cartridge or a 4mm The averaging time for concentration cross-wind diffusion (Briggs formula).
Bjorklund, J.R. and J.F. Bowers. 1982. User's Instructions for the SHORTZ and
LONGZ utilizes the steady-state univariate Gaussian plume formulation for both urban and rural areas in flat or complex terrain to calculate long-term (seasonal and/or annual) ground-level ambient air concentrations attributable to emissions from up to 14,000 arbitrarily placed sources (stacks, buildings and area sources). The output consists of the total concentration at each receptor due to emissions from each user-specified source or group of sources, including all sources. An option which considers losses due to deposition (see the description of SHORTZ) is deemed inappropriate by the authors for complex terrain, and is not discussed here. P.46 Federal Register / Vol. 61. No. 156 / Monday, August 12, 1996 / Rules and RegulaUons a. Recommendations for Regulatory Use
LONGZ applies user specified locations for sources and receptors. Receptors are assumed to be at ground level. g. Plume Behavior Plume rise equations of Bjorklund and Bowers (1982) are used. Stack tip downwash (Bjorklund and
Bowers, 1982) is included. All plumes move horizontally and will fully intercept elevated terrain. Plumes above mixing height are ignored. Perfect reflection at mixing height is assumed for plumes below the mixing height. Plume rise is limited when the mean wind at stack height approaches or exceeds stack exit velocity. Perfect reflection at ground is assumed for pollutants with no settling velocity. Zero reflection at ground is assumed for pollutants with finite settling velocity.
LONGZ does not simulate fumigation. Reference Brower. R. 1982. The Maryland Power Plant Siting Program (PPSP) Air Quality Model Users Guide. Ref. No. PPSP-MP-38. Prepared for Maryland Department of Natural Resources by Environmental Center, Martin Marietta Corporation, Baltimore, MD. (NTIS No. PB 82-238387) Weil. J.C. and RP. Brower. 1982. The Maryland PPSP Dispersion Model for Tall Stacks. Ref. No. PPSP-MP-36. Prepared for Maryland Department of Natural Resources by Environmental Center, Martin Marietta Corporation. Baltimore, MD. (NTIS No. PB 82-219155) Availability The model code and test data are available on diskette for a nominal cost to defray shipping and handling charges from: Mr. Roger Brower. Versar. Inc.. 9200 Rumsey Road. Columbia. MD 21045: Phone: (410) 964-9299. Abstract
PPSP is a Gaussian dispersion model applicable to tall stacks in either rural or urban areas, but in terrain that is essentially 41881 flat (on a scale large compared to the ground roughness elements). The PPSP model follows the same general formulation and computer coding as CRSTER, also a Gaussian model, but it differs in four major ways. The differences are in the scientific formulation of specific ingredients or "sub-models" to the Gaussian model, and are based on recent theoretical improvements as well as supporting experimental data. The differences are: (1) stability during daytime is based on convective scaling instead ofthe Turner criteria; (2) Briggs' dispersion curves for elevated sources are used: (3) Briggs plume rise formulas for convective conditions are included; and (4) plume penetration of elevated stable layers Is given by Briggs'(1984) model. a. Recommendations for Regulatory Use
Hanna. 1984. User's Guide to the Mesopuff
MESOPUFF II to Long Range Transport Problems, 1992. EPA Publication No. EPA454/R-92-021. U.S. Environmental Protection Agency. Research Triangle Park, Availability This model code is available on the Support Center for Regulatory Air Models Bulletin Board System and also on diskette (as PB 93-500247) from the National Technical Information Service (see Section B.O). Abstract
Plume Behavior Briggs (1975) plume rise equations are used, including plume penetration with buoyancy flux computed in the model. Fumigation of puffs is considered and may produce immediate mixing or multiple reflection calculations at user option. h. Horizontal Winds Gridded wind fields are computed for 2 layers: boundary layer and above the mixed layer. Upper air rawinsonde data and hourly surface winds are used to obtain spatially variable u.v component fields at hourly intervals. The gridded fields are computed by interpolation between stations in die
MESOPAC II preprocessor. i. Vertical Wind Speed Vertical winds are assumed to be zero. / Horizontal Dispersion a. Recommendations for Regulatory Use Incremental puff growth Is computed over There is no specific recommendation at the discrete time steps with horizontal growth present time. The model may be used on a parameters determined from power law case-by-case basis. equations fit to sigma y curves of Turner out b. Input Requirements to 100km. At distances greater than 100km. Required input data include four types: (1) puff growth is determined by the rate given by Heffter (1965). input control parameters and selected Puff growdi is a function of stability class technical options, (2) hourly surface fc. Vertical Dispersion meteorological data and twice daily upper air and changes in stability are treated.
Optionally, user input plume growth measurements, hourly precipitation data are Rural dispersion parameters are Briggs coefficients may be considered. optional. surface land classification (Gifford. 1975). with stability class defined information. (4) source and emissions data. fc. Vertical Dispersion by u/w* during daytime, and by the method Data from up to 25 surface National of Turner (1964). For puffs emitted at an effective stack Weather Service stations and up to 10 upper Urban dispersion is treated by changing all height which is less than the mixing height, air stations may be considered. Spatially stable cases to stability class D. uniform mixing ofthe pollutant within the variable fields at hour intervals of winds, mixed layer is performed. For puffs centered Buoyancy-induced dispersion (Pasquill, mixing height, stability class, and relevant above the mixing height, no effect at the 1976) is included (using AH/3.5). turbulence parameters are derived by ground occurs.
MESOPAC II, the meteorological /. Chemical Transformation preprocessor program described in die User /. Chemical Transformation Not treated. Guide. Hourly chemical rate constants are Source and emission data for up to 25 m. Physical Removal computed from empirical expressions point sources and/or up to 5 area sources can derived from photochemical model Not treated, be included. Required information are: simulations. location in grid coordinates, stack height, exit n. Evaluation Studies velocity and temperature, and emission rates m. Physical Removal Londergan. R.. D. Minott. D. Wackter, T. for the pollutant to be modeled. Dry deposition is treated with a resistance Kincaid and D. Bonltata. 1983. Evaluation of Receptor data requirements: up to a 40x40 method. Rural Air Quality Simulation Models, grid may be used and non-gridded receptor Wet removal may be considered if hourly Appendix G: Statistical Tables for PPSP. EPA locations may be considered. precipitation data are input. Publication No. EPA-450/4-83-003. Environmental Protection Agency, Research c. Output n. Evaluation Studies Triangle Park. NC. Line printer output includes: all input Results of tests for some model parameters Weil. J.C and R.P. Brower. 1982. The parameters, optionally selected arrays of are discussed in: Maryland PPSP dispersion model for tall ground-level concentrations of pollutant Scire. J.S., F.W. Lurmann. A. Bass and S.R.
Wang, I.T. and T.L. Waldron, 1980. User's Guide for MTDDIS Mesoscale Transport,
MTDDIS treats up to 10 point sources. Up to three rectangular receptor grids may be specified by the user. g. Plume Behavior Availability Briggs (1971. 1972) plume rise formulas are A diskette copy of the FORTRAN coding used. and the user's guide are available for a cost If plume height exceeds mixing height, of $100 from: Dr. I. T. Wang, Environmental Modeling & Analysis. 2219 E. Thousand Oaks ground level concentration is assumed zero. Fumigation and downwash are not treated. Blvd., Suite 435. Thousand Oaks. CA 91362. Abstract
Transoft Group. 1994. User's Guide of rate. For roadways, estimated traffic volume
Petersen, W.B. 1978. User's Guide for PAL—A Gaussian-Plume Algorithm for Point. Area, and Line Sources. EPA Publication No. EPA-600/4-78-013. Office of Research and Development, Research Triangle Park, NC. (NTIS No. PB 281306) Rao. K.S. and H.F. Snodgrass. 1982. PALDS Model: The PAL Model Including Deposition and Sedimentation. EPA Publication No. EPA-600/8-82-023. Office of Research and Development, Research Triangle Park. NC. (NTIS No. PB 83-117739) Availability The computer code is available on diskette (as PB 90-500802) from the National Technical Information Service (see Section B.O). Abstract
PEI Associates. 1988. User's Guide to SDM-A Shoreline Dispersion Model. EPA Publication No. EPA-450/4-88-017. U.S. Environmental Protection Agency. Research Triangle Park. NC. (NTIS No. PB 89-164305) Availability The model code is available on the Support Center for Regulatory Air Models Bulletin Board System (see Section B.O). Abstract
NWS surface and upper air meteorological data through the RAMMET preprocessor. Receptor data: coordinates for each receptor. c. Output Printed output includes the MPTER model output as well as: special shoreline P.53 41888 Federal Register / Vol. 61, No. 156 / Monday. August 12. 1996 / Rules and Regulations fumigation applicability report for each day and source; high-five tables on the standard output with "F" designation next to the concentration if that averaging period includes a fumigation event. d. Type of Model
Bjorklund, J.R. and J.F. Bowers. 1982. depletion by deposition). User's Instructions for the SHORTZ and d. Type of Model
SHORTZ may be used to model primary pollutants. Settling and deposition of particulates are treated. f. Source-Receptor Relationships User specified locations for sources and receptors are used. Receptors are assumed to be at ground level. g. Plume Behavior Plume rise equations of Bjorklund and Bowers (1982) are used. Stack tip downwash (Bjorklund and
Wackter, D. and R. Londergan. 1984. Evaluation of Complex Terrain Air Quality Simulation Models. EPA Publication No.
Ermak, D.L., S.T. Chan. D.L. Morgan and e. Pollutant Types L.K. Morris. 1982. A Comparison of Dense Pollutants are assumed to be non-reactive Gas Dispersion Model Simulations with and non-depositing dense gases or liquidBurro Series LNG Spill Test Results. J. Haz. vapor mixtures (aerosols). Surface heat Mails.. 6: 129-160. transfer and water vapor flux are also
Zapert, J.G., RJ. Londergan and H. Thistle. included in the model. 1991. Evaluation of Dense Gas Simulation Models. EPA Publication No. EPA-450/4f. Source-Receptor Relationships 90-018. U.S. Environmental Protection Only one source can be modeled at a time. Agency, Research Triangle Park, NC. There is no limitation to the number of B.19 WYNDvalley Model receptors; the downwind receptor distances Reference are internally-calculated by the model. The