EPA Air Pollution Control Cost Manual
Other documents for the same rulemaking
References
Group, Inc., and Bechtel Power Corporation. June 1997. Institute of Clean Air Companies (ICAC). Selective Catalytic Reduction (SCR) Control ofNOx Emissions, Prepared by the ICAC SCR Committee, November 1997. U.S. EPA. Analyzing Electric Power Generation Under the CAAA. EPA Office of Air and Radiation, March 1998.
Rurnmenhohl, V., H. Weiler, and W. Ellison. Experience Sheds Light on SCR O&M Issues. Power Magazine, September 1992.
Pritchard, S., C. DiFrancesco, and T.R. von Alten. SCR Catalyst Performance Under Severe Operating Conditions. Presented at Power-Gen International '96 Conference and Exhibition, ASME, Orlando, FL. December 1996.
Harmgart, S., M. Meierer, and J. Fahlke. In-Service Assessment ofDeNOx Catalysts. Presented at the International Joint Power Generation Conference and Exposition '98, ASME, Baltimore, MD, 1998.
Cochran, J.R., M.G. Gregory, and V. Rummenhohl. The Effect of Various Parameters on SCR System Cost. Presented at Power-Gen '93, the Fourth International Power Generation Exhibition & Conference, ASME, Dallas, Texas, November 1993. [ 1O] Electric Power research Institute. Technical Feasibility and Cost of Selective Catalytic Reduction (SCR) NOx Control. EPRI GS-7266, Final Report, May 1991. 2-59 [11]
Emissions, Baltimore, MD, February 24-26, 1993. [12]
Engineering, Inc., Windsor, CT, 1981. Sigling, R. and R. Johnson. Current Practices for Monitoring Ammonia Slip from
SCR Processes. Presented at the 1998 Conference on Selective Catalytic and Non-catalytic Reduction for NO" Control, U.S. Department of Energy, Federal Energy Technology Center, Pittsburgh, PA, May 21-22, 1998.
Cho, S.M. and S. Z. Dubow. Design of a Selective Catalytic Reduction System for NOx Abatement in a Coal-Fired Cogeneration Plant. Proceedings of the American Power Conference, Chicago, IL, pp. 717-722, April 1992. [15]
ANSI K-61.1-1989. Safety Requirements for the Storage and Handling of Anhydrous Ammonia. Compressed Gas Association, Arlington, VA, March 1989.
Broske, D., G. Offen, and E. Cichanowicz. An Assessment of European Experience with Selective Catalytic Reduction for NO X Control. Presented at the "NO X Controls for Utility Boilers Workshop," Baltimore, MD, August 1998, ("Proceedings: 1998 NOx Control Workshop," EPRI report number TR-1113561998.). [19]
Staudt, J.E. Status Report on NOx Control Technologies and Cost Effectiveness for Utility Boilers. Published by Northeast States for Coordinated Air Use Management (NESCAUM) and Mid-Atlantic Regional Air Management Association (MARAMA), June 1998.
[20] S.C. Stultz and J. B. Kitto, eds. Steam, Its Generation and Use. 40th edition, Babcock& Wilcox, Inc., Barberton, Ohio, 1992. [21]
Green, D.W. and R.H. Perry, eds. Perry's Chemical Engineers' Handbook. 6th edition, McGraw Hill, Inc., 1984. [22]
Durham, North Carolina, March 18-20, 1998.
[23] Electric Power Research Institute. Technical Assessment Guide. Vol. 1, Revision 7, 1993. [24]
TVA Paradise Unit 2, Presented at the Institute of Clean Air Companies ICAC Forum 2000, Washington D.C., March 23-24, 2000. [25]
Stenger, H. G., et al, Low Temperature Selective Catalytic Reduction of NO, Presented at the Institute of Clean Air Companies ICAC Forum 2000, Washington D.C., March 23-24, 2000. 2-61 EPN452/B-02-001 Section 5
Engineering, September 1990, pp. 116-121. LetterfromJoseL. Bravo ofJaegerProducts,Inc., to WilliamM. Vatavuk, U.S. Environmental Protection Agency, June 8, 1992.
Treybal, Robert E., Mass Transfer Operations (Third edition), McGraw-Hill Book Company,NewYork, 1980. Letter fromJackD. Brady of Anderson 2000, Inc., to WilliamM. Vatavuk, U.S. Environmental Protection Agency, June 9, 1992. Letter from S. Raymond Woll of Air Products, Inc., to William M. Vatavuk, U.S. Environmental Protection Agency, June 25, 1992.
Perry, R.H. and C.H. Chilton, Eds., Chemical Engineers' Handbook(Sixth edition), McGraw-HillBookCompany,NewYork, 1984.
Crowe, Charles R., and D. Cooper, "Brick/Membrane Linings Pass the Acid Test", Chemical Engineering, July 1988, pp. 83-86.
Harrison, MarkE., andJohnJ. France, "Distillation Column Troubleshooting, Part 2: Packed Columns", Chemical Engineering, April 1989, pp. 121-128. [ 1O]
Coker, AK., "Understanding the Basics of Packed-Column Design", Chemical Engineering Progress, November 1991, pp. 93-99. [ 11] Telephone conversation between Roy Oommen, Radian Corporation and Gerald
Nealon, Norton Process Equipment, April 4, 1992. [ 12] Gas absorber questionnaire responses from nine gas absorber vendors to Radian
CorporationAugust-December, 1991.
Pollutants, Volume I, CRC Press, Inc., Cleveland, Ohio, 1975. 1-44 [14]
Strigle, Ralph F ., Random Packings and Packed Towers, Design Applications, Gulf Publishing Company, Houston, Texas, 1987. [ 15] Questionnaire response from K. C. Lang ofLantec Products, Inc. To R. V. Oommen, Radian Corporation, August 23, 1991.
[16] Memorandum from Vatavuk, W.M. ofU.S. Environmental Protection Agency to Martha Smith, U.S.EPA,March27, 1992. [ 17] Packing vendor questionnaire responses from seven packing vendors to Radian
Corporation, August 1991 - January 1992. [18]
[19] Vatavuk, W.M.,andR.B.Neveril, "EstimatingCostsofPollutionControl Systems, Part II: Factors for Estimating Capital and Operating Costs", Chemical Engineering, November 3, 1980, pp. 157-162.
Agency, and Cindy Kling, City ofRaleigh, N.C., July 16, 1992.
[21] "Air Pollution Engineering Manual" (AP-40), (Second Edition), Danielson, John A., Los Angeles County Air Pollution Control District, CA, May 1973. For information on escalating these prices to more current dollars, refer to the EPA report Escalation Indexes for Air Pollution Control Costs and updates thereto, all of which are installedontheOAQPSTechnologyTransferNetwork(CTCBulletinBoard). 1-45 Appendix A Properties of Pollutants 1-46 Table 1. 7: List of Design Variables Variable Surface to voltune ratio of packing Cross-sectional area of absorber Abscissa value from plot ofgeneralized press drop correlation Absorption factor Diameter of absorber Diffusivity of pollutant in gas Diffusivity of pollutant in liquid Flooding factor Packing factor Waste gas flow rate entering absorber Waste gas flow rate exiting absorber Waste gas molar flow rate entering absorber Molar flow rate of pollutant free gas Waste gas superficial flow rate entering absorber Height of gas transfer mli.t Height ofliquid transfer unit Height of overall transfer unit Height of packing Height of absorber Pressure drop constants Symbol Units ft2/ft3 ft:2 Abscissa feet ft2/hr
Viner, A. S., G. P. Greiner, D. F. Furlong, and R. G. Hurst, Pilot-Scale Evaluation of Top-Inlet and Advanced Electrostatic Filtration, October 1986 (EPA-600/7-86-042).
York, 1985. 1-56 Turner, J. H., "Bag Filtration," in Handbook ofMultiphase Systems, ed. by G. Hetsroni,
Hemisphere, New York, 1982. Turner, J. H., and J. D. McKenna, "Control of Particles by Filters," in Handbook ofAir Pollution Technology, ed. by S. Calvert and E. Englund, John Wiley & Sons, New York, 1984.
Toronto, September 12 - 14, 1994, Air and Waste Management Association, Pittsburgh.
Broadway, R. M. and R. W. Cass, Fractional Efficiencyofa Utility Boiler Baghouse: Nucla Generating Plant, August 1975 (EPA-600/2-75-013-a [NITS PB 246 641]).
Cass, R. W. and R. M. Bradway, Fractional Efficiency ofa Utility Boiler Baghouse: Sunbury Steam Electric Station, March 1976 (EPA-600/2-76-077a [NTIS PB253 943]). [10]
Penny, C. W., Electrostatic Effects in Fabric Filtration: Volume 1. Fields, Fabrics, and Particles (Annotated Data), September 1978 (EPA-600/7-78-142A [NTIS PB 288576]). [ 11]
Frederick, E. R., Electrostatic Effects in Fabric Filtration: Volume 11. Triboelectric Measurements and Bag Performance, July 1978 (EPA600/7-78.1A2B [NTIS PB 287207]). [12]
Specification, Pittsburgh, 1987.
[13] Dennis, R., et al.. , Filtration Model for Coal Fly Ash with Glass Fabrics, August 1977 (EPA-600/7-77-084 [NITS PB 276489]). [ 14]
Dennis, R., and H. A. Klemm, "Modeling Concepts for Pulse Jet Filtration." JAPCA, 30(1), January 1980. [15]
Leith, D. and M. J. Ellenbecker, "Theory for Pressure Drop in a Pulse-Jet Cleaned Fabric Filter." Atm. Environment, 14, 1980, pp. 845-852. [ 16]
Koehler, J. L. and D. Leith, "Model Calibration for Pressure Drop in a Pulse-Jet Cleaned Fabric Filter," Atm. Environment, 17(10), 1983, pp. 1909-1913. 1-57 [17]
Viner, A. S., and B. R. Locke, Cost and Performance Models for Electrostatically Stimulated Fabric Filters, April 1984 (EPA 600/8-84-016). [ 18] Northrop Services, Inc. Fabric Filter Workshop Reference Materials, 1977 Workshop, Air Pollution Training Institute. [19]
Systems, Part XI: Estimate the Size and Cost ofBaghouses," Chemical Engineering, March 22, 1982, pp. 153-158. [20]
Frey, R. F., and T. V. Reinauer, "New Filter Rate Guide," Air Engineering, 30 April 1964. [21]
Owen, M. K. and A. S. Viner, Microcomputer Programs for Particulate Control, June 1985 (EPA-600/8-85-025a). [22]