Final Test Report, Portland Cement Emission Test: Holnam, Incorporated -Portland Cement Manufacturing Facility, Dundee, Michigan, November 15, 1994 [A-92-53-II-A-41]
Other documents for the same rulemaking
References
EPA directed Entropy to conduct an emissions test at the Holnam, Inc. Portland Cement manufacturing facility in Dundee, Michigan. The purpose of this test was to obtain emissions data from the Portland Cement manufacturing industry using fourier transform infrared (FTIR) spectroscopy, a multicomponent analytical technique, to identify hazardous air pollutants (HAPs) listed in Title I I I of the Clean Air Amendments. This emissions test was designed to obtain data to aid in the development of the maximum achievable control technology (MACT) standards for this source category. Portland Cement manufacturing processes are regulated for particulate matter. Therefore, the most common form of air pollution control devices (APCDs) used in this industry are baghouses and electrostatic precipitators (ESP's). Control efficiencies for hazardous air pollutants (HAP's) in these types of devices are not well defined. Holnam's facility in Dundee, Michigan operates a carbon injection system in conjunction with a baghouse to reduce opacity in the stack exhaust. Since the Dundee facility is the only cement kiln having this control technology, i t was chosen as a representative site for MACT testing. In September 1992, Entropy conducted a screening test under EPA Contract No. 68D10009, Work Assignment No. 1-97, utilizing the FTIR method at the
1. Neher, M.B., Jones, P., "In Situ Decomposition Product Isolated from Tenax While Sampling Stack Gases," Analytical Chemistrv. Vol 49, NO.3, March 1977.
ASTM Special Publication 934, (ASTM), 1987.
3. Vopicka, Easterling, and Haaland, "Multivariate Least-Squares Methods Applied to the Quantitative Spectral Analysis of Multicomponent Mixtures, Applied Spectroscopy. 39 (10), 73-84, 1985. P.60 P.61 Plant/Co.: Holnam Cement, Inc Plant Add.: Dundee. Michigan Traversing Location: Carbon Injection Inlet Number Of Traversing Pts (50 maxi: Duct/Stack Area, square inches: Barometric Pressure, in. Hg: Static Pressure, inches H20: Absolute Pressure, in. Hg: Molecular Wt. Dry, Ib/Ib-mole: Molecular Wt. Wet. Ib/Ib-mole: Fuel Factor. Fo: Volumetric Air Flow Rate, SCFM Dry: Average Axial Velocity, fps: Average Yaw Angle: Average Pitch Angle: Average Resultant Angle: Resultant Angle'Standard Deviation: Preliminary Run ID: Date: 06/30/93 Stan: 1130 Finish: 1330 Operator: EAP, RS Probe ID: 3D-11 Pitot Cp: 1.00 C02, %: 17.8 0 2 , %:
II); Anal. Chemistry 42, 945A (1975); Appl. Spectroscopy 444, pp. 211-215, 1990. C) Standard Practices for General Techniques for Qualitative Infrared Analvsis (American Society for Testing and Materials, Designation E 1252-88). D) "Traceability Protocol for Establishing True Concentrations of Gases Used for Calibration and Audits of Continuous Emissions Monitors (Protocol Number 1 ) , " June 1978, Quality Assurance Handbook for Air Pollution Measurement Systems. Volume III. Stationary Source Specific Methods. EPA-600/4-77-027b, August 1977. P.24
ASTM Standards. Part 23. ASTM Designation D 2028-71. Philadelphia. PA 1071. 5. Hanson. II. A., et ul. Particulate Sampling Strategies for I .urge Power Plants Including Nominllonu l'lou. USEPA. ORD.
NC. Publication No. EPA 600/2-76-170. June I87S. 350 p. 8. Urooks. E.P.. and Itl.. Williams. Flow and Oas Sampling Manual. U.S. Environmental Protection Agency. Research Triangle Park. NC. Publication No. EPA- 600/276-203. July 1976. 93 p. 8. Entropy Environmentalists. Inc. Traverse Point Study. EPA Counsel No. 1)0-03•<••»•• | , . n » t q l T |ti n Pl. 60, A p p . A , M e l h . I A Environmental Protection Agency 10. Urown. J. aud K Yu Test Heport: Par liculale Sampling btiaiecy In Cuculur Ducts. Emission Measurement Branch. Emission Standards and Engineering Division. U.S. Environmental Protection Agency. Research Triangle Park, NC. 27711. July 31. I960. 12 p. 11. Hawkslt-y. P G W, S liadziuch. and J.H. Blacketl Measurement of Solids In flue Oases. l«atherhead. England. The British Coal Utilisation Research Association. I90l.p. 129-133.
12. Knapp, KT'. The Numbel ol Sumpling Points Needed for Representative Source Sampling. In: Pioccedlngs of the fourth National Conlereuce uu Energy und the Environment, Theodore, I... el al. (ed.). Dayton. Dayton Section of the American Institute of Chemical Engineers. October 3-7. 1976. p. 563 566. 13. Smith. W.S. and ll.l drove A Pro posed Extension ol EPA Meihod I Criteria. "Pollution Engineering" XV (81:36-37. August 1883. 14. Gerharl. P.M. and MJ. Dnisey. Investigation of Field Test Procedures for Large Pans. University of Akron. Akron. OH. (EPRI Contract CS 1651). Final Report (RP-1649-5) December I9U0. 15. Smith. W.S. and D.J. Drove A New l.ook at Isokinetic Sampling- Theory and Applications. "Source Evaluation Society Newsletter." VllUiy.H) 24. August 1983.
2. VoUaro, Robert F. |{ccommended Pro cedure for Sample Traverses in Duels Smaller T h a n 12 Indies In Diameter. U.S. Environmental Protection Agency. Emission Measurement Branch. Research Triangle Park. NC. January 1977 M i l i u m 2 D i n H M I H A T I O N ui' S T A C K tins V M . ' I C I I V ANU V O I . U M L I I I I C Fi.ow l i t r e <Tvrs S P I T O T T U B E ) 1. Principle and Applicability 1.1 Principle. T h e uverage gas velocity in a stuck Is determined from I h e gits density • u d Irom measurement o l I In- average velocity head with a Type S (Stau.-.schclbe or reverse type) pilot tube. 1.2 Applicability. This met hod is upphra ble for measurement ul the aveiace vt-locily ol a gas stream und for quantifying gas flow. . This procedure is lint applicable at meas uremeut sites which fail to meet the criteria of Method I. Section 2.1. Also, d i e method cannot be used for direct measurement in cyclonic or swirling gas streams: Section J 4 of Method 1 shows how lo determine cyclonic or swirling flow conditions. W h e n unacceptable conditions exist, alternative pro cedurcs. subject lo the uppioval of l l u Ad minlstralor, U.S Environmental Protedion
EPA. March 30. 1983. NH. Interference in 3.8. Methods 7C and 7D. 3.3 Interference Response. The output 3. Quality Assurance Handbook for Air Pollution Meuurement 8ysten_. Volume respunaa of the meuurement aystem to a Pt. 60, App. A, Molh. • Environmental Protection Agoncy component in the sample g u . other than the g u component being measured. 4. Measurement System Performance Specifications Same u Method 6C. Sections 4.1 through 4.4. 8. Apparatus and Reazgtnts 5.1 Meuurement 8ystem. Any meuurement system for NO. that meets the specifications of thte method. A ocheraaUo of an acceptable meuurement aystem Is shown In Figure 6C-I of Method 6C. The essential componenu of the meuurement syatem are described below: 6.1.1 Sample Probe. Sample Line, Calibration Valve Assembly, Moisture Removal System. Particulate FUter, Sample Pump, Sample Flow Rate Control, 8ample O u
CO. EPA-330/I-79-003-R. Arthur Vf. Dyb- for devices meuuring In Ihe 1.600 to 3.000 dshl. current edition CNTI8 No. PB6I- ppm range For devices meuuring In the 0 2466821 to 100 ppm range. Interference ratios can be 8.1 Field Evaluation of Mobile Lldar for u high u 3.6 percent HX) per 35 ppm CO the Meuurement of Smoke Plume Opacity. and 10 percent CO, per 60 ppm CO. The UM U.8. Environmental Protection Agency. Na- of silica gel and aacarlie (raps will alleviate tional Enforcement Investigations Center. the major Interference problems. Tne measDenver. CO. EPA/NEIC-T8-12B. February ured gaa volume muat be corrected If these traps are used. 1976. 5.1 Remote Meuurement of Smoke 4. Precision and Accuracy Plume TranamltUnce Uaing Udar. C. B. 4.1 Precision. The precision of most NDIR Cook. a. W. Bethke. W. D. Conner (EPA/ analyzers te approximately rt percent of
RTP). Applied Optics 11. pg 1743. August span. 1972 4.3 Accuracy. The accuracy of most NDIR 84 Udar Studies of 8tack Plumes In Rural and Urban EnvlronmenU. EPA-430/ analysers Is approximately tt percent ol span after calibration. 4-73-002. October 1671. 6 6 American National Standard for the 8. Apparatus Safe UM of Users ANSI Z 136 1-176. March 6.1 Continuous Sample (Figure 10 1). 1.1676. 6.1.1 Probe. Stalnleu steel or aheathed 66 US. Array Technical Manual TB Pjrr«x' glass, equipped with a Hlter to
IMS. January 1976. 6.9 User Safely Handbook. Alex Mallow, To remove any exceu moisture. 8.2.1 Valve. Needle valve, or equivalent, to Uon Chabot. Van Nutrand Relnhold Co., to adjust flow rate. 1978. 6.14 Pump. Uak-free diaphragm type, or equivalent, to transport gu.
CO Analyser. Presented at litis Methods Conference on Air Pollution. University of California. Berkeley. CA. April 1. 1970. 3. Jacobs. M. B.. et al.. Contlnuoua Determination of Carbon Monoxide and Hydrocarbons In Air by a Modified Infrared Analyser. J. Air Pollution Control Association. 9(2): 110-114. August 1959.
3. MSA LIRA Infrared Ou and Uquid Analyzer Instruction Book. Mine Safety Appliances Co., Technical Products Division. PltUburgh. PA. 4. Models 216A. 3I5A. and 4ISA Infiared Analyzers. Beckman InsirumeiiU. Inc., Beckman Instructions 1638-B. Fullerton. CA. October 1967. 6. Continuous CO Monitoring System, Model A58II. Inlcrtech Corp.. Princeton. NJ.