Standards Improvement Project - Phase IV (SIP-IV) Notice of Proposed Rulemaking
Other documents for the same rulemaking (all, by stage)
References: 48 extracted, 0 linked to papers
Clapp, J., Fagerstrom, R., et al. (2011). Reduced Lung-Cancer Mortality with LowDose Computed Tomographic Screening. N. Engl. J. Med. 365(5): 395–409.
Detterbeck, F.C. (2012). Benefits and Harms of CT Screening for Lung Cancer: A Systematic Review. JAMA, 307(22): 2418– 2429.
Black, W.C. (2000). Overdiagnosis: An Underrecognized Cause of Confusion and Harm in Cancer Screening. Journal of the National Cancer Institute, Vol 92 (16): 1280
Follador, A., Cassetti, P., et al. (2007). LowDose Computed Tomography Screening for Lung Cancer and Pleural Mesothelioma in an Asbestos-Exposed Population: Baseline Results of a Prospective, Nonrandomized Feasibility Trial—An Alpe-Adria Thoracic Oncology Multidisciplinary Group Study (ATOM 002). The Oncologist, 12: 1215– 1224.
Woolner, L.B., Miller, W.E., Muhm, J.R., and Uhlenhopp, M.A. (1984). Early Lung Cancer Detection: Results of the Initial (Prevalence) Radiologic and Cytologic Screening in the Mayo Clinic study. Am. Rev. Resp. Dis., 130(4): 561. Abstract only.
Pairolero, P.C. and Bergstralh, E.J., (1991). Screening for Lung Cancer, A Critique of the Mayo Lung Project. Cancer, 67(supplement): 1155–1164).
Herman, C. (2006). What Makes a Screening Exam ‘‘Good’’? AMA Virtual Mentor, 8(1):34–7.
Hocking, W.G., Hu, P., Oken, M.M., Winslow, S.D., Kvale, P.A., Prorok, P.C., Ragard, L.R., et al. (2010). Lung Cancer Screening in the Randomized Prostate, Lung, Colorectal, and Ovarian (PLCO) cancer screening trial. J. Nat. Cancer Inst., 102(10): 722–731.
Hocking, W.G., Tammemagi, M.C., Commins, J., Oken, M.M., Kvale, P.A., Hu, P., . . . and Prorok, P.C. (2013). Diagnostic Evaluation Following a Positive Lung Screening Chest Radiograph in the
In, K.H., Kwon, Y.S., Oh, I.J., Kim, K.S., Jung, M.H., Lee, K.H., Kim, S.Y., Ryu, J.S., Lee, S.Y., Jeong, E.T., Lee, S.Y., . . . Kim, Y.C. (2009). Lung cancer patients who are asymptomatic at diagnosis show favorable prognosis: a Korean Lung Cancer Registry Study. Lung Cancer. 64(2): 232–7. Abstract only. [ILO] International Labour Organization (2011). Guidelines for the Use of the ILO International Classification of Radiographs of Pneumoconioses, Revised Edition 2011.
Geneva, Switzerland: ILO. Kubik, A., and Polak, J. (1986). Lung Cancer Detection Results of a Randomized Prospective Study in Czechoslovakia.
Brynes, G., Abramson, M., and Campbell, D. (2013). Screening for Lung Cancer. Cochrane Database Syst. Rev., The Cochrane Library, 6.
Marcus, P., Bergstralh, E.J., Zweig, M., Harris, A., Offord, K.P., and Fontana, R.S. (2006). Extended Lung Cancer Incidence Followup in the Mayo Lung Project and Overdiagnosis. J. Nat. Cancer Inst., 98(11).
Mazzone, P.J., Choi, H.K., and Ha, D. (2014) Lung Cancer. Cleveland Clinic Center for Continuing Education, The Disease Management Project, Chapter on Pulmonary Disease.
Moyer, V.A. (2014). Screening for Lung Cancer: U.S. Preventive Services Task Force Recommendation Statement. Annals Internal Med, 160 (5). [NCI] National Cancer Institute (Last modified 2/2014). Screening for Lung Cancer With Chest X-Ray and/or Sputum Cytology. Retrieved from: http:// www.cancer.gov/cancertopics/pdq/ screening/lung/HealthProfessional on September 16, 2014.
Oken, M., Hocking, W., Kvale, P., Andriole, G., Buys, S., Church, T., et al. (2011). Screening by Chest Radiograph and Lung Cancer Mortality: The Prostate, Lung,
Colorectal, and Ovarian (PLCO) Randomized Trial. JAMA, 306(17): 1865– 1873. PubMed Health, Retrieved 9/16/2014 from: http://www.ncbi.nlm.nih.gov/ E:\FR\FM\04OCP2.SGM 04OCP2 Federal Register / Vol. 81, No. 192 / Tuesday, October 4, 2016 / Proposed Rules pubmedhealth/PMH0004529/on September 16, 2014.
Engelshoven, J.M. (1999). Miss rate of lung cáncer on the chest radiograph in clinical practice. Chest. 115(3):720–4.
Toyoda, Y., Nakayama, T., Kusunoki, Y., Iso, H., and Suzuki, T. (2008). Brit. J. Cancer, 98: 1602–1607. Screening for Lung Cancer, Topic Page (2013). U.S. Preventive Services Task
CFR 1910.1043(h). These provisions require initial and periodic medicalsurveillance examinations that include VerDate Sep<11>2014 19:27 Oct 03, 2016 Jkt 241001 administration of a medical questionnaire to determine if workers are experiencing symptoms (§§ 1910.1043(h)(2)(ii) and (h)(3)(i)). Medical surveillance requirements also include pulmonary function testing (i.e., spirometry testing) to objectively measure lung function and to assess changes in lung function (§ 1910.1043(h)(2)(iii)). The preamble for the final Cotton Dust standard noted the poor accuracy and high variability of pulmonary function tests in the past, resulting from lack of uniform specifications for equipment calibration checks, test procedures, and personnel training (43
ATS (American Thoracic Society). Medical Section of the American Lung Association(1979). ATS Statement— Snowbird Workshop on Standardization of Spirometry. American Review of Respiratory Disease, 119, 831–838.
ATS (American Thoracic Society). Medical Section of the American Lung Association(1987). Standardization of Spirometry—1987 Update. Am Rev Respir
Dis, 136, 1285–1298. ATS (American Thoracic Society). Medical Section of the American Lung Association(1994). Standardization of Spirometry—1994 Update. Am Resp Crit Care Med, 152, 1107–1136.
CDC/NIOSH (Centers for Disease Control/ National Institute for Occupational Safety and Health)(1974). Criteria for a Recommended Standard: Occupational Exposure to Cotton Dust. Chapter XII: Tables and Figures. http://www.cdc.gov/ niosh/pdfs/75-118f.pdf.
CDC/NIOSH (Centers for Disease Control/ National Institute for Occupational Safety and Health)(2003). Spirometry training guide. December 1, 2003. http:// www.cdc.gov/niosh/docs/2004-154c/pdfs/ 2004-154c.pdf.
CDC/NIOSH (Centers for Disease Control/ National Institute for Occupational Safety and Health)(2010). Spirometry reference value calculator. http://www.cdc.gov/ niosh/topics/spirometry/ RefCalculator.html.
B. (1999). Spirometric reference values from a sample of the general US population. Am J Respir Crit Care Med., 159, 179–87.
Hankinson, J. H., Kawut, S. M. and Shahar, E. (2010). Performance of American Thoracic Society-recommended spirometry reference values in a multiethnic sample of adults. Chest, 137, 138–145. VerDate Sep<11>2014 19:27 Oct 03, 2016 Jkt 241001
Knudson, R. J., Slatin, R. C., Lebowitz, M. D. and Burrows, B. (1976). The maximal expiratory flow-volume curve. Normal standards, variability, and effects of age. Am Rev Respir Dis, 113, 587–600.
Wanger, J. (2005). American Thoracic Society/European Respiratory Society (ATS/ERS) Task Force: Standardisation of Spirometry. Eur Respir J, 26, 319–33, http://www.thoracic.org/statements/ resources/pfet/PFT2.pdf.
OSHA (Occupational Safety and Health Administration) (2013). Spirometry testing in occupational health programs. Best practices for healthcare professionals. US Department of Labor. http://www.osha.gov/ Publications/OSHA3637.pdf.
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R. . . . Wanger, J. (2005). ATS/ERS standardisation of lung function testing. Interpretative strategies for lung function tests. Eur Respir J., 26, 948–968.
Weissman, D.N. (2014). American Thoracic Society Committee on Spirometry in the Occupational Setting. Official American Thoracic Society technical standards: Spirometry in the occupational setting. Am J Respir Crit Care Med., 189(8), 983–93.
C. (2011). American College of Occupational and Environmental Medicine (ACOEM) Occupational and Environmental Lung Disorders Committee. Spirometry in the occupational health setting—2011 update. J Occup Environ Med, 53, 569–584. http://www.acoem.org/uploadedFiles/ Public_Affairs/Policies_And_Position_ Statements/
ACOEM%20Spirometry%20Statement.pdf. 4. Subpart F of 1915—General Working
Employment, § 1915.88(j)(1) and (j)(2), specify that employers must, to the extent reasonably practicable, clean and maintain workplaces in a manner that prevents vermin infestation. When employers detect vermin, they must implement and maintain an effective vermin-control program. Paragraph (b)(33) of § 1915.80 defines the term ‘‘vermin’’ as ‘‘insects, birds, and other animals, such as rodents and feral cats, that may create safety and health hazards for employees.’’ OSHA included this definition in the proposal for 29 CFR part 1915, subpart F, General Working Conditions in Shipyard
PO 00000 Frm 00013 Fmt 4701 Sfmt 4702 68515 requested comment on the proposed vermin-control provisions, as well as examples of vermin that are present and the types of controls employers use to prevent the harborage of vermin in shipyard worksites. Id. at 72484. The Agency cited the hazards associated with exposure to insects, birds, and rodents in the preamble discussion, but did not mention any hazards associated with feral cats. Id. The Agency received two comments on these provisions. One commenter stated that vermin did not pose a serious hazard to workers and that OSHA should remove these provisions from the rulemaking (Ex. 197.1, Docket No. OSHA–S049–2006– 0675). The other commenter explained that the number and types of vermin are greater than OSHA indicated in the proposed discussion, and that ‘‘[t]o ‘implement and maintain an effective control program’ as required in this section would probably be very expensive, near impossible or even illegal’’ (Ex. 121.1, Docket No. OSHA– S049–2006–0675). Based on the general industry sanitation standard that applied to shipyard employment prior
BLS, 2013a. Bureau of Labor Statistics Occupational Employment Survey. May 2013. BLS Occupational Code: Construction Laborer 47–2061. Found at: http://www.bls.gov/oes/current/ oes472061.htm.
BLS, 2013b. Employer Cost for Employee Compensation, December 2013. Economic News Release March 12th 2014. Found at: http://www.bls.gov/ news.release/ecec.t06.htm.
Census, 2012. U.S. Census Bureau, ‘‘Characteristics of New Housing 2012.’’ Found at: http://www.census.gov/ construction/chars/highlights.html.
Census, 2014. U.S. Census Bureau, Construction Spending Survey data, accessed from http://www.census.gov/ econ/currentdata. Dodge Data and Analytics, data run, 2 Penn Plaza New York, New York 10121.
ERG, 2015. Eastern Research Group, ‘‘Supporting Information for Standard Improvement Project 4,’’.September, 2015.
FCC, 2014. Federal Communications Commission, ‘‘911 Wireless Services Guide,’’ December 2014.
NENA, 2001. RCN Commission and the National Emergency Number Association VerDate Sep<11>2014 19:27 Oct 03, 2016 Jkt 241001 Reduced radiation, fewer false positives. Brings OSHA standards up to current technology and medical practices. Better protect employees, reduce cases of decompression illness, bring
Effectiveness, Accessibility and Future of America’s 9–1–1 Service,’’ September 2001. Found at: https://c.ymcdn.com/ sites/www.nena.org/resource/collection/ 7F122EC0-BC5A-46DD-9A65B39A035E87D5/NENA_Report_to_the_ Nation_1.pdf.
OSHA, 1989. U.S. Department of Labor, Occupational Safety and Health
August, 1989. Found at: http:// www.regulations.gov/ #!documentDetail;D=OSHA-S012A2006-0642-0266. V. Legal Considerations The purpose of the Occupational Safety and Health Act of 1970 (OSH Act; 29 U.S.C. 651 et al.) is ‘‘to assure so far as possible every working man and woman in the Nation safe and healthful working conditions and to preserve our human resources . . .’’ (29 U.S.C. 651(b).) To achieve this goal, Congress authorized the Secretary of Labor to promulgate and enforce occupational safety and health standards; authorized summary adoption of existing national consensus and established Federal standards within two years of the effective date of the OSH Act (29 U.S.C. 655(a)); authorizing promulgation of standards pursuant to notice and comment (29 U.S.C. 655(b)); and required employers to comply with
PO 00000 Frm 00035 Fmt 4701 Sfmt 4702 standard must be supported by substantial evidence, and be better able to effectuate the OSH Act’s purposes than any national consensus standard it supersedes. (See 58 FR 16612–16616, March 30, 1993.) A standard is technologically feasible if the protective measures it requires already exist, can be brought into existence with available technology, or can be created with technology that can reasonably be expected to be developed. (See American Textile Mfrs. Institute v.