Air Quality Criteria Document for Oxides of Nitrogen, EPA-600/8-91/049aF-cF, August 1993. (NTIS} [A-95-27-II-A-1]
Other documents for the same rulemaking
References: 3,185 extracted, 0 linked to papers
Warren, MI 1.24/tg/m3 3.70 /ig/m3 Dasch et al. (1989)
Warren, MI 1.14/ig/m3 4.20 /tg/m3 Dasch and Cadle (1990)
Boston, MA 1.42 ppbf 0.59 ppbg 6.06 nmol/m 3f 11.76 nmol/m3g Brauer et al. (1991) H N 0 3 = Nitric acid. N0 3 " = Nitrate ion.
Protection Agency, 1991a). When sites in MSAs with 250,000 to 500,000 population and 500,000 to 1 miUion people were compared to sites with more than 1 miUion, there was a regular pattern that persisted over the fuU 10 years. The sites with populations over 1 miUion were 0.01 ppm higher than those with 250,000 to 500,000, with the mid-population sites in between, as seen in Figure 7-2. 7.2.3.3 Exposure Patterns Observed for Ambient Nitrogen Dioxide and Nitric Oxide Concentrations—Urban The N0 2 hourly average concentrations tend to be less than 0.001 ppm in remote areas, 0.001 to 0.020 ppm in mral areas, 0.02 to 0.20 ppm in moderately poUuted areas, and 0.2 to 0.5 ppm in heavUy poUuted areas (Legge et al., 1990). Information in Tables 7-2 and 7-3 P.11 0.06
ALL SITES (148). 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 Figure 7-1. National trend in the composite annual average mtrogen dioxide concentrations at both National Air Monitoring Station sites and aU sites with 95% confidence intervals, 1980 to 1989. Source: U.S.
Environmental Protection Agency (1991a). iUustrate this observation. A high-elevation site at Mt. MitcheU, NC, provides an example of low N0 2 concentrations in mral areas. In 1987, the maximum hourly average concentration of N0 2 was below 0.007 ppm; almost 99% of the hourly average N0 2 values were below 0.005 ppm (Lefohn, 1989). In addition, electric generating stations do provide a source of N0 2 in both mral and uiban areas. A summary of the hourly average N0 2 concentrations that were measured near selected electric generating stations is provided in Table 7-5. Although the hourly average N0 2 concentrations measured are a fiinction of the emitter's source strength, as weU as other considerations such as meteorological and geographic conditions, the infrequent occurrence of hourly average concentrations of N0 2 ^0.10 ppm is evident. In general, for the sites Usted in the table, only 5% of the hourly average concentrations were ^0.05 ppm. For mral locations near electric generating plants, the infrequent occurrence of hourly average concentrations of N0 2 ^0.05 ppm has been reported previously in the Uterature (Lefohn and Tingey, 1984; Lefohn et al., 1987). P.12 0.03 —H—- 0.025 """"O---. | 0.015 0.01
Environmental Protection Agency (1991a). Table 7-6 Usts the highest annual average for 103 MSAs reporting at least one N0 2 monitoring station with vaUd data in 1988, 1989, and 1990 (U.S. Environmental Protection
Agency, 1990, 1991a, 1991b). The MSAs are Usted in alphabetical order. Peak annual averages in these MSAs range from 0.007 to 0.061 ppm. Figure 7-3 shows that the coUective mode for the peak annual average in the 1988 to 1989 period was approximately 0.02 ppm. Table 7-7 Usts the highest hourly N0 2 average concentrations by MSAs reported across the United States. The highest hourly N0 2 average concentrations ranged from 0.040 to 0.540 ppm. Throughout the last 10 years, Los Angeles, CA, was the only urban area to record violations of the annual N0 2 NAAQS of 0.053 ppm (U.S. Environmental
Protection Agency, 1991b). For the 45 sites monitoring N0 2 during the period 1980 to 1989 and experiencing at least 1 year's data capture 5:75%, nine sites exceeded the NAAQS at least 1 year during the momtoring period. As expected, this area also experiences the 7-10
FROM 1985 AND 1991 SURVEYS Percent Frequency for: Type of Range 1991 Survey 1985 Survey
Gas, not sure Electric 61.0 60.8 Gas and electric None Source: Koontz et al. (1992).
FOR COOKING, BY INCOME Characteristic Days for Breakfast Days for Lunch Days for Dinner Less than $12,500 $12,500 to $22,499 $22,500 to $34,999 $35,000 to $49,999 $50,000 or more Income of Respondent: Source: Koontz et al. (1992). reported range/oven cooking frequency in 1985 and 1991 related to microwave use is shown in Table 7-19. Use of gas ranges without pUot Ughts and changes in cooking practices, such as increased use of microwave ranges, could result in lower N0 2 levels in such homes. The Koontz et al. (1992) survey examines the change from 1985 to 1991 but provides no data for earUer use of cooking stoves with and without pUot Ughts or the use of microwave ranges. The trend in this data suggests that, in the period before 1985, homes with pUot Ughts would be more common than after 1985, and other cooking choices, such as microwave, were used less frequently. Thus, in epidemiology studies (see Chapter 14) 7-58 P.61
AU studies investigating N0 2 concentrations in homes with gas appUances have found a concentration gradient between rooms (Table 7-16), with the kitchen being highest and the bedroom being lowest. This gradient is highUghted in Figure 7-23. Figure 7-23 also highhghts the seasonal differences in indoor N0 2 levels in homes with gas appUances. In this study (Spengler et al., 1983), season and location in the house were found to be statisticaUy significant predictors of N0 2 levels in homes with gas appUances. The withinhome spatial variations are related to such variables as air exchange rates among rooms, air mixing within a room, volume of a house, location of the air sampler, and the frequency and length of gas appUance use. 7.3.3.3 Short-Term Indoor Concentrations The majority of data on indoor N0 2 levels associated with gas stove use is from integrated monitors, sampling over periods of days. The recorded N0 2 values are averaged over several on/off periods of gas stove use, and as such, do not directly measure short-term indoor N0 2 levels (levels on a time frame of minutes or hours) in homes, which occur during source use. The short-term concentrations are associated with length of source use, number of sources (e.g., number of gas burners used), and location at which the 7-60 P.63
NQ> (ng/m3) Figure 7-22. Verticle distribution of average nitrogen dioxide concentrations (48-h sampling periods) measured in nine New York City apartments. Plotted from data by Goldstein et al. (1985). measurement is taken relative to the source (e.g., immediately over the source or several feet away). Few studies have measured short-term N0 2 levels in residences with gas appUances. In a study of the incidence of respiratory Ulness in households using gas and electricity for cooking, KeUer et al. (1979) used continuous chemiluminescence monitoring over 3-day periods in 46 homes in the Columbus, OH, area to measure continuous variations in indoor N0 2 and NO levels in relation to cooking times. The study found that variations in instantaneous peak N0 2 levels (highest concentrations measured with a continuous monitor) in gas-cooking households reached as high as eight times the 24-h average values. In several households, instantaneous peak N0 2 concentrations exceeded 1,900 /xg/m (1 ppm). The study did not report the location of the sampler relative to the source, the number of sources, length of source use, or sample averaging time. As part of a study of respiratory disease 7-61 P.64
AIRS, Aerometric Information Retrieval System [database]. (1991) [Data on N O J . Research Triangle Park, NC: U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Disc; IBM 3090.
AIRS, Aerometric Infonnation Retrieval System [database]. (1992) [Data on NOJ. Research Triangle Park, NC: U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards.
Allegrini, I.; De Santis, F. (1989) Measurement of atmospheric pollutants relevant to dry acid deposition. Crit. Rev. Anal. Chem. 21: 237-255.
V. (1987) Indoor-outdoor nitrogen dioxide concentration ratios for homes with gas and electric cooking. In: Seifert, B.; Esdorn, H.; Fischer, M.; Rueden, H.; Wegner, J., eds. Indoor air '87: proceedings of the 4th international conference on indoor air quality and climate, v. 1, volatile organic compounds, combustion gases, particles and fibres, microbiological agents; August; Berlin, Federal Republic of Germany. Berlin, Federal Republic of Germany: Institute for Water, Soil and Air Hygiene; pp. 383-389.
R. (1988) User's guide to the NEM/SAI exposure model. San Rafael, CA: Systems Applications, Inc.; SYSAPP-88/051.
L. (1987) Residential indoor air quality characterization study of nitrogen dioxide. Phase II final report: the wall and floor furnace inspection study. Los Angeles, CA: Southern California Gas Company.
H. (1991) An update of the natural gas industry's research related to indoor air quality. Presented at: American Gas Association 1991 distribution/transmission conference; April-May; Nashville, TN.
D. (1989) Simulation of indoor nitrogen dioxide concentrations. In: Harper, J. P., ed. Combustion processes and the quality of the indoor environment: transactions of an international specialty conference; September 1988; Niagara Falls, NY. Pittsburgh, PA: Air & Waste Management Association; pp. 151-172. (A&WMA transactions series: TR-15).
C. (1984) NO x measurements in clean continental air and analysis of the contributing meteorology. J. Geophys. Res. [Atmos.] 89: 9623-9631.
I. (1987a) Modeling and monitoring of CO, NO and N 0 2 in a modern townhouse. Atmos. Environ. 21: 299-311.
I. (1987b) Determination of NO2 loss rates from concentration measurements in an occupied urban residence. In: Seifert, B.; Esdorn, H.; Fischer, M.;
D. (1991) Indoor and outdoor concentrations of inorganic acidic aerosols and gases. J. Air Waste Manage. Assoc. 41: 171-181. 7-95 P.98
D. (1990) Predicting indoor NO2 concentrations as a function of home characteristics and ambient N0 2 levels. In: Indoor air '90: precedings of the 5th international conference on indoor air quality and climate, volume 2, characteristics of indoor air; July-August; Toronto, ON, Canada. Ottawa, ON, Canada: International Conference on Indoor Air Quality and Climate, Inc.; pp. 519-524.
H. (1985) Seasonal variations in nitric acid, nitrate, strong aerosol acidity, and ammonia in an urban area. Atmos. Environ. 19: 181-188.
A. (1988) Atmospheric summertime concentrations and estimated dry deposition rates ofnitrogen and sulfur species at a Smoky Mountain site in North Carolina. Presented at: 81st annual meeting of the Air Pollution Control Association; June; Dallas, TX. Pittsburgh, PA: Air Pollution Control Association; paper no. 88-119.3.
A. (1982) Nitric acid and ammonia in urban and rural locations. Atmos. Environ. 16: 2501-2506.
Clausing, P.; Mak, J. K.; Spengler, J. D.; Letz, R. (1984) Personal N0 2 exposures of high school students. In: Berglund, B.; Lindvall, T.; Sundell, J., eds. Indoor air: proceedings ofthe 3rd international conference on indoor air quality and climate, v. 4, chemical characterization and personal exposure; August; Stockholm, Sweden. Stockholm, Sweden: Swedish Council for Building Research; pp. 135-139. Available from: NTIS, Springfield, VA; PB85-104214.
D. (1992) Nitrogen dioxide exposure studies: volume V, personal exposure to nitrogen dioxide in the Los Angeles basin: a microenvironmental approach. Chicago, IL: Gas Research Institute; report no. GRI-92/0427.
H. (1990) The removal of nitric acid to atmospheric particles during a wintertime field study. Atmos. Environ. Part A 24: 2557-2562.
A. (1989) Comparison of annular denuders and filter packs for atmospheric sampling. Atmos. Environ. 23: 2775-2782.
E. (1976) Formation and transport of oxidants along Gulf Coast and in northern U.S. Research Triangle Park, NC: U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards; EPA report no. EPA-450/3-76-033. Available from: NHS, Springfield, VA;
D. (1989) Development of models for predicting the distribution of indoor nitrogen dioxide concentrations. JAPCA 39: 1169-1177.
Federal Register. (1979) Air programs; ambient air quality momtoring, data reporting, and surveillance provisions. F. R. (May 10) 44: 27558-27604.
A. (1987) A ground-based intercomparison of NO, NOx, and NOy measurement techniques. J. Geophys. Res. [Atmos.] 92: 14710-14722. 7-96 P.99
Ferris, B. G., Jr.; Speizer, F. E.; spengler, J. D.; Dockery, D.; Bishop, Y. M. M.; Wolfson, M.; Humble, C. (1979) Effects of sulfur oxides and respirable particles on human health. Methodology and demography of populations in study. Am. Rev. Respir. Dis. 120: 767-779.
P. (1987) Radon mitigation through residential pressurization control strategy. In: Seifert, B.; Esdom, H.; Fischer, M.; Rueden, H.; Wegner, J., eds. Indoor air '87: proceedings of the 4th international conference on indoor air quality and climate, v. 2, environmental tobacco smoke, multicomponent studies, radon, sick buildings, odours and irritants, hypeneactivities and allergies; August; Berlin, Federal Republic of Germany. Berlin, Federal Republic of Germany: Institute for Water, Soil and Air Hygiene; pp. 300-304.
Fugas, M. (1976) Assessment of total exposure to an air pollutant. In: International conference on environmental sensing and assessment, v. 2; September; Las Vegas, NV. New York, NY: Institute of Electrical and Electronic Engineers; paper no. 38-5.
H. (1979) The relation between respiratory illness in primary schoolchildren and the use of gas for cooking. II. Factors affecting nitrogen dioxide levels in the home. Int. J. Epidemiol. 8: 339-345.
R. (1985) Monitoring personal exposure to nitrogen dioxide. Presented at: 78th annual meeting of the Air Pollution Control Association; June; Detroit, MI. Pittsburgh, PA: Air Pollution Control Association; paper no. 85-85.7.
L. (1982) Effect of cigarette smoking on residential N 0 2 levels. Environ. Int. 8: 167-175.
C. (1982) Calculating infiltration: implications for a construction quality standard. In: Proceedings of the ASHRAE-EOE conference on the thermal performance of the exterior envelope of buildings II; December; Las Vegas, NV. New York, NY: American Society of Heating, Refrigerating and Air-Conditioning Engineers; pp. 422-452.
E. (1979) Air leakage characteristics and weatherization techniques for low-income housing. In: Proceedings of the ASHRAE-DOE conference on the thermal performance of the exterior envelope of buildings; December; Orlando, FL. New York, NY: American Society of Heating, Refrigerating and Air-Conditioning Engineers; pp. 178-194.
Hanson, P. J.; Taylor, G. E., Jr.; Vose, J. (1992) Experimental laboratory measurements of reactive N gas deposition to forest landscape surfaces: biological and environmental controls. In: Johnson, D. W.;
Harlos, D. P.; Spengler, J. D.; Billick, I. (1987) Continuous nitrogen dioxide momtoring during cooking and commuting: personal and stationary exposures. In: Seifert, B.; Esdom, H.; Fischer, M.; Rueden, H.;
R. (1989) Estimating the effect of being indoors on total personal exposure to outdoor air pollution.
C. (1987) Estimation of nitrogen dioxide concentrations in homes equipped with unvented gas space heaters. In: Seifert, B.;