USEPA (2015) Case Studies on Implementing Low-Cost Modifications to Improve Nutrient Reduction at Wastewater Treatment Plants. Report.
Other documents for the same rulemaking (all, by stage)
References: 54 extracted, 0 linked to papers
Young T., J. Stullken, D. Abbott, and K. Benner. 2011. Ditch the nutrients. Water Environment and Technology. October 2011. Case Studies on Implementing Low-Cost Modifications to Improve Nutrient Reduction at Wastewater Treatment Plants: DRAFT Version 1.0 August 2015 Appendix A List of Nutrient Reduction Resources Case Studies on Implementing Low-Cost Modifications to Improve Nutrient Reduction at Wastewater Treatment Plants: DRAFT Version 1.0 August 2015 U.S. Environmental Protection Agency (EPA)
WERF main website: http://www.werf.org. Nutrient Research at a Glance: http://www.werf.org/c/KnowledgeAreas/NutrientRemoval/Nutrients_Research_at_a_Glan ce.aspx. Nutrient Management Compendium Documents: http://www.werf.org/c/KnowledgeAreas/NutrientRemoval/Nutrients_Compendium.aspx. Other Resources Water Environment Federation (WEF) Nutrient Knowledge Center: http://www.wef.org/AWK/pages_cs.aspx?id=1067. Case Studies on Implementing Low-Cost Modifications to Improve Nutrient Reduction at Wastewater Treatment Plants: DRAFT Version 1.0 August 2015 Appendix B Case Study Summary Documents Case Studies on Implementing Low-Cost Modifications to Improve Nutrient Reduction at Wastewater Treatment Plants: DRAFT Version 1.0 August 2015
SYSTEM SUMMARY Official Name: Bay Point Wastewater Treatment Plant (WWTP) Location: 3116 Overseas Highway, MM15, Key West (Bay Point), FL 33040. Monroe County. Florida Keys (latitude: 24° 37’ 39” N; longitude: 81° 35’ 40” W) Permitted design flow: 0.054 MGD Service area: The Bay Point system serves approximately 429 EDUs1 within the service area, which includes the Bay Point subdivision and Blue Water RV park in the Saddlebunch Keys System type: Activated sludge/Modified Ludzack-Ettinger (MLE) and upflow sludge blanket filtration (USBF) to Class V injection wells Initial year of operation: 2005 Upgrade type: Improved process controls and minor mechanical modifications Upgrade year of operation: 2008 Permitted effluent nitrogen limit: 12.5 mg/l, monthly average TN; 10 mg/l, annual average TN Pre- and post-upgrade effluent nitrogen performance: 6.63 mg/l average, pre-upgrade; 3.99 mg/l average, post-upgrade Permitted effluent phosphorus limit: 1.25 mg/l, monthly average TP; 1.0 mg/l, annual average TP Pre- and post-upgrade phosphorus performance: 0.47 mg/l average, pre-upgrade; 0.42 mg/l average, post-upgrade
EDU = equivalent dwelling unit, which is the approximate number of residences served by the facility. Case Studies on Implementing Low-Cost Modifications to Improve Nutrient Reduction at Wastewater Treatment Plants: DRAFT Version 1.0 Pre-upgrade Post-upgrade Effluent Total Nitrogen Average Standard Concentration Deviation 6.63 4.98 3.99 2.50 Effluent Total Phosphorus Average Standard Concentration Deviation 0.47 4.96 0.42 0.49 August 2015