St Clair et al. (2016) Long-Term Behavior of Simulated Partial Lead Service Line Replacements, Journal Article
Other documents for the same rulemaking (all, by stage)
References: 49 extracted, 0 linked to papers
APHA. (1998). Standard Methods for the Examination of Water and Wastewater, APHA, AWWA, WEF.
Arnold, R.B., and Edwards, M. (2012). Potential reversal and the effects of flow pattern on galvanic corrosion of lead. Environ. Sci. Technol. 46, 10941.
Boyd, G.R., Reiber, S.H., McFadden, M., and Korshin, G. (2012). Effect of changing water quality on galvanic coupling. J. AWWA. 104, E136.
Breach, R.A., Crymble, S., and Porter, M.J. (1991). A Systematic Approach to Minimizing Lead Levels at Cosumers’ Taps. Paper presented at the American Water Works Association Annual Conference and Exposition, Philadephia: PA.
Britton, A., and Richards, W.N. (1981). Factors influencing plumbosolvency in Scotland. J. Inst. Water Eng. Sci. 35, 349.
Brown, M.J., and Margolis, S. (2012). Lead in Drinking Water and Human Blood Lead Levels in the United States. Morbidity and mortality weekly report. Surveillance summaries. Washington: DC, p. 61, 1.
Cartier, C., Arnold, R.B., Jr., Triantafyllidou, S., Prévost, M., and Edwards, M. (2012a). Effect of Flow Rate and Lead/ Copper Pipe Sequence on Lead Release from Service Lines. Water Res. 46, 4142.
Cartier, C., Doré, E., Laroche, L., Nour, S., Edwards, M., and Prévost, M. (2013). Impact of Treatment on Pb Release from Full and Partially Replaced Harvested Lead Service Lines (LSLs). Water Res. 47, 661.
Cartier, C., Nour, S., Richer, B., Deshommes, E., and Prévost, M. (2012b). Impact of water treatment on the contribution of faucets to dissolved and particulate lead release at the tap. Water Res. 46, 5205.
Clark, B., Cartier, C., St. Clair, J., Triantafyllidou, S., Prévost, M., and Edwards, M. (2013). Effects of commercial connectors on galvanic corrosion between Pb/Cu pipes. J. Am. Water Works Assoc. Accepted; pp. E576–E586; http://dx.doi. org/10.5942/jawwa.2013.105.0113
Clark, B., Hernandex, A.L., and Edwards, M. (2011). Deposition Corrosion of Water Distribution System Materials. Paper presented at the Water Quality Technology Conference,
Phoenix, AZ. Clark, B., Masters, S., and Edwards, M. (2012). 3-D Lead Profiling Detects Particulate Lead-in-Water Risks as a Function of Flow Rate. Paper presented at the Water Quality Technology Conference, Toronto, ON.
Clark, B., St. Clair, J., and Edwards, M. (2015) Copper deposition corrosion elevates lead release to potable water. J. Am. Water Works Assoc. 107, E627–E637.
Copper Development Association. (1999). Copper Tube in Domestic Water Services Publication 33. Available at: http://www.copper .co.za/downloads/library/33-Copper-Tube-in-Domestic-WaterServices.pdf (accessed November 25, 2015). Del Toral, M.A., Porter, A. and Schock, M.R. (2013). Detection and evaluation of elevated lead release from service lines: a field study. Environ. Sci. Technol. 47, 9300.
Deshommes, E., Laroche, L., Nour, S., Cartier, C., and Prévost, M. (2010). Source and occurrence of particulate lead in tap water. Water Res. 44, 3734. Doré, E., Cartier, C., Edwards, M., DeSantis, M., Schock, M.,
Laroche, L., Nour, S., and Prévost, M. (2012). Impact of Treatment on Scale Formation and Lead Release from aged LSLs. Paper presented at the American Water Works Association, WQTC, Toronto, CA.
Edwards, M. 2012. Discussion: Effect of Changing Water Quality on Galvanic Coupling. J. Am. Water Works Assoc. 104, 65.
Edwards, M. 2014. Fetal death and reduced birth rates associated with exposure to lead-contaminated drinking water. Env. Sci. Tech. 48, 739.
Gehring, Jr., G., Lindemuth, D., and Young, W. (2003). Break Reduction/Life Extension Program for Cast and Ductile Iron Water Mains. New Pipeline Technologies, Security, and Safety: pp. 321–331. doi: 10.1061/40690(2003)30
Giammar, D.E., Welter, G.J., and Cantor, A. (2012). Review of previous water research foundation projects on galvanic corrosion. Water Res. Found. Retrieved from www.waterrf.org/ ProjectsReports/ProjectPapers/Lists/PublicProjectPapers/ Attachments/3/4349_LiteratureReview.pdf.
Giani, R. (2008). Possible Influence of Galvanized Plumbing in Elevated Lead Levels. Paper presented at the American Water Works Association Annual Conference and Exposition,
Atlanta, GA. Giani, R., Edwards, M., Chung, C., and Wujek, J. (2004). Use of Lead Profiles to Determine Source of Action Level Exceedances from Residential Homes in Washington. Paper presented at the DC Proceedings AWWA Water Quality Technology Conference Sunday Workshop. San Antonio, TX.
Hulsmann, A.D. (1990). Particulate lead in water supplies. Water Environ. J. 4, 19.
HDR Engineering, Inc. (2009). An Analysis of the Correlation Between Lead Released from Galvanized Iron Piping and the Contents of Lead in Drinking Water. Bellevue, WA: HDR
Engineering, Inc. Hu, J., Gan, F., Triantafyllidou, S., Nguyen, C.K., and Edwards, M. (2012). Copper-induced metal release from lead pipe into drinking water. Corrosion. 68, 1037.
Lytle, D.A., Schock, M.R., Dues, N.R., and Clark, P.J. (1993). Investigating the preferential dissolution of lead from solder particulates. J. Am. Water Resources Assoc. 85, 104.
McNeill, L.S., and Edwards, M. (2004). Importance of Pb and Cu particulate species for corrosion control. J. Environ. Eng. 130, 136.
Masters, S., Parks, J., Atassi, A., and Edwards, M.A. (2015). Distribution system water age can create premise plumbing corrosion hotspots. Environ. Monit. Assess. 187, 1.
Suffoletta, V. (2011). Full versus partial lead service line replacement and lead release in a well buffered groundwater. Paper presented at the American Water Works Association, Water Quality Technology Conference, Phoenix, AZ.
NDWAC (National Drinking Water Advisory Council) (2011). Letter to EPA Administrator on Revised Lead and Copper Rule. Retrieved November 25, 2015, from http://water.epa.gov/drink/ ndwac/upload/ndwaclettertoepadec2011.pdf
Rajani, B., and Kleiner, Y. (2003). Protecting ductile-iron water mains: what protection method works best for what soil condition? J. Am. Water Works Assoc. 95, 110.
Reiber, S., and Dufresne, L. (2006). Effects of External Currents and Dissimilar metal contact on Corrosion of Lead from Lead Service Lines. Philadelphia: Final Report to USEPA region III.
Retraction Watch. (2015). Expression of concern opens floodgates of controversy over lead in water supply. Available at: http:// retractionwatch.com/2015/04/15/expression-of-concern-opensfloodgates-of-controversy-over-lead-in-water-supply/ (accessed June 29, 2015).
Schock, M.R., Cantor, A.F., Triantafyllidou, S., Desantis, M.K., and Scheckel, K.G. (2014). Importance of pipe deposits to Lead and Copper Rule compliance. J. AWWA. 106, 7. St. Clair, J., Stamopoulos, C., and Edwards, M. (2012). Technical note: increased distance between galvanic lead:copper pipe connections decreases lead release. Corrosion. 68, 779.
DeMarco, J. (2008). Water quality effects of partial lead line replacement. Paper presented at the American Water Works Association Annual Conference and Exposition, San
Antonio, TX. Swertfeger, J., Metz, D.H., and Webb, D. (2011). Benefits of a utility lead research program. Paper presented at the American Water Works Association Annual Conference and Exposition, Washington, DC.
Triantafyllidou, S., and Edwards, M. (2010). Contribution of galvanic corrosion to lead in water after partial lead service line replacements. Water Res. Found. Report No. 4088.
Triantafyllidou, S., and Edwards, M. (2011). Galvanic corrosion after simulated small-scale partial lead service line replacements. J. Am. Water Works Assoc. 103, 85.
Triantafyllidou, S., Gallagher, D., and Edwards, M. (2014). Assessing risk with increasingly stringent public health goals: the case of water lead and blood lead in children. J. Water Health. 12, 57.
Triantafyllidou, S., Parks, J., and Edwards, M. (2007). Lead particles in potable water. J. Am. Water Works Assoc. 99, 107.
US EPA. (1991). Maximum Contaminant Level Goals and National Primary Drinking Water Regulations for Lead and Copper. (Federal Register 56, 26460).
US EPA. (2011). Science Advisory Board Evaluation of the Effectiveness of Partial Lead Service Line Replacements, EPASAB-11-015 Retrieved 2012/02/15, from http://yosemite.epa .gov/sab/SABPRODUCT.nsf/RSSRecentHappeningsBOARD/ 964CCDB94F4E6216852579190072606F/$File/EPA-SAB11-015-unsigned.pdf
US EPA. (2012). Long-Term Revision for the Lead and Copper Rule (LCR), Retrieved 2013/06/11, from www.epa.gov/rfa/ lead-copper.html van den Hoven, T., and Slaats, N. (2005). Lead Monitoring, in Analytical Methods for Drinking Water: Advances in Sampling and Analysis (eds P. Quevauviller and K. C. Thompson),
Wang, Y., Jing, H., Mehta, V., Welter, G.J., and Giammar, D.E. (2013). Effect of connection methods on lead release from galvanic corrosion. J. Am. Water Works Assoc. 105, 337.
Wang, Y., Jing, H., Mehta, V., Welter, G.J., and Giammar, D.E. (2012). Impact of galvanic corrosion on lead release from aged lead service lines. Water Res. 46, 5049.
Welter, G., Giammar, D., Wang, Y., and Cantor, A. (2013). Galvanic corrosion following partial lead service line replacement. Water Res. Found. Report No. 4349.
Xie, Y., and Giammar, D.E. (2011). Effects of flow and water chemistry on lead release rates from pipe scales. Water Res. 45, 6525.
Zhou, E., Payne, S.J.O., Hofmann, R., and Andrews, R.C. (2015). Factors affecting lead release in sodium silicatetreated partial lead service line replacements. J. Environ. Sci. Health A Tox. Hazard. Susbst. Environ. Eng. 50, 922.
DOI: 10.1089/ees.2015.0337