NIOSH LODD Report 2011-02
Other documents for the same rulemaking
References: 34 extracted, 0 linked to papers
1. Brunacini A, [2002]. Fire Command: The Essentials of Local IMS. Quincy MA: National Fire Protection Association.
2. NFPA [2008]. NFPA 1561: Standard on emergency services incident management system. 2008 ed. Quincy, MA: National Fire Protection Association. 3. Dunn V [2000]. Command and control of fires and emergencies. Saddle Brook, NJ: Fire Engineering Book and Videos.
4. NFPA [2007]. NFPA 1500: Standard on Fire Department Occupational Safety and Health Program. Quincy, MA: National Fire Protection Association. Page 28 Report # F2011-02 Volunteer Fire Fighter Caught in a Rapid Fire Event During Unprotected
5. IFSTA [2008]. Essentials of fire fighting, 5th ed. Stillwater, OK: Fire Protection Publications, International Fire Service Training Association, Oklahoma State University.
6. NFPA [2008]. NFPA 1521. Standard for Fire Department Safety Officer. 2008 Edition.
7. Dunn, V [1988]. Collapse of burning buildings: a guide to fireground safety. Saddle Brook, NJ: Fire Engineering Books and Videos. 8. Firetactics.com [2007]. Model SOP standard operating procedure [http://www.firetactics.com/ Model%20SOP%20Standard%20Operating%20Procedure.pdf]. Date accessed: March 2009. 9. Dunn V [1992]. Safety and survival on the fire ground. Saddle Brook, NJ: Fire Engineering Books and Videos.
10. NFPA [2008]. Engine company fireground operations. Quincy, MA: National Fire Protection Association.
11. NFPA [1986]. Truck engine company fireground operations, 2nd ed. Quincy, MA: National Fire Protection Association.
12. OSHA [1998]. 29 CFR Parts 1910 and 1926 Respiratory protection; final rule. Federal Register Notice 1218-AA05. Vol. 63, No. 5. January 8, 1998. Washington, DC: U.S. Department of
Labor, Occupational Safety and Health Administration. 13. Clark BA [2005]. 500 Maydays called in rookie school [http://www.firehouse.com/article/ 10498807/500-maydays-called-in-rookie-school].
14. USFA [2006]. Mayday CD Q133 firefighter safety: calling the Mayday and H134 calling the Mayday: hands on training. Emmitsburg, MD: U.S. Department of Homeland Security, U.S. Fire Administration, National Fire Academy. 15. Clark BA [2008]. Leadership on the line: firefighter Mayday doctrine—where are we now? [http://www.firehouse.com/podcast/10459336/leadership-on-the-line-firefighter-maydaydoctrine-where-are-we-now].
16. IAFC [2010]. Rules of engagement of structural firefighting [http://www.iafcsafety.org /image/ROE_Poster.pdf]. Date accessed: July 2011.
17. Grossman D, Christensen L [2008]. On combat: the psychology and physiology of deadly conflict in war and peace. 3rd ed. Millstadt, IL: Warrior Science Publications.
18. IAFF [2010]. IAFF Fire Ground Survival Program [http://www.iaff.org/hs/fgs/fgsindex.htm]. Date accessed: July 2011. Page 29 Report # F2011-02 Volunteer Fire Fighter Caught in a Rapid Fire Event During Unprotected
Search, Dies After Facepiece Lens Melts – Maryland 19. International Association of Fire Chiefs [2009]. Firefighter/EMT safety, health & survival: rules of engagement for firefighter [http://www.iafc.org/displayindustryarticle.cfm? articlenbr=39522]. Date accessed: July 2011.
20. Klaene BJ, Sanders RE [2000]. Structural fire fighting. Quincy, MA: National Fire Protection Association.
21. NIOSH [2009]. Workplace solutions: preventing deaths and injuries of fire fighters working above fire-damaged floors. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and
Health, DHHS (NIOSH) Publication No. 2009-114[ http://www.cdc.gov/niosh/docs/wpsolutions/2009-114/default.html]. 22. Corbin DE [2000]. Seeing is believing. Occupational Safety and Health 69(8):60–67. 23. Underwriters Laboratories [2009]. Structural stability of engineered lumber in fire conditions [http://www.ul.com/global/eng/pages/offerings/industries/buildingmaterials/fire/courses/structu ral/]. Date accessed: Mar 2012.
24. IFSTA [1998]. Essentials of fire fighting, 3rd ed. Stillwater, Ok: Fire Protection Publications, International Fire Service Training Association, Oklahoma State University. 25. FireRescue 1 [2008]. Fire attack: advancing hose lines. http://www.firerescue1.com/Columnists/Michael-Lee/articles/409511-Fire-Attack-AdvancingHose-Lines/. Date accessed: Mar 2012. 26. FireRecruit.com [2008]. Fireground Tactical Priorities – RECEO VS http://www.firerecruit.com/articles/426027-Fireground-Tactical-Priorities-RECEO-VS . Date accessed: Mar 2012. 27. Firetactics.com [2007] Rapid fire phenomenon [http://www.firetactics.com/RAPID%20
FIRE%20PHENOMENA%202007.pdf . Date accessed: Mar 2012.. 28. Hartin E [2005]. Why is compartment fire behavior training (CFBT) important [http://www.firehouse.com/article/10510694/why-is-compartment-fire-behavior-training-cfbtimportant]. Date accessed: March 2009. 29. Raffel S [1999]. Realistic live fire training to deal safely with flashover and backdraught. Fire Aust J [http://www.firetactics.com/SHAN%20RAFFEL%20IFE.htm]. Date accessed: March 2009.
30. NFPA [2008]. NFPA 1001: Standard for fire fighter professional qualifications. 2008 ed.
31. NFPA [2008]. NFPA 1021: Standard for fire officer professional qualifications. 2003 ed.
32. NIOSH [2007]. Career officer injured during a live fire evolution at a training academy dies two days later—Pennsylvania. Morgantown, WV: U.S. Department of Health and Human
33. NIOSH [2008]. Career fire fighter dies in wind driven residential structure fire—Virginia.
34. NIOSH [2009]. Volunteer fire fighter dies while lost in residential structure fire—Alabama.
35. NIOSH [2010]. Career probationary fire fighter and captain die as a result of rapid fire progression in a wind-driven residential structure fire—Texas. Morgantown, WV: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Fatality Assessment and Control Evaluation (FACE) Report F2009-11[http://www.cdc.gov/niosh/fire/reports/face200911.html]. 36. National Fire Fighter Near Miss Reporting System [2006]. Firefighter experiences near miss in flashover trailer training, Report 06-441[http://www.firefighternearmiss.com]. Date accessed: February 18, 2010. 37. National Fire Fighter Near Miss Reporting System [2006]. Engine crew surprised by sofa flare up, Report 06-428 [http://www.firefighternearmiss.com]. Date accessed: February 18, 2010. 38. National Fire Fighter Near Miss Reporting System [2006]. Facepiece damaged during live burn training, Report 07-903 [http://www.firefighternearmiss.com]. Date accessed: February 18, 2010. 39. National Fire Fighter Near Miss Reporting System [2006]. Problem with CAFS unit identified at live burn, Report 08-044 [http://www.firefighternearmiss.com]. Date accessed: February 18, 2010.
40. NFPA [2007]. NFPA 1981 Standard on open-circuit self-contained breathing apparatus, 2007 edition. Quincy, MA: National Fire Protection Association. Page 31 Report # F2011-02 Volunteer Fire Fighter Caught in a Rapid Fire Event During Unprotected
41. USFA [2009]. Press release: October 2009. USFA and NIST initiate study of SCBA thermal performance [http://www.usfa.dhs.gov/media/press/2009releases/102009.shtm]. Date accessed: January 9, 2010.
42. NFPA [1997]. Fire protection handbook, 18th ed. Quincy, MA: National Fire Protection
Association, pp1–42. 43. NFPA [2008]. NFPA 1221: Standard for installation, maintenance, and use of emergency services communication equipment, 2010 ed. Quincy, MA: National Fire Protection Association. Investigator Information This incident was investigated by Jay Tarley and Stephen Miles, Safety and Occupational Health
IAFC [2009]. Rules of engagement for structural firefighting, increasing firefighter survival. Draft manuscript developed by the Safety, Health and Survival Section, International Association of Fire Chiefs. Fairfax Va. March 2009. http://www.iafcsafety.org/downloads/Rules_of_Engagement.pdf. Page 32 Report # F2011-02 Volunteer Fire Fighter Caught in a Rapid Fire Event During Unprotected
Search, Dies After Facepiece Lens Melts – Maryland Appendix A: Incident Timeline The following timeline was constructed by integrating data from the fire department’s timeline t and estimations of time to complete tactical operations. The clock symbol indicates known times taken from dispatch center recordings and response data. The times are rounded off to the nearest minute. Fire Behavior Indicators & Conditions Time 1818 1819 Response & Fireground Operations 911 center receives call for a kitchen fire that was spreading and dispatches a first-alarm assignment. First Alarm Dispatched. E11, E10, E1, T1, T8, E292, E301, BC11 Front door to common stairway closed at this time. Smoke conditions from Side-C of structure. 1820 E11 fire fighter opens front to apartment building door and is met with high heat and heavy smoke. He immediately closes the door. 1821 Light smoke conditions on Side-A. Page 34 E11 arrives first due, establishes Incident Command and reports three story brick garden apartment with smoke showing.
IC reports E11 will be conducting an aggressive interior attack with an 1 ¾-inch handline E307, SQ303 dispatched 1822
IC reports switching to “Limited Command” due to rescue situation. 1823 E11 extends a 35-foot ladder to the left third floor apartment on Side A to remove frantic occupant. 1823 E10 on scene conducting a forward lay to E11. Report # F2011-02 Volunteer Fire Fighter Caught in a Rapid Fire Event During Unprotected