U.S. EPA (2004). Air Quality Criteria for Particulate Matter. (Vol I of II). Office of Research and Development, Research Triangle Park, NC. EPA-600/P-99-002aF. October 2004
Other documents for the same rulemaking (all, by stage)
References: 1,975 extracted, 0 linked to papers
Wageningen, NL Mar-June 1995 12-14 P, A, I at school PM2.5, PM10 None Janssen et al. (1999a) Longitudinal :E diary
Mpala, Kenya 1996-1998 5-75 2 years Undefined Optical MIE Ezzati and Kammen (2001) Linn et al. (1999) Tamura et al. (1996b)
PM Exposurea Metrics PM Size Measuredb London, UK 1997 9-11 5 day/season 3 seasons P, I, O PM2.5, PM10 Wheeler et al. (2000) Pooled
Zurich, CH 1998 Adults 12 h/day for 3 days P, I, O Pollen Riediker et al. (2000) Pooled Minneapolis/St. Paul,
MN Volunteers Spring, summer, fall 1999 24-64 2-15 P, I, O PM2.5 Adgate et al. (2002) Pooled Birmingham,
CO, NO2 Harrison et al. (2002) Pooled Santiago, Chile children 8 in 1998 20 in 1999 Winters 1998 & 1999 10-12 P, I, O PM2.5, PM10 NO2, O3 Rojas-Bracho et al. (2002) Pooled
PM concentrations without the large influences caused by smoking, cooking, and other indoor particle-generating activities. The EPA has a research program focused on understanding PM exposure characteristics and relationships. Within the program, longitudinal studies are being conducted on elderly participants with underlying heart and lung disease (COPD, patients with cardiac defibrillator, and myocardial infarction), an elderly environmental justice cohort, and asthmatics. These studies are being conducted in several cities throughout the United States and over several seasons (Rodes et al., 2001; Conner et al., 2001; Landis et al., 2001; Rea et al., 2001). A series of studies by Phillips et al. (1994, 1996, 1997a,b, 1998a,b, 1999) examined personal ETS exposure in several European cities. Participants varied by age and occupation. Respirable suspended particulate (RSP) concentrations were reported. These studies are not included in Table 5-4 because of their focus on ETS exposure (which is not the focus of this chapter). A small personal exposure study in Zurich, Switzerland was reported by Monn et al. (1997) for PM10. This study also is not listed in Table 5-4 because indoor and outdoor measurements were not taken simultaneously with the personal measurements and other details of the study were not published. 5-34 5.3.2.2 Microenvironmental Data
Usually, personal PM monitoring is conducted using integrated measurements over a 12- or 24-h period. As such, total PM exposure estimates based on PEM measurements do not capture data from individual microenvironments. Recent studies have examined PM concentrations in various microenvironments using a number of different types of instruments ranging from filter-based to continuous particle monitors. Details on the instruments used, measurements collected, and findings of these studies according to microenvironment (residential indoor, nonresidential indoor, and traffic-related) are summarized in Table 5-5. Those studies which collected microenvironmental data as part of a personal exposure monitoring study are summarized in Table 5-4 above. In general, the studies listed in Table 5-5 are relatively small, purposeful studies designed to provide specific data on the factors that affect microenvironmental concentration of PM from both ambient and nonambient sources. Recently published studies have used various types of continuous monitors to examine particle concentrations in specific microenvironments and resulting from specific activities. Continuous particle monitors such as the scanning mobility particle sizer (SMPS), aerodynamic particle sizer (APS), and Climet have been used to measure particle size distributions in residential microenvironments (Abt et al., 2000a; Long et al., 2000, 2001a; Wallace et al., 1997;
Wallace, 2000a; McBride et al., 1999; Vette et al., 2001; Wallace and Howard-Reed, 2002). These studies have been able to assess the infiltration factor for ambient particles to indoor microenvironments, as well as penetration factors and deposition rates. Continuous instruments are also a valuable tool for assessing the impact of particle resuspension caused by human activity. A semi-quantitative estimate of PM exposure can be obtained using personal nephelometers that measure PM using light-scattering techniques. Recent PM exposure studies have used condensation nuclei counters (1-s averaging time) and personal nephelometers (1-min averaging time) to measure PM continuously (Howard-Reed et al., 2000; Quintana et al., 2000; Magari et al., 2002; Lanki et al., 2002) in various microenvironments. These data have been used to identify the most important ambient and nonambient sources of PM, to provide an estimate of source strength, and to compare modeled time activity data and PEM 24-h mass data to nephelometer measurements (Rea et al., 2001). 5-35
Boston, MA 2 homes, 2 seasons, 6 days SMPS Long et al. (2000a)
Boston, MA 9 homes, 2 seasons SMPS Anuszewski et al. (1998)
Seattle, WA 9 homes, 18 days Leaderer et al. (1999) Southwest VA 58 homes, summer Nephelometer (Radiance) 5-36 Wallace et al. (1997); Wallace (2000b)
Reston, VA 1 home, 4 years SMPS Climet PAHs Black carbon 6 size bins; 100 size channels 0.01-0.4 µm Time activity data, whole-house air exchange rates. Continuous carbon monoxide; descriptive data for monitored pollutants; size profiles for six indoor particle sources. 0.3- to 0.5-µm particles linked to outdoor concentrations, frying, broiling; 0.5- to 2.5-µm particles related to cooking events; > 2.5-µm particles influenced by physical movement. Howard-Reed et al. (2000)
VOCs, indoor/outdoor in 18 paired homes at varying distances from traffic Harvard Impactors PM2.5 and PM10. EC was measured by reflectance of the PM2.5 filters. PAH also measured as indicator of diesel traffic. Outdoor PM10 and PM2.5 were approximately 15-20% higher at higher traffic streets than at the quiet streets on the same days. However, much larger differences were found for PAH and EC which are traffic specific. “This [study] supports the use [of] traffic related pollution mapping as an exposure proxy in large-scale epidemiologic studies into health effects of motorized traffic emissions.” Kingham et al. (2000) Huddersfield, Measured PM at ten homes of non-smokers, < 50 m and > 300 m from traffic Harvard Impactors PM2.5 and PM10 and
PAH. EC measured by filter reflectance. Median ratio = 1 (no indoor combustion sources). Found an absence of a spatial gradient, perhaps due to wind direction effects (e.g., sometimes upwind and sometimes downwind of traffic). Morawska et al. (2001) Brisbane, Australia Measured PM indoors and outdoors at 16 homes while residents were absent. Air exchange rate estimated, not measured Scanning mobility particle sizer, aerodynamic particle sizer, and a TSI Dust Trak
Submicron PM, supramicron PM, PM2.5 For supra- and submicron particles, indoor = outdoor for normal ventilation conditions of > 2 air changes/hour. Average outdoor PM concentrations are good estimates of average indoor concentrations of PM of ambient origin for air exchange rates of > 0.5/h. Abraham et al. (2002) Measured ultrafine PM in various home and traffic microenvironments
TSI 8525 < 1 :m optical diameter 1-second readings collected while noting presence of sources. The TSI 8525 is a useful instrument for screening UFPM in microenvironments. Geller et al. (2002) Comparison of indoor and outdoor PM in homes in Coachella Valley, CA
USC Personal PM 5 Lpm PM2.5 and PM10-2.5 I2.5 = 4.3 + 0.74 O I10-2.5 = 3 + 0.3 O I EC = 0.84 O EC I OC > O OC. Thirteen volunteers had two to four 23-h measurements I and O analyzed for elemental carbon (EC) and organic carbon (OC). Some unoccupied homes measured. Gotschi et al. (2002) Measured Black Smoke (BS) by reflection from PM2.5 filters for 4 European cities, indoor and outdoor.
BS is a supplementary measurement that can be made on PM2.5 filters as an indication of EC. Sarnat et al. (2002) Measured PM2.5 for sulfate analysis in and out of 6 Boston homes Harvard Impactors with
SMPS and APS particle counters PM2.5 The ratio of I/O PM2.5, sulfate and size sub-fractions are developed as a function of season and air exchange rate. Sulfur is primarily of outdoor origin and can be used to track ambient PM of similar (0.06-0.5 :m) AD, but different relations exist for ultrafine PM and coarse-mode PM < 2.5 :m AD. Wallace and Howard-Reed (2002) Measured ultrafine, fine and coarse PM in one Reston,
SMPS LASX Douce et al. (2001) ETS measured by 4 methods in smokers homes and offices 37 mm filter and XAD-4 resin backup Outdoor PM2.5: 37 µg/m3. PM10: 68 µg/m3; I/O PM2.5: 1.8-12.4; PM10: 4.7-10.0. Mean PM3.5 concentrations were 17-20 µg/m3 in smoking homes over nonsmoking homes. Ratios of particle counts at 1.0 and 5.7 m from the combustion source/activity were obtained. Proximity to source may help explain the existence of a personal cloud. 0.01-2.5 µm Temporal relationships between indoor and outdoor aerosol concentrations evaluated; penetration factors and deposition rates estimated. Fresno panel study empty residence. Diurnally variable indoor/outdoor aerosol concentration ratios because of resuspension from daytime activities. Penetration factors ranged from 0.5 to 0.9. Samples extracted and analyzed for UV absorption, fluorescence, solanesol, and scopoletin. Solanesol is best method of 4, but needs study of solanesol stability on filter. Not given 443 personal time-weighted average occupations samples of airborne dust. Nonresidential Microenvironments Bohadana et al. (2000) Manufacturing plant, woodworkers Donham et al. (2000) San Francisco, 34 poultry workers
NIOSH Method 0600 monitors probed respirators Total dust sampled indoor respiratory masks. Personal monitoring: 630 ± 980 µg/m3 (n = 210) ranging from 10-7730 µg/m3. Respirable dust constituted about 10% of total dust measured. Klepeis et al. (1996) San Francisco, Airport lounge, ETS
TSI 8510 piezobalance PM3.5 Estimated cigarette emission rate of 1.43 mg/min/cigarette. Personal exposures to ETS can be modeled in these types of microenvironments. Nieuwenhuijsen et al. (1999) Agricultural activities Average respirable fraction: 4.5 mg/m3. Teschke et al. (1999) Wood production, wood finishing, wood construction workers
PM .50 1,632 observations from 1979-1997. Arithmetic mean exposure: 7.93 mg/m3. Geometric mean exposure: 1.86 mg/m3.
TSI DustTrak Brauer and Mannetje (1998) Vancouver, BC Indoor restaurants, various smoking policies PM2.5 PM10 Nonsmoking: PM2.5 7-65 µg/m3; PM10 < 10-74 µg/m3 Restricted smoking (> 40% nonsmoking) PM2.5 11-163 µg/m3; PM10 24-89 µg/m3 Unrestricted smoking: PM2.5 47-253 µg/m3; PM10 51-268 µg/m3. Lee and Chang (1999) Hong Kong Indoor and outdoor 5 classrooms PM10 Indoor PM10: 30-470 µg/m3 Outdoor PM10: 20-617 µg/m3 Chan (2002) Hong Kong A Hong Kong Office monitored indoor and outdoor
Temp, RH and solar intensity influence In/Out. Wind speed has no effect. Levy et al. (2002)
Boston, MA TSI DustTrak 8520 PM counter calibrated to PM2.5 Measured inside and outside the various microenvironments tested, weekdays morning and afternoon. At least 3 visits, several 10-min averages. 10-min outdoor averages are poor predictors of indoor values. 5-40 Baek et al. (1997) Korea
TSI P-Trak 8525 < 1 :m OD TABLE 5-5 (cont’d). SUMMARY OF RECENT MICROENVIRONMENTAL PM MEASUREMENT STUDIES Reference Study Description Instrument(s) Size Fraction (µm) Summary of Measurements Notes Traffic-Related Microenvironments (TRMs) 5-41 Praml and Schierl (2000) Munich, Germany Trams and buses, rural and urban Continuous millipore polycarbonate filter PM10 n = 201 4-h trips, mean concentration 155 µg/m3 range: 13-686 µg/m3 I/O: 2.8. Tram > circular bus route > radial bus route. Day > night. Monn et al. (1997) Switzerland Spatial scale from a city street Harvard microenvironment monitor PM10 48- or 72-h avg times; horizontal distance from street: 0, 15, 50, and 80 m; vertical distance from street: 20 m. Mean PM10 27.3 ± 3.0 µg/m3. No vertical gradient (0-20 m) and horizontal gradient (0-80 m) in distance from road, each about 13%. No significant differences between wet and dry periods. Rodes et al. (1998) Saevanenso, Los Angeles, CA
In-vehicle, various road types, 2-h trips PM2.5 Vehicles in front of the monitored vehicle accounted for most of the in-vehicle commuting exposure; average I/O: 0.6-0.8 h-1 for PM2.5; carpool lane concentrations were 30-60% lower than noncarpool lane concentrations. Air exchange rates measured at various ventilation settings and speeds. Monitoring vehicle followed a diesel bus or truck. Roorda-Knape et al. (1998) van Vliet et al. (1997) Netherlands Gradient in distance from roadway Harvard impactor PM2.5 PM10 Black smoke
PM monitoring at 50, 100, 150, and 300 m from roadway; 1-week avg time. No concentration gradient with increasing distance from the roadways for PM2.5 and PM10; concentration gradient did exist for black smoke, also found an effect with wind direction. Houseman et al. (2002)
TSI DustTrak PM10 Vehicle concentrations ranged from 33-170 µg/m3. Outdoor vehicle concentrations ranged from 40-144 µg/m3. Bus concentrations: 17-268 µg/m3; outdoor 10-203 µg/m3. Subway: 28-174 µg/m3; outdoor 8-203 µg/m3. The average in-vehicle to outdoor ratio was 0.99. Average I/O: 3; subway values were correlated with outdoor concentrations. Brauer et al. (1999)
Vancover, BC Commuting environments APC-1000 Janssen et al. (1997) Netherlands Background and roadway PM10
London, UK PM by volunteers in TRM in London, UK 16 L/min personal monitor. Porous foam size selector PM2.5 Volunteers rode/cycled along fixed routes repetitively. Personal exposures were generally double those at fixed-site ambient station. Subway exposures are maximal. Alm et al. (1999)
Kuopio, Finland 9-km commuter route, rush hours 1/mo Climet 6 channels Windows closed, vents open air exchange rate 36-47 h-1. Morning commutes were generally higher than afternoon commutes; relationships determined between PM and wind speed and vehicle speed. Chan et al. (2002) Hong Kong
PM measured in TRM in Hong Kong TSI 8520 DustTrac Calibrated to Partisol PM2.5 HiVol PM10 PM2.5 and PM10 Repetitive sampling over 8 fixed routes. Highly variable by mode. Tram exposures are maximal. Hoek et al. (2001) Hoek et al. (2002)
GIS used to interpolate background and regional ambient BS with added increment for distance to traffic < 50 m and < 100 m. May be useful technique. Estimates not validated with BS measurements at interpolated loci. Jinsart et al. (2002) Bangkok
Bangkok, Thailand Sibata personal single nozzle 2.5 L/min PM2.5 and PM10 Sampled 12-h while on duty at post at intersection. Exposures of both PM2.5 and PM10 higher than ambient PM measured at station with $ gauge. Not comparable to U.S. conditions. Lena et al. (2002) New York, NY PM2.5 and EC in the Bronx,
EEL for BS PM2.5 Sampled 10-h at sidewalk locations while counting cars and trucks for 3-weeks in summer of 1999.
EC is a large component of diesel PM2.5 and varies with truck traffic. Zhu et al. (2002) Los Angeles, CA Ultrafine near Interstate Highway in Los Angeles,
COPD patients have (1) smaller personal clouds and (2) higher correlations between personal exposure and ambient concentrations compared to healthy elderly, children, and the general population. The analysis by Wallace (2000a) and three subsequent longitudinal studies (Williams 2000a,b,c; Ebelt et al., 2000; Sarnat et al., 2000) supported hypothesis 1 but not hypothesis 2. Özkaynak and Spengler (1996) showed that at least 50% of personal PM10 exposure for the general population comes from ambient particles. Wilson and Suh (1997) concluded that fine and coarse particles should be treated as separate classes of pollutants because of differences in characteristics and potential health effects. Wilson et al. (2000) gave a review of what they call the “exposure paradox” and determined that personal PM needs to be divided into different classes according to source type and that correlations between personal and ambient PM will be higher when nonambient sources of PM are removed from the personal PM 5-43
PTEAM (Özkaynak et al., 1990; Spengler et al., 1989; Wiener 1988, 1989; Wiener et al., 1990)
THEES (Lioy et al., 1990) Amsterdam COPD (Janssen et al., 1997, 1998a) Boston COPD (Rojas-Bracho et al., 2000) Examines the differences between pooled and longitudinal correlations in personal and ambient (or outdoor) data for PM2.5 and PM10. Median longitudinal correlation coefficient is much higher than the pooled correlation coefficient for the same data sets. Personal cloud for PM10: 3-67 µg/m3; PM2.5 6-27 µg/m3. Personal cloud for elderly COPD was much smaller (PM10: 6-11 µg/m3; PM2.5 . 6 g/m3) than for other healthy populations (PM10: 27-56 µg/m3; PM2.5: 11-27 µg/m3) of elderly, children, and the general population. However, correlations of personal exposure with ambient concentrations were not higher for elderly COPD than for other groups. Özkaynak and Spengler (1996) Dockery and Spengler (1981)
PTEAM (Özkaynak et al., 1996a,b) Netherlands (Janssen et al., 1995) Discusses the personal cloud for PM2.5 and PM10. Hypothesizes that COPD patients have (1) smaller personal clouds (supported) and (2) higher correlations of personal exposure with outdoor concentrations because of reduced mobility (not supported). Uses statistical modeling techniques to examine the relationship between ambient PM concentrations and personal exposures. Data analysis involves use of air exchange rates, penetration factors, and June 25, 2004 ratios, as well as examining exposure in various microenvironments (traveling, working, outdoors, indoors) activities (exposure to smoke, cooking), and source strengths. The important components of personal exposures are received during contact with indoor sources, mainly in homes and work places. Ambient aerosols contribute about 50% or more to the personal PM10 exposures of the general population. The contribution of ambient aerosols to the total toxicity of inhaled particles is significant. 5-44 Brown and Paxton (1998)
THEES (Lioy et al., 1990) PTEAM pilot (Wallace, 1996) Boston and Nashville COPD (Rojas-Bracho et al., 2000); Bahadori et al., 1998) Cross-sectional and longitudinal regression analysis on data sets. Individual personal PM exposure is subject to high variability, which makes the personal-to-ambient PM relationship difficult to predict. Wilson and Suh (1997) Philadelphia (Burton et al., 1996; Suggs and Burton, 1983) Determines the utility of fine and coarse PM concentrations as indicators of time-series epidemiology with regard to day-today variability, area uniformity, and June 25, 2004 PM ratios. Fine and coarse particles should be considered separate classes of pollutants.
EPA AIRS database Wilson et al. (2000) New Jersey (Lioy et al., 1990) Japan (Tamura et al., 1996a)
PTEAM (Clayton et al., 1993; Özkaynak et al., 1996a,b) Netherlands (Janssen, 1998a; Suh et al., 1992) Necessary to treat personal exposure to ambient PM and personal exposure to nonambient PM as separate components of total personal PM exposure. Fixed-site ambient fine-particle measurements likely give a reasonable indication of the variability in the concentration of ambient fine particles across the community. Coarse-particle measurements most likely will not. Synoptic review of the “exposure paradox”: low correlations between personal exposure and ambient PM concentrations in spite of the existence of statistical association between ambient
PTEAM (Clayton et al., 1993; Özkaynak et al., 1996a,b) Examines the influence of nonambient PM on total PM concentrations and how it may confound the outdoor/personal
PTEAM (Clayton et al., 1993; Özkaynak et al., 1993, 1996a,b) Uses a reduced-form mass-balance model to predict the average fraction of ambient PM to which the average person is exposed. On average, a person is exposed to > 75% of ambient PM2.5 and > 64% of ambient PM10 measured by the community monitor.
Monn (2001) Multiple Literature Review Objective review of literature published since 1996 as an implicit update to the 1996 U.S. EPA PM AQCD. Emphasis on European studies. “It is important to note that a personal measurement does not a priori provide more valid data than a stationary ambient measurement, i.e. a personal sample in a study investigating effects from outdoor combustion particles is often influenced by sources other than outdoor sources and may thus confound the exposure-effect outcome.” Exposure to ambient PM is highly correlated in time with ambient PM concentrations measured at a community site. Indoor PM does not confound the relationship between daily mortality and ambient PM. 5-45 “Despite some lack of correlation between personal (PM10) and outdoor values, outdoor fine particle concentrations were strongly associated with mortality and morbidity indicating that outdoor sources (e.g. vehicular emissions) emit the toxic entity” (Dockery et al., 1993; Schwartz et al., 1996). Rotko et al. (2000a) Jantunen et al. (1998) Carrer et al. (1997) Koistinen et al. (1999) Compares exposure relationships between the six EXPOLIS European cities (Athens, Basel, Grenoble, Helsinki, Milan,
Mage (1998) conducted analysis using the PTEAM data and showed that the average person in PTEAM (Riverside, CA in the fall) was exposed to > 75% of ambient PM2.5 and > 64% of ambient PM10. Mage et al. (1999) used an algorithm to fill in missing data and outliers to analyze data sets and showed that variation in daily personal exposures for subjects with similar activity patterns and no ETS exposure are driven by variation in ambient PM concentrations. 5.3.3 Factors Influencing and Key Findings on Particulate Matter Exposures 5.3.3.1 Relationship of Personal/Microenvironmental Particulate Matter with Ambient Particulate Matter Understanding the relationship between ambient site measurements and personal exposure to PM is important for several reasons. First, it allows us to examine the extent to which ambient measurements for PM and various PM constituents can serve as valid surrogates for exposure to ambient PM or ambient constituents of PM in epidemiological studies. Second, it provides information that may improve surrogate exposure measurements and, hence, increase the power of epidemiologic studies. Finally, because compliance with the NAAQS is based on