U.S. EPA (2004) Air Quality Criteria for Particulate Matter. (Vol II of II). Office of Research and Development, Research Triangle Park, NC. EPA-600/P-99-002bF. October 2004
Other documents for the same rulemaking (all, by stage)
References: 1,752 extracted, 0 linked to papers
GAM Poisson models used more stringent convergence criteria, as suggested by Dominici et al. (2002): the convergence precision (epsilon) was set to 10-14, and the maximum iteration was set to 1000 for both the local scoring and back-fitting algorithms. The GLM model specification approximated the original GAM models. Natural splines were used for smoothing terms. To model time trend, the same degrees of freedom as the smoothing splines in the GAM models 8-180
HOSPITAL ADMISSION STUDIES Reference Outcome Measures Moolgavkar (2000c )*
COPD Lippmann et al. (2000)* COPD Mean Levels µg/m3 PM10-2.5 = 12 Co-Pollutants Measured Method Default GAM 5.1% (!0.4, 10.9) SO2, O3, NO2,
NS GLM 5.5 (!2.7 11.1) 5.5 (0, 14.0) Reanalysis by Ito (2003) Lippmann et al. (2000)* Pneumonia PM10-2.5 = 12 SO2, O3, NO2,
CO, H+ Reanalysis by Ito (2003) Sheppard et al. (1999)* Asthma PM10-2.5 = 16.2
CO, O3, SO2 Reanalysis by Sheppard (2003) Effect Estimates (95% CL) (% increase per 25 ug/m3)
NS = Natural Spline General Linear Model; PS = Penalized Spline General Additive Model. were used, with the default placement of knots. For weather models, to approximate LOESS smoothing with a span of 0.5 in the GAM model, natural splines with degrees of freedom were used. Generally, the GAM models with stringent convergence criteria and GLM models resulted in somewhat smaller estimated relative risks than those reported in the original study, e.g., for pneumonia admissions in Table 8-23. It was found that the reductions in the estimated relative risks were not different across the PM indices. Thus, conclusions of the original study about the relative roles of PM components by size and chemical characteristics remained unaffected. Lumley and Heagerty (1999) illustrate the effect of reliable variance estimation on data from hospital admissions for respiratory disease on King County, WA for eight years (1987-94), together with air pollution and weather information, using estimating equations and weighted empirical variance estimators. However, their weather controls were relatively crude (i.e., 8-181
GAM analysis with stricter convergence criteria, and the GLM analysis with natural splines. For pollutants that required imputation (i.e., estimation of missing value) estimates ignoring (single imputation) or adjusting for (multiple imputation) the imputation are shown. Source: Sheppard (2003). Burnett et al. (1997a) evaluated the role that the ambient air pollution mix, comprised of gaseous pollutants and PM indexed by various physical and chemical measures, plays in exacerbating daily admissions to hospitals for cardiac diseases and for respiratory diseases 8-184 (tracheobronchitis, chronic obstructive lung disease, asthma, and pneumonia). They employed daily measures of PM2.5 and PM10-2.5, aerosol chemistry (sulfates and H+), and gaseous pollutants (O3, NO2, SO2, CO) collected in Toronto, Ontario, Canada, during the summers of 1992, 1993, and 1994. Positive associations were observed for all ambient air pollutants for both respiratory and cardiac diseases. Ozone was the most consistently significant pollutant and least sensitive to adjustment for other gaseous and particulate measures. The PM associations with respiratory hospital admissions were significant for: PM10 (RR = 1.11 for 50 µg/m3; CI: 1.05, 1.17); PM2.5 (fine) mass (RR = 1.09 for 25 µg/m3; CI: 1.03, 1.14);PM10-2.5 (coarse) mass (RR = 1.13 for 25 µg/m3; CI: 1.05, 1.20); sulfate levels (RR = 1.11 for 155 nmoles/m3 = 15 µg/m3;
ED visits in Atlanta where mean PM10 = 39 µg/m3 and maximum PM10 = 105 µg/m3. The Lipsett et al. (1997) study of winter air pollution and asthma emergency visits in Santa Clara Co, CA, may provide insight where one of the principal sources of PM10 is residential wood combustion (RWC). Their results demonstrate an association between PM10 levels and asthma. Also of interest, Delfino et al. (1997a) found significant PM10 and PM2.5 associations for respiratory ED visits among older adults in Montreal when mean PM10 =21.7 µg/m3 and mean PM2.5 = 12.2 µg/m3. Hajat et al. (1999) also reported significant PM10 associations with asthma doctor’s visits for children and young adults in London when mean PM10 = 28.2 µg/m3 and the PM10 90th percentile was only 46.4 µg/m3. Overall, then, several new medical visits studies indicate 8-188
MEDICAL VISIT STUDIES Outcome Measures Mean Levels (µg/m3) Co-Pollutants Measured Method Effect Estimate* (95% CL) Choudhury et al. (1997) Asthma 41.5 Not considered 20.9 (11.8, 30.8) Lipsett et al. (1997) Asthma 61.2 NO2, O3 34.7 (16, 56.5) at 20 °C Tolbert et al. (2000b) Asthma 38.9 13.2 (1.2, 26.7) Tolbert et al. (2000a)** Asthma 29.1 NO2, O3, CO, SO2 8.8 (!8.7, 54.4) Asthma 19.4 NO2, O3, CO, SO2 2.3 (!14.8, 22.7) Asthma 9.39 NO2, O3, CO, SO2 21.1 (!18.2, 79.3) Reference PM10 PM2.5 Tolbert et al. (2000a)** PM10-2.5 Tolbert et al. (2000a)** * Effect estimates derived from single-pollutant models. **Preliminary results based on emergency department visit data from 18 of 33 participating hospitals.
PM exposure effects on lung function and respiratory symptoms, respectively, in asthmatic subjects; and key quantitative results are summarized in Table 8-25 for PM10 and Table 8-26 for PM2.5. The peak flow analyses results for asthmatics tend to show small decrements for PM10 and PM2.5 as seen in studies by Gielen et al. (1997), Peters et al. (1997c), Romieu et al. (1997), and Pekkanen et al. (1997). For PM10, the available point estimates for morning PEF lagged one day showed decreases, but the majority of the studies were not statistically significant (as per Table 8-25 and as shown in Figure 8-13 as an example of PEF outcomes). Lag 1 may be more relevant for morning measurement of asthma outcome from the previous day. The figure presents studies which provided such data. The results were consistent for both AM and PM peak flow analyses. Effects using two- to five-day lags averaged about the same as did the zero to one-day lags, but had wider confidence limits. Similar results were found for the fewer PM2.5 studies. Of these, Pekkanen et al. (1997) and Romieu et al. (1996) found similar results for PM2.5 and PM10, while the study of Peters et al. (1997b) found slightly larger effects for PM2.5. Pekkanen et al. (1997) also reported changes in peak flow to be related to several sizes of
PM. The authors reported morning PEF changes of !0.970 (SE = 0.502) l(cm3) for particle number count (0.032 - 0.10 in size), !0.901 (0.536) for PM1.0-3.2, and !1.13 (SE = 0.478) for PM10. Peters et al. (1997c) report that the strongest effects on peak flow were found with ultrafine particles: PMMC 0.01-0.1: !1.21 (!2.13, !0.30); PMMC0.01-2.5: !1.01 (!1.92, !0.11); and PM10: !1.30 (!2.36, !0.24). Penttinen et al. (2001) using biweekly spirometry over 6 months on a group of 54 adult asthmatics found that FVC, FEV1, and spirometric PEFR were inversely, but mostly nonsignificantly-associated with ultrafine particle concentrations. Compared to the effect estimates for self-monitored PEFR, the effect estimates for spirometric
PEFR tended to be larger. The strongest associations were observed in the size range of 0.1 to 1 µm. In a further study, von Klot et al. (2002) evaluated 53 adult asthmatics in Erfurt, Germany in the winter of 1996-1997. Relationships were estimated from generalized estimating equations, adjusting for autocorrelation. Asthma symptoms were related to small 8-196
PER 50 µg/m3 PM10 INCREMENT Outcome Measure Mean Particulate Levels (Range) µg/m3 Co-Pollutants Measured Lag Structure Peters et al. (1997b) Evening PEFR 55 (?, 71) SO2, sulfate, H+ 2 day !2.31 (!4.53, !0.10) Timonen & Pekkanen (1997) Urban Evening PEFR 18 (?, 60) NO2, SO2 2 day !1.13 (!4.75, 2.52) Timonen & Pekkanen (1997) Suburban Evening PEFR 13 (?, 37) NO2, SO2 2 day 0.38 (!6.37, 7.13) Peters et al. (1996) Evening PEFR SO2, sulfate, PSA 5 day !1.12 (!2.13, !0.10) Reference Citation, Location, etc. Effect Measures Standardized to 50 µg/m3 PM10 Asthma Studies (cont’d) 8-198 Peters et al. (1997a) Evening PEFR 47 (29, 73) SO2, sulfate, H 1-5 day !1.34 (!2.83, 0.15) Timonen & Pekkanen (1997) Urban Evening PEFR 18 (?, 60) NO2, SO2 1-4 day !0.73 (!7.90, 6.44) Timonen & Pekkanen (1997) Suburban Evening PEFR 13 (?, 37) NO2, SO2 1-4 day !4.18 (!20.94, 12.58) Hiltermann et al. (1998) Ave. AM & PM 39.7 (16, 98)
Ozone, NO2, SO2 1 day !0.90 (!3.84, 2.04) Hiltermann et al. (1998) Ave. AM & PM 39.7 (16, 98)
Ozone, NO2, SO2 2 day !0.50 (!4.22, 3.22) Hiltermann et al. (1998) Ave. AM & PM 39.7 (16, 98)
Overall, then, PM10 and PM2.5 both appear to affect lung function in asthmatics, but there is only limited evidence for a stronger effect of fine versus coarse fraction particles; nor do ultrafine particles appear to have any notably stronger effect than other larger-diameter fine particles. Also, of the studies provided, few if any analyses were able to clearly separate out the effects of PM10 and PM2.5 from other pollutants. The effects of PM10 on respiratory symptoms in asthmatics tended to be positive, although they are somewhat less consistent than PM10 effects on lung function. Most studies showed increases in cough, phlegm, difficulty breathing, and bronchodilator use, although these increases were generally not statistically significant for PM10 (see Tables 8-27, 8-28, 8-29, and 8-30; and, for cough as an example, see Figure 8-14). Vedal et al. (1998) reported that (a) increases in PM10 were associated with increased reporting of cough, phlegm production, and sore throat and (b) children with diagnosed asthma are more susceptible to the effects than are other children. Similarly, in the Gielen et al. (1997) study of a panel of children, most of whom had asthma, low levels of PM increased symptoms and medication use. The Peters et al. (1997b) 8-199
Location, etc. Outcome Measure Mean Particulate Levels (Range) µg/m3 Co-Pollutants Measured Structure Effect Measures Standardized to 50 µg/m3 PM10 Vedal et al. (1998)
OR cough 55 (?, 71) SO2, sulfate, H+ 0 day 1.32 (1.16, 1.50) Peters et al. (1997c)
OR nocturnal cough 34.2 (9, 95) SO2, NO2 2 day (values not given because not significant) Neukirch et al. (1998)
OR nocturnal cough 34.2 (9, 95) SO2, NO2 3 day (values not given because not significant) Romieu et al. (1996)
OR cough 55 (?, 71) SO2, sulfate, H+ 1-5 day 1.30 (1.09, 1.55) Peters et al. (1997c)
Location, etc. Outcome Measure Mean Particulate Levels (Range) µg/m3 Co-Pollutants Measured Structure Effect Measures Standardized to 50 µg/m3 PM10 Gielen et al. (1997)
OR bronchodilator use 30.5 (16, 60) Ozone 0 day 0.94 (0.59, 1.50) Hiltermann et al. (1998)
OR bronchodilator use 39.7 (16, 98) Ozone, NO2, SO2 0 day 1.03 (0.93, 1.15) Peters et al. (1997c)
OR bronchodilator use 47 (29, 73) SO2, sulfate, H+ 0 day 1.06 (0.88, 1.27) Gielen et al. (1997)
OR bronchodilator use 30.5 (16, 60) Ozone 2 day 2.90 (1.81, 4.66) Hiltermann et al. (1998)
OR bronchodilator use 39.7 (16, 98) Ozone, NO2, SO2 1-7 day 1.12 (1.00, 1.25) Peters et al. (1997c)
Location, etc. Outcome Measure Mean Particulate Levels (Range) µg/m3 Co-Pollutants Measured Structure Effect Measures Standardized to 25 µg/m3 PM2.5 Peters et al. (1997c)
Location, etc. Outcome Measure Mean Particulate Levels (Range) µg/m3 Co-Pollutants Measured Structure Effect Measures Standardized to 50 µg/m3 PM10 Gold et al. (1999) Morning PEFR 51 (23, 878) Ozone 1 day !0.20 (!0.47, 0.07) Tiittanen et al. (1999) Morning PEFR 28 (5, 122) NO2, SO2, CO, ozone 0 day 1.21 (!0.43, 2.85) Neas et al. (1999) Morning PEFR Ozone 1-5 day 2.64 (!6.56, 11.83) Tiittanen et al. (1999) Morning PEFR 28 (5, 122) NO2, SO2, CO, ozone 1-4 day !1.26 (!5.86, 3.33) Boezen et al. (1999)
OR > 10% AM PEFR Decr. 42 (5, 146) NO2, SO2 1-5 day 1.05 (0.91, 1.21) Neas et al. (1999) Morning PEFR Ozone 0 day !8.16 (!14.81, !1.55) Harré et al. (1997) % change in morning PEFR (not given) NO2, SO2, CO 1 day 0.07 (!0.50, 0.63) Neas et al. (1999) Evening PEFR Ozone 0 day !1.44 (!7.33, 4.44) Schwartz & Neas (2000) Uniontown Evening PEFR (not given) Sulfate fraction 0 day !1.52 (!2.80, !0.24) Schwartz & Neas (2000) State College Evening PEFR (not given) Sulfate fraction 0 day !0.93 (!1.88, 0.01) Tiittanen et al. (1999) Evening PEFR 28 (5, 122) NO2, SO2, CO, ozone 0 day 0.72 (!0.63, 1.26) Tiittanen et al. (1999) Evening PEFR 28 (5, 122) NO2, SO2, CO, ozone 0 day 2.33 (!2.62, 7.28) Gold et al. (1999) Evening PEFR 51 (23, 878) Ozone 0 day !0.14 (!0.45, 0.17) Neas et al. (1999) Evening PEFR Ozone 1-5 day 1.47 (!7.31, 10.22) Boezen et al. (1999)
OR > 10% PM PEFR Decr. 34 (?, 106) NO2, SO2, sulfate 0 day 1.44 (1.02, 2.03) Van der Zee et al. (1999)
OR > 10% PM PEFR Decr. 34 (?, 106) NO2, SO2, sulfate 2 day 1.14 (0.83, 1.58) Van der Zee et al. (1999)
OR > 10% PM PEFR Decr. 34 (?, 106) NO2, SO2, sulfate 1-5 day 1.16 (0.64, 2.10) Harré et al. (1997) % change in evening PEFR (not given) NO2, SO2, CO 1 day !0.22 (!0.57, 0.16)
OR cough – no other symptoms (not given) Sulfate fraction 0 day 1.20 (1.07, 1.35) Boezen et al. (1998)
OR cough 42 (5, 146) NO2, SO2 0 day 1.06 (0.93, 1.21) Van der Zee et al. (1999) Urban areas
OR cough 34 (?, 106) NO2, SO2, sulfate 0 day 1.04 (0.95, 1.14) Tiittanen et al. (1999)
OR cough 28 (5, 122) NO2, SO2, CO, ozone 0 day 1.00 (0.87, 1.16) Van der Zee et al. (1999) Urban areas
OR cough 34 (?, 106) NO2, SO2, sulfate 2 day 0.94 (0.89, 1.06) Van der Zee et al. (1999) Urban areas
OR phlegm 28 (5, 122) NO2, SO2, CO, ozone 2 day Positive but not significant Schwartz & Neas (2000) (not given) Sulfate fraction 0 day Van der Zee et al. (1999) Urban areas 34 (?, 106) NO2, SO2, sulfate 0 day 0.98 (0.89, 1.08) Van der Zee et al. (1999) Urban areas 34 (?, 106) NO2, SO2, sulfate 2 day 1.01 (0.93, 1.10) Reference Citation,
Location, etc. Schwartz & Neas (2000) 8-208
Location, etc. Outcome Measure Mean Particulate Levels (Range) µg/m3 Co-Pollutants Measured Structure Effect Measures Standardized to 25 µg/m3 PM2.5 Gold et al. (1999) Morning PEFR 30.3 (9, 69) Ozone 1 day !0.22 (!0.46, 0.01) Tiittanen et al. (1999) Morning PEFR NO2, SO2, CO, ozone 0 day 1.11 (!0.64, 2.86) Tiittanen et al. (1999) Morning PEFR NO2, SO2, CO, ozone 1-4 day !1.93 (!7.00, 3.15) Neas et al. (1999) Morning PEFR 24.5 (?, 88) Ozone 1-5 day 2.64 (!6.56, 11.83) Schwartz & Neas (2000) Uniontown Evening PEFR (not given) Sulfate fraction 0 day !1.52 (!2.80, !0.24) Schwartz & Neas (2000) State College Evening PEFR (not given) Sulfate fraction 0 day !0.93 (!1.88, 0.01) Tiittanen et al. (1999) Evening PEFR NO2, SO2, CO, ozone 0 day 0.70 (!0.81, 2.20) Tiittanen et al. (1999) Evening PEFR NO2, SO2, CO, ozone 0 day 1.52 (!3.91, 6.94) Gold et al. (1999) Evening PEFR 30.3 (9, 69) Ozone 0 day !0.10 (!0.43, 0.22) Neas et al. (1999) Evening PEFR 24.5 (?, 88) Ozone 1-5 day 1.47 (!7.31, 10.22) Tiittanen et al. (1999)
OR cough 15 (3, 55) NO2, SO2, CO, ozone 0 day 1.04 (0.86, 1.20) Tiittanen et al. (1999)
OR cough 15 (3, 55) NO2, SO2, CO, ozone 2 day 1.24 (1.02, 1.51) Schwartz & Neas (2000)
Location, etc. Outcome Measure Mean Particulate Levels (Range) µg/m3 Co-Pollutants Measured Structure Effect Measures Standardized to 25 µg/m3 PM10-2.5 Tiittanen et al. (1999) Morning PEFR 8 (.2, 67) NO2, SO2, CO, ozone 1 day !1.26 (!2.71, 0.18) Neas et al. (1999) Morning PEFR Ozone 1 day !4.31 (!11.43, 2.75) Tiittanen et al. (1999) Morning PEFR 8 (.2, 67) NO2, SO2, CO, ozone 2 day 0.51 (!0.77, 2.16) Tiittanen et al. (1999) Morning PEFR 8 (.2, 67) NO2, SO2, CO, ozone 1-4 day !0.57 (!1.96, 0.81) Neas et al. (1999) Morning PEFR Ozone 1-5 day !6.37 (!21.19, 8.44) Tiittanen et al. (1999) Evening PEFR 8 (.2, 67) NO2, SO2, CO, ozone 0 day 0.66 (!0.33, 1.81) Neas et al. (1999) Evening PEFR Ozone 1 day 1.88 (!4.75, 8.44) Tiittanen et al. (1999) Evening PEFR 8 (.2, 67) NO2, SO2, CO, ozone 2 day 0.03 (!1.41, 1.47) Tiittanen et al. (1999) Evening PEFR 8 (.2, 67) NO2, SO2, CO, ozone 1-4 day 2.37 (!1.69, 4.96) Neas et al. (1999) Evening PEFR Ozone 1-5 day 5.94(!7.00, 18.94) Tiittanen et al. (1999)
OR cough 8 (.2, 67) NO2, SO2, CO, ozone 0 day 0.99 (0.87, 1.12) Tiittanen et al. (1999)
OR cough 8 (.2, 67) NO2, SO2, CO, ozone 2 day 1.23 (1.06, 1.42) Tiittanen et al. (1999)
OR cough 8 (.2, 67) NO2, SO2, CO, ozone 1-4 day 1.31 (0.81, 2.11) Schwartz & Neas (2000)
OR cough without other symptoms (not given) Sulfate fraction 0 day 1.77 (1.24, 2.55) Schwartz & Neas (2000)
Wheeze, bronchitis, respiratory infections, and runny nose were not related to PM2.5 levels. Other non-U.S. studies examined PM measures such as TSP and BS in European countries. In Germany, Heinrich et al. (2000) reported a cross-sectional survey of children, conducted twice (with the same 971 children included in both surveys). TSP levels decreased between surveys, as did the prevalence of all respiratory symptoms (including bronchitis). Also, Krämer et al. (1999) reported a study in six East and West Germany communities, which found decreasing yearly TSP levels to be related to ever-diagnosed bronchitis from 1991 to 1995.