{"document":{"doc_id":184755,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Cost projection of combined cycle power plants equipped with post-combustion carbon capture","date":"2024-05-09","url":"https://www.regulations.gov/document/EPA-HQ-OAR-2023-0072-8880","source_native_id":"EPA-HQ-OAR-2023-0072-8880","status":"fetched","abstract":null,"action":null},"dockets":["EPA-HQ-OAR-2023-0072"],"rins":["RIN 2060-AV71","RIN 2060-AV09"],"related":[{"doc_id":1171,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Regulatory Impact Analysis for the Proposed National Emission Standards for Hazardous Air Pollutants: Gasoline Distribution Technology Review and Standards of Performance for Bulk Gasoline Terminals Review","date":"2022-06-10"},{"doc_id":1173,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"RIA Support Citations","date":"2022-06-10"},{"doc_id":128461,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Gas Distribution Passback #2 for OMB","date":"2022-06-10"},{"doc_id":128462,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Gas Distribution Passback #2 for OMB","date":"2022-06-10"},{"doc_id":128463,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Gas Distribution Passback for OMB","date":"2022-06-10"},{"doc_id":128464,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"EO 12866 Passback #1 - Gasoline Distribution & Bulk Gas (2060-AU97)","date":"2022-06-10"},{"doc_id":128465,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Gas Distribution Package Submission to OMB","date":"2022-06-10"},{"doc_id":128466,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Redline of 40 CFR Part 63, Subpart R, Showing Proposed Amendments","date":"2022-06-10"},{"doc_id":128467,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Redline of 40 CFR Part 63, Subpart BBBBBB, Showing Proposed Amendments","date":"2022-06-10"},{"doc_id":128468,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Redline of 40 CFR Part 60, Subpart XX, Showing Proposed Amendments","date":"2022-06-10"},{"doc_id":175006,"source":"docket_item","org":"EPA","doc_type":"report","title":"Fleet Composition of Rail Tank Cars Carrying Flammable Liquids: 2019 Report.","date":"2022-06-10"},{"doc_id":175008,"source":"docket_item","org":"EPA","doc_type":"report","title":"Gasoline Distribution Area Source Baseline Emission Estimates for 2004 - Gasoline Distribution Area Source Baseline Emission Estimates for 2004","date":"2022-06-10"},{"doc_id":175010,"source":"docket_item","org":"EPA","doc_type":"report","title":"Gasoline Distribution Area Source Emission Reduction Estimates","date":"2022-06-10"},{"doc_id":175012,"source":"docket_item","org":"EPA","doc_type":"report","title":"EPA Air Pollution Control Cost Manual Chapter 1 Flares","date":"2022-06-10"},{"doc_id":175013,"source":"docket_item","org":"EPA","doc_type":"report","title":"AP 42, Fifth Edition, Volume I Chapter 5: Petroleum Industry Section 5.2 Transportation And Marketing Of Petroleum Liquids","date":"2022-06-10"},{"doc_id":175014,"source":"docket_item","org":"EPA","doc_type":"report","title":"Gasoline Distribution Area Source Control Cost Estimates","date":"2022-06-10"},{"doc_id":175015,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Survey of Control Technology for Storage Vessels and Analysis of Impacts for Storage Vessel Control Options","date":"2022-06-10"},{"doc_id":175020,"source":"docket_item","org":"EPA","doc_type":"report","title":"Analysis of Demographic Factors for Populations Living Near Gasoline Distribution Facilities","date":"2022-06-10"},{"doc_id":175023,"source":"docket_item","org":"EPA","doc_type":"data","title":"Basis for Emissions Equivalence Using Random Selection for Annual M21 – EPA Review Dataset.xlsx","date":"2022-06-10"},{"doc_id":192255,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Guideline Series: Control of Volatile Organic Emissions from Bulk Gasoline Plants","date":"2022-06-10"},{"doc_id":192256,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Alternative Control Techniques Document: Volatile Organic Liquid Storage in Floating and Fixed Roof Tanks","date":"2022-06-10"},{"doc_id":192257,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Protocol for Equipment Leak Emission Estimates","date":"2022-06-10"},{"doc_id":192258,"source":"docket_item","org":"EPA","doc_type":"publication","title":"40 CFR Part 60, Subpart XXa","date":"2022-06-10"},{"doc_id":192259,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Equipment leak detection and quantification at 67 oil and gas sites in the Western United States","date":"2022-06-10"},{"doc_id":192260,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Gasoline Distribution Industry (Stage I) - Background Information for Promulgated Standards","date":"2022-06-10"},{"doc_id":192261,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Bulk Gasoline Terminals - Background Information for Proposed Standards","date":"2022-06-10"},{"doc_id":192262,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Gasoline Distribution Industry (Stage I) - Background Information for Proposed Standards","date":"2022-06-10"},{"doc_id":192263,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Bulk Gasoline Terminals - Background Information for Promulgated Standards","date":"2022-06-10"},{"doc_id":205535,"source":"docket_item","org":"EPA","doc_type":"other","title":"Supporting Statement: Environmental Protection Agency, Standards of Performance for Bulk Gasoline Terminals, 40 CFR Part 60, Subpart XXa","date":"2022-06-10"},{"doc_id":205538,"source":"docket_item","org":"EPA","doc_type":"other","title":"EPA Air Pollution Control Cost Manual Chapter 2 Refrigerated Condensers","date":"2022-06-10"},{"doc_id":205539,"source":"docket_item","org":"EPA","doc_type":"other","title":"EPA Air Pollution Control Cost Manual Chapter 2 Incinerators and Oxidizers","date":"2022-06-10"},{"doc_id":205540,"source":"docket_item","org":"EPA","doc_type":"other","title":"California Air Resources Board (CARB) CP-204: Certification Procedure for Vapor Recovery Systems of Cargo Tanks","date":"2022-06-10"},{"doc_id":205543,"source":"docket_item","org":"EPA","doc_type":"other","title":"EPA Air Pollution Control Cost Manual Chapter 1 Carbon Adsorbers","date":"2022-06-10"},{"doc_id":216218,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Control Options for Loading Operations at Gasoline Distribution Facilities","date":"2022-06-10"},{"doc_id":216219,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"New Source Performance Standards Review for Bulk Gasoline Terminals","date":"2022-06-10"},{"doc_id":216220,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"John Zink VRU","date":"2022-06-10"},{"doc_id":216221,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for October 6, 2021 meeting between Representatives of Marathon Petroleum Corporation and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216223,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"ILTA's Supplemental Information Regarding EPA's Technology Review of Regulations in the Gasoline Distribution Source Category","date":"2022-06-10"},{"doc_id":216224,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Control Options for Storage Tanks at Gasoline Distribution Facilities","date":"2022-06-10"},{"doc_id":216225,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Major Source Technology Review for Gasoline Distribution Facilities (Bulk Gasoline Terminals and Pipeline Breakout Stations) NESHAP","date":"2022-06-10"},{"doc_id":216226,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for November 17, 2021 meeting between Representatives of American Petroleum Institute (API), John Zink Hamworthy Combustion, and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216227,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Control Options for Equipment Leaks at Gasoline Distribution Facilities","date":"2022-06-10"},{"doc_id":216228,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Voluntary Consensus Standard Results for Standards of Performance for Bulk Gasoline Terminal that Commenced Construction, Modification, or Reconstruction after [THE DATE OF PUBLICATION OF THE PROPOSED RULE IN THE FEDERAL]","date":"2022-06-10"},{"doc_id":216229,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for October 20, 2021 meeting between Representatives of International Liquid Terminals Association (ILTA), John Zink Hamworthy Combustion, and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216230,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"OMB concludes review of 2060-AU97","date":"2022-06-10"},{"doc_id":216231,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Letter from Harold Dinsmore, John Zink Company, to Costumer, regarding “Continuous Emission Monitors for Carbon Adsorption Based Vapor Recovery Systems.”","date":"2022-06-10"},{"doc_id":216232,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Monitoring Options and Costs for Gasoline Distribution Facilities","date":"2022-06-10"},{"doc_id":216233,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Area Source Technology Review for the Gasoline Distribution Bulk Terminal, Bulk Plants, and Pipeline Facilities NESHAP","date":"2022-06-10"},{"doc_id":216234,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Voluntary Consensus Standard Results for National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline Distribution Bulk Terminals, Bulk Plants, and Pipeline Facilities","date":"2022-06-10"},{"doc_id":216235,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for March 10, 2022 meeting between Representatives of International Liquid Terminals Association (ILTA) and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216236,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Gas Plant Component Count Data","date":"2022-06-10"},{"doc_id":216237,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Electronic Reporting Requirements for New Source Performance Standards (NSPS) and National Emission Standards for Hazardous Air Pollutants (NESHAP) Rules","date":"2022-06-10"},{"doc_id":216238,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for March 16, 2022 meeting between Representatives of American Petroleum Institute (API) and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216239,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for June 30, 2021 meeting between Representatives of International Liquid Terminals Association (ILTA) and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216240,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"SAN 8202 -NESHAP for the Gasoline Distribution Source Category & NSPS for Bulk Gas Terminals","date":"2022-06-10"},{"doc_id":216241,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for May 25, 2021 meeting between Representatives of International Fuel Terminal Operators Association (IFTOA) and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216242,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for April 13, 2021 meeting between Representatives of American Petroleum Institute (API) and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"},{"doc_id":216243,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Justification/Documentation of the Procedure Developed to Select Major Source Applicability Equations for the Proposed Gasoline Distribution (Stage I) NESHAP Regulation","date":"2022-06-10"},{"doc_id":216244,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Letter from Juliet Milan, Mobil Oil Guam, Inc., to Lornette Harvey, EPA Region 9, regarding Mobil Oil Guam Inc. Cabras Terminal and Mobil Oil Mariana Islands, Inc. Saipan Terminal Establishment of Continuous Emission Monitor (CEM) Operating Parameters for Vapor Recovery Units.","date":"2022-06-10"},{"doc_id":216245,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Record for June 8, 2021 meeting between Representatives of American Petroleum Institute (API) and Representatives of OAQPS (U.S. EPA)","date":"2022-06-10"}],"references":[{"citation_id":1739781,"raw_reference":"NETL (2014) Steam turbine NETL (2014) HRSG","cited_authors":"NETL","cited_year":"2014","cited_title":"Steam turbine NETL (2014) HRSG","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739782,"raw_reference":"NETL (2014) EGR gas turbine NETL (2014) Absorber Rubin et al. (2007) Stripper Rubin et al. (2007) Compressors","cited_authors":"NETL","cited_year":"2014","cited_title":"EGR gas turbine NETL (2014) Absorber Rubin et al","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739783,"raw_reference":"IEAGHG (2006) Intercooling system IEAGHG (2006) Power plant package","cited_authors":"IEAGHG","cited_year":"2006","cited_title":"Intercooling system IEAGHG (2006) Power plant package","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739784,"raw_reference":"PCC package CO2 compression package regeneration, respectively. It is worth mentioning that the electricity consumption for compression is not included, since this is not considered in the minimum work for the CO2 separation. On the other hand, the effect of the Wregen on the efﬁciency of the CO2 capture process was assessed in this study. Based on a previous simulation template built-in Thermoﬂex (DíazHerrera et al., 2020), the mass ﬂow of steam extracted from the NGCC to the reboiler varied from 100% (business-as-usual,","cited_authors":"PCC package CO2 compression package regeneration, respectively. It is worth mentioning that the electricity consumption for compression is not included, since this is not considered in the minimum work for the CO2 separation. On the other hand, the effect of the Wregen on the efﬁciency of the CO2 capture process was assessed in this study. Based on a previous simulation template built-in Thermoﬂex (DíazHerrera et al","cited_year":"2020","cited_title":"the mass ﬂow of steam extracted from the NGCC to the reboiler varied from 100% (business-as-usual","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739785,"raw_reference":"BAU value) to 0% (thermodynamics limit), by steps of 10%. Wfan and Wpump were not assessed because their contribution to the Wreal is much lower than the solvent regeneration process (Wilcox, 2012; Lindqvist et al., 2014; Liu, 2020). In addition, blowing and pumping have a much higher technological maturity than the solvent regeneration process, which means a higher energy efﬁciency; therefore, Wfan and Wpump show a lower energy-saving opportunity in the PCC plant compared to Wregen . Capital cost projection for a nth-of-a-kind plant bn \u0002 The method selected to calculate the CAPEX for a NOAK","cited_authors":"BAU value) to 0% (thermodynamics limit), by steps of 10%. Wfan and Wpump were not assessed because their contribution to the Wreal is much lower than the solvent regeneration process (Wilcox, 2012; Lindqvist et al., 2014; Liu","cited_year":"2020","cited_title":"In addition, blowing and pumping have a much higher technological maturity than the solvent regeneration process, which means a higher energy efﬁciency; therefore, Wfan and Wpump show a lower energy-saving opportunity in the PCC plant compared to Wregen . Capital cost projection for a nth-of-a-kind plant bn \u0002 The method selected to calculate the CAPEX for a NOAK","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739786,"raw_reference":"NGCC-CCS plant is based on Ref. (Roussanaly et al., 2021), which consists of a hybrid method combining the engineeringeconomic and the experience curve approaches.","cited_authors":"NGCC-CCS plant is based on Ref. (Roussanaly et al","cited_year":"2021","cited_title":"which consists of a hybrid method combining the engineeringeconomic and the experience curve approaches","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739787,"raw_reference":"NOAK plants. frontiersin.org Díaz-Herrera et al. 10.3389/fenrg.2022.987166 • For NOAK plants, the learning rate was only applied to","cited_authors":"NOAK plants. frontiersin.org Díaz-Herrera et al. 10.3389/fenrg","cited_year":"2022","cited_title":"987166 • For NOAK plants, the learning rate was only applied to","cited_venue":null,"cited_doi":"10.3389/fenrg.2022.987166","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739788,"raw_reference":"CAPEX. The projection costs of FOM, VOM, and TCO2 are assumed to be ﬁxed over time because the learning rates for O&M in CCS projects show a very low effect on the overall capture cost (Roussanaly et al., 2021). • The present work is limited to assessing the CO2 capture and geological storage cost in NGCC plants. The CO2 industrial utilization for commercial purposes (e.g., EOR, synthetic fuel production, beverages carbonation, etc.) is out of the scope of this paper. Economic indicators The economic indicators used in this study were the","cited_authors":"CAPEX. The projection costs of FOM, VOM, and TCO2 are assumed to be ﬁxed over time because the learning rates for O&M in CCS projects show a very low effect on the overall capture cost (Roussanaly et al","cited_year":"2021","cited_title":"• The present work is limited to assessing the CO2 capture and geological storage cost in NGCC plants","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739789,"raw_reference":"LCOE and the CAC, both reported in 2022 constantdollar. The LCOE was calculated using Eqs 6, 7 (Rubin et al., 2015):","cited_authors":"LCOE and the CAC, both reported in 2022 constantdollar. The LCOE was calculated using Eqs 6, 7 (Rubin et al","cited_year":"2015","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739790,"raw_reference":"FOM is the annual ﬁxed O&M costs ($/year); MW is the net power output (MW); CF is the plant capacity factor (%); VOM is the variable O&M costs ($/MWh); FC is the fuel cost per unit of energy ($/MJ); HR is the net power heat rate (MJ/MWh); TCO2 is the CO2 transport cost ($/MWh), SCO2 is the CO2 storage cost ($/MWh); r = interest rate (%); and T is the economic life of the plant (years). The CAC is an indicator that compares a power plant with a carbon mitigation technology to a “reference plant” without CO2 reduction technology and quantiﬁes the average cost of avoiding a unit of atmospheric CO2 emissions per MWh (Metz B et al., 2005). For all cases, the CAC is calculated using Eq. 8. For this work, conventional NGCC without capture (base case) is the reference plant. Table 3 shows the η2nd values for NGCC and EGR conﬁguration at different capture levels. For each case, η2nd increases as a function of the carbon capture level. The η2nd ranges from 14.2% to 15.2% and 13.3%–14.2% for NGCC and","cited_authors":"FOM is the annual ﬁxed O&M costs ($/year); MW is the net power output (MW); CF is the plant capacity factor (%); VOM is the variable O&M costs ($/MWh); FC is the fuel cost per unit of energy ($/MJ); HR is the net power heat rate (MJ/MWh); TCO2 is the CO2 transport cost ($/MWh), SCO2 is the CO2 storage cost ($/MWh); r = interest rate (%); and T is the economic life of the plant (years). The CAC is an indicator that compares a power plant with a carbon mitigation technology to a “reference plant” without CO2 reduction technology and quantiﬁes the average cost of avoiding a unit of atmospheric CO2 emissions per MWh (Metz B et al","cited_year":"2005","cited_title":"For all cases, the CAC is calculated using Eq","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739791,"raw_reference":"EGR cases, respectively. This result is in good agreement with those published in the literature (Bolland and Undrum, 2003; Lindqvist et al., 2014; Liu et al., 2017). The increments on η2nd are because the Wreal required for the CO2 separation is reduced as a function of the capture level. Additionally, at a speciﬁc capture rate, we can see that EGR shows a lower Wfan values than NGCC. This is because of the lower amount of ﬂue gases to be treated in the PCC plant. Meanwhile, Wregen and Wpump presents similar values for both cases, which is due to optimization work done for sizing the absorber and stripper columns (Díaz-Herrera et al., 2020), which results in similar values in the reboiler duty and power consumption for solvent pumping, respectively. For example, the reboiler duty for","cited_authors":"EGR cases, respectively. This result is in good agreement with those published in the literature (Bolland and Undrum, 2003; Lindqvist et al., 2014; Liu et al","cited_year":"2017","cited_title":"The increments on η2nd are because the Wreal required for the CO2 separation is reduced as a function of the capture level","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739792,"raw_reference":"CAC ($ tCO2 ) \u0002 \u0001 \u0007 (8) tCO2 tCO2 \u0001MWh \u0007ref − \u0001MWh \u0007with capture The main assumptions for the economic analysis are shown below: • The baseline fuel cost (FC) for this analysis is $5.8 per million British thermal units ($/MMBtu) based on historical data from Ref. (EIA, 2020; Natural Gas Prices, 2020) (see Supplementary Figure S1). • For all cases, the CAPEX, FOM, VOM, and, TCO2 are obtained based on a previous work (Díaz-Herrera et al., 2020). The CAPEX and TCO2 were updated from 2017 to 2022 using the Chemical Engineering Plant Cost Index (CEPCI) (ToweringSkills, 2022). While, for the FOM and","cited_authors":"CAC ($ tCO2 ) \u0002 \u0001 \u0007 (8) tCO2 tCO2 \u0001MWh \u0007ref − \u0001MWh \u0007with capture The main assumptions for the economic analysis are shown below: • The baseline fuel cost (FC) for this analysis is $5.8 per million British thermal units ($/MMBtu) based on historical data from Ref. (EIA, 2020; Natural Gas Prices","cited_year":"2020","cited_title":"(see Supplementary Figure S1)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739793,"raw_reference":"VOM, we escalated costs from 2017 to current 2022 dollars according to the Mexican Producer Price Index (PPI) normalized to 60 in the year 2008 (INEGI, 2022). • The SCO2 assumed in this work is $8.1/tCO2 (updated from €2010 4/tCO2 (IEAGHG, 2011) using the CEPCI). • The economic life of the plant was assumed to be 30 years (SENER, 2018a; SENER, 2018b) with a capacity factor (CF) equal to 85%. Frontiers in Energy Research frontiersin.org Díaz-Herrera et al. 10.3389/fenrg.2022.987166","cited_authors":"VOM, we escalated costs from 2017 to current 2022 dollars according to the Mexican Producer Price Index (PPI) normalized to 60 in the year 2008 (INEGI","cited_year":"2022","cited_title":"• The SCO2 assumed in this work is $8.1/tCO2 (updated from €2010 4/tCO2 (IEAGHG, 2011) using the CEPCI)","cited_venue":null,"cited_doi":"10.3389/fenrg.2022.987166","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739794,"raw_reference":"Bolland, O., and Undrum, H. (2003). A novel methodology for comparing CO2 capture options for natural gas-ﬁred combined cycle plants. Adv. Environ. Res. 7 (4), 901–911. doi:10.1016/s1093-0191(02)00085-0","cited_authors":"Bolland, O., and Undrum, H","cited_year":"2003","cited_title":"A novel methodology for comparing CO2 capture options for natural gas-ﬁred combined cycle plants","cited_venue":null,"cited_doi":"10.1016/s1093-0191(02)00085-0","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739795,"raw_reference":"Feron, P., Cousins, A., Jiang, K., Zhai, R., Shwe Hla, S., Thiruvenkatachari, R., et al. (2019). Towards zero emissions from fossil fuel power stations. Int. J. Greenh. Gas Control 87, 188–202. doi:10.1016/j.ijggc.2019.05.018","cited_authors":"Feron, P., Cousins, A., Jiang, K., Zhai, R., Shwe Hla, S., Thiruvenkatachari, R., et al","cited_year":"2019","cited_title":"Towards zero emissions from fossil fuel power stations","cited_venue":null,"cited_doi":"10.1016/j.ijggc.2019.05.018","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739796,"raw_reference":"Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., et al. (2018). Carbon capture and storage (CCS): The way forward. Energy Environ. Sci. 11 (5), 1062–1176. doi:10.1039/c7ee02342a","cited_authors":"Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., et al","cited_year":"2018","cited_title":"Carbon capture and storage (CCS): The way forward","cited_venue":null,"cited_doi":"10.1039/c7ee02342a","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739797,"raw_reference":"D. (2008). Advances in CO2 capture technology—the U.S. Department of energy’s carbon sequestration program. Int. J. Greenh. Gas Control 2 (1), 9–20. doi:10.1016/s17505836(07)00094-1","cited_authors":"D","cited_year":"2008","cited_title":"Advances in CO2 capture technology—the U.S. Department of energy’s carbon sequestration program","cited_venue":null,"cited_doi":"10.1016/s17505836(07)00094-1","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739798,"raw_reference":"CFE (2022). CFE trabaja en proyecto de hidrógeno verde para minimizar dependencia de gas natural. Comisión Federal de Electricidad. Available at: https://app.cfe.mx/Aplicaciones/OTROS/Boletines/boletin?i=2442.","cited_authors":"CFE","cited_year":"2022","cited_title":"CFE trabaja en proyecto de hidrógeno verde para minimizar dependencia de gas natural","cited_venue":null,"cited_doi":null,"cited_url":"https://app.cfe.mx/Aplicaciones/OTROS/Boletines/boletin?i=2442","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739799,"raw_reference":"Finney, K. N., Akram, M., Diego, M. E., Yang, X., and Pourkashanian, M. (2019). “Chapter 2 - carbon capture technologies,” in Bioenergy with carbon capture and storage. Editors J. C. Magalhães Pires and A. L. D. Cunha Gonçalves (Academic Press), 15–45. Díaz-Herrera, P. R., Alcaraz-Calderon, A. M., Gonzalez-Diaz, M. O., and","cited_authors":"Finney, K. N., Akram, M., Diego, M. E., Yang, X., and Pourkashanian, M","cited_year":"2019","cited_title":"Chapter 2 - carbon capture technologies","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739800,"raw_reference":"Gonzalez-Diaz, A. (2020). Capture level design for a natural gas combined cycle with post-combustion CO2 capture using novel conﬁgurations. Energy 193, 116769. doi:10.1016/j.energy.2019.116769 Forbes (2022). Forbes de la iniciativa de reforma eléctrica: Cancelación de contratos y CFE como rector. Available from: https://www.forbes.com.mx/ negocios-guia-forbes-reforma-electrica-cancelacion-de-contratos-cfe-comorector/#:~:text=En%20este%20%E2%80%9Cnuevo%20sistema%20el%C3% A9ctrico,la%20energ%C3%ADa%20limpia%20del%20pa%C3%ADs. Díaz-Herrera, P. R., Ascanio, G., Romero-Martinez, A., Alcaraz-Calderon, A. M., and Gonzalez-Diaz, A. (2021). Theoretical comparison between post-combustion carbon capture technology and the use of blue and green H2 in existing natural gas combined cycles as CO2 mitigation strategies: A study under the context of mexican clean energy regulation. Int. J. Hydrogen Energy 46 (2), 2729–2754. doi:10.1016/j. ijhydene.2020.10.076","cited_authors":"Gonzalez-Diaz, A","cited_year":"2020","cited_title":"Capture level design for a natural gas combined cycle with post-combustion CO2 capture using novel conﬁgurations","cited_venue":null,"cited_doi":"10.1016/j.energy.2019.116769","cited_url":"https://www.forbes.com.mx/","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739801,"raw_reference":"S. (2011). Assessment of the technology readiness of post-combustion CO2 capture technologies. Energy Procedia 4, 1791–1796. doi:10.1016/j.egypro.2011.02.055","cited_authors":"S","cited_year":"2011","cited_title":"Assessment of the technology readiness of post-combustion CO2 capture technologies","cited_venue":null,"cited_doi":"10.1016/j.egypro.2011.02.055","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739802,"raw_reference":"DOE/NETL (2010). Bituminous Coal and Natural Gas to Electricity, Vol. 1.Cost Perform. Baseline Fossil Energy Plants Revision 2 (No. DOE/NETL-2010/1397).","cited_authors":"DOE/NETL","cited_year":"2010","cited_title":"Bituminous Coal and Natural Gas to Electricity, Vol","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739803,"raw_reference":"GCCSI (2020). The US section 45Q tax credit for carbon oxide sequestration: An update. Global CCS Institute. Available at: https://www.globalccsinstitute.com/ wpcontent/uploads/2020/04/45Q_Brief_in_template_LLB.pdf.","cited_authors":"GCCSI","cited_year":"2020","cited_title":"The US section 45Q tax credit for carbon oxide sequestration: An update","cited_venue":null,"cited_doi":null,"cited_url":"https://www.globalccsinstitute.com/","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739804,"raw_reference":"DOF (2014). LINEAMIENTOS que establecen los criterios para el otorgamiento de Certiﬁcados de Energías Limpias y los requisitos para su adquisición. Available from: https://dof.gob.mx/nota_detalle.php?codigo=5366674&fecha=31/10/ 2014#gsc.tab=0. Government of Canada (2021). Budget 2021: Part 2 - Creating Jobs and Growth. Available from: https://www.budget.gc.ca/2021/report-rapport/p2-en.html.","cited_authors":"DOF","cited_year":"2014","cited_title":"LINEAMIENTOS que establecen los criterios para el otorgamiento de Certiﬁcados de Energías Limpias y los requisitos para su adquisición","cited_venue":null,"cited_doi":null,"cited_url":"https://dof.gob.mx/nota_detalle.php?codigo=5366674&fecha=31/10/","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739805,"raw_reference":"J. (2009). Optimization of carbon capture percentage for technical and economic impact of near-term CCS implementation at coal-ﬁred power plants. Energy Procedia 1 (1), 4135–4142. doi:10.1016/j.egypro.2009.02.222","cited_authors":"J","cited_year":"2009","cited_title":"Optimization of carbon capture percentage for technical and economic impact of near-term CCS implementation at coal-ﬁred power plants","cited_venue":null,"cited_doi":"10.1016/j.egypro.2009.02.222","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739806,"raw_reference":"EIA (2020). U.S. Natural gas imports by pipeline from Mexico. Available from: https://www.eia.gov/dnav/ng/ng_move_poe2_dcu_NUS-NMX_a.htm. Frontiers in Energy Research frontiersin.org Díaz-Herrera et al. 10.3389/fenrg.2022.987166","cited_authors":"EIA","cited_year":"2020","cited_title":"U.S. Natural gas imports by pipeline from Mexico","cited_venue":null,"cited_doi":"10.3389/fenrg.2022.987166","cited_url":"https://www.eia.gov/dnav/ng/ng_move_poe2_dcu_NUS-NMX_a.htm","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739807,"raw_reference":"J. (2011). Economic and energetic analysis of capturing CO2 from ambient air. Proc. Natl. Acad. Sci. U. S. A. 108 (51), 20428–20433. doi:10.1073/pnas.1012253108","cited_authors":"J","cited_year":"2011","cited_title":"Economic and energetic analysis of capturing CO2 from ambient air","cited_venue":null,"cited_doi":"10.1073/pnas.1012253108","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739808,"raw_reference":"Pan, M., Aziz, F., Li, B., Perry, S., Zhang, N., Bulatov, I., et al. (2016). Application of optimal design methodologies in retroﬁtting natural gas combined cycle power plants with CO2 capture. Appl. Energy 161, 695–706. doi:10.1016/j.apenergy.2015.03.035","cited_authors":"Pan, M., Aziz, F., Li, B., Perry, S., Zhang, N., Bulatov, I., et al","cited_year":"2016","cited_title":"Application of optimal design methodologies in retroﬁtting natural gas combined cycle power plants with CO2 capture","cited_venue":null,"cited_doi":"10.1016/j.apenergy.2015.03.035","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739809,"raw_reference":"IEAGHG (2006). Estimating future trends in the cost of CO2 capture technologies.","cited_authors":"IEAGHG","cited_year":"2006","cited_title":"Estimating future trends in the cost of CO2 capture technologies","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739810,"raw_reference":"Roussanaly, S., Rubin, E., van der Spek, M., Booras, G., Berghout, N., Fout, T., et al. (2021). Towards improved guidelines for cost evaluation of carbon capture and storage. Available from: https://netl.doe.gov/energy-analysis/details?id= 7d80d478-b68b-4598-a934-78cffbb3ddf3.","cited_authors":"Roussanaly, S., Rubin, E., van der Spek, M., Booras, G., Berghout, N., Fout, T., et al","cited_year":"2021","cited_title":"Towards improved guidelines for cost evaluation of carbon capture and storage","cited_venue":null,"cited_doi":null,"cited_url":"https://netl.doe.gov/energy-analysis/details?id=","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739811,"raw_reference":"IEAGHG (2011). The cost of CO2 storage: Post-demonstration CCS in the EU. Available from: https://www.globalccsinstitute.com/archive/hub/publications/ 119816/costs-co2-storage-post-demonstration-ccs-eu.pdf.","cited_authors":"IEAGHG","cited_year":"2011","cited_title":"The cost of CO2 storage: Post-demonstration CCS in the EU. Available from: https://www.globalccsinstitute.com/archive/hub/publications/ 119816/costs-co2-storage-post-demonstration-ccs-eu.pdf","cited_venue":null,"cited_doi":null,"cited_url":"https://www.globalccsinstitute.com/archive/hub/publications/","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739812,"raw_reference":"J. (2015). The cost of CO2 capture and storage. Int. J. Greenh. Gas Control 40, 378–400. doi:10.1016/j.ijggc.2015.05.018","cited_authors":"J","cited_year":"2015","cited_title":"The cost of CO2 capture and storage","cited_venue":null,"cited_doi":"10.1016/j.ijggc.2015.05.018","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739813,"raw_reference":"INECC (2015). Inventario nacional de Emisiones de Gases de Efecto invernadero. Instituto Nacional de Ecología y Cambio Climático. Available at: https://www.gob. mx/inecc/acciones-y-programas/inventario-nacional-de-emisionesde-gases-ycompuestos-de-efecto-invernadero.","cited_authors":"INECC","cited_year":"2015","cited_title":"Inventario nacional de Emisiones de Gases de Efecto invernadero","cited_venue":null,"cited_doi":null,"cited_url":"https://www.gob","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739814,"raw_reference":"Rubin, E. S., Yeh, S., Antes, M., Berkenpas, M., and Davison, J. (2007). Use of experience curves to estimate the future cost of power plants with CO2 capture. Int. J. Greenh. Gas Control 1 (2), 188–197. doi:10.1016/s1750-5836(07)00016-3","cited_authors":"Rubin, E. S., Yeh, S., Antes, M., Berkenpas, M., and Davison, J","cited_year":"2007","cited_title":"Use of experience curves to estimate the future cost of power plants with CO2 capture","cited_venue":null,"cited_doi":"10.1016/s1750-5836(07)00016-3","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739815,"raw_reference":"INEGI (2022). Mexican producer price index. Available from: https://en.www. inegi.org.mx/temas/inpp/.","cited_authors":"INEGI","cited_year":"2022","cited_title":"Mexican producer price index","cited_venue":null,"cited_doi":null,"cited_url":"https://en.www","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739816,"raw_reference":"Saleh, A., Sanchez Fernandez, E., Maroto-Valer, M. M., and Garcia, S. (2019). Conceptual design for integrating lithium-based carbon capture looping systems into natural gas combined cycle power plants. Ind. Eng. Chem. Res. 58 (32), 14975–14990. doi:10.1021/acs.iecr.9b00752","cited_authors":"Saleh, A., Sanchez Fernandez, E., Maroto-Valer, M. M., and Garcia, S","cited_year":"2019","cited_title":"Conceptual design for integrating lithium-based carbon capture looping systems into natural gas combined cycle power plants","cited_venue":null,"cited_doi":"10.1021/acs.iecr.9b00752","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739817,"raw_reference":"Irlam, L. (2017). Global costs of carbon capture and storage: 2017 update. Glob.","cited_authors":"Irlam, L","cited_year":"2017","cited_title":"Global costs of carbon capture and storage: 2017 update","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739818,"raw_reference":"Vlugt, T. (2014). Thermodynamic assessment of amine based CO2 capture technologies in power plants based on European Benchmarking Task Force methodology. Fuel 129, 318–329. doi:10.1016/j.fuel.2014.03.042","cited_authors":"Vlugt, T","cited_year":"2014","cited_title":"Thermodynamic assessment of amine based CO2 capture technologies in power plants based on European Benchmarking Task Force methodology","cited_venue":null,"cited_doi":"10.1016/j.fuel.2014.03.042","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739819,"raw_reference":"F. (2021). The tax credit for carbon sequestration (section 45Q). Congr. Res. Serv., 3.","cited_authors":"F","cited_year":"2021","cited_title":"The tax credit for carbon sequestration (section 45Q)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739820,"raw_reference":"Lambert, T., Hoadley, A., and Hooper, B. (2014). Process integration of solar thermal energy with natural gas combined cycle carbon capture. Energy 74, 248–253. doi:10.1016/j.energy.2014.06.038","cited_authors":"Lambert, T., Hoadley, A., and Hooper, B","cited_year":"2014","cited_title":"Process integration of solar thermal energy with natural gas combined cycle carbon capture","cited_venue":null,"cited_doi":"10.1016/j.energy.2014.06.038","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739821,"raw_reference":"SENER (2018a). Programa de Desarrollo del Sistema Eléctrico Nacional (PRODESEN) 2018-2032. Secretaría de Energía. Available at: https://www.gob. mx/cms/uploads/attachment/ﬁle/331770/PRODESEN-2018-2032-deﬁnitiva.pdf.","cited_authors":"SENER","cited_year":"2018a","cited_title":"Programa de Desarrollo del Sistema Eléctrico Nacional (PRODESEN) 2018-2032","cited_venue":null,"cited_doi":null,"cited_url":"https://www.gob","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739822,"raw_reference":"Li, H., Ditaranto, M., and Berstad, D. (2011). Technologies for increasing CO2 concentration in exhaust gas from natural gas-ﬁred power production with post-combustion, amine-based CO2 capture. Energy 36 (2), 1124–1133. doi:10. 1016/j.energy.2010.11.037","cited_authors":"Li, H., Ditaranto, M., and Berstad, D","cited_year":"2011","cited_title":"Technologies for increasing CO2 concentration in exhaust gas from natural gas-ﬁred power production with post-combustion, amine-based CO2 capture","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739823,"raw_reference":"SENER (2018b). Tabla de permisos de generación e importación de energía eléctrica administrados al 30 de abril de 2018. Available from: https://www.gob.mx/ cms/uploads/attachment/ﬁle/323655/INFO_PAGINA_2018-04-30_-_ 1TablaPermisos.pdf.","cited_authors":"SENER","cited_year":"2018b","cited_title":"Tabla de permisos de generación e importación de energía eléctrica administrados al 30 de abril de 2018","cited_venue":null,"cited_doi":null,"cited_url":"https://www.gob.mx/","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739824,"raw_reference":"E. (2012). Feasibility of integrating solar energy into a power plant with amine-based chemical absorption for CO2 capture. Int. J. Greenh. Gas Control 9, 272–280. doi:10.1016/j.ijggc.2012.04.005","cited_authors":"E","cited_year":"2012","cited_title":"Feasibility of integrating solar energy into a power plant with amine-based chemical absorption for CO2 capture","cited_venue":null,"cited_doi":"10.1016/j.ijggc.2012.04.005","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739825,"raw_reference":"SENER (2019). Programa de Desarrollo del Sistema Eléctrico Nacional (PRODESEN) 2019-2033. Secretaría de Energía. Available at: https://www.gob. mx/sener/articulos/prodesen-2019-2033-221654.","cited_authors":"SENER","cited_year":"2019","cited_title":"Programa de Desarrollo del Sistema Eléctrico Nacional (PRODESEN) 2019-2033","cited_venue":null,"cited_doi":null,"cited_url":"https://www.gob","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739826,"raw_reference":"Lindqvist, K., Jordal, K., Haugen, G., Hoff, K. A., and Anantharaman, R. (2014). Integration aspects of reactive absorption for post-combustion CO2 capture from","cited_authors":"Lindqvist, K., Jordal, K., Haugen, G., Hoff, K. A., and Anantharaman, R","cited_year":"2014","cited_title":"Integration aspects of reactive absorption for post-combustion CO2 capture from","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739827,"raw_reference":"NGCC (natural gas combined cycle) power plants. Energy 78, 758–767. doi:10.1016/ j.energy.2014.10.070","cited_authors":"NGCC (natural gas combined cycle) power plants. Energy 78, 758–767. doi:10.1016/ j.energy","cited_year":"2014","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739828,"raw_reference":"SENER (2021). Programa de Desarrollo del Sistema Eléctrico Nacional (PRODESEN) 2020–2024. Available from: https://www.gob.mx/sener/articulos/prodesen-2020-2034.","cited_authors":"SENER","cited_year":"2021","cited_title":"Programa de Desarrollo del Sistema Eléctrico Nacional (PRODESEN) 2020–2024","cited_venue":null,"cited_doi":null,"cited_url":"https://www.gob.mx/sener/articulos/prodesen-2020-2034","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739829,"raw_reference":"Shirmohammadi, R., Aslani, A., and Ghasempour, R. (2020). Challenges of carbon capture technologies deployment in developing countries. Sustain. Energy Technol. Assessments 42, 100837. doi:10.1016/j.seta.2020.100837","cited_authors":"Shirmohammadi, R., Aslani, A., and Ghasempour, R","cited_year":"2020","cited_title":"Challenges of carbon capture technologies deployment in developing countries","cited_venue":null,"cited_doi":"10.1016/j.seta.2020.100837","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739830,"raw_reference":"Liu, J. (2020). Investigation into an energy-saving mechanism for advanced stripper conﬁgurations in post-combustion carbon capture. J. Taiwan Inst. Chem. Eng. 108, 43–54. doi:10.1016/j.jtice.2019.12.012","cited_authors":"Liu, J","cited_year":"2020","cited_title":"Investigation into an energy-saving mechanism for advanced stripper conﬁgurations in post-combustion carbon capture","cited_venue":null,"cited_doi":"10.1016/j.jtice.2019.12.012","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739831,"raw_reference":"Liu, Y., Deng, S., Zhao, R., He, J., and Zhao, L. (2017). Energy-saving pathway exploration of CCS integrated with solar energy: A review of innovative concepts. Renew. Sustain. Energy Rev. 77, 652–669. doi:10.1016/j.rser.2017.04.031","cited_authors":"Liu, Y., Deng, S., Zhao, R., He, J., and Zhao, L","cited_year":"2017","cited_title":"Energy-saving pathway exploration of CCS integrated with solar energy: A review of innovative concepts","cited_venue":null,"cited_doi":"10.1016/j.rser.2017.04.031","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739832,"raw_reference":"Petrakopoulou, F. (2021). Techno-economic assessment and optimization of a solar-assisted industrial post-combustion CO2 capture and utilization plant. Energy Rep. 7, 7390–7404. doi:10.1016/j.egyr.2021.10.091","cited_authors":"Petrakopoulou, F","cited_year":"2021","cited_title":"Techno-economic assessment and optimization of a solar-assisted industrial post-combustion CO2 capture and utilization plant","cited_venue":null,"cited_doi":"10.1016/j.egyr.2021.10.091","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739833,"raw_reference":"McDonald, A., and Schrattenholzer, L. (2001). Learning rates for energy technologies. Energy Policy 29 (4), 255–261. doi:10.1016/s0301-4215(00) 00122-1 ToweringSkills (2022). Cost indices. Available from: https://www.toweringskills. com/ﬁnancial-analysis/cost-indices/.","cited_authors":"McDonald, A., and Schrattenholzer, L","cited_year":"2001","cited_title":"Learning rates for energy technologies","cited_venue":null,"cited_doi":"10.1016/s0301-4215(00","cited_url":"https://www.toweringskills","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739834,"raw_reference":"Metz B, D. O., Coninck, H. D., Loos, M., and Meyer, L. (2005). Carbon dioxide capture and storage: IPCC special report, 431.","cited_authors":"Metz B, D. O., Coninck, H. D., Loos, M., and Meyer, L","cited_year":"2005","cited_title":"Carbon dioxide capture and storage: IPCC special report, 431","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739835,"raw_reference":"Vaccarelli, M., Carapellucci, R., and Giordano, L. (2014). Energy and economic analysis of the CO2 capture from ﬂue gas of combined cycle power plants. Energy Procedia 45, 1165–1174. doi:10.1016/j.egypro.2014.01.122","cited_authors":"Vaccarelli, M., Carapellucci, R., and Giordano, L","cited_year":"2014","cited_title":"Energy and economic analysis of the CO2 capture from ﬂue gas of combined cycle power plants","cited_venue":null,"cited_doi":"10.1016/j.egypro.2014.01.122","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739836,"raw_reference":"Muhammad, H. A., Sultan, H., Lee, B., Imran, M., Baek, I. H., Baik, Y. J., et al. (2020). Energy minimization of carbon capture and storage by means of a novel process conﬁguration. Energy Convers. Manag. 215, 112871. doi:10.1016/j.enconman.2020.112871","cited_authors":"Muhammad, H. A., Sultan, H., Lee, B., Imran, M., Baek, I. H., Baik, Y. J., et al","cited_year":"2020","cited_title":"Energy minimization of carbon capture and storage by means of a novel process conﬁguration","cited_venue":null,"cited_doi":"10.1016/j.enconman.2020.112871","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739837,"raw_reference":"Vega, F., Baena-Moreno, F., Gallego Fernandez, L. M., Portillo, E., Navarrete, B., and Zhang, Z. (2020). Current status of CO2 chemical absorption research applied to CCS: Towards full deployment at industrial scale. Appl. Energy 260, 114313. doi:10.1016/j.apenergy.2019.114313 Natural gas prices - historical chart. 2020 [cited 2020 2020-05-31 12:34:46]. Available from: https://www.macrotrends.net/2478/natural-gas-prices-historical-chart.","cited_authors":"Vega, F., Baena-Moreno, F., Gallego Fernandez, L. M., Portillo, E., Navarrete, B., and Zhang, Z","cited_year":"2020","cited_title":"Current status of CO2 chemical absorption research applied to CCS: Towards full deployment at industrial scale","cited_venue":null,"cited_doi":"10.1016/j.apenergy.2019.114313","cited_url":"https://www.macrotrends.net/2478/natural-gas-prices-historical-chart","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739838,"raw_reference":"Wang, F., Zhao, J., Li, H., Li, H., Zhao, L., and Yan, J. (2015). Experimental study of solar assisted post-combustion carbon capture. Energy Procedia 75, 2246–2252. doi:10.1016/j.egypro.2015.07.401","cited_authors":"Wang, F., Zhao, J., Li, H., Li, H., Zhao, L., and Yan, J","cited_year":"2015","cited_title":"Experimental study of solar assisted post-combustion carbon capture","cited_venue":null,"cited_doi":"10.1016/j.egypro.2015.07.401","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739839,"raw_reference":"NETL (2014). Technology learning curve (FOAK to NOAK), quality guidelines for energy system studies. Pittsburgh, PA: National Energy Technology Laboratory, U.S. Department of Energy.","cited_authors":"NETL","cited_year":"2014","cited_title":"Technology learning curve (FOAK to NOAK), quality guidelines for energy system studies","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739840,"raw_reference":"Wilcox, J. Carbon capture. 2012, Available at: https://www.springer.com/gp/ book/9781461422143.","cited_authors":"Wilcox, J. Carbon capture","cited_year":"2012","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"https://www.springer.com/gp/","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739841,"raw_reference":"Normann, F., Garðarsdottir, S. O., Skagestad, R., Mathisen, A., and Johnsson, F. (2017). Partial capture of carbon dioxide from industrial sources - a discussion on cost optimization and the CO2 capture rate. Energy Procedia 114, 113–121. doi:10. 1016/j.egypro.2017.03.1154","cited_authors":"Normann, F., Garðarsdottir, S. O., Skagestad, R., Mathisen, A., and Johnsson, F","cited_year":"2017","cited_title":"Partial capture of carbon dioxide from industrial sources - a discussion on cost optimization and the CO2 capture rate","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739842,"raw_reference":"Wilcox, J., Psarras, P. C., and Liguori, S. (2017). Assessment of reasonable opportunities for direct air capture. Environ. Res. Lett. 12 (6), 065001. doi:10. 1088/1748-9326/aa6de5","cited_authors":"Wilcox, J., Psarras, P. C., and Liguori, S","cited_year":"2017","cited_title":"Assessment of reasonable opportunities for direct air capture","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739843,"raw_reference":"Oh, S.-Y., Yun, S., and Kim, J.-K. (2018). Process integration and design for maximizing energy efﬁciency of a coal-ﬁred power plant integrated with aminebased CO2 capture process. Appl. Energy 216, 311–322. doi:10.1016/j.apenergy. 2018.02.100 Frontiers in Energy Research","cited_authors":"Oh, S.-Y., Yun, S., and Kim, J.-K","cited_year":"2018","cited_title":"Process integration and design for maximizing energy efﬁciency of a coal-ﬁred power plant integrated with aminebased CO2 capture process","cited_venue":null,"cited_doi":"10.1016/j.apenergy","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739844,"raw_reference":"Zhai, R., Liu, H., Wu, H., Yu, H., and Yang, Y. (2018). Analysis of integration of MEAbased CO2 capture and solar energy system for coal-based power plants based on thermo-economic structural theory. Energies 11 (5), 1284. doi:10.3390/en11051284 frontiersin.org Díaz-Herrera et al. 10.3389/fenrg.2022.987166 Nomenclature","cited_authors":"Zhai, R., Liu, H., Wu, H., Yu, H., and Yang, Y","cited_year":"2018","cited_title":"Analysis of integration of MEAbased CO2 capture and solar energy system for coal-based power plants based on thermo-economic structural theory","cited_venue":null,"cited_doi":"10.3390/en11051284","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739845,"raw_reference":"online at: https://www.frontiersin.org/articles/10.3389/fenrg.2022.","cited_authors":"online at: https://www.frontiersin.org/articles/10.3389/fenrg","cited_year":"2022","cited_title":null,"cited_venue":null,"cited_doi":"10.3389/fenrg.2022","cited_url":"https://www.frontiersin.org/articles/10.3389/fenrg.2022","ref_kind":"journal_article","section":"doi","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1739846,"raw_reference":"clean energy regulation. Int. J. Hydrogen Energy 46 (2), 2729–2754. doi:10.1016/j.","cited_authors":null,"cited_year":null,"cited_title":"clean energy regulation","cited_venue":null,"cited_doi":"10.1016/j","cited_url":null,"ref_kind":"journal_article","section":"doi","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}