NIOSH Manual of Analytical Methods (NMAM), 5th Edition, Section 2
Other documents for the same rulemaking (all, by stage)
References: 1,700 extracted, 0 linked to papers
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-82 of BA-115 Sampling and Characterization of Bioaerosols
Leland DS, Emanuel D [1995]. Laboratory diagnosis of viral infections of the lung. Semin Respir Infect 10(4):189-198.
Leland DS, Ginocchio CC [2007]. Role of cell culture for virus detection in the age of technology. Clin Microbiol Rev 20(1):49-78.
Lembke LL, Kniseley RN, van Nostrand RC, Hale MD [1981]. Precision of the all-glass impinger and the Andersen microbial impactor for air sampling in solid-waste handling facilities. Appl Environ Microbiol 42(2):222-225. Leopold SS [1988]. "Positive hole" statistical adjustment for a two-stage, 200-hole-per-stage Andersen air sampler. Am Ind Hyg Assoc J 49(2):A88-A90. Life Technologies [2014]. Real-time PCR handbook. Waltham, MA: Thermo Fisher Scientific, http://www.thermofisher.com/us/en/home/life-science/pcr/real-time-pcr/qpcreducation.html.
Lin X, Willeke K, Ulevicius V, Grinshpun SA [1997]. Effect of sampling time on the collection efficiency of all-glass impingers. Am Ind Hyg Assoc J 58(7):480-488.
Lin XJ, Reponen T, Willeke K, Wang Z, Grinshpun SA, Trunov M [2000]. Survival of airborne microorganisms during swirling aerosol collection. Aerosol Sci Technol 32(3):184-196.
ME, Thewlis RE, Posada JA, Redrow JB, Celik IB, Chen BT, Beezhold DH [2010a]. Distribution of airborne influenza virus and respiratory syncytial virus in an urgent care medical clinic. Clin Infect Dis 50(5):693-698.
Fisher MA, Khakoo R, Beezhold DH [2010b]. Measurements of airborne influenza virus in aerosol particles from human coughs. PLoS ONE 5(11):e15100.
Lioy PJ, Freeman NC, Millette JR [2002]. Dust: a metric for use in residential and building exposure assessment and source characterization. Environ Health Perspect 110(10):969-983.
Liu BYH, Pui DYH, Rubow KL, Szymanski WW [1985]. Electrostatic effects in aerosol sampling and filtration. Aerosol Sci Technol 4(3):249-268.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-83 of BA-115 Sampling and Characterization of Bioaerosols
Lowen AC, Mubareka S, Steel J, Palese P [2007]. Influenza virus transmission is dependent on relative humidity and temperature. PLoS Pathog 3(10):1470-1476.
Lowen AC, Steel J, Mubareka S, Palese P [2008]. High temperature (30 degrees C) blocks aerosol but not contact transmission of influenza virus. J Virol 82(11):5650-5652. Macher JM [1989]. Positive-hole correction of multiple-jet impactors for collecting viable microorganisms. Am Ind Hyg Assoc J 50(11):561-568. Macher JM [1999]. Bioaerosols: assessment and control. Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
Macher JM, Chatigny MA, Burge HA [1995]. Sampling airborne microorganisms and aeroallergens. In: Cohen BS, Hering SV, eds. Air sampling instruments for evaluation of atmospheric contaminants. Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
Macher JM, First MW [1984]. Personal air samplers for measuring occupational exposures to biological hazards. Am Ind Hyg Assoc J 45(2):76-83.
Macher JM, Hansson HC [1987]. Personal size-separating impactor for sampling microbiological aerosols. Am Ind Hyg Assoc J 48(7):652-655.
Madeley CR, Peiris JS [2002]. Methods in virus diagnosis: immunofluorescence revisited. J Clin Virol 25(2):121-134.
Madelin TM, Johnson HE [1992]. Fungal and actinomycete spore aerosols measured at different humidities with an aerodynamic particle sizer. J Appl Bacteriol 72(5):400-409. Mahony JB [2008]. Detection of respiratory viruses by molecular methods. Clin Microbiol Rev 21(4):716-747.
Mainelis G, Gorny RL, Reponen T, Trunov M, Grinshpun SA, Baron P, Yadav J, Willeke K [2002]. Effect of electrical charges and fields on injury and viability of airborne bacteria. Biotechnol Bioeng 79(2):229-241.
Marple VA, Olson BA [2011]. Sampling and measurement using inertial, gravitational, centrifugal, and thermal techniques. In: Kulkarni P, Baron PA, Willeke K, eds. Aerosol measurement: principles, techniques, and applications. Hoboken, NJ: John Wiley & Sons.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-84 of BA-115 Sampling and Characterization of Bioaerosols
Marple VA, Willeke K [1976]. Inertial impactors: theory, design and use. In: Liu BYH, ed. Fine particles: aerosol generation, measurement, sampling and analysis. New York: Academic Press.
Martin E, Dziurowitz N, Jackel U, Schafer J [2015]. Detection of airborne bacteria in a duck production facility with two different personal air sampling devices for an exposure assessment. J Occup Environ Hyg 12(2):77-86.
Martyny JW, Martinez KF, Morey PR [1999]. Source Sampling. In: Macher J, ed. Bioaerosols: assessment and control. Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
Masclaux FG, Hotz P, Gashi D, Savova-Bianchi D, Oppliger A [2014]. Assessment of airborne virus contamination in wastewater treatment plants. Environ Res 133:260-265. May KR [1966]. Multistage liquid impinger. Bacteriol Rev 30(3):559-570.
May KR, Harper GJ [1957]. The efficiency of various liquid impinger samplers in bacterial aerosols. Br J Ind Med 14(4):287-297.
McDevitt JJ, Koutrakis P, Ferguson ST, Wolfson JM, Fabian MP, Martins M, Pantelic J, Milton DK [2013]. Development and performance evaluation of an exhaled-breath bioaerosol collector for influenza virus. Aerosol Sci Technol 47(4):444-451.
Meadow JF, Altrichter AE, Bateman AC, Stenson J, Brown GZ, Green JL, Bohannan BJ [2015]. Humans differ in their personal microbial cloud. PeerJ 3:e1258.
Meklin T, Reponen T, Toivola M, Koponen V, Husman T, Hyvarinen A, Nevalainen A [2002]. Size distributions of airborne microbes in moisture-damaged and reference school buildings of two construction types. Atmos Environ 36(39-40):6031-6039.
Mendell MJ, Mirer AG, Cheung K, Tong M, Douwes J [2011]. Respiratory and allergic health effects of dampness, mold, and dampness‑ related agents: a review of the epidemiologic evidence. Environ Health Perspect 119:748-756.
Mikhailov E, Vlasenko S, Niessner R, Poschl U [2004]. Interaction of aerosol particles composed of protein and salts with water vapor: hygroscopic growth and microstructural rearrangement. Atmos Chem Phys 4(2):323-350.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-85 of BA-115 Sampling and Characterization of Bioaerosols
Milton DK, Fabian MP, Cowling BJ, Grantham ML, McDevitt JJ [2013]. Influenza virus aerosols in human exhaled breath: particle size, culturability, and effect of surgical masks. PLoS Pathog 9(3):e1003205.
Milton DK, Gere RJ, Feldman HA, Greaves IA [1990]. Endotoxin measurement: aerosol sampling and application of a new Limulus method. Am Ind Hyg Assoc J 51(6):331-337.
Mitakakis TZ, Barnes C, Tovey ER [2001]. Spore germination increases allergen release from Alternaria. J Allergy Clin Immunol 107(2):388-390.
Mitakakis TZ, O'Meara TJ, Tovey ER [2003]. The effect of sunlight on allergen release from spores of the fungus Alternaria. Grana 42(1):43-46.
Mitakakis TZ, Tovey ER, Xuan W, Marks GB [2000]. Personal exposure to allergenic pollen and mould spores in inland New South Wales, Australia. Clin Exp Allergy 30(12):1733-1739.
Moore G, Griffith C [2007]. Problems associated with traditional hygiene swabbing: the need for in-house standardization. J Appl Microbiol 103(4):1090-1103.
Morey P, Otten J, Burge H, Chatigny M, Feeley J, LaForce FM, Peterson K [1986]. Airborne viable microorganisms in office environments: sampling protocol and analytical procedures. Appl Ind Hyg 1:R19-R23. Morey PR [2007]. Microbiological sampling strategies in indoor environments. In: Sampling and analysis of indoor microorganisms. Hoboken, NJ: John Wiley & Sons, Inc.
Murray BK, Ohmine S, Tomer DP, Jensen KJ, Johnson FB, Kirsi JJ, Robison RA, O'Neill KL [2008]. Virion disruption by ozone-mediated reactive oxygen species. J Virol Methods 153(1):74-77. Nardell EA [2016]. Indoor environmental control of tuberculosis and other airborne infections. Indoor Air 26(1):79-87. Nazaroff WW [2016]. Indoor bioaerosol dynamics. Indoor Air 26(1):61-78. Nevalainen A [1989]. Bacterial aerosols in indoor air. Thesis. Helsinki, Finland: National Public Health Institute.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-86 of BA-115 Sampling and Characterization of Bioaerosols
Nevalainen A, Taubel M, Hyvarinen A [2015]. Indoor fungi: companions and contaminants. Indoor Air 25(2):125-156.
Nicas M, Nazaroff WW, Hubbard A [2005]. Toward understanding the risk of secondary airborne infection: emission of respirable pathogens. J Occup Environ Hyg 2(3):143-154.
NIOSH [2003a]. Aerosol sampling: minimizing particle loss from cassette bypass leakage. By
Baron PA. In: Schlecht PC, O’Connor PF, eds. NIOSH Manual of Analytical Methods, 4th edition. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2003-154, http://www.cdc.gov/niosh/nmam.
NIOSH [2003b]. Method 0800 Bioaerosol sampling (indoor air). In: Schlecht PC, O’Connor
PF, eds. NIOSH Manual of Analytical Methods, 4th edition. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2003-154, http://www.cdc.gov/niosh/nmam.
NIOSH [2003c]. Method 0600 Particulates not otherwise regulated, respirable. In: Schlecht
NIOSH [2003d]. Method 2549 Volatile organic compounds (screening). In: Schlecht PC,
NIOSH [2003e]. NIOSH Manual of Analytical Methods, 4th edition. Schlecht PC, O’Connor