Policy Replication

NIOSH Manual of Analytical Methods (NMAM), 5th Edition, Section 2

Docket document2024-12-18 · EPA · publication · EPA-HQ-OPPT-2020-0720-0319
RIN 2070-AK84 · Docket EPA-HQ-OPPT-2020-0720

Other documents for the same rulemaking (all, by stage)

2021-07-16 Docket documentDiscussion of Risk Management under TSCA with the American College of Occupational and Environmental Medicine (ACOEM). February 1, 2021
2021-07-16 Docket documentMeeting with National Cleaners Association on Risk Management under TSCA Section 6 and Perchloroethylene (PCE). January 28, 2021
2021-07-16 Docket documentMeeting with Plasma Technology Incorporated on Risk Management under TSCA Section 6 and Perchloroethylene (PCE), January 26, 2021
2021-07-16 Docket documentDiscussion of Risk Management under TSCA at Council Meeting on Government Affairs with the American College of Occupational and Environmental Medicine (ACOEM), January 7, 2021
2021-07-16 Docket documentPublic Webinar on Perchloroethylene: Risk Evaluation and Risk Management under TSCA Section 6. January 14, 2021.
2021-07-16 Docket documentSmall Business Administration Small Business Environmental Roundtable: Risk Evaluation and Risk Management under TSCA Section 6 for Perchloroethylene, January 15, 2021
2021-07-16 Docket documentMemo Opening Docket for Public Access
2021-10-05 Docket documentMeeting with Spirit AeroSystems on Risk Management under TSCA Section 6 and Perchloroethylene (PCE). March 11, 2021
2021-10-05 Docket documentMeeting with IB Industries and SafeChem on Risk Management under TSCA Section 6 for Perchloroethylene. March 11, 2021
2021-10-05 Docket documentMeeting with The Chemours Company on Risk Management under TSCA Section 6 and Perchloroethylene. February 23, 2021
2021-10-05 Docket documentMeeting with Halogenated Solvents Industry Alliance on Risk Management under TSCA Section 6, n-Methylpyrrolidone, Trichloroethylene, and Perchloroethylene. March 3, 2021
2021-10-05 Docket documentMeeting with Household & Commercial Products Association on Risk Management under TSCA Section 6, n-Methylpyrrolidone, Trichloroethylene, Perchloroethylene, and C.I. Pigment Violet 29. March 4, 2021
2021-10-05 Docket documentMeeting with Chem Logic and Reliance Specialty Products on Risk Management under TSCA Section 6, 1-Bromopropane, Trichloroethylene, and Perchloroethylene. February 25, 2021
2021-10-05 Docket documentRisk Evaluation and Risk Management under TSCA Section 6 at Kansas State University Small Business Environmental Assistance Program Meeting – Dry Cleaning Focus. March 2, 2021
2021-10-05 Docket documentMeeting with Auto Innovators on Risk Management and Risk Evaluations under TSCA Section 6, n-Methylpyrrolidone, Trichloroethylene, Perchloroethylene, and C.I. Pigment Violet 29. March 1, 2021
2021-10-05 Docket documentMeeting with King County's Hazardous Waste Management Program on Risk Management under TSCA Section 6 and Perchloroethylene. March 18, 2021
2021-10-05 Docket documentMeeting with CRC Industries on Risk Management under TSCA Section 6 for Perchloroethylene. March 16, 2021
2021-10-12 Docket documentMeeting with Honeywell on Risk Management under TSCA Section 6 and Perchloroethylene (PCE). March 25, 2021
2022-02-14 Docket documentMeeting with Baron-Blakeslee on Risk Management under TSCA Section 6 for Trichloroethylene, Perchloroethylene, 1-Bromopropane, and Methylene Chloride. April 1, 2021
2022-02-14 Docket documentMeeting with Toxics Use Reduction Institute (TURI) on Risk Management under TSCA Section 6 for Trichloroethylene, Perchloroethylene, Methylene Chloride, 1-Bromopropane, and n-Methylpyrrolidone. April 26, 2021
2022-02-14 Docket documentMeeting with Ecoclean on Risk Management under TSCA Section 6 for Trichloroethylene (TCE) and Perchloroethylene (PCE). April 14, 2021
2022-02-14 Docket documentMeeting with Parts Cleaning Technologies on Risk Management under TSCA Section 6 for Trichloroethylene, Perchloroethylene, and 1-Bromopropane. March 31, 2021
2022-05-19 Docket documentExisting Chemical Exposure Limit (ECEL) for Occupational Use of Perchloroethylene
2023-06-16 Federal RegisterPerchloroethylene (PCE); Regulation Under the Toxic Substances Control Act (TSCA)
2023-06-16 Regulatory impact analysisBeryllium Final Economic Analysis (FEA) and Final Regulatory Flexibility Analysis. OSHA-H005C-2006-0
2023-06-16 Regulatory impact analysisTechnical Guidance for Assessing Environmental Justice in Regulatory Analysis
2023-06-16 Regulatory impact analysisEconomic Analysis of Proposed TSCA Section 6 Action on Trichloroethylene in Dry Cleaning Spot Removers and Aerosol Degreasers
2023-06-16 Regulatory impact analysisInitial Regulatory Flexibility Analysis for Perchloroethylene; Regulation of Perchloroethylene under TSCA §6(a) Proposed Rule; RIN 2070-AK84
2023-06-16 Regulatory impact analysisEconomic Analysis of Regulation of Methylene Chloride Paint and Coating Remover under TSCA Section 6(a)
2023-06-16 Regulatory impact analysisFinal Economic Analysis and Final Regulatory Flexibility Analysis. Supporting Document for the Final Rule for Occupational Exposure to Respirable Crystalline Silica
2023-06-16 Regulatory impact analysisEconomic Analysis of the Proposed Regulation of Perchloroethylene Under TSCA Section 6(a)
2023-06-16 Regulatory impact analysisEstimated Costs for Respirator PPE for TSCA Risk Management Economic Analyses
2023-06-16 Regulatory impact analysisFinal Economic and Regulatory Flexibility Analysis for OSHA Standard for Occupational Exposure to Methylene Chloride
2023-06-16 Regulatory impact analysisSupport for an economic analysis of a proposed OSHA standard for assigned protection facctors for respirators
2023-06-16 Regulatory impact analysisEconomic Analysis of the Formaldehyde Standards for Composite Wood Products Act Implementing Regulations Proposed Rule
2023-06-16 Regulatory impact analysisEconomic Analysis of the Proposed Regulation of Methylene Chloride Under TSCA Section 6(a)
2023-06-16 Docket documentGuidelines for Preparing Economic Analyses
2023-06-16 Docket documentDocumentation of EO 12866 Review; Perchloroethylene (PCE); Regulation under the Toxic Substances Control Act (TSCA); Proposed Rule (RIN 2070-AK84)
2023-06-16 Docket documentMeeting with Chemours on Risk Management and Supplemental Screening-Level Fenceline Analysis under TSCA Section 6 for Perchloroethylene and Carbon Tetrachloride. September 27, 2021
2023-06-16 Docket documentKnown Uses of Perchloroethylene
2023-06-16 Docket documentRespirator Usage in Private Sector Firms, 2001
2023-06-16 Docket documentSpotting Chemicals: Alternatives to Perchloroethylene and Trichloroethylene in the Textile Cleaning Industry
2023-06-16 Docket documentHierarchy of Controls
2023-06-16 Docket documentRisk Evaluation for Perchloroethylene (Ethylene, 1,1,2,2-Tetrachloro) Systematic Review Supplemental File: Data Quality Evaluation of Environmental Releases and Occupational Exposure
2023-06-16 Docket documentRespiratory Protection Standard
2023-06-16 Docket documentRisk Management for Perchloroethylene Supplemental File: Occupational Risk Calculator
2023-06-16 Docket documentCost of Reformulating Foods and Cosmetics
2023-06-16 Docket documentRisk Management for Perchloroethylene Supplemental File: Consumer Risk Calculator
2023-06-16 Docket documentPerchloroethylene: Fenceline Technical Support - Air Pathway
2023-06-16 Docket documentDevelopment of Refined Emission Inventory and Risk Reduction Guidelines for Motion Picture Film Processing
2023-06-16 Docket documentFinal Report of the Small Business Advocacy Review Panel on EPA's Planned Proposed Rule Toxic Substances Control Act (TSCA) Section 6(a) Perchloroethylene (PCE)
2023-06-16 Docket documentScientific Assessment of Ozone Depletion: 2018. Global Ozone Research and Monitoring Project - Report No. 58
2023-06-16 Docket documentNonpoint Expected Pollutant List for 2017 NEI
2023-06-16 Docket documentCalifornia Dry Cleaning Industry Technical Assessment Report
2023-06-16 Docket documentFinal Risk Evaluation for Perchloroethylene Supplemental File Risk Calculator for Occupational Exposures
2023-06-16 Docket documentTable of Size Standards
2023-06-16 Docket documentUltrasonic Aqueous Parts Cleaning in Auto Repair
2023-06-16 Docket documentLess Toxic Auto Repair: Degrease with Aqueous
2023-06-16 Docket documentRegulation for Reducing Emissions from Consumer Products
2023-06-16 Docket documentScience Advisory Committee on Chemicals Meeting Minutes and Final Report No. 2022-01

References: 1,700 extracted, 0 linked to papers

Page 4Download these results: CSV · JSON
Liu BYH, Pui DYH, Rubow KL, Szymanski WW [1985]. Electrostatic effects in aerosol sampling and filtration. Ann Occup Hyg 29:251-269.
journal articleNot linked to a paper · refsec
Lodge JP, Chan TL, eds. [1986]. Cascade impactor sampling and data analysis. Akron OH: American Industrial Hygiene Association.
research reportNot linked to a paper · refsec
Lowrey L, Tillery M [1979]. Filter weight stability evaluation. LA-8061-MS. Los Alamos, NM: Los Alamos National Laboratory.
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter AE April 2016 Page AE-31 of AE-35 Factors Affecting Aerosol Sampling Lynch JR [1970]. Evaluation of size-selective presamplers: I. Theoretical cyclone and elutriator relationships. Am Ind Hyg Assoc J 31:548-551. Mark D [1974]. Problems associated with the use of membrane filters for dust sampling when compositional analysis is required. Ann Occup Hyg 17:35-40.
journal articleNot linked to a paper · refsec
Mark D, Borzucki G, Lynch G, Vincent JH [1988]. The development of a personal sampler for inspirable, thoracic and respirable aerosol. Unpublished paper presented at Annual Conference of the Aerosol Society, Bournemouth, UK, March 22-24. Marple VA [1978]. Simulation of respirable penetration characteristics by inertial impaction. J Aerosol Sci 9:125-134.
journal articleNot linked to a paper · refsec
Marple VA, Olson B [2011]. Sampling and measurement using inertial, gravitational, centrifugal, and thermal techniques. In: Kulkarni P, Baron P, Willeke K, eds. Aerosol measurement: principles, techniques and applications. 3rd ed. New York: John Wiley & Sons, Inc., pp. 129-151. Maynard AD [1996]. Sampling errors associated with sampling plate-like particles using the Higgins- and Dewell-type personal respirable cyclone. J Aerosol Sci 27:575-586. Maynard AD [1999]. Measurement of aerosol penetration through six personal thoracic samplers under calm air conditions. J Aerosol Sci 30:1227-1242.
journal articleNot linked to a paper · refsec
Maynard AD, Baron PA, Foley M, Shvedova AA, Kisin ER, Castranova V [2004]. Exposure to carbon nanotube material: Aerosol release during the handling of unrefined single-walled carbon nanotube material. J Toxicol Environ Health, Part A 67:87-107.
journal articleNot linked to a paper · refsec
NCASI [1992]. Comparison of personal sampling devices for the estimation of wood dust exposure levels. Special Report No. 92-09. Cary, NC: National Council for Air and Stream Improvement.
research reportNot linked to a paper · refsec
NIOSH [1984]. Accuracy criteria recommended for the certification of gravimetric coal mine dust samplers. By Bowman JD, Bartley DL, Breuer GM, Doemeny LJ, Murdock DJ.
research reportNot linked to a paper · refsec
NIOSH [1994]. Particulates not otherwise regulated: Method 0500. In: Eller PM, Cassinelli
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter AE April 2016 Page AE-32 of AE-35 Factors Affecting Aerosol Sampling Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 94-113. [www.cdc.gov/niosh/nmam/].
research reportNot linked to a paper · refsec
NIOSH [1995]. Guidelines for air sampling and analytical method development and evaluation. By Kennedy ER, Fischbach TJ, Song R, Eller PM, Shulman SA. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 95117.
research reportNot linked to a paper · refsec
NIOSH [1998]. Criteria for a recommended standard: occupational exposure to metalworking fluids. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 98-102. Notø H, Halgard K, Daae HL, Bentsen RK, Eduard W [1996]. Comparative study of an inhalable and a total dust sampler for personal sampling of dust and polycyclic aromatic hydrocarbons in the gas and particulate phase. The Analyst 121:1191-1196.
journal articleNot linked to a paper · refsec
Perrault G, Drolet D, Cloutier Y [1996]. Comparison of total and inhalable samplings of wood dust. Unpublished paper presented at American Industrial Hygiene Conference and
research reportNot linked to a paper · refsec
Exposition, Washington, D.C., May 18-24. Puskar MA, Harkins JM, Moomey JD, Hecker LH [1991]. Internal wall losses of pharmaceutical dusts during closed-face, 37-mm polystyrene cassette sampling. Am Ind Hyg Assoc J 52:280-286.
journal articleNot linked to a paper · refsec
Puskar MA, Fergon SM, Harkins JM, Hecker LH [1992]. Gravimetric determination of airborne dust by using a filter cartridge inside a closed-face, 37-mm polystyrene cassette. Am Ind Hyg Assoc J 53:692-698.
journal articleNot linked to a paper · refsec
Qi C, Echt A, Gressel MG [2016]. On the characterization of the generation rate and sizedependent crystalline silica content of the dust from cutting fiber cement siding. Ann Occup Hyg 60(2):220-230, http://dx.doi.org/10.1093/annhyg/mev066.
journal articleNot linked to a paper · refsec · cited link
Ramachandran G, Sreenath A, Vincent JH [1998]. Towards a new method for experimental determination of aerosol sampler aspiration efficiency in small wind tunnels. J Aerosol Sci 29:875-891.
journal articleNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter AE April 2016 Page AE-33 of AE-35 Factors Affecting Aerosol Sampling
research reportNot linked to a paper · refsec
Raynor PC, Leith D, Lee KW, Mukund R [2011]. Sampling and analysis using filters. In:
research reportNot linked to a paper · refsec
Kulkarni P, Baron PA, Willeke K, eds. Aerosol measurements: principles, applications, and techniques. 3rd ed. New York: John Wiley and Sons, Inc., pp.107-128. Robert KQ [1979]. Cotton dust sampling efficiency of the vertical elutriator. Am Ind Hyg Assoc J 40:535-542.
journal articleNot linked to a paper · refsec
Rodes CE, Kamens RM, Wiener RW [1995]. An experimental design to study the dispersal of contaminants released in close proximity to the body. Am Ind Hyg Assoc J 56:535-545.
journal articleNot linked to a paper · refsec
Sass-Kortsak AM, O'Brien CR, Bozek PR, Purdham JT [1993]. Comparison of the 10-mm nylon cyclone, horizontal elutriator, and aluminum cyclone for silica and wood dust measurements. Appl Occup Environ Hyg 8:31-37.
journal articleNot linked to a paper · refsec
Smith JP, Bartley DL, Kennedy ER [1997]. Laboratory investigation of the mass stability of sampling cassettes from inhalable aerosol samples. Am Ind Hyg Assoc J 59:582-585.
journal articleNot linked to a paper · refsec
Tsai CJ, Liu CN, Hung SM, Chen SC, Uang SN, Cheng YS, Zhou Y [2012]. Novel active personal nanoparticle sampler for the exposure assessment of nanoparticles in workplaces. Environ Sci Technol 46(8):4546-4552. Van den Heever DJ [1994]. Quantification of bypass leakage in two different filter cassettes during welding fume sampling. Am Ind Hyg Assoc J 55:966-969.
journal articleNot linked to a paper · refsec
Vaughan NP, Chalmers CP, Botham RA [1990]. Field comparison of personal samplers for inhalable dust. Ann Occup Hyg 34:553-573. Vincent JH [2007]. Aerosol sampling: science, standards, instrumentation, and applications. New York: John Wiley & Sons, Inc. Vincent JH [1999a]. Sampling criteria for the inhalable fraction. In: Vincent JH, ed. Particle size-selective sampling for particulate air contaminants. Cincinnati OH: American Conference of Governmental Industrial Hygienists. pp. 51-72.
journal articleNot linked to a paper · refsec
Vincent JH, ed. [1999b]. Particle size-selective sampling for particulate air contaminants.
research reportNot linked to a paper · refsec
Vincent JH, Aitken RJ, Mark D [1993]. Porous plastic foam filtration media: penetration characteristics and applications in particle size-selective sampling. J Aerosol Sci 24:929-944.
journal articleNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter AE April 2016 Page AE-34 of AE-35 Factors Affecting Aerosol Sampling
research reportNot linked to a paper · refsec
Wilsey PW, Vincent JH, Bishop MJ, Brosseau LM, Greaves IA [1996]. Exposures to inhalable and "total" oil mist aerosol by metal machining shop workers. Am Ind Hyg Assoc J 57:11491153.
research reportNot linked to a paper · refsec
Witschger O, Willeke K, Grinshpun SA, Aizenberg V, Smith J, Baron PA [1997]. Simplified method for testing personal aerosol samplers. J Aerosol Sci 29:855-874.
journal articleNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter AE April 2016 Page AE-35 of AE-35
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-2 of BA-115 Sampling and Characterization of Bioaerosols internal and external sources of bioaerosols; and other measures [Macher 1999]. In general, if visible growth or contamination (microbial growth on floors, walls, or ceilings, or in the
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-3 of BA-115 Sampling and Characterization of Bioaerosols Figure 1: Photomicrographs of acellular, prokaryotic and eukaryotic microorganisms that can be encountered in occupational or industrial environments. (A) Transmission electron micrograph of Influenza/flu (H1N1) virus particles (Photo courtesy of National Institute of Allergy and Infectious Diseases; CDC Public Health Image Library (PHIL) ID#: 18156); (B) Scanning electron micrograph of bacilli derived from the Gram-negative bacteria, Legionella pneumophila (Photo courtesy of National Institute of Allergy and Infectious Diseases; CDC Public Health Image Library (PHIL) ID#: 11150); (C) Scanning electron micrograph of Aspergillus species reproductive structures including chains of asexual spores (Photo courtesy of CDC/ Robert Simmons; CDC Public Health Image Library (PHIL) ID#: 13367); and (D) Scanning electron micrograph of tricolpate pollen derived from the angiosperm plant species, Oenothera fruticosa (Photo courtesy of CDC/ Janice Carr, Betsy Crane; CDC Public Health Image Library (PHIL) ID#: 8729). The CDC Public Health Image Library at http://phil.cdc.gov/Phil/home.asp has thousands of health-related images available to the public free of charge.
research reportNot linked to a paper · refsec · cited link
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-18 of BA-115 Sampling and Characterization of Bioaerosols of proteins and other additives can also greatly influence the survival of airborne viruses during collection by impingers [Ijaz et al. 1985b; Schaffer et al. 1976; Verreault et al. 2008]. Water loss over time reduces the liquid level in the impinger and increases the concentration of the non-volatile components, which limits the available collection time [Lin et al. 1997]. Sample losses due to re-aerosolization and particle deposition inside the impinger can be significant [Grinshpun et al. 1997; Han and Mainelis 2012]. Figure 8: Impingement. Bioaerosol particles exit the nozzle of the impinger at high velocity and impact the liquid or the bottom surface of the collection vessel. Some types of impingers produce air bubbles in the collection media, which can enhance particle collection, but can damage some types of microorganisms. Two common impingers used for bioaerosol sampling are the Greenburg-Smith impinger [Greenburg 1932] and the All-Glass Impinger with the nozzle 30 mm above the base of the collection vessel, called the AGI-30 [May and Harper 1957]. The Greenberg-Smith and
research reportNot linked to a paper · refsec
AGI-30 samplers operate by drawing aerosols at nominal flow rates of 28.3 and 12.5 L/min, respectively, through an inlet tube [Macher et al. 1995]. The AGI-30 inlet tube is curved to simulate particle collection in the nasal passage [Cox 1987]. Investigators have reported problems with low sampling efficiencies and high losses due to particles in the collection being re-aerosolized and lost [Grinshpun et al. 1997; Kesavan et al. 2010; Lin et al. 1997]. When the AGI-30 is used to recover total airborne organisms from the environment, the curved inlet tube is washed with a known amount of collecting fluid after sampling because larger particles (i.e., over 15 µm) are collected on the tube wall by inertial force. After sampling for the appropriate amount of time, 10 mL of the full-strength collection
research reportNot linked to a paper · refsec
Alternatively, fluid can be exchanged or added to the sampler as needed [Rule et al. 2005; Rule et al. 2007]. The CIP10-M, a modified version of the CIP10 aerosol sampler, collects airborne microorganisms in a liquid layer on the interior surface of a rapidly-rotating cup. As with the BioSampler, the CIP10-M can be used with mineral oil as the collection fluid to avoid fluid evaporation. It is reported to have collection efficiencies of >80% for particles >2.8 µm, 50% for 2.1 µm particles, and <10% for particles of <1 µm [Görner et al. 2006; Simon et al. 2016]. May [1966] designed a three-stage sampler in which aerosol particles are collected by impaction onto a wetted fritted surface in the first two stages and the third stage is a swirling aerosol collector similar to the BioSampler. Both glass and stainless steel versions are available. In his original report, May [1966] used particles with a density of 1.5 g/cm3 and reported cut-off sizes of 6 µm, 3.3 µm and 0.7 µm, which correspond to aerodynamic diameters of about 7.3 µm, 4 µm, and 0.86 µm. The May sampler is reported to give comparable results to the Andersen impactor [Zimmerman et al. 1987].
research reportNot linked to a paper · refsec
EDC’s have been used in studies of culturable bacteria and fungi, endotoxin, glucan and inflammatory mediators in airborne particles [Adams et al. 2015; Frankel et al. 2012; Huttunen et al. 2016; Kilburg-Basnyat et al. 2016; Kilburg-Basnyat et al. 2015; Noss et al. 2010; Noss et al. 2008]. Noss et al. [2008] and Frankel et al. [2012] reported good correlations between the EDC and active aerosol samplers. Adams et al. [2015] compared EDC’s to Petri dishes and other passive collection materials and found that the results correlated reasonably well, but that a rigorous extraction protocol was required to get consistent results from the EDC’s. Brown et al. [1996] developed a passive electrostatic-based personal aerosol sampler and reported that it gave a reasonable correlation with inhalable dust measurements at farms and a rubber plant. Other passive bioaerosol samplers The UNC Passive Aerosol Sampler consists of a 6.8 mm diameter collection substrate mounted on a scanning-electron microscope stub and shielded by a protective screen [Wagner and Macher 2003; Whitehead and Leith 2008]. Airborne particles settle or diffuse onto the substrate and can be analyzed by optical or electron microscopy. Other investigators have used aluminum sheets in boxes, Petri dishes, and sheets of various plastic materials as passive bioaerosol collectors [Adams et al. 2015; Meadow et al. 2015; Wurtz et al. 2005].
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-25 of BA-115 Sampling and Characterization of Bioaerosols food-contact surfaces [Dyer et al. 2004], while the USP and ISO have standards that include swab sampling for microbiological contamination in clean rooms [ISO 2003;
research reportNot linked to a paper · refsec
USP 1997]. An example of a validated protocol for swab sampling is that provided by NIOSH for surface sampling for Bacillus anthracis spores [Hodges et al. 2010; Hodges et al. 2006;
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-26 of BA-115 Sampling and Characterization of Bioaerosols to microbial growth if the elution media or swab contain nutrients, while the presence of chemicals such as Tween 80 may reduce viability over time. These problems can be alleviated by placing the swabs in cold storage as quickly as possible [Moore and Griffith 2007]. Wipes All of the considerations and limitations of swab sampling also apply to wipe sampling. Swabs are typically more useful for small surfaces and hard-to-reach locations, while wipes are more effective at collecting dust from large non-porous surfaces [NIOSH 2012b]. Electrostatic wipes have been used to collect settled dust for studies of mold and endotoxin [Bolaños-Rosero et al. 2013; Thorne et al. 2005].
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-27 of BA-115 Sampling and Characterization of Bioaerosols j. Heating, ventilation and air conditioning (HVAC) filters Building HVAC systems filter large quantities of outside and recirculated inside air as they maintain environmental conditions inside buildings. Researchers have taken advantage of these existing filtration systems as a way to study bioaerosols in a variety of structures [Goyal et al. 2011; Haaland and Siegel 2016; Noris et al. 2011]. Testing the collected particulate material on HVAC filters provides an inexpensive way of studying bioaerosols collected from large volumes of air over long time periods. However, some limitations must be kept in mind. Extracting bioaerosols from these filters can be difficult and the methods require validation [Farnsworth et al. 2006]. Many microorganisms lose viability after collection, so although PCR-based methods may be effective, culture-based methods likely will not work except for very hardy microbes [Farnsworth et al. 2006]. Finally, commonly-used HVAC filters can have relatively low collection efficiencies, especially for small particles [ASHRAE 2009]. Haaland and Siegel [2016] reviewed 60 studies in which
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-29 of BA-115 Sampling and Characterization of Bioaerosols The concentrations of bioaerosol particles vary widely depending upon the meteorological parameters, the location of sources, the time of year and the amount of ventilation. Shelton et al. [2002] studied 1,717 buildings in the United States. They found that outdoor levels of airborne fungi are usually higher than indoor levels, and that fungal levels were highest in the fall and summer and lowest in the winter and spring. Outdoor levels varied from 1 to more than 8,200 colony-forming units (CFU)/m3 of air, with a median of 540
research reportNot linked to a paper · refsec
CFU/m3. An examination of fungi in flood-damaged homes found fungal concentrations of 1,100 to 8,400 spores/m3 outside and 500 to 101,100 spores/m3 inside [Reponen et al. 2007]. An investigation of 100 large office buildings by Tsai and Macher [2005] found that airborne bacterial concentrations tend to be higher outdoors than indoor (except for Gram-positive cocci). Outdoor concentrations tended to be higher in the winter (194 vs. 165 CFU/m3), while indoor concentrations were higher in the summer (116 vs. 87
research reportNot linked to a paper · refsec
CFU/m3). Forty-one percent of the bioaerosol samples were below the detection limit, and >95% of the culturable bacteria were mesophilic (grow at moderate temperatures). In a report on agricultural workers working in animal confinements, Lee et al. [2006] found breathing zone culturable bioaerosol exposures of 300 to 36,000 CFU/m3 for fungi, 3000 to 3.3 x 108 CFU/m3 for bacteria, and up to 2,800 CFU/m3 for actinomycetes. During grain harvesting, workers were exposed to culturable bioaerosol levels of 82,000 to 7.4 × 106
research reportNot linked to a paper · refsec
RH but was reduced at RH values above 80% [Cox 1968]. Higher humidities can also significantly decrease the efficacy of ultraviolet germicidal irradiation (UVGI) for reducing levels of viable airborne bacteria [Peccia et al. 2001]. Cox [1987] believes the potential for the movement of the solvent water is an important environmental criterion in assessing survivability of bacteria, viruses, and phages. Fungi and fungal spores generally are better able to withstand environmental stresses compared to vegetative bacteria and viruses [Ijaz et al. 2016; Tang 2009]. Warm temperatures, wet substrates and humid air conditions favor the growth of fungi on surfaces [Eduard 2009; Tang et al. 2015]. Temperature can induce morphological changes in dimorphic fungi such as the pathogen Histoplasma capsulatum [Salvin 1949]. It is not clear, however, how air temperature and humidity affect the viability of airborne fungi and fungal spores [Tang 2009].
research reportNot linked to a paper · refsec
PCR has been used for rapid detection of Histoplasma capsulatum and mycobacteria [Reid and Schafer 1999; Schafer et al. 1999; Schafer et al. 2003]. A DNA-based mold specific quantitative PCR (msQPCR) method is widely used to evaluate indoor fungal bioaerosols in the academic, government and commercial sectors, and is the basis for the Environmental Relative Moldiness Index (ERMI) used to quantify mold contamination in
research reportNot linked to a paper · refsec
NIOSH Method 0800 discusses sampling for culturable airborne bacteria and fungi with an Andersen cascade impactor [NIOSH 2003b]. Standard methods for the collection of airborne fungi by inertial impaction are presented in ASTM Standards D7788 [ASTM 2009; ASTM 2014d]. ASTM Standard D7391 also discusses the aspects related to the laboratory analysis. b. Sampling for airborne viruses Airborne viruses are more difficult to study in bioaerosols than bacteria and fungi for a variety of reasons [Prussin et al. 2014; Verreault et al. 2008]. Viruses are more difficult to culture because they are obligatory intracellular parasites that require a host cell for
research reportNot linked to a paper · refsec
NIOSH Manual of Analytical Methods  5th Edition  Chapter BA March 2017 Page BA-37 of BA-115 Sampling and Characterization of Bioaerosols reproduction [Tortora et al. 2013]. Bioaerosols of pathogenic viruses have been found in many settings to be present in low concentrations that can be difficult to detect [Blachere et al. 2009; Bonifait et al. 2015; Lindsley et al. 2010a; Tseng et al. 2010; Yang et al. 2011]. Viruses also are generally more susceptible to damage during aerosol collection than are bacteria or fungi, although their sensitivity varies widely with the collection method and species [Appert et al. 2012; Turgeon et al. 2014; Zuo et al. 2013]. Aerosol sampling methods for viruses have been reviewed by Verreault et al. [2008]. Bacteriophages are viruses that infect bacteria rather than multicellular organisms. They are used in laboratory aerosol studies as tracers for aerosol particles and as surrogates for airborne viruses that infect humans [Fisher et al. 2012; Tseng and Li 2005; Turgeon et al. 2014]. Bacteriophages are not known to be hazardous to humans but are of interest to industries that rely on bacteria such as cheese manufacturers [Verreault et al. 2011]. Polymerase chain reaction (PCR) based methods are often used to study viral bioaerosols.
research reportNot linked to a paper · refsec
PCR has the advantages of being very sensitive and very specific, and considerably easier to perform than viral cultural assays. For this reason, most recent field studies of airborne viruses have used PCR as the detection method. Examples include studies of viruses in healthcare facilities [Blachere et al. 2009; Booth et al. 2005; Lindsley et al. 2010a; Thompson et al. 2013; Tseng et al. 2010], influenza at poultry and pig farms [Corzo et al. 2013; Jonges et al. 2015], airborne viruses in a sewage treatment plant [Masclaux et al. 2014], and respiratory viruses in human coughs and exhaled breath [Gralton et al. 2013; Lindsley et al. 2010b; Milton et al. 2013].
research reportNot linked to a paper · refsec
← PreviousNext →