U.S. Environmental Protection Agency. 1999. The Class V Underground Injection Control Study. Part 2, Volumes 11 through 23. Office of Ground Water and Drinking Water. EPA 816/R-99-014. September 1999. 904 pp. [W-98-05-IV-C-8-]
Other documents for the same rulemaking (all, by stage)
References: 505 extracted, 0 linked to papers
Radig, S. 1997. Memorandum to Anhar Karimjee, Office of Water, U.S. Environmental Protection Agency, October 27, 1997. North Dakota Department of Health, Division of Water
Quality, Bismarck ND. Second Imperial Geothermal Company. 1993. Second Imperial Geothermal Project: Injection Project Permit Application, Heber Geothermal Unit, Imperial County, California. Received by
CDOG, El Centro, CA. June 1993. Stock, D.D. and L.L. Orser, L.L. 1990. Geothermal Reinfection at Dixie Valley, Nevada. In: Proceedings of the Symposium on Subsurface Injection of Geothermal Fluids, held in Santa
Rosa, CA, October 29-30,1990. Underground Injection Practices Council Research Foundation.
Stollar, R.L. & Associates. 1989. Report of the Assessment of the Impact of Present Use and Additional Development of Groundwater Resources at the Ormesa Geothermal Project, Imperial
County, California. Santa Ana, California. May 10,1989. U.S. Department of Energy (DOE), 1998b. Uses of Geothermal Energy: Power Plants and Wells. Geothermal Energy Technical Site. Available: http://geothermal.id.doe.gov/geothermal/ powerplants.html [October 29,1998]. U.S. Department of Energy (DOE), 1998a. Geothermal Electricity Production. U.S. Department of Energy, Office of Geothermal Technologies. Available: http://www.eren.doe.gov/geothermal/gep.html [November 4, 1998]. September 30, 1999 P.57 U.S. Department of the Interior, Bureau of Land Management (USBLM). 1998. Injection well files for the East Mesa geothermal field in El Centra, California office. U.S. EPA. 1984. National secondary drinking water regulations. Publication No. EPA 570/976-000. U.S. EPA. 1987. Report to Congress: Class V Injection Wells. U.S. Environmental Protection
Agency, Office of Water, EPA 570/987/006. U.S. EPA. 1993. Health Advisories for Drinking Water Contaminants. Office of Water Health Advisories. Lewis Publishers, Ann Arbor. U.S. EPA. 1996. Drinking Water Regulations and Health Advisories. Office of Water. EPA 822-B-96-002. U.S. EPA. 1998. National primary drinking water regulations. 40 CFR §141.32. U.S. EPA. 1999a. Integrated Risk Information System (IRIS). Cincinnati, OH: Office of Research and Development, National Center for Environmental Assessment. Available: http://www.epa.gov/ngispgm3/iris/index.html [March. 1999]. U.S. EPA. 1999b. National Primary Drinking Water Regulations Technical Fact Sheets.
Washington, D.C: Office of Water, Office of Ground Water and Drinking Water. Available: http://www.epa.gov/OGWDW/hfacts.htmltMarch]. U.S. EPA. 1999c. Sulfate in Drinking Water. Office of Ground Water and Drinking Water. Available: http://www.epa.gov/OGWDW/sulfate.html. April U.S. EPA, Region 9. 1991. Final EPA-CDOG Memorandum of Agreement for Geothermal Energy Injection Wells in California. July 29 U.S. EPA, Region 9. 1998. Underground Injection Control Draft Individual Permit, Class V
Injection, Permit No. HI596002. U.S. EPA, Region 9. 1999. Administrative record for the UIC permit to Puna Geothermal Venture/Puna COSI, Inc. U. S. Geological Survey. 1994. Potential Effects of the Hawaii Geothermal Project on GroundWater Resources on the Island of Hawaii. USGS Report No. 94-4028.
Unocal Corporation. 1998. 1997 Analyses of geothermal condensate grab samples taken from each power plant condensate pond and effluent samples from the South East Geysers. February 11,1998. September 30, 1999 P.58
Vetter, O. 1979. Injection, Injectivity and Injectability in Geothermal Operations. Geothermal Resources Council Transactions. 3:749-752. September 1979.
White, D.E., L.P. Muffler, and A.H. Truesdell. 1971. Vapor-dominated Hydrothermal Systems Compared with Hot-Water Systems. Economic Geology. 66:75-97. 1971.
Williams, A.E., and M.A. McKibben. 1989. A brine interface in the Salton Sea Geothermal
System, California: Fluid geochemical and isotopic characteristics. Geochemical et. Cosmochimica Acta. 53:1905-1920. September 30, 1999 P.59 United States Environmental Protection Agency oEPA Office of Ground Water and Drinking Water (4601)
EPA/816-R-99-014r September 1999 The Class V Underground Injection Control Study Volume 18 Geothermal Direct Heat Return Flow Wells P.60 Table of Contents Page Summary Introduction Prevalence of Wells Injectate Characteristics and Injection Practices Injectate Characteristics Well Characteristics Well Siting 4.4 • Well Operation Potential and Documented Damage to USDWs Injectate Constituent Properties Observed Impacts Best Management Practices Current Regulatory Requirements ..'. Federal Programs
Oregon, but Alaska also indicated the potential presence of these wells without providing an estimated number. Individual permits are required for geothermal direct heat return flow wells in all five of the states that have most of these wells. In Idaho, an individual permit is not required if the well is <18 feet deep, but all of the geothermal direct heat return flow wells are substantially deeper than 18 feet. Individual permit requirements, which also apply in California, are similar in many respects to those for Class II wells. Further, for wells located on federal land, Bureau of Land Management (BLM) approval of well drilling, testing, and abandonment is also required by regulations promulgated under the Geothermal Steam Act of 1970.
Anderson, J. 1981. Drilling and Completion Report, Capitol Mall Geothermal Exploratory Well # 1. Idaho Department of Water Resources, Statehouse, Boise, Idaho. Report prepared as part of the US DOE Contract DE-AS07-77ET28407. April 1981.
Culver, G. 1988. "Overview of Geothermal Direct Use Injection Wells." In: Proceedings of the International Symposium on Class VInjection Well Technology, September 13-15,1988, Las
Foundation, pp. 247-256. Culver, G. 1989. "Direct Use Injection Wells." Geo_Heat Center Quarterly Bulletin, v. 11, n. 4. Oregon Institute of Technology, Klamath Falls, Oregon. Summer 1989.
Culver, G. 1990a. "Case Histories of Vale, Oregon and Susanville, California." Klamath Falls, Oregon: Geo-Heat Utilization Center, Oregon Institute of Technology.
Culver, G. 1990b. "Geothermal Injection Monitoring in Klamath Falls, OR." Klamath Falls, Oregon: Geo-Heat Utilization Center, Oregon Institute of Technology.
Cunniff, R. A., Houghton, C , and Chintawongvanich, P. 1983. Geothermal Reinjection Well Completion and Testing. New Mexico State University, Las Cruces, New Mexico.
Cunniff, R. A., Houghton, C , and Clanton, M. 1982. Technical Completion Report: Testing and Repair, NMSU Geothermal Disposal Well (Old Golf Course Well). New Mexico State
University, Physical Science Laboratory. Fortuna, R. 1999. Manager, Direct Use Program, Office of Geothermal Energy, U.S. Department of Energy. Telephone conversation with K. Temple, ICF Consulting. July 20,1999. Geo-Heat Center, Oregon Institute of Technology. 1998a. "South Dakota: Natural Heating Thousands of West River Residents Go Geothermal," Geo-Heat Bulletin, 19(2). Geo-Heat Center, Oregon Institute of Technology. 1998b. U.S. Geothermal Project Resource Areas. Available: http://www.oit.osshe.edu/~geoheat/
GeothermEx, Inc. 1984. An Assessment ofthe Geothermal Resource Underlying the City of Susanville and the Disposal System for Geothermal Waste Water. Prepared by GeothermEx, Inc., Richmond, CA. November 1984.
James M. Montgomery Consulting Engineers, Inc. 1987. Report on Drilling, Development, and Testing ofthe Veterans Administration Medical Center Geothermal Injection Well, Boise, Idaho. February 1987.
Johnson, K.A. 1999. Peer review comments submitted to USEPA. June 18, 1999. September 30, 1999 Klamath Environmental Services (KES). 1988. Analysis Report for Water Sample 88-C158 from Lucille O'Neil Production Well. June 3,1988. Klamath Environmental Services (KES). 1990a. Analysis Report for Water Sample 90-C218 from OIT Injection Well #1. April 10,1990. Klamath Environmental Services (KES). 1990b. Analysis Report for Water Sample 90-C780 from OIT Injection Well #1. June 20,1990. Klamath Environmental Services (KES). 1990c. Analysis Report for Water Sample 90-C734 from Lucille O'Neil Injection Well. June 13,1990. Klamath Environmental Services (KES). 1990d. Analysis Report for Water Sample 90-C407 from Lucille O'Neil Production Well. April 20,1990.
Land, R. 1997. Nevada Division of Environmental Protection. Memorandum to Anhar
Karimjee, US EPA, Office of Water. October 30, 1997.
Land, R. 1999a. Nevada Bureau of Water Pollution Control. Electric power geothermal injection well injectate characteristic information. Carson City, Nevada. April 4,1999.
Land, R. 1999b. Nevada Division of Environmental Protection. E-mail correspondence with K.
Temple, ICF Consulting. July 20,1999. Lund, J.W. 1990. "Geothermal Heat Pump Utilization in the United States." Geo-Heat Bulletin, 11(1). Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, Oregon.
Lund, J.W., Culver, G., Lienau, P.J. 1989. Ground water Characteristics and Corrosion Problems Associated with the Use of Geothermal Water in Klamath Falls, Oregon. Geo-Heat Utilization Center, Oregon Institute of Technology, Klamath Falls, Oregon.
METALogic NV. 1998. Oxidizing and Reducing Conditions in High Temperature Corrosion. Available: ht^://www.metalogic.be/MatWeb/reading/gas/ka_ht/ox_red_t.htm [June 30, 1998].
Montgomery Watson. 1998. City of Boise Geothermal Injection Well Construction and Testing Report. Boise, Idaho. June 1998. New Mexico State University (NMSU). 1983. Geothermal Reinjection Well Completion and
Radig, S. 1997. NorthDakotaDepartmentofHealth, Division of Water Quality. Memorandum to Anhar Karimjee, USEPA, Office of Water. October 27,1997. September 30, 1999
Turcan, A. N., Jr. 1959. U. S. Dept. of Interior, U. S. Geological Survey, Water Resources
Division, baton Rouge, Louisiana. Letter to I. A. Mayeaux, B. F. Edington Drilling Co. regarding geothermal wells R-617 and R-618. January 2,1959. U.S. Department of Energy (DOE). February 1996. Use of Geothermal Resources. DOE/GO10096-035. USDOE National Renewable Energy Laboratory. Available: http://www.eren.doe.gov/geothermal/direct. html [November 11,1998]. U.S. EPA. 1984. National secondary drinking water regulations. Publication No. EPA 570/976-000. U.S. EPA. 1987. Report to Congress: Class V Injection Wells. EPA 570/9-87-006.
Washington, DC: USEPA, Office of Water. September 1987. U.S. EPA. 1992. Integrated Risk Information System (IRIS) Background Document 4: U.S. EPA Regulatory Action Summaries. Cincinnati, OH: Office of Research and Development. January 1992. U.S. EPA. 1993. Health Advisories for Drinking Water Contaminants. Office of Water Health Advisories. Lewis Publishers, Ann Arbor. U.S. EPA. 1996. Drinking Water Regulations and Health Advisories. Office of Water. EPA 822-B-96-002. U.S. EPA. 1998. National secondary drinking water regulations. 40 CFR §143. U.S. EPA. 1999a. Integrated Risk Information System (IRIS). Cincinnati, OH: Office of Research and Development, National Center for Environmental Assessment. Available: http://www.epa.gov/ngispgm3/iris/index.html [April]. U.S. EPA. 1999b. Sulfate in Drinking Water. Office of Ground Water and Drinking Water. Available: http://www.epa.gov/OGWDW/sulfate.html [April]. U.S. House of Representatives. 1992. "Hearing before the Subcommittee on Environment ofthe Committee on Science, Space, and Technology." 102nd Congress, 2nd Session, 7/30/92 [#155]
Washington, DC: U.S. Government Printing Office. September 30, 1999 United States Environmental Protection Agency Office of Ground Water and Drinking Water (4601)
EPA/816-R-99-014S September 1999 A p p A The Class V Underground Injection « f r t n r \ Control Study Volume 19 Heat Pump and Air Conditioning Return Flow Wells Table of Contents Page Summary Introduction Prevalence of Wells Wastewater Characteristics and Injection Practices Injectate Characteristics Well Characteristics 4.2.1 Well Types 4.2.2 Well Design Operational Practices Potential and Documented Damage to USDWs Potential Injectate Impacts to USDWs 5.1.1 Thermal Alteration 5.1.2 Mineral Precipitation Due to Changes in Water Pressure or Oxygen Levels 5.1.3 Chemical Contamination 5.1.4 Water Quantity Observed Impacts
HAC injectate can also contain: metals leached from the pipes and pumps; bacteria (where oxygen, nutrients, and a source of bacteria are present); precipitated ferric iron solids (where dissolved iron is present in source water, and the HAC system introduces oxygen); and chemical additives (sometimes used for disinfection or corrosion prevention). Very little data on injectate properties were available for this study. However, the available data indicate that HAC injectate has in some cases exceeded the primary drinking water maximum contaminant levels (MCLs) for lead and copper and the secondary MCLs for chloride and total dissolved solids (TDS). September 30, 1999
Atlanta, GA. pp. 29.14-29.25. Andrews, CB. 1978. Impact ofthe Use of Heat Pumps on Ground-water Temperatures. Ground Water 16(6):437-443.
Armitage, D.M., Bacon, D.J., Massey-Norton, J.T., and J.D. Miller. 1980. Ground-water Heat Pumps: an Examination of Hydrogeologic, Environmental, Legal, and Economic Factors Affecting Their Use. U.S. Department of Energy. Washington, D.C. DOE/CS/200605120(V.l). Caneta Research, Inc. 1995. Commercial/Institutional Ground-Source Heat Pump Engineering Manual. Prepared for U.S. DoD, U.S. DOE, WaterFumace International, Inc., Public Works and Government Services Canada, Natural Resources Canada, Ontario Ministry of Environment and
Clyde, C.G. and G.V. Madabhushi. 1983. Spacing of Wells for Heat Pumps. Journal of Water Resources Planning and Management 109(3):203-212.
Convery, M. 1992. Lead in Injection Well (Park Rapids). Ground Water and Solid Waste
Division, Minnesota Pollution Control Agency. Memorandum to Roman Koch, Hydrologist, Well Management Unit, Minnesota Department of Health. July 7,1992.
Elder, J.R. and S.K. Lowrance. 1992. Directors, USEPA Office of Ground Water and Drinking Water and USEPA Office of Solid Waste (respectively). Classification of Infiltration Galleries Under the UIC and RCRA Programs. Memorandum to USEPA Region 1-10 Water Management Division Directors and Hazardous Waste Management Division Directors.
Englund, G. 1984. Lead Content in Heat Pump Injection Well, Maplewood, Minnesota. Section of Water and Engineering, Minnesota Department of Health. Memorandum to Gordon Meyer,
Englund, G. 1985. Heat Pump Wells, Itasca-Mantrap Co-op, Park Rapids, Minnesota. Section of Water and Engineering, Minnesota Department of Health. Memorandum to Gordon Meyer,