Occurrence of Per- and Polyfluoroalkyl Substances (PFAS) in Source Water and Their Treatment in Drinking Water
Other documents for the same rulemaking (all, by stage)
References: 142 extracted, 0 linked to papers
CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY 2373 2374 B. C. CRONE ET AL. Both size, charge, and other forms of rejection can be impacted by membrane fouling due to, but not limited to, pore blockage, charge exclusion, charge neutralization, adsorption, and resulting membrane degradation (Appleman et al., 2013; Rahman et al., 2014). While fouling typically results in reduced performance, instances of increased PFAS removal have been reported for fouled membranes (Appleman et al., 2013; Steinle-Darling &
PFAS. They are typically comprised of synthetic polymeric materials and with their lower bonding energy, they are more amenable to regeneration than resins with ion exchange properties (Ross et al., 2018). Resins with
CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY 2375 ion exchange properties are charged polystyrene or polyacrylic beads with polystyrene having slightly higher adsorption capacity and polyacrylic having significantly faster kinetics (Deng, Yu, Huang, & Yu, 2010; Dudley, 2012). Polystyrene can either be in a gel or microporous solid form, and there is no measurable difference reported between the two forms (Dudley, 2012). The beads contain charged functional groups saturated with a counter ion, typically chloride, that can be exchanged with PFAS, which primarily exist as anions in solution at drinking water relevant pH values (e.g., pH 6.5 to 8.5 for raw water (APHA, 1989)). Resin properties and their principal applications from literature reported studies are summarized in Table S2 in the SI. Researchers suggested that essential resin characteristics that affect exchange capacity include functional groups, polymer matrix, and porosity (Deng et al., 2010). While the primary removal mechanism in AEX resins is ionic interaction, important secondary mechanisms include: adsorption, agglomeration, hydrophobic interactions, PFAS functional group interactions, and resin functional group interactions (Ross et al., 2018; Zaggia, Conte,
Falletti, Fant, & C, 2016). These secondary removal mechanisms, and especially hydrophobicity, are responsible for reported variability in removal efficiencies among PFAS anions of varying chain lengths (Zaggia et al., 2016). PFAS hydrophobicity and removal during anion exchange treatment increases with fluorinated chain length. Hydrophobicity of the resin can also be adjusted by increasing the chain length of the alkyl substituents when quaternary ammonium functional groups are employed. Zaggia et al. (2016) demonstrated this through increased removal of more hydrophilic
PFBA and PFBS when using a resin with triethyl alkyl groups, which had increased hydrophobicity compared to a resin with trimethyl alkyl groups. The strength of the PFAS functional group also impacts removal as illustrated by the increased removal of PFSAs compared to PFCAs (Dudley, 2012; McCleaf et al., 2017; Zaggia et al., 2016). One notable exception being a five-fold increase in adsorption capacity of PFOA over PFOS reported by
Yu, Zhang, Deng, Huang, and Yu (2009). AEX resins also have the advantage of having higher adsorption capacity than granular activated carbon (GAC), but adsorption tends to be hysteretic and nonreversible, often limiting resins to single use (Carter & Farrell, 2010; Senevirathna et al., 2010b). Deng et al. (2010) and Carter and Farrell (2010) found that conventional resin regeneration methods were not effective, but Liu (2017) found improved resin regeneration in short-chain compared to long-chain PFAS because of their reduced hydrophobicity (Du et al., 2014). While these studies report varying success for regeneration via methanol, brine, or liquid rinses, single-use AEX resins remain the most feasible option for low concentration drinking water applications (Carter & 2376 B. C. CRONE ET AL.
Farrell, 2010; Deng et al., 2010; Liu, 2017; Ross et al., 2018). Also, one major issue with regeneration is the production of a concentrated waste stream that must be disposed of or further treated, like membrane treatment. Although resins are used in fixed-bed adsorbers in general drinking water treatment practice, most studies focused on batch isotherm and kinetic tests for removing PFOS, though several studies report values for
Wiberg, and Ahrens (2017) found NOM presence to have a slight negative impact on PFAS adsorption over a dissolved organic carbon (DOC) ranging from 2 to 8 mg C/L. Further work is needed to elucidate the complex interactions between NOM, PFAS, important anions, and AEX resins. 4.2. Summary of pilot and Full-Scale AEX resin evaluations for PFAS removal Several studies have evaluated AEX at the pilot- or full-scale level (Table S3 in the SI). Many of the studies have evaluated multiple medias or have evaluated the relative time to breakthrough for various PFAS. For example, Senevirathna et al. (2010b) compared the effectiveness of three nonionic resins, including DOW V493, Amb XAD 4, and Dow L493 with Calgon F400 GAC for PFOS removal with parallel pilot scale column experiments. Dow V493 reached 10% breakthrough first at 13,000 bed volumes (BVs), followed by F400 at 25,000 BVs. The two other resins outperformed the
GAC by reaching 10% breakthrough at 35,000 BVs (Dow L493) and 55,000 BVs (Amb XAD 4). Conte, Falletti, Zaggia, and Milan (2015) compared
AEX and nonionic resins and found AEX to perform better, and similarly to Zaggia et al. (2016), decreasing removal efficiency was seen with decreasing PFAS chain length. Chularueangaksorn et al. (2014) compared five types of AEX resins (PFA300, Dow Marathon A, IRA400, PFA400, and
PFA 444) with F400 GAC using parallel column tests similar to Senevirathna et al. (2010b). GAC reached 10% breakthrough first at 40 days, followed by the AEX resins in the order of FPA 444, PFA 400,
IRA 400, Dow Marathon A and PFA 300, with PFA 300 exhibiting less than 1% breakthrough until day 52. Woodard et al. (2017) also found AEX to outperform GAC, except for PFBA, which behaved similarly in each system. McCleaf et al. (2017) compared the removal of 14 PFAS using a pilotscale AEX column and a pilot scale GAC column. AEX resin had better removal efficiencies for longer chained PFAS compared to shorter chained ones and for PFSAs compared to PFCAs. The authors concluded that AEX had higher removal for PFNA, PFDA, perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), PFBS, PFHxS, PFOS and
PFHpA, and perfluorotetradecanoic acid (PFTeDA). Appleman et al. (2014) investigated PFAS removal at a full-scale water treatment plant in New Jersey using a strong base, porous AEX resin (Purolie FerrIX A33E) typically used for arsenic removal. Two sampling events occurred at 5 and 9 months of operation and similar to the observations from the pilot scale study by McCleaf et al. (2017), PFSAs and longer chain PFCAs had appreciable removal. Specifically, the resin demonstrated PFAS removals of more than 83% (PFBS), 97% (PFHxs), 90% (PFOS), 54% (PFHpA), and 76% 2378 B. C. CRONE ET AL. (PFOA). However, the resin lacked effectiveness in removing for shorter chain PFCAs, including PFBA, PFPeA and PFHxA. Appleman et al. (2014) also reported on a full-scale water treatment plant using magnetic AEX resins in an up-flow fluidized-bed contactor for DOC removal. This AEX system showed negligible removal (<10%) for all 14 PFAS monitored, and the authors suggested the continuous regeneration method (as opposed to a complete resin replacement) or improper operation as possible reasons for the poor performance. While AEX resins typically have higher capacities than GAC, several important limitations and knowledge gaps remain. Improvements in the removal of short-chain PFAS, most likely through the modification of the
AEX resin functional group is needed. Assessment of PFAS competition with background ions such as sulfate, nitrate, and bicarbonate, determination of selectivity coefficients, and further elucidation of NOM interactions will increase fundamental understanding of process mechanics and improve modeling predictions. Improvements in resin regeneration and handling of related waste streams could allow resins to be used multiple times and reduce environmental impact and cost. 5. Activated carbon treatment 5.1. Activated carbon treatment overview Activated carbon adsorption is used to remove natural organic compounds, taste and odor compounds, and synthetic organic compounds from drinking water (USEPA, 2018). Typically, either PAC is dosed early in the treatment train and removed through sedimentation, or GAC is used in fixed beds either in combination with filtration or as a post-filtration step (Chowdhury, 2013; USEPA, 2018). PAC generally has a diameter of less than 0.1 mm and GAC typically ranges from 1.2 to 1.6 mm in diameter (USEPA, 2018). Many types of activated carbon have been evaluated for
PFAS removal, including GAC, PAC, biochar, ash, carbon nanotubes, and carbon fibers (Chen, Xia, Wang, Qiao, & Chen, 2011; Chen, Zhang,
Mamadiev, & Wang, 2017; Dudley, Arevalo, & Knappe, 2015; Inyang &
Dickenson, 2017). Several activated carbon source materials have been evaluated as well, including bamboo, wood, coconut, and coal (Deng et al., 2015; Qiu, Fujii, & Tanaka, 2007; Xiao et al., 2017; Zhi & Liu, 2015). Several PFAS adsorption mechanisms have been identified, including multi-layer adsorption, micelle and hemi-micelle formation (Chen et al., 2017), acid base interactions, and the electrostatic and hydrophobic effects (Du et al., 2014; Zhi & Liu, 2015). Adsorption is primarily controlled by surface chemistry, and according to Zhi and Liu (2015), the best predictor of PFAS adsorption is surface basicity. This was further illustrated by Deng
CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY 2379 et al. (2015) when a potassium hydroxide activated bamboo was evaluated and found to outperform other GACs reported in the literature. Zhi and Liu (2016) reported an increase in capacity through high temperature and ammonia activation. The size used has been shown to significantly impact the PFAS adsorption capacity with PAC (<0.1 mm) having nearly double the capacity of GAC (0.9–1 mm) with the same specific surface area. While these results may be impacted by pore blockage and steric hinderance, they have significant implications for scaling since capacity is usually assumed to be independent of particle size (Crittenden, Berrigan, & Hand, 1986; Du et al., 2014). It is important to note that the dominant mechanism may be different for different PFAS. For instance, short chain PFAS are more hydrophilic than their long chain counterparts and may be repelled by the hydrophobic effect, which has been identified as a dominant mechanism of adsorption for longer-chain PFAS (Rahman et al., 2014). Perfluorinated sulfonates are considered “hard bases” and more hydrophobic than their carboxylic counterparts, making them easier to adsorb under conditions in drinking water treatment (Du et al., 2014). This was clearly demonstrated by OchoaHerrera and Sierra-Alvarez (2008) who reported a capacity of 57 mg
PFAS primarily exist as anions with a net negative charge and will be repelled by GAC when the pH is above the GAC’s point of zero charge (PZC), which is another weak but important predictor in PFAS adsorption (Deng et al., 2015; Zhi & Liu, 2015). Several studies have shown increased adsorption capacity at lower pH and at positive zeta potential values (Chen et al., 2017; Deng et al., 2015). More work is needed to differentiate the effects of lower pH on sorbent properties from changes in sorbates at lower pH values. The impact of pH becomes increasingly important in the presence of even small amounts of NOM which in one case was shown to reduce the pH of a GAC’s PZC from 7 to 2.2 because of the NOM’s negative charge (Inyang & Dickenson, 2017; Newcombe, Drikas, &
Hayes, 1997). Additionally, NOM and PFAS can have overlapping molecular structure, allowing them to directly interact both electrostatically (e.g., cation bridge effect) and through hydrophobic or hydrophilic forces (Inyang &
Dickenson, 2017). For example, in pre-equilibrium conditions, increasing
NOM and PFAS (Kothawala et al., 2017). Highest retention was observed when a more hydrophobic NOM was used. A more hydrophilic NOM led to reduced long chain retention, highlighting the importance of electrostatic 2380 B. C. CRONE ET AL. and hydrophobic forces and the variation that is possible based on overall net charge and PFAS hydrophobicity/hydrophilicity (Kothawala et al., 2017). Co-adsorption could also explain the increase in PFAS adsorption when simultaneously adsorbed with NOM compared to PFAS adsorption onto GAC preloaded with NOM (Hansen, Børresen, Schlabach, &
Cornelissen, 2010). These results coupled with other reports in the literature of NOM significantly reducing PFAS adsorption capacity indicate that
NOM-PFAS interactions are complex and may shift with time (Kothawala et al., 2017). Further work is needed to understand NOM-PFAS-GAC interactions throughout the adsorption process for optimization and application to different matrices and sorbents. Ionic strength can also have a significant impact on PFAS adsorption onto GAC, reducing solubility and ability to adsorb with increasing ionic strength. Carter and Farrell (2010) reported a 17-fold reduction in PFOS solubility when comparing ultrapure water with 100 mM sodium perchlorate electrolyte solution. Although the ionic strength value far exceeds expected ionic strengths in drinking water (low mM), impacts from a range of relevant concentrations on adsorption requires evaluation. One significant advantage of GAC over other treatment technologies is that it shows promise for reactivation with respect to PFAS. A study evaluating the reactivation of GAC containing PFOS, PFOA, and PFHxA at the bench scale reported destruction of PFAS adsorbed onto GAC at 700 C and complete destruction of the PFAS not adsorbed onto GAC at 1,000 C (Watanabe, Takemine, Yamamoto, Haga, & Takata, 2016). It was also noted that when regenerating between 800 and 900 C, some short-chain
PFAS escaped into the off-gas by volatile release before they could be destroyed, leading to the recommendation to heat the off-gas to 1,000 C to ensure complete mineralization of adsorbed and volatilized PFAS. Further work is needed to verify this result for a broader range of PFAS and in a full-scale reactivation facility. 5.2. Activated carbon batch studies Isotherms are used to evaluate the equilibrium adsorption capacity of specific sorbate and sorbent combinations to optimize adsorbent selection and predict CURs (Tchobanoglous, Burton, & Stensel, 2003). Reported isotherms evaluating PFAS adsorption onto GAC have primarily focused on
PFOS and PFOA at lg/L to mg/L concentration ranges (Carter & Farrell, 2010; Chen et al., 2011; 2017; Deng et al., 2015; Inyang & Dickenson, 2017; Kothawala et al., 2017; Ochoa-Herrera & Sierra-Alvarez, 2008; Qiu et al., 2007; Xiao et al., 2017; Yu et al., 2009; Zhang et al., 2016), but several studies have isotherm and kinetic data of additional PFAS at concentrations
PFOS PFOA PFOA PFOA PFOA PFOA PFOA Zhi and Liu (2015) Zhi and Liu (2016) Dudley et al. (2015) Zhi and Liu (2015) Deng et al. (2015) Zhang et al. (2016) Chen et al. (2017) Yu et al. (2009) Chularueangaksorn et al. (2014) Ochoa-Herrera and Sierra-Alvarez (2008) Zhi and Liu (2016)
APHA. (1989). Standard methods for the examination of water and wastewater.
P. (2013). Nanofiltration and granular activated carbon treatment of perfluoroalkyl acids. Journal of Hazardous
V. (2014). Treatment of poly- and perfluoroalkyl substances in U.S. full-scale water treatment systems. Water Research, 51, 246. doi:10.1016/ j.watres.2013.10.067
S. (2017). Use of granular activated carbon and carbon block filters at municipal and point of use drinking water treatment for removal of organics. Arizona State
E. (2005). Water treatment plant design. American Water Works Association and American Society of Civil Engineers. New York, NY: McGraw-Hill.
A. (2009). Evaluation of a photocatalytic reactor membrane pilot system for the removal of pharmaceuticals and endocrine disrupting compounds from water. Water Research, 43(6), 1513. doi:10.1016/ j.watres.2008.12.049
C. (2004). Detection of perfluorooctane surfactants in great lakes water. Environmental Science & Technology, 38(15), 4064. doi:10.1021/es0496975
Bowman, B. (1982). Conversion of freundlich adsorption K values to the mole fraction format and the use of SY values to express relative adsorption of pesticides 1. Soil Science Society of America Journal, 46(4), 740. doi:10.2136/sssaj1982.03615995004600040014x
P. (2011). Perfluoroalkyl and polyfluoroalkyl substances in the environment:
Busch, J., Ahrens, L., Sturm, R., & Ebinghaus, R. (2010). Polyfluoroalkyl compounds in landfill leachates. Environmental Pollution, 158(5), 1467. doi:10.1016/j.envpol.2009.12.031
Carter, K. E., & Farrell, J. (2010). Removal of perfluorooctane and perfluorobutane sulfonate from water via carbon adsorption and ion exchange. Separation Science and
Chen, W., Zhang, X., Mamadiev, M., & Wang, Z. (2017). Sorption of perfluorooctane sulfonate and perfluorooctanoate on polyacrylonitrile fiber-derived activated carbon fibers: In comparison with activated carbon. RSC Advances, 7(2), 927. doi:10.1039/C6RA25230C
Chen, X., Xia, X., Wang, X., Qiao, J., & Chen, H. (2011). A comparative study on sorption of perfluorooctane sulfonate (PFOS) by chars, ash and carbon nanotubes. Chemosphere, 83(10), 1313. doi:10.1016/j.chemosphere.2011.04.018
K. (2013). Activated carbon: Solutions for improving water quality. Denver,
Chularueangaksorn, P., Tanaka, S., Fujii, S., & Kunacheva, C. (2014). Batch and column adsorption of perfluorooctane sulfonate on anion exchange resins and granular activated carbon. Journal of Applied Polymer Science, 131(3), n/a. doi:10.1002/app.39782
Conte, L., Falletti, L., Zaggia, A., & Milan, M. (2015). Polyfluorinated organic micropollutants removal from water by ion exchange and adsorption. Chem Eng Trans, 43, 2257.
W. (1986). Design of rapid small-scale adsorption tests for a constant diffusivity. Journal (Water Pollution Control Federation), 312(4), 312–319.
Crittenden, J. C., Hand, D. W., Arora, H., & Lykins, B. W. Jr, (1987). Design considerations for GAC treatment of organic chemicals. Journal/American Water Works Association, 79(1), 74. doi:10.1002/j.1551-8833.1987.tb02786.x
Cummings, L., Matarazzo, A., Nelson, N., Sickels, F., & Storms, C. (2015). Recommendation on perfluorinated compound treatment options for drinking water. New Jersey Drinking Water Quality Institute Treatment Subcommittee Report.
Deng, S., Nie, Y., Du, Z., Huang, Q., Meng, P., Wang, B., … Yu, G. (2015). Enhanced adsorption of perfluorooctane sulfonate and perfluorooctanoate by bamboo-derived granular activated carbon. Journal of Hazardous Materials, 282, 150. doi:10.1016/j.jhazmat.2014.03.045
Deng, S., Yu, Q., Huang, J., & Yu, G. (2010). Removal of perfluorooctane sulfonate from wastewater by anion exchange resins: effects of resin properties and solution chemistry. Water Research, 44(18), 5188. doi:10.1016/j.watres.2010.06.038
Dickenson, E., & Higgins, C. (2016). Treatment mitigation strategies for poly- and perfluoroalkyl substances. Water Research Foundation Web Report, 4322.
Du, Z., Deng, S., Bei, Y., Huang, Q., Wang, B., Huang, J., & Yu, G. (2014). Adsorption behavior and mechanism of perfluorinated compounds on various adsorbents—A review. Journal of Hazardous Materials, 274, 443. doi:10.1016/j.jhazmat.2014.04.038