{"document":{"doc_id":183010,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Federal Register. Final Rule. U.S. Environmental Protection Agency. 1999. National Primary and Secondary Drinking Water Regulations: Analytical Methods for chemical and Microbiological Contaminants and Revisions to Laboratory Certification Requirements; Final Rule Wednesday, December 1, 1999, Volume 64, Number 230, Page 67449-67467,[W-00-12-II-A-2-2]","date":"2026-09-28","url":"https://www.regulations.gov/document/EPA-HQ-OW-2004-0040-0108","source_native_id":"EPA-HQ-OW-2004-0040-0108","status":"fetched","abstract":null,"action":null},"dockets":["EPA-HQ-OW-2004-0040"],"rins":["RIN 2040-AC98"],"related":[{"doc_id":21292,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Rule","title":"National Primary Drinking Water Regulations; Radionuclides; Final Rule","date":"2000-12-07"},{"doc_id":134808,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Form for Compliance with E.O. 12866 Docket Requirements [DCN II-D.1]","date":"2004-11-30"},{"doc_id":134809,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Attachment 2 to Form for Compliance with E.O. 12866 Docket Requirements.  Other Agency Changes Made to the Final Radionuclides Preamble and Rule [DCN II-D.3]","date":"2004-11-30"},{"doc_id":134810,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Attachment 1 to Form for Compliance with E.O. 12866 Docket Requirements; Changes Made to the Final Radionuclides Rule as a result of OMB Review [DCN II-D.2]","date":"2004-11-30"},{"doc_id":272435,"source":"docket_item","org":"EPA","doc_type":"report","title":"Radionuclides Notice of Data Availability\r\nTechnical Support Document [DCN II-B.24 Part 1 of 2]","date":"2004-11-30"},{"doc_id":272436,"source":"docket_item","org":"EPA","doc_type":"report","title":"Radionuclides Notice of Data Availability\r\nTechnical Support Document [DCN II-B.24 Part 2 of 2]","date":"2004-11-30"},{"doc_id":169158,"source":"docket_item","org":"EPA","doc_type":"other","title":"Legacy Index for Docket W-00-12","date":"2025-04-17"},{"doc_id":127286,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Form for Compliance with E.O. 12866 Docket Requirements [W-00-12-I-H-1]","date":"2026-09-28"},{"doc_id":162420,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to David Huber, Edwin Thomas, OGWDW from Scott Telofski, ORIA regarding Uranium Analysis Screening Level for Drinking Water Regulations NODA. March 14, 2000 [W-00-12-I-B-17]","date":"2026-09-28"},{"doc_id":162421,"source":"docket_item","org":"EPA","doc_type":"report","title":"Szabo, Z., V.T. dePaul, and B. Parsa, 1998. Decrease in gross alpha-particle activity in water samples with time after collection from the Kirkwood Cohansy aquifer system in southern New Jersey: Implications for regulations. Drinking Water 63rd annual meeting American Water Works Association New Jersey Section. Atlantic City, NJ [W-00-12-I-C-4]","date":"2026-09-28"},{"doc_id":162424,"source":"docket_item","org":"EPA","doc_type":"report","title":"Regional Variation of the Cost of Drinking Water Wells for Public Water Supplies”. Prepared by Cadmus for the Office of Ground Water and Drinking Water. Draft. October 1999 [W-00-12-I-G-8]","date":"2026-09-28"},{"doc_id":162427,"source":"docket_item","org":"EPA","doc_type":"report","title":"Small System Compliance Technology List for the Radionuclides Rule. Prepared by International Consultants, Inc. Draft. April 1999[W-00-12-I-F-10]","date":"2026-09-28"},{"doc_id":162428,"source":"docket_item","org":"EPA","doc_type":"data","title":"USEPA. Results from survey of compliance actions taken in the State of Illinois in response to the NPDWR for combined radium. Submitted from EPA Region 5. 1998. (EPA 1998c).[W-00-12-I-G-6]","date":"2026-09-28"},{"doc_id":162431,"source":"docket_item","org":"EPA","doc_type":"data","title":"U.S. Geological Survey (USGS)  Radium-226 and Radium-228 in a Shallow Ground\nWater, Southern New Jersey. Fact Sheet FS-062-98.[W-00-12-I-B-19]","date":"2026-09-28"},{"doc_id":162432,"source":"docket_item","org":"EPA","doc_type":"report","title":"Preliminary Health Risk Reduction and Cost Analysis: Revised National Primary Drinking Water Standards for Radionuclides”. Prepared by Industrial Economics, Inc. for EPA. Draft. January 2000. EPA 815-R-00-008. (EPA 2000b).\n184 pp. Also available at the Water Resource Center (limited quantities).[W-00-12-I-B-16]","date":"2026-09-28"},{"doc_id":162434,"source":"docket_item","org":"EPA","doc_type":"report","title":"Technical Support Document for the Radionuclides Notice of Data\nAvailability. Draft. March, 2000. EPA 815-R-00-007. (EPA 2000a). 205 pp. Also available at the Water Resources Center (limited quantities).[W-00-12-I-B-15]","date":"2026-09-28"},{"doc_id":162435,"source":"docket_item","org":"EPA","doc_type":"report","title":"Technologies and Costs for the Removal of Radionuclides from Potable Water Supplies. Draft. Prepared by International Consultants, Inc. April, 1999 [W-00-12-I-F-9]","date":"2026-09-28"},{"doc_id":182994,"source":"docket_item","org":"EPA","doc_type":"publication","title":"National Primary Drinking Water Regulation: Consumer Confidence Reports; Final Rule, 63 FR 44511, August 19, 1998. [W-00-12-II-B-10]","date":"2026-09-28"},{"doc_id":182997,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Federal Register. Final Rule. U.S. Environmental Protection Agency. 1998. Removal of the Prohibition on the Use of Point of Use Devices for Compliance with National Primary Drinking Water Regulations. Final Rule. Thursday, June 11, 1998 Volume 63, Number 112, Page 31932-31934 [W-00-12-II-A-2-1]","date":"2026-09-28"},{"doc_id":182999,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Announcement of Small Systems Compliance Technology Lists for Existing National Primary Drinking Water Regulations and Findings Concerning Variance Technologies. Federal Register. Vol. 63, No. 151, p. 42032. August 6, 1998[W-00-12-I-F-6]","date":"2026-09-28"},{"doc_id":183000,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Szabo, Z., and O.S. Zapecza, 1991, Geologic and geochemical factors controlling uranium, radium-226, and radon-222 in ground water, Newark Basin, New Jersey: Gundersen, L.C.S. and Wanty, R.B., eds., Field studies of radon in rocks, soils, and water, U.S. Geological Survey Bulleting 1971, [W-00-12-I-C-5]","date":"2026-09-28"},{"doc_id":183004,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Performance Based Measurement System. Federal Register. Vol. 62, No. 193, p. 52098. October 6, 1997. [W-00-12-I-B-8]","date":"2026-09-28"},{"doc_id":183005,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Presumptive Response Strategy and Ex-Situ Treatment Technologies for Contaminated Ground Water at CERCLA Sites: Final Guidance. EPA 540/R-96/023. October 1996.\n(EPA 1996a). [W-00-12-I-B-4]","date":"2026-09-28"},{"doc_id":183006,"source":"docket_item","org":"EPA","doc_type":"publication","title":"National Primary Drinking Water Regulations: Consumer\nConfidence; Proposed Rule. Friday, February 13, 1998. Volume 63, Number 30, Page [W-00-12-II-B-9]","date":"2026-09-28"},{"doc_id":183014,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Zapecza, O. S., and Z. Szabo, 1986. Natural radioactivity in ground water- a review. U.S. Geological Survey National Water Summary 1986, Ground-Water Quality:\nHydrologic Conditions and Events, U. S. Geological Survey Water Supply Paper 2325 [W-00-12-I-C-9]","date":"2026-09-28"},{"doc_id":183018,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Cancer Risk Coefficients for Environmental Exposure to Radionuclides, Federal Guidance Report No. 13. US Environmental Protection Agency, Washington,\nDC, 1999. (EPA 1999b). EPA 402-R-99-001, September 1999 [W-00-12-I-B-14]","date":"2026-09-28"},{"doc_id":183019,"source":"docket_item","org":"EPA","doc_type":"publication","title":"National Primary Drinking Water Regulations; Radionuclides, Notice of Data Availability; Proposed Rule, Friday, April 2l, 2000. 65 FR 21577-21628. EPA 815-2-00-003. [W-00-12-II-B-21]","date":"2026-09-28"},{"doc_id":209803,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Office of Solid Waste and Emergency Response (OSWER). 1997.\nMemorandum from Timothy Fields to Regional Administrators. “The Role of\nCSGWPP’s in EPA Remediation Programs”. OSWER No. 9283.1-09. April 4, 1997 [W-00-12-I-B-12]","date":"2026-09-28"},{"doc_id":209804,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Office of Solid Waste and Emergency Response (OSWER). 1997. Memorandum from Stephen Luftig and Larry Weinstock (Office of Radiation and Indoor Air) to Addressees. “Establishment of Cleanup Levels for CERCLA Sites with Radioactive Contamination”. OSWER No. 9200.4-18. August 22, 1997[W-00-12-I-B-11]","date":"2026-09-28"},{"doc_id":209805,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to David Huber, Edwin Thomas, OGWDW from Scott Telofski, ORIA regarding Gross Alpha Screening for Uranium. March 20, 2000. (EPA 2000d). [W-00-12-I-B-18]","date":"2026-09-28"},{"doc_id":209806,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum from Administrator Carol M. Browner of EPA to Chairperson Shirley A. Jackson of the Nuclear Regulatory Commission. February 7, 1997. [W-00-12-I-B-10]","date":"2026-09-28"},{"doc_id":209809,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum to Water Management Division Directors, Regions I-X from Cynthia C. Dougherty, Director, Office of Ground Water and Drinking Water regarding Recommendations Concerning Testing for Gross Alpha Emitters in Drinking Water (January 27, 1999) [W-00-12-I-B-13]","date":"2026-09-28"},{"doc_id":198636,"source":"docket_item","org":"EPA","doc_type":"other","title":"Delivery Receipts from U.S. Environmental Protection Agency to The Honorable Albert Gore President of the Senate, The Capitol, S-212 et al. [W-00-12-II-E-1]","date":"2026-10-01"}],"references":[{"citation_id":1587435,"raw_reference":"EPA proposed approving the use of updated versions of previously approved analytical methods, the withdrawal of older versions of certain EPA methods, minor technical corrections or clarifications, and amendments to the regulations. The direct final rule, in the absence of adverse public comment, would have been final on January 4, 1999. Because adverse comments were received, EPA withdrew the entire September 1998 rule on December 31, 1998 (63 FR 72200) and deferred final action in order to respond to those comments.","cited_authors":"EPA proposed approving the use of updated versions of previously approved analytical methods, the withdrawal of older versions of certain EPA methods, minor technical corrections or clarifications, and amendments to the regulations. The direct final rule, in the absence of adverse public comment, would have been final on January 4","cited_year":"1999","cited_title":"Because adverse comments were received, EPA withdrew the entire September 1998 rule on December 31, 1998 (63 FR 72200) and deferred final action in order to respond to those comments","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587436,"raw_reference":"Therefore, the pH adjustment step was removed and the method was reissued and proposed as EPA Method 549.2. The pH retest step and other data are in the administrative record of the July 31, 1998 (63 FR National Primary and Secondary Drinking W... to Laboratory Certification Requirementhttp://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm 41134) rule. Use of EPA Method 549.2 does not require re-certification or learning the use of a new method. EPA Method 549.2 is EPA Method 549.1 without the pH adjustment step. Requiring a step (pH adjustment) to be omitted from the current method does not impose a hardship on analytical laboratories or the regulated community. As no positive effect is associated with the pH adjustment to 10.5, and there is the possibility of a negative effect, the Agency is withdrawing EPA Method 549.1.","cited_authors":null,"cited_year":null,"cited_title":"Therefore, the pH adjustment step was removed and the method was reissued and proposed as EPA Method 549.2","cited_venue":null,"cited_doi":null,"cited_url":"http://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587437,"raw_reference":"3. MI-Agar Medium for Coliform Determinations In the July 31, 1998 rule, EPA proposed to approve the use of MI Agar for use with the Total Coliform Rule and Surface Water Treatment Rule. The Agency had proposed that the results from MI Agar can be read following incubation of media for 16-24 hours. Two commenters suggested that the MI Agar procedure should be approved as a 24 hour procedure since results in the comparison study were read at 24 hours. EPA data demonstrates that blue E. coli and fluorescent total coliform colonies appear in as few as 9 hours, which would be detected by the laboratory in 16-24 hours, depending upon the time of day the sample was filtered.","cited_authors":null,"cited_year":null,"cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"news","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587438,"raw_reference":"However, because the appearance time for the blue E. coli colonies exceeded the standard 8-hour working day and because EPA planned to compare the MI Agar procedure with one using M-Endo medium, a 24-hour method, EPA used the 24-hour incubation time for the studies. Thus, the Agency is approving the method as a 24-hour test (although the test may be recorded as positive if this result shows up earlier than 24 hours). The test is approved for detecting total coliforms and E. coli under the Total Coliform Rule and for enumerating total coliforms under the Surface Water Treatment Rule. B. Responses to Significant Comments Received on the September 3, 1998 (63 FR 47115) Notice 1. Quality Control Improvements for EPA Methods Four commenters on the September 1998 rule noted that, although many Supplement III methods contain tightened analyte recovery control limits of 30%, the data presented in some of these methods do not support the change. Commenters provided data or other information to support their argument for the following analytes: 2,4DB, Aciflurofen, DCPA, Dinoseb, pentachlorophenol and Picloram in EPA Method 515.1, Rev. 4.1; hexachlorocyclopentadiene (HCP) in EPA Method 508.1, Rev. 2.0; and DDT in EPA Method 508, Rev.3.1. The commenters recommended either (1) retaining the current limits of 3 standard deviations or method limits, whichever are narrower for these three methods or (2) setting the recovery control limits on an analyteby-analyte basis.","cited_authors":null,"cited_year":null,"cited_title":"However, because the appearance time for the blue E. coli colonies exceeded the standard 8-hour working day and because EPA planned to compare the MI Agar procedure with one using M-Endo medium, a 24-hour method, EPA used the 24-hour incubation time for the studies","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587439,"raw_reference":"APHA 1992. Eighteenth edition of Standard Methods for the Examination of Water and Wastewater, 1992, American Public Health","cited_authors":"APHA","cited_year":"1992","cited_title":"Eighteenth edition of Standard Methods for the Examination of Water and Wastewater, 1992, American Public Health","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587440,"raw_reference":"APHA 1995. Nineteenth edition of Standard Methods for the Examination of Water and Wastewater, 1995, American Public Health","cited_authors":"APHA","cited_year":"1995","cited_title":"Nineteenth edition of Standard Methods for the Examination of Water and Wastewater, 1995, American Public Health","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587441,"raw_reference":"ASTM 1994. Annual Book of ASTM Standards, 1994, Vol. 11.01 and 11.02, American Society for Testing and Materials, 100 Barr Harbor","cited_authors":"ASTM","cited_year":"1994","cited_title":"Annual Book of ASTM Standards, 1994, Vol","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587442,"raw_reference":"Drive, West Conshohocken, PA 19428. ASTM 1996. Annual Book of ASTM Standards, 1996, Vol. 11.01 and 11.02, American Society for Testing and Materials, 100 Barr Harbor","cited_authors":"Drive, West Conshohocken, PA 19428. ASTM","cited_year":"1996","cited_title":"Annual Book of ASTM Standards, 1996, Vol","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587443,"raw_reference":"Drive, West Conshohocken, PA 19428. AWWA 1996. \"\"Standard Methods—A Closer Look'1, Posavec, Steve, in","cited_authors":"Drive, West Conshohocken, PA 19428. AWWA","cited_year":"1996","cited_title":"\"\"Standard Methods—A Closer Look'1, Posavec, Steve, in","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587444,"raw_reference":"Opflow, Vol. 22, No. 2, February 1996, American Water Works","cited_authors":"Opflow, Vol. 22, No. 2, February","cited_year":"1996","cited_title":"American Water Works","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587445,"raw_reference":"Association, 6666 West Quincy Avenue, Denver, CO 80235. Brenner 1993. Brenner, K.P., et al., \"\"New medium for the simultaneous detection of total coliform and Escherichia coli in water 1 ', Appl. Environ. Microbiol. 59:3534-3544. Brenner 1996a. Brenner, K.P., et al., \"\"Comparison of the recoveries of Escherichia coli and total coliform from drinking water by the MI Agar method'', Appl. Environ. Microbiol. 62:203-208. Brenner 1996b. Brenner, K.P., et al., \"\"Interlaboratory evaluation of MI Agar and the U.S. Environmental Protection Agency—approved membrane filter method for the recovery of total coliform and Escherichia coli from drinking water' 1 , J. Microbiol. Methods 27:111119.","cited_authors":"Association, 6666 West Quincy Avenue, Denver, CO 80235. Brenner","cited_year":"1993","cited_title":"\"New medium for the simultaneous detection of total coliform and Escherichia coli in water 1 ', Appl. Environ. Microbiol. 59:3534-3544. Brenner 1996a. Brenner, K.P., et al","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587446,"raw_reference":"EPA 1987. \"\"Development of Preservation Techniques and Establishment of Maximum Holding Times: Inorganic Constituents of the National Pollutant Discharge Elimination System and Safe Drinking Water Act 1 ', EPA/600/S4-86/043, March 1987.","cited_authors":"EPA","cited_year":"1987","cited_title":"\"\"Development of Preservation Techniques and Establishment of Maximum Holding Times: Inorganic Constituents of the National Pollutant Discharge Elimination System and Safe Drinking Water Act 1 ', EPA/600/S4-86/043, March 1987","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587447,"raw_reference":"EPA 1990a. \"\"Methods for the Determination of Organic Compounds in Drinking Water—Supplement I'', July 1990, NTIS PB91-146027.","cited_authors":"EPA","cited_year":"1990a","cited_title":"\"\"Methods for the Determination of Organic Compounds in Drinking Water—Supplement I'', July 1990, NTIS PB91-146027","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587448,"raw_reference":"EPA 1991. \"\"Methods for the Determination of Organic Compounds in P.23 National Primary and Secondary Drinking W... to Laboratory Certification Requiremen_sttp://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm Drinking Water'', December 1988, revised July 1991, NTIS PB91-231480.","cited_authors":"EPA","cited_year":"1991","cited_title":"\"\"Methods for the Determination of Organic Compounds in P.23 National Primary and Secondary Drinking W... to Laboratory Certification Requiremen_sttp://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm Drinking Water'', December 1988, revised July 1991, NTIS PB91-231480","cited_venue":null,"cited_doi":null,"cited_url":"www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587449,"raw_reference":"EPA 1992. \"\"Methods for the Determination of Organic Compounds in Drinking Water—Supplement II, ' • August 1992, NTIS PB92-207703.","cited_authors":"EPA","cited_year":"1992","cited_title":"\"\"Methods for the Determination of Organic Compounds in Drinking Water—Supplement II, ' • August 1992, NTIS PB92-207703","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587450,"raw_reference":"EPA 1993. \"\"Methods for the Determination of Inorganic Substances in Environmental Samples'', August 1993, NTIS PB94-120821.","cited_authors":"EPA","cited_year":"1993","cited_title":"\"\"Methods for the Determination of Inorganic Substances in Environmental Samples'', August 1993, NTIS PB94-120821","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587451,"raw_reference":"EPA 1994. \"\"Methods for the Determination of Metals in Environmental Samples—Supplement I'', May 1994, NTIS PB95-125472.","cited_authors":"EPA","cited_year":"1994","cited_title":"\"\"Methods for the Determination of Metals in Environmental Samples—Supplement I'', May 1994, NTIS PB95-125472","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587452,"raw_reference":"EPA 1994b. Technical Notes on Drinking Water Methods, EPA/600/R-94/ 173, October 1994, NTIS PB95-104766.","cited_authors":"EPA","cited_year":"1994b","cited_title":"Technical Notes on Drinking Water Methods, EPA/600/R-94/ 173, October 1994, NTIS PB95-104766","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587453,"raw_reference":"EPA 1995. \"\"Methods for the Determination of Organic Compounds in Drinking Water—Supplement III, '' EPA/600/R-95/131, August 1995, NTIS PB95-261616.","cited_authors":"EPA","cited_year":"1995","cited_title":"\"\"Methods for the Determination of Organic Compounds in Drinking Water—Supplement III, '' EPA/600/R-95/131, August 1995, NTIS PB95-261616","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587454,"raw_reference":"EPA 1996. EPA Methods 515.3, \"\"Determination of Chlorinated Acids in Drinking Water by Liquid-liquid Extraction, Derivatization And Gas Chromatography With Electron Capture Detection,'' Revision 1.0, EPA/ 815/B-99/001, July 1996. Available from U.S. Environmental Protection","cited_authors":"EPA","cited_year":"1996","cited_title":"EPA Methods 515.3, \"\"Determination of Chlorinated Acids in Drinking Water by Liquid-liquid Extraction, Derivatization And Gas Chromatography With Electron Capture Detection,'' Revision 1.0, EPA/ 815/B-99/001, July 1996","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587455,"raw_reference":"EPA 1997a. EPA Methods 549.2 \"\"Determination of Diquat And Paraquat in Drinking Water by Liquid-solid Extraction And High Performance Liquid Chromatography With Ultraviolet Detection'1, Revision 1.0, EPA/ 815/B-99/002, June 1997. Available from U.S. Environmental Protection","cited_authors":"EPA","cited_year":"1997a","cited_title":"EPA Methods 549.2 \"\"Determination of Diquat And Paraquat in Drinking Water by Liquid-solid Extraction And High Performance Liquid Chromatography With Ultraviolet Detection'1, Revision 1.0, EPA/ 815/B-99/002, June 1997","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587456,"raw_reference":"EPA 1997b. Manual for the Certification of Laboratories Analyzing Drinking Water, Fourth Edition, Office of Water Resource Center (RC4100), 401 M. Street SW, Washington, D.C. 20460, EPA/81/B-97/001, March 1997.","cited_authors":"EPA","cited_year":"1997b","cited_title":"Manual for the Certification of Laboratories Analyzing Drinking Water, Fourth Edition, Office of Water Resource Center (RC4100), 401 M. Street SW, Washington, D.C. 20460, EPA/81/B-97/001, March 1997","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587457,"raw_reference":"NY 1996. Suffolk County Water Authority 1996. Data Package pertaining to EPA Method 508.1 and the use of a NP detector. Suffolk County Water Authority Laboratory, 260 Motor Parkway, P.O. Box 18043,","cited_authors":"NY","cited_year":"1996","cited_title":"Suffolk County Water Authority 1996","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587458,"raw_reference":"Hauppauge, New York 11788-8843. Palintest 1999. Method 1001: Lead in Drinking Water by Differential Pulse Anodic Stripping Voltammetry, August 1999. Palintest, LTD, 21 Kenton Lands Road, P.O. Box 18395, Erlanger, KY 41018.","cited_authors":"Hauppauge, New York 11788-8843. Palintest","cited_year":"1999","cited_title":"Method 1001: Lead in Drinking Water by Differential Pulse Anodic Stripping Voltammetry, August 1999","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587459,"raw_reference":"USGS 1989. Methods 1-3720-85, 1-3300-85, 1-1030-85, 1-1601-85, I2598-85, 1-1700-85 and 1-2700-85 in Techniques of Water Resources Investigations of the U.S. Geological Survey, Book 5, Chapter A-1, 3rd ed., 1989, U.S. Geological Survey (USGS) Information Services, Box 25286, Federal Center, Denver, CO 80225-0425.","cited_authors":"USGS","cited_year":"1989","cited_title":"Methods 1-3720-85, 1-3300-85, 1-1030-85, 1-1601-85, I2598-85, 1-1700-85 and 1-2700-85 in Techniques of Water Resources Investigations of the U.S. Geological Survey, Book 5, Chapter A-1, 3rd ed., 1989, U.S. Geological Survey (USGS) Information Services, Box 25286, Federal Center, Denver, CO 80225-0425","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587460,"raw_reference":"USGS 1993. Method 1-2601-90 in Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory—Determination of Inorganic and Organic Constituents in Water and Fluvial Sediments, Open File Report 93-125, 1993, U.S. Geological Survey (USGS) Information","cited_authors":"USGS","cited_year":"1993","cited_title":"Method 1-2601-90 in Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory—Determination of Inorganic and Organic Constituents in Water and Fluvial Sediments, Open File Report 93-125, 1993, U.S. Geological Survey (USGS) Information","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587461,"raw_reference":"Services, Box 25286, Federal Center, Denver, CO 80225-0425. Williams 1979. Williams, T. J, et al., \"\"An Evaluation of the Need for Preserving Potable Water Samples for Nitrate Testing'1, JAWWA, March 1979, pp. 157-160. List of Subjects 40 CFR Part 141 Environmental protection, Chemicals, Incorporation by reference,","cited_authors":"Services, Box 25286, Federal Center, Denver, CO 80225-0425. Williams","cited_year":"1979","cited_title":"Williams, T. J, et al., \"\"An Evaluation of the Need for Preserving Potable Water Samples for Nitrate Testing'1, JAWWA, March 1979, pp","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587462,"raw_reference":"Indian-lands, Water supply. Dated: November 22, 1999.","cited_authors":"Indian-lands, Water supply. Dated: November 22","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587463,"raw_reference":"Carol M. Browner, Administrator. P.24 National Primary and Secondary Drinking W... to Laboratory Certification Requirementbttp://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm For the reasons set out in the preamble, title 40, chapter I of Code of Federal Regulations, are amended as follows: [[Page 67461]]","cited_authors":null,"cited_year":null,"cited_title":"Carol M. Browner, Administrator","cited_venue":null,"cited_doi":null,"cited_url":"www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587464,"raw_reference":"Street, SW, Washington, D.C. 20460 (Telephone: 202-260-3027); or at the Office of Federal Register, 800 North Capitol Street, NW, Suite 700, Washington, D.C. 20408. \\1\\ Methods 9221 A, B; 9222 A, B, C; 9221 D and 9223 are contained in Standard Methods for the Examination of Water and Wastewater, 18th edition (1992) and 19th edition (1995) American Public Health","cited_authors":"Street, SW, Washington, D.C. 20460 (Telephone: 202-260-3027); or at the Office of Federal Register, 800 North Capitol Street, NW, Suite 700, Washington, D.C. 20408. \\1\\ Methods 9221 A, B; 9222 A, B, C; 9221 D and 9223 are contained in Standard Methods for the Examination of Water and Wastewater, 18th edition","cited_year":"1992","cited_title":"and 19th edition (1995) American Public Health","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1587465,"raw_reference":"Association, 1015 Fifteenth Street NW, Washington, D.C. 20005; either edition may be used. P.25 National Primary and Secondary Drinking W... to Laboratory Certification Requiremenlhttp://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm \\2\\ The time from sample collection to initiation of analysis may not exceed 30 hours. Systems are encouraged but not required to hold samples below 10 deg.C during transit. \\3\\ Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the system conducts at least 25 parallel tests between this medium and lauryl tryptose broth using the water normally tested, and this comparison demonstrates that the falsepositive rate and false-negative rate for total coliform, using lactose broth, is less than 10 percent. \\4\\ If inverted tubes are used to detect gas production, the media should cover these tubes at least one-half to two-thirds after the sample is added. \\5\\ No requirement exists to run the completed phase on 10 percent of all total coliform-positive confirmed tubes. \\6\\ MI agar also may be used. Preparation and use of MI agar is set forth in the article, \"\"New medium for the simultaneous detection of total coliform and Escherichia coli in water'1 by Brenner, K.P., et al., 1993, Appl. Environ. Microbiol. 59:3534-3544. Also available from the Office of Water Resource Center (RC-4100), 401 M. Street SW,","cited_authors":"Association, 1015 Fifteenth Street NW, Washington, D.C. 20005; either edition may be used. P.25 National Primary and Secondary Drinking W... to Laboratory Certification Requiremenlhttp://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm \\2\\ The time from sample collection to initiation of analysis may not exceed 30 hours. Systems are encouraged but not required to hold samples below 10 deg.C during transit. \\3\\ Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the system conducts at least 25 parallel tests between this medium and lauryl tryptose broth using the water normally tested, and this comparison demonstrates that the falsepositive rate and false-negative rate for total coliform, using lactose broth, is less than 10 percent. \\4\\ If inverted tubes are used to detect gas production, the media should cover these tubes at least one-half to two-thirds after the sample is added. \\5\\ No requirement exists to run the completed phase on 10 percent of all total coliform-positive confirmed tubes. \\6\\ MI agar also may be used. Preparation and use of MI agar is set forth in the article, \"\"New medium for the simultaneous detection of total coliform and Escherichia coli in water'1 by Brenner, K.P., et al","cited_year":"1993","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.epa.gov/fedrgstr/EPA-WATER/1999/December/Day-01/w30901.htm","ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}