Reeves, M., G.A. Freeze, V.A: Kelley, J.F. Pickens, D.T. Upton, and P.B. Davies, 1991. Regional Double-Porosity Solute Transport in the Culebra Dolomite under Brine-ReservoirBreach Conditions: An Analysis of Parameter Sensitivity and Importance. SAND89-7069. Sandia National Laboratories: Albuquerque, N.M. Exceptional Service in the National Interest P.97 Copy To: Peter Swift Lori Dotson Kurt Larson Rip Anderson Jon Helton Palmer Vaughn Peter Davies Al Lappin
MS 1324 MS 1324 Exceptional Service in the National Interest vc*' P.98 o<£p/^>^ V-i-l-lP •The University of New Mexico New Mexico Engineering Research Institute Albuquerque. iS'.M S7131-1376 Date: 1 April 1996 M. S. Tierney, 6741, MS 1328 From: / / J . W. B«frgfdj?d, 6749 UNM/NMERI272 7228 Subject: Parameters required for the CUTTINGS.S code for use in WIPP Performance Assessment The use of the CUTTINGS.S code in the 1996 CCA performance assessment calculations requires that a number of parameters be added to the WIPP parameter database. Some of these parameters are new and others are modifications to existing values. Values for these parameters are stated below (when available) along with a bibliographic reference (attached).. IDMTRL and IDPRAM names are also suggested. -BLOWOUT:SUFTEN 8.0E-2 Surface tension of brine (N/m) Handbook of Chemistry and Physics, 49th Edition, R.C. Weast, Editor, The Chemical Rubber Company, Cleveland Ohio,; 1968, Page F-28. *-BLOWOUT:FGE 18.4 Gravity scaling factor (unitless) Draft Blowout Experiments using Fine Grained Silica Sands in an Axisymmetric
Geometry, Lary R. Lenke, Jerry W. Berglund, and Robert A. Cole, Contractor Report 1996/7/32250, New Mexico Engineering Research Institute, University of New Mexico, March 1996, p27. »BLOWOUT:FSE 00.0 Gravity scaling factor (unitless) Draft Blowout Experiments using Fine Grained Silica Sands in an Axisymmetric
Geometry, Lary R. Lenke, Jerry W. Berglund, and Robert A. Cole, Contractor Report 1996/7/32250, New Mexico Engineering Research Institute, University of New Mexico, March 1996, p27. . BLOWOUTrKGAS 1.41 Ratio of Specific Heats for Hydrogen (unitless)
Thermodynamics, E.F. Obert, McGraw- Hill, New York 1948, Table VI page 541. 5 w ^ - \.^.vl. • '• 9i7D*QP*-. i/oM-HPonrpe^Cil. i-BLOWOUT:APORO 1.7E-13 Waste permeability (m2) Qap 9-2 Documentation ofthe Overall Waste Permeability and Flow Property Values for the CCA. Memorandum to M.S. Tierney from B. M. Butcher January 29,1996 •SOREHOLE:Ll 182.88 Collar Length (ra) standard practices (20 collars 30 feet long=600 feet) Memorandum to Dr Jerry Berglund. NMERI from John P Marquis, Senior Research Engineer
NMERI, Summary of Gas/Oil Well DriU Collar Size Survey, September 22,1995, Table 3. -^BOREHOLE:L2 472.12 Drill pipe length whenrepositorypenetrated (m) Based on collar length and depth of repository (655m) Sandia WIPP Project 1991 Preliminary Comparison with 40 CFR Part 191, Subpart Bfor the Waste Isolation Pilot Plant, December 1991 \ Volume 3: Reference Data, Sandia Report SAND91-0893/3, Albuquerque NM, Sandia National Laboratories, p 1-38.
NMERI, Summary of Gas/Oil Well DriU Collar Size Survey, September 22,1995, Table 4. •30REHOLE:COLDIA 0.2032004 Collar diameter (m) Memorandum to Dr Jerry Berglund. NMERIfromJohn P Marquis, Senior Research Engineer
NMERI, Summary of Gas/Oil Well Drill Collar Size Survey, September 22,1995, Table 4. -BOREHOLE:PIPED 0.1143002 DriU pipe diameter (m) Memorandum to Dr Jerry Berglund. NMERIfromJohn P Marquis, Senior Research Engineer
NMERI, Summary of Gas/Oil Well Drill Collar Size Survey, September 22,1995, Tables 1, 2,3. .-BOREHOLErROUGHP 0.08 Friction factor (unidess) for very rough pipe
Streeter, V.L., 1958, Fluid Mechanics, McGraw-Hill, New York, Fig 4-33, p 183 •WASTREFrTAUFAIL 0.05 -10. Effective shearresistanceto erosion (Pa) to be sampled (uniform) Partheniades, E, and R.E. Paaswell, 1970. "Erodibility of Channels with Cohesive Boundary," Joumal ofthe Hydraulics Division, Proceedings ofthe American Society of Civil Engineers. Vol. 96, no. HY3,755-771.
INV.ARea 111520. The area of the repository (ra5) Sandia WIPP Project 1991 Preliminary Comparison with 40 CFR Part 191, Subpart Bfor the Waste Isolation Pilot Plant, December 1991 \ Volume 3: Reference Data, Sandia Report SAND91-0893/3, Albuquerque NM, Sandia National Laboratories, Table 3.1-1. p3-5 Plan area of RH waste ???? •^BLOWOUT.-RGAS 4116.0 Gas Constant for Hydrogen (Nm/kg/°K)
Thermodynamics, E.F. Obert, McGraw- Hill, New York 1948, Table VI page 541. Based on unit conversion from 766.53 (ftlb/lb^R) •-BLOWOUT:VISC 0.92 E-5 Hydrogen viscosity (Pas) Sandia WIPP Project 1992 Preliminary Performance Assessmentfor the Waste Isolation Pilot
Plant, December 1992, Volume 3: Model Parameters, Sandia Report SAND92-0700/3,
Albuquerque NM, Sandia National Laboratories, Table 4.1-1 page 4-1. i>BLOWOUT:PSUF 0.089465 E6 Surface atmospheric pressure (Pa) at elevation 1039 m. Sandia WLPP Project 1992 Preliminary Performance Assessmentfor the Waste Isolation Pilot
McDonald, John Wiley and Sons, New York, 1973, Table A.4 Page 584. ^BLOWOUT:TREPO 300.0? Temperature ofrepositoryCK) "BLOWOUT:INPORO 0.849 ? Initial repository porosity, (unitless) normally read from the BRAGFLO CDB file default if BRAGFLO CDBfilenot read ;.'BLOWOUT:HREPO 3.96 Height of repository at burial time (m) Sandia WIPP Project 1991 Preliminary Comparison with 40 CFR Part 191, Subpart Bfor the Waste Isolation Pilot Plant, December 1991 \ Volume 3: Reference Data, Sandia Report SAND91-0893/3, Albuquerque NM, Sandia National Laboratories, Figure 2.2-3 page 2-8. *. BLOWOUT:RPANEL 60.87 The equivalent radius of 1 panel (m) B ased on panel area of 11640 m2' Sandia WIPP Project 1991 Preliminary Comparison with 40 CFR Part 191, Subpart Bfor ihe Waste Isolation Pilot Plant, December 1991 \ Volume 3: Reference Data, Sandia Report SAND91-0893/3, Albuquerque NM, Sandia National Laboratories, Table 3.1-1, page 3-5. ;/B'LOWOUT:ROOM 17.1 The equivalent radius of 1 room (m) Based on room area of 919.7 m2 Sandia WIPP Project 1991 Preliminary Comparison with 40 CFR Part 191,.Subpart Bfor the Waste Isolation Pilot Plant, December 1991 \ Volume 3: Reference Data, Sandia Report SAND91-0893/3, Albuquerque NM, Sandia National Laboratories, Table 3.1-1, page 3-5. vBLOWOUT:RHOS 2650.0 Waste particle density (kg/m3) Draft Blowout Experiments using Fine Grained Silica Sands in an Axisymmetric
Geometry, Lary R. Lenke, Jerry W. Berglund, and Robert A. Cole, Contractor Report 1996/7/32250, New Mexico Engineering Research Institute, University of New Mexico, March 1996, pl8. _ LOWOUT:PARTDIA 0.000040 - 0.20 Waste particle diameter (m) to be sampled (log •-^LC unifonn). Cuttings Spall Grain Diameter Calculation, Performed by B. M. Butcher, March 28, 1996 l.C-tC*- 2.CA/0 «.e^z ielmXmX.S.lTie3) - '- • 7 x --i-.arn**'-- \fp\ Sandia National Laboratories Operated lor lhe U.S. Departmenl of Energy by Sandia Corporation Albuquerque. New Mexico 87185aat.: to.* March 18,1997 Charlene Lanier, 6S4S *onv Mar / -AlenaMaS6S4 , 9 ^ T C ^ ^ ( l L ^ ^ l L j j i 0 subject Additional information fof^d:2823j^mtrl: WAS_AREA idpram: PROBDEG WIPP Data Entry Form 464 at WPOS348S1; id:2824 idmtrrR£?OSIT idpram: PROBDEG WIPP Data Entry Form 464 at WPOS33264 This memo is sent to address the need for additional discussion (attached) to justify the values used by
Brush, L.H. 1990. Test Plen for Laboratory and Modeling Studies of Repository and Radionuclide Chemistry for' the Waste Isolation Pilot Plant. SAND90-0266. Albuquerque, NM: Sandia National Laboratories. CCA Reference No. 91.
Brush, L.H. 1995. Systems Prioritization Method- Iteration 2 Baseline Position Paper: Cas Generation in the Wcste Isolation Pilot Plant. Albuquerque, NM: Sandia National Laboratories. CCA Reference No. 92. •U.S. Department of Energy Carlsbad Area Office. 1996. Transuranic Waste Baseline Inventory Report.
DOE/CAO-95-1121, Rev. 3. Carlsbad, NM: U.S. Depanment of Energy. Contained in the CCA as Appendix BIR. Sandia National Laboratories y Operaled for me U.S. Depanmenl of Energy by Sandia Corporation Albuquerque. New Mexico 87185date: March,20,1997 Charlene Lanier, 6848 from.* Mary-Alena Manet 6849 ^ ^ U ^ . ~&&L^_ ^U^jM wi/e<r Additional information for: id:3473 idmtrl: BLOWOUT idpram: THCK_CAS WIPP Data Entry Form 464 at WPOS3S213 This memo is sent to address the need for additional information (see attached memo) to justify the values used by BRAGFLO_DBR for the Thickness ofthe Castile Formation (THCK_CAS). Please add this memo to the 464's correspondence files. Distribution:
WBS: 12.07.12:PDD:QA: 464 Corresp/464 Form Exceptional Service in the National Interest Sandia National Laboratories -^ Operated for the U.S. Department of Energy by Sandia Corporation Albuquerque. New Mexi« 371HSdate: March 20,1997 to.* Charlene Lattier, 6848 fro/n.' Maiy-AlenaMarteMl49 v|L-*v subject: Additional information fon id:3456 idmtrl: BLOWOUT idpram: RE_CAST WIPP Data Entry Form 464 at WPO23S208 This memo is sent to address the need for additional information (see atiached memos) to justify the values used by BRAGFLO_DBR for the Extemal Drainage Radius for the Castile Formation (RE_CAST). Please add this memo to tbe 464's correspondence files. Distribution: