Emission Test Report from Georgia Pacific Corporation, Bellingham, WA. Emission Test Report # E643. [A-96-47-II-I-37]
Other documents for the same rulemaking
References
US Environmental Protection Agency. 1993. 40 CFR Part 60, Appendix A, Methods 1, 2, 3, 3a, 4, 5, 8, and 16a. Federal Register, (July 1). Antec Environmental Services, Inc. P.12 Method 1 - Sample and Velocity Traverses for Stationary Sources
Martin, Robert M. Construction Details of Isokinetic Source-Sampling Equipment. Environmental Protection Agency. Research Triangle Park, NC. APTD-0581. April 1971.
Rom, Jerome J. Maintenance, Calibration, and Operation of Isokinetic Source Sampling Equipment. Environmental Protection Agency. Research Triangle Park, NC. APTD-0576. March 1972.
Smith, W.S., R.T. Shigehara, and W.F. Todd. A Method of Interpreting Stack SampUng Data. Paper Presented at the 63 rd Annual Meeting ofthe Air Pollution Control Association, St. Louis, MO. June 14-19,1970.
APCA Paper No. 67-119. 1967. Specifications for Incinerator Testing at Federal Facilities. PHS, NCAPC. 1967.
Shigehara, R.T. Adjustment in the EPA Nomograph for Different Pitot Tube Coefficients and Dry Molecular Weights. Stack Sampling News 2:4-11. October 1974.
Vollaro, R.F. A Survey of Commercially Available Instrumentation for the Measurement of Low-Range Gas Velocities. U.S. Environmental Protection Agency, Emission Measurement Branch. Research Triangle Park, NC. November 1976 (unpublished paper). Annual Book of ASTM Standards. Part 26. Gaseous Fuels; Coal and Coke; Atmospheric Analysis. American Society for Testing and Materials. Philadelphia, PA. 1974. pp. 617-622.
10. Felix, L.G, G.I. Clinard, G.E. Lacy, and J.D. McCain. Inertial Cascade Impactor Substrate Media for Flue Gas Sampling. U.S. Environmental Protection Agency. Research Triangle Park,NC277U. Publication No. EPA-600/7-77-060. June 1977. 83 p.
Westlin, P.R. and RT. Shigehara. Procedure for CaUbrating and Using Dry Gas Volume Meters as CaUbration Standards. Source Evaluation Society Newsletter. 3(1): 17-30. February 1978.
12. Lodge, J.P., Jr., J.B. Pate, BE. Ammons, and G.A. Swanson. The Use of Hypodermic Needles as Critical Orifices in Air SampUng. J. Air PoUution Control Association. 16:197-200. 1966. Method 6C - Determination of Sulfur Dioxide Emissionsfrom Stationary Sources (Instrumental Analyzer Procedure)
Westlin, Peter R. and John W. Brown. Methods for CoUecting and Analyzing Gas Cylinder Samples. Source Evaluation Society Newsletter. 3(3):5-15. September 1978. P.61 Method 7E - Determination of Nitrogen Oxides Emissionsfrom Stationary Sources (Instrumental Analyzer Procedure)
McElroy, Frank. The Intertech NDIR-CO Analyzer. Presented at 11th Methods Conference on Air PoUution, University of California, Berkeley, CA. April 1,1970.
Jacobs, M B , et al. Continuous Determination of Carbon Monoxide Infrared Analyzer. J. Air Pollution Control Association. 9(2): 110-114. August 1959. Mine Safety Appliance Co. MSA LIRA Infrared Gas and Liquid Analyzer Instruction Book. Technical Products Division, Pittsburgh, PA. Beckman Instruments, Inc. Models 215A, 315A, and 415A Infrared Analyzers. Beckman Instructions 1635-B, Fullerton, CA. October 1967. Intertech Corporation. Continuous CO Monitoring System, Model A5611. Princeton, NJ. BendixCorp. UNOR Infrared Gas Analyzers. Ronceverte, WV.