Report, Secondary Aluminum Smelters: Screening Level Indirect Risk Assessment, EPA:ESD:REAG, January 1997 [A-92-55-I-A-123]
Other documents for the same rulemaking
References
Jindal, M. and D. Heinhold. 1991. Development of Particulate Scavenging Coefficients to Model Wet Deposition from Industrial Combustion Sources. Paper 91-59.7. Annual Meeting - Exhibition of Air and Waste Management Association, Vancouver, BC. June 16-21, 1991. U.S. EPA. 1990a. Exposure Factors Handbook. Office of Health and Environment Assessment. Washington, DC. EPA/600/8-89/043. U.S. EPA. 1990b. Methodology for Assessing Health Risks Associated with Indirect Exposure to Combustor Emissions. Interim Final. Office of Health and Environment Assessment.
Washington, DC. EPA/600/6-90/03. U.S. EPA. 1993. Addendum: Methodology for Assessing Health Risks Associated with Indirect Exposure to Combustor Emissions. Working Group Recommendations. Office of Solid Waste and Office of Research and Development. Washington, DC. U.S. EPA. 1994a. Estimating Exposure to Dioxin-Like Compounds. Volume III. Site-Specific Procedures. Draft. Office of Research and Development, Washington, DC. U.S. EPA. 1994b. Guidance for Performing Screening Level Risk Analyses at Combustion Facilities Burning Hazardous Wastes. Review Draft. Office of Emergency and Remedial Response, Office of Solid Waste. Washington D.C. December.
U.S.EPA. 1994c. Mercury Study Report to Congress. OAQPS, Cincinnati, Ohio. Draft, December.
U.S.EPA. 1995. User's Guide for the Industrial Source Complex Dispersion Models. Office of Air Quality Planning and Standards, RTP, NC. Draft. U.S. EPA. 1996a. Exposure Factors Handbook. Draft. National Center for Environmental Assessment. Washington, DC. NCEA-W-005. U.S. EPA. 1996b. Risk Assessment Support to the Development of Technical Standards for Emissions from Combustion Units Burning Hazardous Wastes. Prepared by Research Triangle Institute under contract 68-W3-0028.
Weston. 1996a. MACT Standard Development Emission Test Report, Uhrichville, Ohio Factory. Prepared by Roy F. Weston, Inc. for IMCO Recycling, Inc. Work Order No. 11441-002001.
Weston. 1996b. Scrap Dryer and Reverberatory Furnace Emission Test Report. Prepared by
EPA's OAQPS-TTN bulletin board. The scavenging coefficients associated with the particle size distribution were obtained from Jindal and Heinhold (1991). Liquid and frozen scavenging coefficients were set equal. Gases were assumed to behave as extremely small particles in the air dispersion modeling. The value 1.7E-4 (h/mm-s) for the gas scavenging coefficient was also taken from Jindal and Heinhold (1991). Table 6. Particle Size Distribution and Liquid Scavenging Coefficients Liquid and Frozen Scavenging Coefficients (h/mm-s) Particle Size Diameter (pm) Surface Area Based Distribution (Fraction) 1.25 0.90 0.6E-4 4.25 0.02 0.02 3.1 E-4 5.5E-4 0.06 6.7E-4 Air dispersion modeling was conducted over a polar array of receptors, along 16 radials spaced at varying distances out to 10 kilometers. The emissions sources were assumed to be collocated at the origin ofthe 10-kiiometer radius. Receptors were located at high-end and central-tendency distances of 500 and 5000 meters respectively, which means that the highest combined value of air concentration of vapors and combined deposition of particles along the 500m and 5000m ring was selected as the receptor location.