Reference 73 EPA 2018 2017 Five-Year Review of 2012 RWQC
Other documents for the same rulemaking (all, by stage)
References
IAC (IAC5) (Ct 1.5) EPA Method A (or Haugland et al., 2005) Raith et al., 2014
CA (9) reported Not reported 306 (5)j SPC (Sketa 2) (Ct Zimmer-Faust et al., 2014 M, FW
CA, Mexico (18) AW, NPS, WW, SS 82 (0) Not reported Cao et al., 2012 M, FW
CA, IL (52) NPS, HW 133 (7) 133 (1) SPC (Sketa 2) (Ct Citation Water Type Location (# of sites) Fecal Source # of Samples Undiluted (% interference) # of Samples Diluted 5X (% interference) Strategies to Test Interference Cao et al., 2012 M, FW
CA, IL (52) NPS, HW 133 (42) 133 (7) IAC (IAC5) (Ct 1.7)a Haugland et al., 2012 Ohio River
SPC (Sketa 2) (Ct reported Not reported Haugland et al., 2012
IAC (Ct 1.5) Haugland et al., 2012 AZ, CA,
SPC (Sketa 2) (Ct Sauer et al., 2011 NPS, WW 214 (< 1) Not reported Abdelzaher et al., 2010
FL (1) NPS, HW 12 (0) Not reported Scorpionf (Noble et al. 2010) Raith et al., 2014
CA (9) reported Not reported 306 (5)i SPC (Ct > 1.7) Cao et al., 2013
CA (9b) HW, SS, Not reported 12 (0) SPC (Sketa 22 Converse et al., 2012b
CA (3) 1,200 (16) Not reported SPC (Ct 1.6) Cao et al., 2012 M, FW
CA, IL (52) NR, NPS, 133 (42) 133 (4) SPC (Sketa 2) (Ct Cao et al., 2012 M, FW
CA, IL (52) NR, NPS, 133 (56) 133 (18) IAC (Ct 1.7)a Noble et al., 2010 M, FW
IAC (Ct 1.5) Water Type Location (# of sites) Fecal Source # of Samples Undiluted (% interference) # of Samples Diluted 5X (% interference) Strategies to Test Interference Cao et al., 2012 M, FW
SPC (Sketa 2) (Ct Cao et al., 2012 M, FW CA, IL (52)
NPS, HW TF: 133 (53) TF: 133 (8) IAC (IAC5) (Ct 1.7)a Cao et al., 2012 M, FW
NPS, HW TFF: 133 (90) TFF: 42 (37) IAC (IAC5) (Ct 1.7)a Bergeron et al., 2011 Spain, France
HW, SS, 85 (0) Not reported qPCR control Santiago-Rodriguez et al., 2012g
NPS, AW, 130 (0) 130 (0)h Not reported Wang et al., 2016g
Overall, EPA Enterococcus qPCR (Method 1609) resulted in fewer interfering samples, as compared to other methods (EPA Method A, Method 1611, and the Scorpion-based method). Use of the EMM and, when necessary, sample dilution addressed interference at the 9 marine and 23 of the 25 freshwater sites in 10 states that were comprehensively investigated in EPA studies (Haugland et al., 2012, 2016; Sivaganesan et al., 2014). Based on these results, use of
EPA draft Method C [EC23S857]a Chern et al., 2011 M, FW
MA, PR (12) 25 (0) Not reported SPC (Sketa 2) (Ct > 3) Peed et al., 2011
OH (9) NPS, WW 215 (2.1) Not reported IAC (CowM2)b (Ct 35.1 ± 1.8) Molina et al., 2014
SC, FL (5) 471c (7) Not reported IAC (CowM2)b (Ct 33.8 ± 1.6) Krometis et al., 2013
NC (4) 94 (31) 29 (20)d SPC (Sketa 2) (Ct > 1.5) Painter et al., 2013
TX (1) HW, AW Not reported 102 (19)e Converse et al., 2012b
WI (1) 80 (0) Not reported SPC (Sketa 22) (Ct 3) Noble et al., 2010 M, FW
CA (6) WW, UR, 226 (<5) Not reported Ct shift (> 1.5) Cloutier and McLellan, 2017
WI (6) reported Not reported Byappanahalli et al., 2015
IN (1) reported 5c (0) Not reported Walker et al., 2013 M, FW
IAC (Ct <2) Zhang et al., 2012a MO (1) SS, NPS 10c (8) Not reported Bergeron et al., 2011
Spain, France HW, SS, Ct shift (24.5 ± 0.5 cycles) Sauer et al., 2011
WI (4) NPS, WW 220 (<1) Not reported Scorpion (Noble et al., 2010) Other a Current draft method calls for the use of salmon DNA SPC with Sketa22 assay, IAC5 plasmid and assay for inhibition control, 56 degrees Celsius annealing temperature for thermal cycling, and EMM reagent. Some of these provisions were not followed in the reported studies. b IAC using CowM2 plasmid DNA c Estimated d 10x dilution e DNA not diluted but cleaned using post-extraction technique (Chelex®100 and solubilization/binding buffer QX1). Abbreviations and Acronyms: Waterbody Type: M = marine (Pacific Ocean, Atlantic Ocean, brackish stream); FW = Freshwater (river, stream, inland lake, Great Lakes); Fecal Source: NPS = non-point source/urban runoff; HW = human waste; AW = animal waste; FC = fecal contamination; SS = spiked samples; WW = waste water; Interference Controls: SPC = sample processing control; Sketa 22 = primers for salmon sperm DNA; Sketa 2 = primers for salmon sperm DNA; IAC = internal amplification control Digital PCR Digital PCR (dPCR) is an emerging technology for determining the quantity of target DNA sequences in a sample. While traditional qPCR involves measuring DNA products in a single tube after each qPCR cycle, dPCR partitions the sample into thousands to millions of smaller reactions that are examined individually for binary endpoint results (presence/absence). The
DNA density is then estimated from the fraction of positives using Poisson statistics. The dPCR method can be conducted in chambers or droplets, the latter is known as ddPCR. The discussion below does not differentiate between these types of dPCR. The dPCR methods may offer several possible advantages over qPCR discussed below. However, it should be noted that there are few publications to-date that have evaluated the method in ambient waters (Cao et al., 2015, 2016a, b; Wang et al., 2016). Thus, the method is not broadly recommended for routine monitoring, at this time.
First, dPCR does not require a standard curve, thus eliminating some of the labor and materials associated with regularly running batch standards and the biases associated with calibration model variability (Wang et al., 2016). However, it is important to note that a positive standard control is still recommended by dPCR experts (Bustin et al., 2009). As a result, practitioners will still need to create and maintain a standard reference material as a positive control for routine testing.
Finally, dPCR may be superior to qPCR for multiplex reaction applications, amplification of two or more different DNA templates in one reaction (Cao et al., 2016b). Multiplexing in traditional qPCR can lead to an underestimation of the less abundant target if not properly optimized, whereas dPCR may provide more robust quantification of multiple DNA targets. Using dPCR, Cao et al. (2016b) duplexed Enterococcus spp. and HF183 (EntHF183 dPCR assay), which provided accurate and repeatable information on both general and human-associated fecal contamination in environmental waters, without the need to run two separate qPCR tests. There are also several potential limitations of dPCR as compared to qPCR. First, given this is a new technology, there would likely be additional costs associated with implementing it in a laboratory and obtaining the necessary instrumentation and supplies (Huggett et al., 2013).
Secondly, the quantifiable range is smaller for dPCR, and currently the upper limit of quantitation of dPCR is four orders of magnitude lower than that of qPCR. Thus, sample dilution is required when measuring samples with a high concentration of a DNA target, like those potentially found in sewage spills (Cao et al., 2016b). Additionally, Poisson statistics require uniformity in the partitions for accurate results. Viscous DNA, due to high concentrations or long templates, may result in uneven distributions, biasing the partitions and leading to potentially inaccurate results. Finally, if double-stranded DNA is denatured into single strands, the template is effectively increased because single-strands can occupy different partitions, which could lead to up to a two-fold overestimation by dPCR (Cao et al., 2016b). D. References
Newman, X., Shih, P., Bonilla, A., Bonilla, T.D., Palmer, C.J., Scott, T., Lukasik, J., Harwood, V.J., McQuaig, S., Sinigalliano, C., Gidley, M., Plano, L.R.W., Zhu, X., Wang, J.D., Fleming, L.E. 2010. Presence of pathogens and indicator microbes at a non-point source subtropical recreational marine beach. Applied and Environmental Microbiology, 76(3): 724-732.
Bergeron, P., Oujati, H., Catalan Cuenca, V., Huguet Mestred, J.M., Courtoise, S. 2011. Rapid monitoring of Escherichia coli and Enterococcus spp. in bathing water using reverse transcription-quantitative PCR. International Journal of Hygiene and Environmental Health, 214(6): 478-484.
Nolan, T., Pfaffl, M.W., Shipley, G.L., Vandesompele, J., Wittwer, C.T. 2009. The MIQE Guidelines: Minimum information for publication of quantitative real-time PCR experiments. Clinical Chemistry, 55(4): 611-622.
Byappanahalli, M.N., Nevers, M.B., Whitman, R.L., Ishii, S. 2015. Application of a microfluidic quantitative polymerase chain reaction technique to monitor bacterial pathogens in beach water and complex environmental matrices. Environmental Science and Technology Letters, 2(12): 347-351.
Blackwood, A.D., Noble, R.T. 2013. Effect of platform, reference material, and quantification model on enumeration of general fecal indicators by quantitative PCR methods. Water Research, 47(1): 233-241
Cao, Y., Griffith, J.F., Weisberg, S.B. 2016a. The next-generation PCR-based quantification method for ambient waters: Digital PCR. Methods in Molecular Biology 1452:113-30.
Cao, Y., Raith, M.R., Griffith, J.F. 2016b. A duplex digital PCR assay for simultaneous quantification of the Enterococcus spp. and the human fecal-associated HF183 marker in waters. Journal of Visualized Experiments, 9(109).
Cloutier, D.D., McLellan, S.L. 2017. Distribution and Differential Survival of Traditional and Alternative Indicators of Fecal Pollution at Freshwater Beaches. Applied and Environmental Microbiology 83(4).
Converse, R.R., Kinzelman, J.L., Sams, E.A., Hudgens, E., Dufour, A.P., Ryu, H., SantoDomingo, J.W., Kelty, C.A., Shanks, O.C., Siefring, S.D., Haugland, R.A., Wade, T.J. 2012a. Dramatic improvements in beach water quality following gull removal. Environmental Science and Technology 46(18): 10206-10213.
Converse RR, Griffith JF, Noble RT, Haugland RA, Schiff KC, Weisberg SB. 2012b. Correlation between quantitative PCR and culture-based methods for measuring Enterococcus spp. over various temporal scales at three California marine beaches. Applied and Environmental Microbiology 78(4): 1237-1242.
Dorevitch, S., Shrestha, A., DeFlorio-Barker, S., Breitenbach, C., Heimler, I. 2017. Monitoring urban beaches with qPCR vs. culture measures of fecal indicator bacteria: Implications for public notification. Environmental Health 16:45.
Haugland, R.A., Siefring, S.C., Wymer, L.J., Brenner, K.P., Dufour, A.P. 2005. Comparison of Enterococcus measurements in freshwater at two recreational beaches by quantitative polymerase chain reaction and membrane filter culture analysis. Water Research, 39: 559-568.