EPA’s Design for the Environment Garment and Textile Care Program report: Cleaner Technologies Substitutes Assessment - Professional Fabricare Processes
Other documents for the same rulemaking (all, by stage)
References: 513 extracted, 0 linked to papers
WEF. 1995. Water Environment Federation. Controlling Dry Cleaner Discharges in Wastewater: How to Develop and Administer a Source Control Program. Water Environment Federation. Alexandria, 8-31
PCE AND HC DRYCLEANING FACILITIES 9.1.1 Recommended Operating and Maintenance Procedures On September 22, 1993, USEPA finalized the National Emission Standard for Hazardous Air Pollutants (NESHAP) for PCE drycleaners (58 FR 49354). This regulation set standards for the reduction of PCE emissions from drycleaning operations. Included in the NESHAP were requirements that owners or operators of drycleaning machines and control devices follow their manufacturers’ instructions for the proper operation and maintenance of machines and control devices. Owners or operators are required to keep a copy of any manufacturers’ specifications or operating and maintenance recommendations at the drycleaning facility.
USEPA realizes that some drycleaners may no longer have equipment manuals for older drycleaning machines and control devices. However, owners or operators of older machines and control devices should make every reasonable effort to obtain these manuals. These efforts include contacting manufacturers, if the manufacturers are still in business, and contacting local, state, and national trade associations. In case efforts to obtain manufacturers’ manuals are unsuccessful, USEPA’s Office of Air Quality Planning and Standards (OAQPS) has developed many of the following recommendations for operating and maintenance practices for owners or operators of PCE drycleaning machines and emission control devices. The Office of Pollution Prevention and Toxics (OPPT) has supplemented the 1994 Chapter 9 Additional Environmental Improvement Approaches
BAAQMD. 1993. Bay Area Air Quality Management District. An Investigative Survey of Perchloroethylene in Residential Areas Above Dry Cleaners in San Francisco. June.
CEPA. 1993. California Environmental Protection Agency, Air Resources Board. Technical Support Document for Proposed Airborne Toxic Control Measure and Proposed Environmental Training Program for Perchloroethylene Dry Cleaning Operations. August. Department of National Resources and Environmental Control. 1998. A Pollution Prevention Guide for Dry Cleaners. Downloaded from the Environmental Protection Agency’s EnviroSense Web site. March.
IFI. 1992. International Fabricare Institute. Industry Focus. Vol. 16, No. 3. July.
IFI. 1994. International Fabricare Institute. Drycleaning Fundamentals: A Self Study Course. October.
MHS. 1993. Municipal Health Service. Exposure to perchloroethylene in homes nearby drycleaners using closed systems and the effect of remedial actions. Proceedings of Indoor Air <93, Vol. 2.
Amsterdam, the Netherlands. NIOSH. 1997. National Institute for Occupational Safety and Health. Control of Health and Safety Hazards in Commercial Dry Cleaners—Chemical Exposures, Fire Hazards, and Ergonomic Risk Factors. U.S. Dept. of Health, Education, and Welfare, Public Health Service, Centers for Disease Control, NIOSH. Washington, DC. December 1997.
NYSDOH. 1993a. New York State Department of Health. An investigation of indoor air contamination in residences above dry cleaners. Risk Analysis, Vol. 13, No. 3.
NYSDOH. 1993b. New York State Department of Health. Survey of dry cleaning facilities in Capital
NYSDOH. 1994. New York State Department of Health. Investigation of tetrachloroethylene in the vicinity of two dry cleaners: An assessment of remedial measures. Draft report. (The names of the facilities have been removed from this version of the report.)
USEPA. 1994a. U.S. Environmental Protection Agency. New Regulation Controlling Emissions from Dry Cleaners. EPA 453/F-94-025. Office of Air Quality Planning and Standards.
USEPA. 1994b. U.S. Environmental Protection Agency. Perchloroethylene Dry Cleaning Facilities—General Recommended Operating and Maintenance Practices for Dry Cleaning Equipment. EPA 4531R-94-073. Office of Air Quality Planning and Standards. October.
USEPA. 1997. U.S. Environmental Protection Agency. Cleaner Technologies Substitute Assessment Peer Review Comments. 9-20
Beedle, L. 1998. Personal communication between Lee Beedle, Safety-Kleen of Grand Junction,
Exxon. 1998. http://www.exxon/exxoncorp/current_news/fo_Chemical4.html.
Gottlieb, R., J. Goodheart, P. Sinsheimer, C. Tranby, and L. Bechtel. 1997. Pollution Prevention in the Garment Care Industry: Assessing the Viability of Professional Wet Cleaning. UCLA/Occidental College Pollution Prevention Education and Research Center. Los Angeles, CA. December. Hill Jr., J. 1994a. Personal communication between Jim Hill Jr., Hill Equipment Company, and Leland
Deck, Abt Associates Inc. March. Hill Jr., J. 1994b. Personal communications between Jim Hill, Jr., Hill Equipment Company, and Cassandra De Young, Abt Associates Inc. June and August.
Pindyck, R.S., and D.L. Rubinfeld. 1989. Microeconomics. Macmillan Publishing Company. New York,
USEPA. 1991. U.S. Environmental Protection Agency. Dry cleaning facilities - background information for proposed facilities. Draft environmental impact statement. EPA-450/3-91-020a. Office of Air
Wentz, M. 1996. The status of wet cleaning in Canada: the concept of textile care process spectra. Presented at Conf. On Global Experience and New Developments in Wet Cleaning Technology. Schloss Hohenstein, Boennigheim. June. p. 20-25. 10-27
PCE and HC solvents. The company claims “Biotex” is non-carcinogenic, not a VOC, its use will not result in the production of secondary hazardous waste, and that its distillation residue will be dischargeable into ordinary sewage (Berndt, 1998) although these claims are unsubstantiated by USEPA. Bio-Clean Ventures states that “Biotex” will be “...a little higher [priced] than Perc” and makes the following claims, based on their “extensive” testing program: Drycleaners will be able to use “Biotex” in existing PCE machines, with certain modifications to their equipment; “Biotex” can also be used in existing HC machinery without modification.; The solvent will not attack or pull dyes of any type, even at temperatures over 150EF, nor will it shrink garments; It has a degreasing ability of around 58-63, as compared to PCE at 90 and HC at 31; It has a surface tension of 16 dynes/square cm, as compared to PCE at 36; and It is slightly lighter than water. No studies have been found to verify these claims, and the commercial status of this solvent is currently unknown. 11-5 Chapter 11 Emerging Technologies
REFERENCES Abt. 1994. Dry cleaning industry. Use cluster analysis. Final report. Prepared for USEPA, Office of Pollution Prevention and Toxics under Contract No. 68-D2-0175. Abt Associates. April 5.
Berndt. 1998. Personal communication between Dieter Berndt, BioClean and Cindy Stroup, USEPA. May.
Caled. 1995. Comments submitted by Caled on CTSA Phase II drafts sent for stakeholder comments.
Colletti, James. 1998. Personal communication between James Colletti, Rynex Corporation, and Erica Shingara. Abt Associates, Inc. April.
Chao, S. 1994. Personal communication between Sid Chao, Hughes Corporation, and Alice Tome, Abt Associates Inc. December.
DeSimone, J., and M.A. Smith. 1996. Design and application of surfactants for carbon dioxide. Nomination for the Presidential Green Chemistry Challenge Awards Program. November 29.
Global Technologies. 1998. Information downloaded from Global technologies Website: http://www.globaltech.com.
Hayday, W. 1998. Correspondence between William Hayday, Rynex Corporation, and Earl Fischer, America Drycleaner. February.
Hoffman, T. 1998. Personal communication between Thomas Hoffman, Fraunhofer Technology Center
Hughes. 1994. Personal communication between Mariana Purrer, Hughes Environmental Systems, Inc., and Sue Hollenbeck, SAIC. July.
IRIS. 1998. Integrated Risk Information System. http://www.epa.gov/ngispgm3/iris/subst/0404.htm.
Kinsman, R. 1998. Personal communication between Richard Kinsman, Global Technologies, and Erica
Shingara, Abt Associates Inc. April. Lienhart. 1998. Personal communication between R. Bradley Lienhart, MiCELL Technologies, and Jonathan Greene, Abt Associates, Inc. April 22. MiCELL. 1997. MiCELL Technologies. Providing cleaner solutions. April 10.
Porter, D., et al. 1995. An environmentally conscious approach to clothes maintenance. Final report. Prepared for the U.S. Department of Energy under contract DE-ACO4-76-DP00613. December.
Rynex Corporation. 1997. Information on Rynex downloaded from Web site http://www.rynex.com. 11-6 Chapter 11 Emerging Technologies
SRI. 1976. Stanford Research Institute. Criteria for a recommended standard. Occupational exposure to carbon dioxide. Prepared for NIOSH. Menlo Park, CA. PB-266 597. August.
USEPA. 1986. Health Effects Assessment for Glycol Ethers. USEPA Office of Research and Development EPA-540-1-86-052.
USEPA. 1996. Site Visit Summary Report: Liquid Carbon Dioxide Technology Development. By Scott
CAS. 1993. Chemical Abstracts Service. On-line search of Registry File. August.
Clark, B., J.G. Henry, and D. Mackay. 1995. Fugacity analysis and model of organic chemical fate in a sewage treatment plant. Environ Sci Technol 29:1488-1494.
Meylan, W.M., and P.H. Howard. 1991. Bond contribution method for estimating Henry’s Law constants. Environ Toxicol Chem 10:1283-1293.
Meylan, W.M., and P.H. Howard. 1995. Atom/fragment contribution method for estimating octanolwater partition coefficients. J Pharm Sci 84:83-92.
Meylan, W.M., P.H. Howard, and R.S. Boethling. 1992. Molecular topology/fragment contribution method for predicting soil sorption coefficients. Environ Sci Technol 26:1560-1567.
Meylan, W.M., P.H. Howard, and R.S. Boethling. 1996. Improved method for estimating water solubility from octanol/water coefficient. Environ Toxicol Chem 15(2):100-106.
SRC. 1993a. Syracuse Research Corporation. National center for manufacturing sciences solvents database. Syracuse, NY. Version 1.5. July 1.
SRC. 1993b. Syracuse Research Corporation. LOGKOW Program. Version 1.10a. Syracuse, NY. July 18.
Versar. 1987. Versar, Inc. Physical/chemical properties, environmental fate and mobility, and monitoring data for six halogenated solvents. Prepared by VERSAR, Inc. under Contract No. 6802-4254, Task 43. USEPA, Office of Pollution Prevention and Toxics. July 31. A-17