U.S. EPA, Integrated Science Assessment for Ozone and Related Photochemical Oxidants, EPA/600/R-20/012, April 2020
Other documents for the same rulemaking (all, by stage)
References
Vinken, GCM; Boersma, KF; Maasakkers, JD; Adon, M; Martin, RV. (2014). Worldwide biogenic soil NOx emissions inferred from OMI NO2 observations. Atmos Chem Phys 14: 10363-10381. http://dx.doi.org/10.5194/acp-14-10363-2014
Mcgee, TJ; Pliutau, D; Senff, CJ; Sullivan, JT; Sumnicht, G; Twigg, LW; Weinheimer, AJ. (2017). Quantifying TOLNet ozone lidar accuracy during the 2014 DISCOVER-AQ and FRAPPE campaigns. Atmos Meas Tech 10: 3865-3876. http://dx.doi.org/10.5194/amt-10-3865-2017
Wang, YH; Jacob, DJ; Logan, JA. (1998). Global simulation of tropospheric O-3-NOx-hydrocarbon chemistry 1. Model formulation. J Geophys Res Atmos 103: 10713-10725. http://dx.doi.org/10.1029/98JD00158
Gilman, JB; Lerner, BM; Peischl, J; Ryerson, TB; de Gouw, JA; Roberts, JM. (2014). Volatile organic compound emissions from the oil and natural gas industry in the Uintah Basin, Utah: oil and gas well pad emissions compared to ambient air composition. Atmos Chem Phys 14: 1097710988. http://dx.doi.org/10.5194/acp-14-10977-2014
Davis, S; Degenstein, D; Fioletov, VE; Froidevaux, L; Hubert, D; Long, CS; Loyola, D; Rozanov, A; Roth, C; Sofieva, V; Tourpali, K; Wang, R; Wild, JD. (2018). State of the climate in 2018: Stratospheric ozone. Bull Am Meteorol Soc 100: S54-S56.
Gille, JC; Hurtmans, D; Luo, M; Martinez-Alonso, S; Massie, S; Pfister, G; Warner, JX. (2013). Decadal record of satellite carbon monoxide observations. Atmos Chem Phys 13: 837-850. http://dx.doi.org/10.5194/acp-13-837-2013
Wu, SL; Duncan, BN; Jacob, DJ; Fiore, AM; Wild, O. (2009). Chemical nonlinearities in relating intercontinental ozone pollution to anthropogenic emissions. Geophys Res Lett 36: L05806. http://dx.doi.org/10.1029/2008gl036607
Pinder, RW. (2013). Understanding the impact of recent advances in isoprene photooxidation on simulations of regional air quality. Atmos Chem Phys 13: 8439-8455. http://dx.doi.org/10.5194/acp-13-8439-2013
DC; Hao, J. (2017). Impacts of aerosol direct effects on tropospheric ozone through changes in atmospheric dynamics and photolysis rates. Atmos Chem Phys 17: 9869-9883. http://dx.doi.org/10.5194/acp-17-9869-2017
Xing, J; Mathur, R; Pleim, J; Hogrefe, C; Gan, CM; Wong, DC; Wei, C; Gilliam, R; Pouliot, G. (2015). Observations and modeling of air quality trends over 1990-2010 across the Northern Hemisphere: China, the United States and Europe. Atmos Chem Phys 15: 2723-2747. http://dx.doi.org/10.5194/acp-15-2723-2015
Yahya, K; Wang, K; Zhang, Y; Kleindienst, TE. (2015). Application of WRF/Chem over North America under the AQMEII Phase 2-Part 2: Evaluation of 2010 application and responses of air quality and meteorology-chemistry interactions to changes in emissions and meteorology from 2006 to 2010. GMD 8: 2095-2117. http://dx.doi.org/10.5194/gmd-8-2095-2015 1-88
Ying, Q; Krishnan, A. (2010). Source contributions of volatile organic compounds to ozone formation in southeast Texas. J Geophys Res Atmos 115: Article #D17306. http://dx.doi.org/10.1029/2010JD013931
Schnell, JL; Tilmes, S; Wild, O; Zhang, L; Ziemke, J; Brandt, J; Delcloo, A; Doherty, RM; Geels, C; Hegglin, MI; Hu, L; Im, U; Kumar, R; Luhar, A; Murray, L; Plummer, D; Rodriguez, J; SaizLopez, A; Schultz, MG; Woodhouse, MT; Zeng, G. (2018). Tropospheric Ozone Assessment Report: Assessment of global-scale model performance for global and regional ozone distributions, variability, and trends. Elementa: Science of the Anthropocene 6. http://dx.doi.org/10.1525/elementa.265
Zare, A; Christensen, JH; Gross, A; Irannejad, P; Glasius, M; Brandt, J. (2014). Quantifying the contributions of natural emissions to ozone and total fine PM concentrations in the Northern Hemisphere. Atmos Chem Phys 14: 2735-2756. http://dx.doi.org/10.5194/acp-14-2735-2014
DBA; Murray, LT; Wang, Y. (2011). Improved estimate of the policy-relevant background ozone in the United States using the GEOS-Chem global model with 1/2 2/3 horizontal resolution over North America. Atmos Environ 45: 6769-6776. http://dx.doi.org/10.1016/j.atmosenv.2011.07.054
Zhang, L; Jacob, DJ; Kopacz, M; Henze, DK; Singh, K; Jaffe, DA. (2009). Intercontinental source attribution of ozone pollution at western US sites using an adjoint method. Geophys Res Lett 36: L11810. http://dx.doi.org/10.1029/2009gl037950
Zhang, L; Jacob, DJ; Yue, X; Downey, NV; Wood, DA; Blewitt, D. (2014). Sources contributing to background surface ozone in the US Intermountain West. Atmos Chem Phys 14: 5295-5309. http://dx.doi.org/10.5194/acp-14-5295-2014
Zhang, L; Jaffe, DA. (2017). Trends and sources of ozone and sub-micron aerosols at the Mt. Bachelor Observatory (MBO) during 2004-2015. Atmos Environ 165: 143-154. http://dx.doi.org/10.1016/j.atmosenv.2017.06.042
Zhang, R; Cohan, A; Biazar, AP; Cohan, DS. (2017). Source apportionment of biogenic contributions to ozone formation over the United States. Atmos Environ 164: 8-19. http://dx.doi.org/10.1016/j.atmosenv.2017.05.044
Zhang, Y; Cooper, OR; Gaudel, A; Thompson, AM; Nedelec, P; Ogino, SY; West, JJ. (2016). Tropospheric ozone change from 1980 to 2010 dominated by equatorward redistribution of emissions. Nat Geosci 9: 875-+. http://dx.doi.org/10.1038/NGEO2827
Zhao, H; Zheng, Y; He, K; Zhang, Q. (2018). Trends in China's anthropogenic emissions since 2010 as the consequence of clean air actions. Atmos Chem Phys 18: 14095-14111. http://dx.doi.org/10.5194/acp-18-14095-2018
Yang, K; Rappenglück, B; Millet, DB; Baasandorj, M; Jaeglé, L; Shah, V. (2017). Formaldehyde (HCHO) as a hazardous air pollutant: Mapping surface air concentrations from satellite and inferring cancer risks in the United States. Environ Sci Technol 51: 5650-5657. http://dx.doi.org/10.1021/acs.est.7b01356 1-89
Richter, D; Scarino, A; Walega, J; Weibring, P; Wolfe, GM. (2016). Observing atmospheric formaldehyde (HCHO) from space: validation and intercomparison of six retrievals from four satellites (OMI, GOME2A, GOME2B, OMPS) with SEAC(4)RS aircraft observations over the southeast US. Atmos Chem Phys 16: 13477-13490. http://dx.doi.org/10.5194/acp-16-13477-2016
Szykman, JJ; Torres, O; Veefkind, JP; Veihelmann, B; Wang, H; Wang, J; Chance, K. (2017). Tropospheric emissions: Monitoring of pollution (TEMPO). J Quant Spectrosc Radiat Transf 186: 17-39. http://dx.doi.org/10.1016/j.jqsrt.2016.05.008 1-90
ISA. Section 2.3.1.2 presents new studies of microenvironmental and personal ozone monitors, the results of which mostly agree with studies presented in the 2013 Ozone ISA. A new development in using data-processing algorithms to improve the quality of ozone concentration data obtained using low-cost monitors is highlighted. 2.3.1.1 Fixed-Site Monitors The 2013 Ozone ISA (U.S. EPA, 2013) described the use of two types of fixed-site Federal Reference Method (FRM) ozone monitors to provide a surrogate for ozone exposure: ultraviolet (UV) absorption photometric analyzers and chemiluminescence analyzers. Positive biases were noted for the
Like LUR, spatiotemporal models may use land use and geographic covariates to model ozone concentration, but these models may also include a more flexible statistical model formulation and additional modeling inputs, such as kriging or methods that incorporate an autoregressive structures (Wang et al., 2015). Spatiotemporal models were applied in several recent studies to improve predictions of ozone concentrations for exposure assessment studies (Table 2-11). Several studies used BME approaches, although the prior information varied across studies and included the kriging mean trend and the covariance function. BME applies known information as a prior geostatistical distribution, maximizes an entropy function of the prior distribution, and then applies a Bayes function to estimate a posterior distribution [i.e., the predicted concentration field; He and Kolovos (2018); Christakos (1990)]. An important advantage of BME is that it incorporates multiple sources of model inputs (e.g., land use regression and monitoring data), allowing for the minimization of errors (Adam-Poupart et al., 2014; Warren et al., 2012). BME can also provide a good representation of variability, with both spatial and temporal variability well represented when autoregressive priors are used (Sahu and Bakar, 2012a, b).
CA; Los Angeles, CA; Vancouver, Canada; Wang et al. (2016); Steyn et al. (2013); Hu et al. (2012); Tsimpidi et al. (2012); Ying and Li (2011)]. The horizontal grid resolution of a CTM can influence the heterogeneity of an ambient concentration surface and the associated exposure estimate, but those effects are generally only seen for areas of peak concentrations. Some studies directly compared how ozone model performance statistics changed with the size of a given grid cell (Yu et al., 2016; Schaap et al., 2015; Thompson and Selin, 2012; Tsimpidi et al., 2012). The majority of these studies found that the cumulative distribution function and summary statistics did not vary greatly among the simulations using different spatial resolutions.
However, the upper and lower tails of the distributions had greater error for coarse resolution simulations compared with fine resolution simulations (Yu et al., 2016). Schaap et al. (2015) compared the Multiscale Chemical Transport Model for Atmospheric Composition Analysis and Forecast (CHIMERE), CMAQ, European Monitoring and Evaluation Program (EMEP), Research and Development Center for Global Change (RCGC), and Long-Term Ozone Simulation-European Operational Smog (LOTOS-EUROS) models across grid resolutions for rural, suburban, and urban areas. They found that the largest magnitude biases between the model and observations were for the urban simulations, and the models more often overestimated rather than underestimated measurements for all settings. These findings are consistent with older studies not cited in the 2013 Ozone ISA (U.S. EPA, 2013). Cohan et al. (2006) compared
OH and found that 54% of the children changed residential address during that time, resulting in a 4.4% decrease in the cohort’s average traffic-related air pollution concentration (defined as black carbon estimates from an LUR model for this study). They also noted that if the birth address is used for exposure estimation during the entire study period, exposure misclassification is increased for those that move earlier (due to more years at the incorrect address) or are more highly exposed (due to a greater likelihood of moving). The Brokamp et al. (2015) study showed that not accounting for residential mobility resulted in bias toward the null. Exposure measurement error due to incorrect home address would be expected to be lower for ozone compared with more spatially variable air pollutants, but it would not necessarily be negligible. Studies examining seasonal differences in time-activity data are limited. Spalt et al. (2015) in the
Miami, FL Nashville, TN 1987−2000 (continued) Home (estimated residents by model) (continued) (continued) 2-23 Table 2-4 (Continued): Summary of U.S. studies of ozone infiltration published after 2011.
Sacramento Area, 2013 Fresno, Los Angeles Area, CA Johnson et al. (2014) Durham, NC August– September 2012 I/O Ratio Correlation Grocery stores
Houston, TX Simulation Ng et al. (2015) Atlanta, GA Ambient Ozone Population Microenvironment Concentration I/O Ratio Correlation Simulated homes No passive removal materials Average: 0.16 0.5/h Simulated homes
ASHRAE prescribed ventilation Average of daily average (daily peak): 76 ppb (93 ppb) Calculated as mean indoor/daily average outdoor: daily average (daily peak): 0.13 (0.13) 1.2 L/s-m2 Volume-weighted concentrations Average of daily average (daily peak): 76 ppb (93 ppb) Calculated as mean indoor/daily average outdoor: daily average (daily peak): 0.079 (0.075) 0.4 L/s-m2 2-26 Table 2-4 (Continued): Summary of U.S. studies of ozone infiltration published after 2011. Reference Lai et al. (2015) Location West Lafayette, Time Period Ambient Ozone Population Microenvironment Concentration Test chamber I/O Ratio Correlation Infiltration 24.02– 53.5 ppb 0.050–0.099 Median (10th–90th percentile) 0.40 (0.15–0.85) Simple mechanical ventilation 38.96– 39.69 ppb 0.57–0.63 Median (10th–90th percentile) 0.98 (0.22–4.84)
Miami, FL; Data from Houston, TX; 2013 or
Sacramento, CA Ben-David and Waring (2018) Time Period January– February 2014 15 cities: 1999–2015
Detroit, MI February 2008–April 2009 U.S. EPA mild to Mean (SD): 3.4 ppb Mean (SD): severe, (3.6 ppb) 29.7 ppb nonsmoking adult (15.0 ppb) asthmatics and their environment study panel (N = 16) 0.0665 (slope) P/A: 0.27 Chen et al. (2012)
NMMAPS cities: 1987–2000 All residents Calculated change in total ozone exposure per unit change in ambient ozonea
Buffalo, NY 0.30 Chicago, IL 0.28 Cincinnati, OH 0.27 Corpus Christi, 0.28 Dallas/Ft. Worth, 0.27 2-31 Table 2-5 (Continued): Studies reporting relationships between personal ozone exposures and ambient ozone concentrations. Reference Chen et al. (2012) (continued) Jones et al. (2013) Location
Denver, CO Time Period 1987–2000 (continued) Population All residents (continued) Personal Concentration
Washington, DC 0.27 Worcester, MA 0.27 New York City, June 1– August 31, 2001–2005 Hospital admissions for respiratory diagnoses (N = 34,760 respiratory hospitalizations) Avg 8-h daily max (95th percentile): 12.78 ppb (20.78 ppb) Avg 8-h daily max: 30.67 ppb Mean (95th percentile): 0.48 (0.83) P/A: 0.979
SEARCH, U.S. EPA PAMS, U.S. EPA STN, IMPROVE monitoring networks L: In and near the Atlanta metropolitan area; T: Between the yr 1999 and 2007; P: Entire population considered Observed Long-term fixed-site exposure ambient monitors only, protocols of observed data were referenced in previous publications Mean summer quartiles of peak 8-h ozone in ppb, 44.85, 55.73, 64.93, 80.23 Observed Spatial data collected variability is directly; limited to speciation monitoring collected; locations several years of data collected Hackbarth et al. (2011) Daily 8-h max ozone within 20 miles of the zip-code centroid weighted by inverse distance from U.S. EPA's fixed-site monitors L: California; T: 2005– 2007; P: Those with
ER visits for cardio, resp, asthma Observed data Short-term used in exposure inverse-distance weighting validated from U.S. EPA Ozone daily avg in California between 2005 and 2007 because 37.1−73.8 ppb Observed data used directed with
FEM ambient 19, 2010; monitors (two P: Entire models: population Teledyne Model 211 and Teledyne Model 265E). The Teledyne Model 265E has since been certified as an FRM Comparison Short-term between exposure ambient monitor types using air spiked with known quantity of ozone 8-h daily max = avg 22 ppb, max 94 ppb, 19 values and 6 days with 8-h daily max above 75 ppb Average and maximum data compare well; frequent calibrations zero/span improved data quality Positive bias of FRM due to water vapor, gas-phase mercury, and VOCs Differences between monitors presented graphically but not reported Johnson et al. (2014)
FEM ambient L: Durham, monitor T: September 2012; P: Entire population Comparison with an FRM and a microenvironmental model 10-min avg value = 33.0−55.2 ppb Average values are only slightly higher than Potentially high positive errors in vicinity of VOC sources In the vicinity of VOC sources, ozone concentration from the FEM was several hundred percentage higher (depending on the source) than a microenvironmental monitor that compared well with the Short-term exposure 2-61 Table 2-8 (Continued): Studies informing assessment of exposure measurement error when concentrations measured by fixed-site monitors are used for exposure surrogates. Reference Buteau et al. (2017) Monitor Fixed-site monitors reporting data for 8-h daily Location, Time Period, Population L: Montreal, Quebec, Canada; T: January 1, 1991– December 31, 2002; P: Entire population Measurement Evaluation Technique Epidemiology Applications Comparison Short-term with BME, IDW, exposure and backextrapolation 2-62 Concentrations Measured 8-h daily max; mean (SD) = 27.9 ppb (15.2 ppb) median = 26.3 ppb Strengths Limitations Most accurate measure of ozone Lacks spatial resolution Exposure Measurement Errors
CAN; comparison to T: Winter fixed-site and summer, monitors 2005–2006; P: Adults and children with asthma Panel study Mean (SD) = 26 ppb (9 ppb); median = 25 ppb Can be used for personal, indoor, and outdoor sampling Bart et al. (2014) Gas sensitive semiconductor monitors L: Lower Fraser Valley, British Columbia, Canada; T: May– September 2012; P: Entire population Panel study
MB = −1 ppb SE = 6 ppb Table 2-9 (Continued): Studies informing assessment of exposure measurement error when concentrations measured by personal and microenvironmental monitors are used for exposure surrogates. Location, Time Period, Population Measurement Evaluation Technique Epidemiology Applications Concentrations Measured Reference Monitor Zimmerman et al. (2018) Low-cost sensor (Real-Time Affordable Multipollutant sensors) data filtered through model to improve data quality based on data across geographical area L: Pittsburgh, T: August 3, 2016– February 7, 2017; P: Carnegie Mellon University campus population Deployed a Short-term dense network of exposure low-cost samplers then applied one of two models (random forest or multiple linear regression) to smooth data for ozone 15-min avg time; NR Sagona et al. (2018) Personal ozone monitor operates by UV light absorption at 254 nm wavelength (2B Technologies) Piscataway, T: July 2014; P: Panel of volunteers Comparison of personal monitors with
IDW of data from 10 fixed-site monitors Location, Time Period, Population L: Atlanta, T: 2011; P: Entire population Measurement Evaluation Technique Comparison with fixed-site monitors Epidemiology Applications Short-term exposure Concentrations Measured 2-68 Strengths Better spatial resolution than monitor-based approaches Limitations Exposure Measurement Errors Quality of model Urban site: depends on spatial MB = −1.27 ppb, density of the
AQS; kriged surface is fit to high concentration monitors, low concentration monitors, randomly selected monitors, or all monitors Concentrations Measured Exposure Measurement Errors Strengths Limitations Mean (SD) for select hours 3/25/2012 2:00 p.m. = 68.2 ppb (6.15 ppb) 4/24/2012 2:00 p.m. = 65 ppb (6.32 ppb) 5/17/2012 2:00 p.m. = 72.7 ppb (10 ppb) 6/28/2012 3:00 p.m. =
BME-LUR hybrid model) Table 2-11 (Continued): Studies informing assessment of exposure measurement error when concentrations modeled by land use regression or spatiotemporal models are used for exposure surrogates. Reference Buteau et al. (2017) Model Land use regression with backextrapolation,
LUR model built from 76 monitors and included variables for land use and the built environment Location, Time Period, Population L: Montreal, Quebec, Canada; T: January 1, 1991– December 31, 2002; P: Entire population Measurement Evaluation Technique Epidemiology Applications Comparison with Short-term