Policy Replication

2015-02 Condensing Furnace Venting Part 2 - Evaluation of Same-Chimney Vent Systems for Condensing Furnaces and Natural Draft Water Heaters (ORNL/TM-2014/656)

Docket document2022-04-11 · EERE · report · EERE-2018-BT-STD-0018-0151
RIN 1904-AE39 · Docket EERE-2018-BT-STD-0018

Other documents for the same rulemaking (all, by stage)

2016-04-21 Regulatory impact analysis2016-04-18 Technical Support Document (TSD): Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment: Commercial Water Heating Equipment
2017-04-03 Regulatory impact analysis2017-03-14 Executive correspondence from APGA, Spire Inc., ACCA, et al., to Secretary Perry requesting correction of regulatory analysis before final actions are taken.
2021-01-15 Federal RegisterEnergy Conservation Program for Appliance Standards: Energy Conservation Standards for Residential Furnaces and Commercial Water Heaters
2021-01-15 Federal RegisterEnergy Conservation Program for Appliance Standards: Energy Conservation Standards for Residential Furnaces and Commercial Water Heaters; Withdrawal
2021-01-15 Docket documentDocumentation of Changes between the draft Final Rule Withdrawal submitted to the Office of Information and Regulatory Affairs (OIRA) and the issued Final Rule Withdrawal
2021-08-27 Federal RegisterEnergy Conservation Program for Appliance Standards: Energy Conservation Standards for Residential Furnaces and Commercial Water Heaters
2021-09-24 Federal RegisterEnergy Conservation Program for Appliance Standards: Energy Conservation Standards for Residential Furnaces and Commercial Water Heaters: Notification of Proposed Interpretive Rule
2021-12-29 Federal RegisterEnergy Conservation Program for Appliance Standards: Energy Conservation Standards for Residential Furnaces and Commercial Water Heaters
2022-04-11 Docket documentU.S. Census Bureau QuickFacts - United States

References: 6 extracted, 0 linked to papers

Page 1Download these results: CSV · JSON
Momen, A. M., et al. 2014. Condensing Furnace Venting Part 1: The Issue, Prospective Solutions and Facility for Experimental Evaluation, ORNL/TM-2014/624. Oak Ridge National Laboratory, Oak Ridge, Tenn. National Fire Protection Association (NFPA). 2012. National Fuel Gas Code. NFPA 54. Quincy, Mass., National Fire Protection Association.
research reportNot linked to a paper · refsec
Rapp, V. H., et al. 2012. Assessment of Literature Related to Combustion Appliance Venting Systems.
research reportNot linked to a paper · refsec
Timusk, J., et al. 1988. Chimney Venting Performance Study. Journal of Testing and Evaluation, JTEVA,
journal articleNot linked to a paper · refsec
INDUCED FLOW FOR A CHIMNEY The natural draft flow rate induced by the buoyancy force for a stand-alone chimney can be calculated with Eq. A.2. (Walker 2014). For a chimney venting an appliance, where ambient air is on the outside and flue gases are on the inside, Eq. A.2 will provide only an approximation. In addition, this equation assumes frictional or transition pressure losses are zero. T −T Q = C2 A 2 gh( i o ) , where (A.2) Q = natural draft flow rate in m3/s, A = flow area in m2, C2 = discharge coefficient (usually taken to be from 0.65 to 0.70), g = gravitational acceleration at 9.81 m/s2, h = height in m, Ti = average inside temperature in K, To = outside air temperature in K.
research reportNot linked to a paper · refsec
Walker, A. 2014. Natural Ventilation, National Renewable Energy Laboratory, Golden, Colo.
research reportNot linked to a paper · refsec
West Conshohocken, Pa., doi: 10.1520/E1998-11.
journal articleNot linked to a paper · doi