2015-02 Condensing Furnace Venting Part 2 - Evaluation of Same-Chimney Vent Systems for Condensing Furnaces and Natural Draft Water Heaters (ORNL/TM-2014/656)
Other documents for the same rulemaking (all, by stage)
References: 6 extracted, 0 linked to papers
Momen, A. M., et al. 2014. Condensing Furnace Venting Part 1: The Issue, Prospective Solutions and Facility for Experimental Evaluation, ORNL/TM-2014/624. Oak Ridge National Laboratory, Oak Ridge, Tenn. National Fire Protection Association (NFPA). 2012. National Fuel Gas Code. NFPA 54. Quincy, Mass., National Fire Protection Association.
Rapp, V. H., et al. 2012. Assessment of Literature Related to Combustion Appliance Venting Systems.
Timusk, J., et al. 1988. Chimney Venting Performance Study. Journal of Testing and Evaluation, JTEVA,
INDUCED FLOW FOR A CHIMNEY The natural draft flow rate induced by the buoyancy force for a stand-alone chimney can be calculated with Eq. A.2. (Walker 2014). For a chimney venting an appliance, where ambient air is on the outside and flue gases are on the inside, Eq. A.2 will provide only an approximation. In addition, this equation assumes frictional or transition pressure losses are zero. T −T Q = C2 A 2 gh( i o ) , where (A.2) Q = natural draft flow rate in m3/s, A = flow area in m2, C2 = discharge coefficient (usually taken to be from 0.65 to 0.70), g = gravitational acceleration at 9.81 m/s2, h = height in m, Ti = average inside temperature in K, To = outside air temperature in K.
Walker, A. 2014. Natural Ventilation, National Renewable Energy Laboratory, Golden, Colo.
West Conshohocken, Pa., doi: 10.1520/E1998-11.