{"document":{"doc_id":173229,"source":"docket_item","org":"EPA","doc_type":"report","title":"THC/oHAP Test Report","date":"2023-01-05","url":"https://www.regulations.gov/document/EPA-HQ-OAR-2017-0015-0082","source_native_id":"EPA-HQ-OAR-2017-0015-0082","status":"fetched","abstract":null,"action":null},"dockets":["EPA-HQ-OAR-2017-0015"],"rins":["RIN 2060-AV59"],"related":[{"doc_id":129080,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Redline Strikeout Subpart AAAAA—National Emission Standards for Hazardous Air Pollutants for Lime Manufacturing Plants","date":"2020-07-24"},{"doc_id":180806,"source":"docket_item","org":"EPA","doc_type":"report","title":"Residual Risk Assessment for the Lime Manufacturing Source Category in Support of the 2020 Risk and Technology Review Final Rule","date":"2020-07-24"},{"doc_id":78615,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"National Emission Standards for Hazardous Air Pollutants: Lime Manufacturing Plants Amendments","date":"2023-01-05"},{"doc_id":86222,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Memorandum: Economic Impact and Small Business Screening Assessments for Proposed Amendments to the National Emission Standards for Hazardous Air Pollutants for Lime Manufacturing Facilities. November 3, 2022.","date":"2023-01-05"},{"doc_id":128305,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Lime Manufacturing Proposal - Redline Strikeout Version.","date":"2023-01-05"},{"doc_id":173227,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum: Methodology and Assumptions Used to Estimate the Model Costs and Impacts of BSCP Air Pollution Control Devices for the Final Rule. September 24, 2015","date":"2023-01-05"},{"doc_id":173228,"source":"docket_item","org":"EPA","doc_type":"report","title":"Chapter 5: Emission Control Technologies","date":"2023-01-05"},{"doc_id":173230,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Recommended Toxicity Equivalence Factors (TEFs) for Human Health Risk Assessments of 2,3,7,8-Tetrachlorodibenzo-p-dioxin and Dioxin-Like Compounds, EPA/100/R 10/005","date":"2023-01-05"},{"doc_id":173231,"source":"docket_item","org":"EPA","doc_type":"report","title":"Chapter 2: Cost Estimation: Concepts and Methodology. November 2017","date":"2023-01-05"},{"doc_id":173232,"source":"docket_item","org":"EPA","doc_type":"report","title":"IPM Model – Updates to Cost and Performance for APC Technologies. Dry Sorbent Injection for SO2/HCl Control Cost Development Methodology. Final. April 2017","date":"2023-01-05"},{"doc_id":173233,"source":"docket_item","org":"EPA","doc_type":"report","title":"Source Test Report","date":"2023-01-05"},{"doc_id":173234,"source":"docket_item","org":"EPA","doc_type":"report","title":"THC/oHAP Test Report","date":"2023-01-05"},{"doc_id":173235,"source":"docket_item","org":"EPA","doc_type":"report","title":"IPM Model – Revisions to Cost and Performance for APC Technologies. Mercury Control Cost Development Methodology. Final. March 2011.","date":"2023-01-05"},{"doc_id":173236,"source":"docket_item","org":"EPA","doc_type":"report","title":"Evaluation of the Carcinogenicity of HCl and HCl Mist","date":"2023-01-05"},{"doc_id":173238,"source":"docket_item","org":"EPA","doc_type":"report","title":"Source Test Report","date":"2023-01-05"},{"doc_id":173239,"source":"docket_item","org":"EPA","doc_type":"report","title":"Chapter 1: Carbon Adsorbers. October 2018","date":"2023-01-05"},{"doc_id":173240,"source":"docket_item","org":"EPA","doc_type":"report","title":"Lhoist North America: Improved Dry Sorbent Injection (DSI) with Optimized Hydrated Lime","date":"2023-01-05"},{"doc_id":173241,"source":"docket_item","org":"EPA","doc_type":"report","title":"Reference Method Accuracy and Precision (ReMAP): Phase 1.  Precision of Manual Stack Emission Measurements","date":"2023-01-05"},{"doc_id":173242,"source":"docket_item","org":"EPA","doc_type":"report","title":"U.S. Lime Company Source Test Report","date":"2023-01-05"},{"doc_id":173244,"source":"docket_item","org":"EPA","doc_type":"report","title":"Chapter 2: Incinerators and Oxidizers. November 2017","date":"2023-01-05"},{"doc_id":173245,"source":"docket_item","org":"EPA","doc_type":"report","title":"Analysis of Demographic Factors For Populations Living Near Lime Manufacturing Plants","date":"2023-01-05"},{"doc_id":173246,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum from Matt Hakos, RTI International regarding Proposed Maximum Achievable Control Technology (MACT) Floor Analysis for the Lime Manufacturing Plants Industry. October 2022","date":"2023-01-05"},{"doc_id":173248,"source":"docket_item","org":"EPA","doc_type":"report","title":"Chapter 1: Wet and Dry Scrubbers for Acid Gas Control. April 1, 2021","date":"2023-01-05"},{"doc_id":173249,"source":"docket_item","org":"EPA","doc_type":"report","title":"Lime Test Report ER - Volume 1 PA-454/R-99-044a","date":"2023-01-05"},{"doc_id":173251,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum: Methodology and Assumptions Used to Estimate the Model Costs and Impacts of Clay Ceramics Air Pollution Control Devices for the Final Rule. September 24, 2015","date":"2023-01-05"},{"doc_id":173252,"source":"docket_item","org":"EPA","doc_type":"report","title":"Lime Test Report ER - Volume 2","date":"2023-01-05"},{"doc_id":173253,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Memorandum from Matt Hakos, RTI International regarding Development of Impacts for the Proposed Lime Manufacturing Plants NESHAP. November 2022.","date":"2023-01-05"},{"doc_id":173254,"source":"docket_item","org":"EPA","doc_type":"data","title":"Summary of Data Quality Issues with Lhoist Organic HAP Test Reports","date":"2023-01-05"},{"doc_id":173255,"source":"docket_item","org":"EPA","doc_type":"report","title":"Source Test Report","date":"2023-01-05"},{"doc_id":173256,"source":"docket_item","org":"EPA","doc_type":"report","title":"Summary of Environmental and Cost Impacts for Final Portland Cement NESHAP and NSPS. Docket Number EPA‐HQ‐OAR‐2002‐0051. \nAugust 6, 2010","date":"2023-01-05"},{"doc_id":173257,"source":"docket_item","org":"EPA","doc_type":"report","title":"THC/oHAP Test Report","date":"2023-01-05"},{"doc_id":191408,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Final Rule: National Emission Standards for Hazardous Air Pollutants for Source Categories; Portland Cement Manufacturing Industry","date":"2023-01-05"},{"doc_id":191411,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Lime Test Report CLC - Volume 1 EPA-454/R-99-045a","date":"2023-01-05"},{"doc_id":22072,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Lime Manufacturing Plants NESHAP, Final","date":"2024-01-01"},{"doc_id":78612,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"National Emission Standards for Hazardous Air Pollutants: Lime Manufacturing Plants Amendments","date":"2024-02-09"},{"doc_id":86140,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Documentation of Changes Made to Regulatory Impact Analysis: Pass Back No. 1  During OMB Review Under E.O. 12866 through January 10, 2024 - Lime Manufacturing Plants NPRM","date":"2024-02-09"},{"doc_id":86147,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Lime RIA Analysis and Tables","date":"2024-02-09"},{"doc_id":86158,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Documentation of Changes Made to Regulatory Impact Analysis: Pass Back No. 1 During OMB Review Under E.O. 12866 through December 14, 2023 - Lime Manufacturing Plants NPRM","date":"2024-02-09"},{"doc_id":86171,"source":"ria","org":"EPA","doc_type":"regulatory_impact_analysis","title":"Lime RIA Memo","date":"2024-02-09"},{"doc_id":86203,"source":"ria","org":"EPA","doc_type":"ria_oira_review_version","title":"Part of E.O. 12866 Review: Regulatory Impact Analysis - Lime Manufacturing Plants NPRM Pass Back No. 1","date":"2024-02-09"},{"doc_id":86216,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Sensitivity Market Impact Analysis Economic Impact Analysis for the Supplemental Proposed Amendments to the National Emission Standards for Hazardous Air Pollutants: Lime Manufacturing Plants, 2023","date":"2024-02-09"},{"doc_id":86231,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Main Market Impact Analysis Economic Impact Analysis for the Supplemental Proposed Amendments to the National Emission Standards for Hazardous Air Pollutants: Lime Manufacturing Plants, 2023","date":"2024-02-09"},{"doc_id":86236,"source":"ria","org":"EPA","doc_type":"ria_oira_review_version","title":"Part of E.O. 12866 Review - Lime Manufacturing Plants NPRM Regulatory Impact Analysis: Pass Back No. 2.2","date":"2024-02-09"},{"doc_id":86253,"source":"ria","org":"EPA","doc_type":"ria_oira_review_version","title":"Part of E.O. 12866 Review - Lime Manufacturing Plants NPRM Regulatory Impact Analysis: Pass Back No. 1","date":"2024-02-09"},{"doc_id":86258,"source":"ria","org":"EPA","doc_type":"ria_oira_review_version","title":"Part of E.O. 12866 Review: Regulatory Impact Analysis - Lime Manufacturing Plants NPRM Pass Back No. 2.2","date":"2024-02-09"},{"doc_id":127919,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Document Submitted toInitiate E.O. 12866 Review - Lime Manufacturing Plants NPRM Pass Back No. 2.2","date":"2024-02-09"},{"doc_id":127920,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Documentation of Changes Made During OMB Review Under E.O. 12866 through January 10, 2024 - Lime Manufacturing Plants NPRM","date":"2024-02-09"},{"doc_id":127921,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Document submitted to initiate E.O. 12866 review - Lime Manufacturing Plants NPRM Pass Back Number 1","date":"2024-02-09"},{"doc_id":127922,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Documentation of Changes Made to Pass Back No. 1 During OMB Review Under E.O. 12866 through December 14, 2023 - Lime Manufacturing Plants NPRM","date":"2024-02-09"},{"doc_id":127923,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Document submitted to conclude E.O. 12866 Review - Lime Manufacturing Plants NPRM Pass Back No. 1","date":"2024-02-09"},{"doc_id":127924,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Document Submitted to Conclude E.O. 12866 Review - Lime Manufacturing Plants NPRM Pass Back No. 2.2","date":"2024-02-09"},{"doc_id":167422,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Cost Impacts for the Lime Manufacturing Plants Industry Supplemental Proposal","date":"2024-02-09"},{"doc_id":167423,"source":"docket_item","org":"EPA","doc_type":"data","title":"Dose Response Value Library","date":"2024-02-09"},{"doc_id":167424,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Maximum Achievable Control Technology (MACT) Floor Analysis for the Lime Manufacturing Plants Industry Supplemental Proposal","date":"2024-02-09"},{"doc_id":167425,"source":"docket_item","org":"EPA","doc_type":"report","title":"Appendix A: Materials Shared with Small Entity Representatives for the Panel Outreach Meeting held on August 3, 2023","date":"2024-02-09"},{"doc_id":167426,"source":"docket_item","org":"EPA","doc_type":"data","title":"PLS Confidential Business Information (CBI) Submittal","date":"2024-02-09"},{"doc_id":167427,"source":"docket_item","org":"EPA","doc_type":"report","title":"Appendix B: Written Comments Submitted by Small Entity Representatives following the Panel Outreach Meeting on August 3, 2023","date":"2024-02-09"},{"doc_id":167428,"source":"docket_item","org":"EPA","doc_type":"data","title":"Lime Manufacturing Source Category HBEL Support Document","date":"2024-02-09"},{"doc_id":167429,"source":"docket_item","org":"EPA","doc_type":"data","title":"Revised lime facility information after census block changes","date":"2024-02-09"},{"doc_id":167430,"source":"docket_item","org":"EPA","doc_type":"data","title":"Emission Locations","date":"2024-02-09"}],"references":[{"citation_id":1714419,"raw_reference":"MKS-2010 - FTIR N/A - By Difference of Typical Impurities Servomex DF-550e - Electrolytic Cell/Electrochemical This analysis of the product described herein was prepared by Praxair Distribution , Inc. using instruments whose calibration is certified using Praxai r Distribution, Inc. Reference Materials which are either prepared by weights traceable to the National Institute of Standards and Technology (NIST), Measurement Canada, or by using NIST Standard Reference Materials where available. Note: All expressions for concentration (e.g. , % or ppm) are for gas phase, by volume (e.g., ppmv) unless otherwise noted. Analytical uncertanity is expressed as a Relative % unless otherwise noted.","cited_authors":null,"cited_year":null,"cited_title":"MKS-2010 - FTIR N/A - By Difference of Typical Impurities Servomex DF-550e - Electrolytic Cell/Electrochemical This analysis of the product described herein was prepared by Praxair Distribution , Inc","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1714420,"raw_reference":"PGVP Number: Gas Code: E03NI76E15A0295 CC505095 124 - Tooele (SAP) - UT B72019 CO2,O2,BALN Expiration Date: Reference Number: Cylinder Volume: Cylinder Pressure: Valve Outlet: Certification Date: Feb 06, 2027 153-401417362-1 152.5 CF 2015 PSIG Feb 06, 2019 Certification performed in accordance with “EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards (May 2012)” document EPA 600/R-12/531, using the assay procedures listed. Analytical Methodology does not require correction for analytical interference. This cylinder has a total analytical uncertainty as stated below with a confidence level of 95%. There are no significant impurities which affect the use of this calibration mixture. All concentrations are on a volume/volume basis unless otherwise noted. Do Not Use This Cylinder below 100 psig, i.e. 0.7 megapascals.","cited_authors":"PGVP Number: Gas Code: E03NI76E15A0295 CC505095 124 - Tooele (SAP) - UT B72019 CO2,O2,BALN Expiration Date: Reference Number: Cylinder Volume: Cylinder Pressure: Valve Outlet: Certification Date: Feb 06, 2027 153-401417362-1 152.5 CF 2015 PSIG Feb 06, 2019 Certification performed in accordance with “EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards (May","cited_year":"2012","cited_title":"” document EPA 600/R-12/531, using the assay procedures listed","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1714421,"raw_reference":"CALIBRATION STANDARDS Type Lot ID NTRM NTRM 13060628 98051217 Cylinder No CC413727 SG9166746BAL Concentration Uncertainty 13.359 % CARBON DIOXIDE/NITROGEN 7.015 % OXYGEN/NITROGEN 0.6% 0.7% Expiration Date May 09, 2019 Mar 07, 2019","cited_authors":null,"cited_year":null,"cited_title":"CALIBRATION STANDARDS Type Lot ID NTRM NTRM 13060628 98051217 Cylinder No CC413727 SG9166746BAL Concentration Uncertainty 13.359 % CARBON DIOXIDE/NITROGEN 7.015 % OXYGEN/NITROGEN 0.6% 0.7% Expiration Date May 09, 2019 Mar 07, 2019","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1714422,"raw_reference":"ANALYTICAL EQUIPMENT Instrument/Make/Model Analytical Principle Last Multipoint Calibration Horiba VIA-510 SV4MEUTJ CO2 Horiba MPA-510 W603MM58 O2 CO2 NDIR (Dixon) O2 Paramagnetic (Mason) Jan 24, 2019 Jan 10, 2019","cited_authors":null,"cited_year":null,"cited_title":"ANALYTICAL EQUIPMENT Instrument/Make/Model Analytical Principle Last Multipoint Calibration Horiba VIA-510 SV4MEUTJ CO2 Horiba MPA-510 W603MM58 O2 CO2 NDIR (Dixon) O2 Paramagnetic (Mason) Jan 24, 2019 Jan 10, 2019","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}