Horsham, Montgomery County, Pennsylvania 0.14 Groundwater 2021 Boodoo 2018a; Boodoo et al. 2019;
HWSA 2021 reported Not reported reported Boodoo 2018a; Boodoo 2018b Location City of Stuart, Florida Warminster Municipal Authority,
Therefore, it should be possible to reliably manage the impact of competition among anions, including the potential for chromatographic peaking, through piloting, selection of design parameters, and operational monitoring. As discussed in Section 3.6.3, for purposes of estimating national costs, EPA used a method to estimate bed life that explicitly includes consideration of total influent PFAS concentration. The inclusion of total PFAS concentration is intended to account for competition among PFAS compounds. The method to estimate bed life also is based on data from experiments where other competing anions, specifically nitrate and sulfate, were present in concentrations typical of drinking water. 3.4 Pre- and Post-Treatment Needs In general, IX treatment can increase treated water corrosivity because of chloride ion addition and/or carbonate along with bicarbonate removal (Gottleib and Watkins, 2012). For example, Berlien (2003) reported this problem with a full-scale application of IX for perchlorate treatment.
PFAS compounds. 3.6.1 Empty Bed Contact Time For a given set of site-specific conditions, there is a minimum EBCT required to produce water of a target quality. EBCT, measured in minutes, is defined by the following equation: 𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸 (𝑖𝑖𝑖𝑖 𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚) = 𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉 𝑜𝑜𝑜𝑜 𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅 𝐵𝐵𝐵𝐵𝐵𝐵 𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉 𝐹𝐹𝐹𝐹𝐹𝐹𝐹𝐹 𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅 (𝑝𝑝𝑝𝑝𝑝𝑝 𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚) Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 The minimum EBCT required varies depending on the specific contaminant treated, the required contaminant removal percentage, the type of resin used, and other influent water characteristics (e.g., the presence of competing chemical species). Limited data are available on the EBCT employed at full-scale anion exchange systems that are purpose-built for PFAS removal. One pilot system was later permitted for permanent operation using two vessels in series with a total
EBCT of 5.6 minutes (Boodoo et al., 2019). A common vendor recommendation is to use a total
EBCT of 3 to 6 minutes (Boodoo, 2019; Boodoo et al., 2019; Boodoo, 2018; Lombardo et al., 2018). 3.6.2 Vessel Configuration
IX, EPA used data from Zeng et al. (2020). These data are from RSSCTs of IX treating actual Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 groundwater, intended to simulate a full-scale EBCT of 3.3 minutes. The RSSCTs covered six different water quality conditions (different groundwater sources) and two different PFASselective resins. In each groundwater source, multiple PFAS compounds were present in concentrations typical of PFAS-contaminated drinking water. PFAS compounds monitored in the
EPA recognizes that PFAS breakthrough curves are not linear. However, to develop the equations, EPA specifically used the data from the last point of non-detection to the first instance of complete breakthrough (or the end of the study, whichever came first). By limiting the data to this range, EPA sought to characterize the portion of the breakthrough curve where bed life changes rapidly with removal efficiency. This portion of the curve is most interest in selecting a target bed life for purposes of cost estimating and is expected to be more approximately linear than the curve overall. Figure 3-4 shows this concept graphically in relation to a typical theoretical breakthrough curve. Figure 3-4. Linear Bed Life Estimate in Relation to a Typical Breakthrough Curve The resulting PFAS compound-specific bed life equations for IX take the following form: 𝐵𝐵𝐵𝐵𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐,𝐼𝐼𝐼𝐼 = 𝐴𝐴𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃 × 𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡 + 𝐴𝐴𝑅𝑅,𝐼𝐼𝐼𝐼 × %𝑅𝑅𝑐𝑐𝑜𝑜𝑜𝑜𝑜𝑜𝑜𝑜𝑜𝑜 + 𝐵𝐵𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐,𝐼𝐼𝐼𝐼 10 EPA was not able to develop a breakthrough relationship for this compound. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Where: BVcontam,IX = IX bed life for a given PFAS contaminant in BV PFAStotal = total influent concentration of PFAS compounds in ng/L %Rcontam = target percent removal of a given PFAS as a decimal (e.g., 0.8, 0.95)
BPFHxS, and BPFOS) were not significantly different from each other statistically. All compounds share the same slope term (APFAS) for total influent PFAS (in ng/L) and the same slope term (AR) for percent removal of the PFAS compound (as a decimal) and because specifying the model this way results in a consistent order of breakthrough across the range of possible influent PFAS values and percent removal values. The model has an adjusted R2 of 0.71. The overall model and individual coefficients are statistically significant. Although the effect of total PFAS concentration on bed life (APFAS) is small, it remains statistically significant and is included in the model to account for competition among PFAS compounds. Note that the equations are valid only up to a total influent PFAS of 7,044 ng/L, the maximum value in the data set used. Other competing anions, specifically nitrate and sulfate, were present in the water sources studied and measured by Zeng et al. (2020).
HFPO-DA into the IX model. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Because the equations are based on pooled data, they reflect central tendency results under varying water quality conditions. As such, the EPA believes they represent the best approach for estimating national cost given the data currently available in the literature. However, these equations should not be used in lieu of site-specific engineering analyses or pilot studies to guide the design or operation of specific treatment systems. The use of RSSCTs to predict IX performance for PFAS removal is a recent development (Najm et al., 2021; Schaefer et al., 2019; Zeng et al., 2020), so there are no validated methods to scale up from these bench-scale results. When RSSCTs are used to estimate the performance of GAC for PFAS, there are concerns that the results may, in some cases, overestimate full-scale bed life (Hopkins, 2021; Kempisty et al., 2019; Meng et al., 2021; Redding et al., 2019). To compensate for the potential for similar overestimation concerns for IX, when applying the bed life equations, EPA did not incorporate the increase in bed life that would be expected from operating multiple vessels in series (see Section 3.6.2). Section 7.2.1 discusses this topic, and the application of the bed life equations generally, in more detail. 3.7 References
Aqueous Vets. 2019. The City of Stuart, Florida Installs 4 MGD Ion Exchange System to Address PFAS Contamination. AVP-0016 Rev.2 9/19/2019. Retrieved from http://www.aqueousvets.com/uploads/9/8/8/7/98870448/avp-0016_pfas_treatment_system__stuart_fl_-_09.19.19.pdf
Arevalo, E., Strynar, M., Lindstorm, A., McMillan, L., and Knappe, D. 2014. Removal of Perfluorinated Compounds by Anion Exchange Resins: Identifying Effective Resin Regeneration Strategies. AWWA Annual Conference and Exposition. Boston, MA.
Berlien, M. J. 2003. La Puente Valley County Water District’s Experience with ISEP Presentation of Carollo Engineers, Inc. and Association of California Water Agencies.
Boodoo, F. 2021. Personal Communication (E-mail). June 7, 2021.
Boodoo, F. 2019. Personal Communication (E-mail). February 22, 2019. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023
Boodoo, F. 2018a. Short & Long Chain PFAS Removal to Non‐Detect Level with Single‐Use PFA694E Resin. Presentation by Purolite Corporation. Retrieved from: https://docs.house.gov/meetings/IF/IF18/20180906/108649/HHRG-115-IF18-20180906SD027.pdf
Boodoo, F. 2018b. Personal Communication (E-mail). July 12, 2018. City of Portsmouth – Department of Public Works. 2019. Portsmouth Water System PFAS Update. Retrieved from: https://www.cityofportsmouth.com/publicworks/water/portsmouthwater-system-pfas-update
Clifford, D., Sorg, T.J., and Ghurye, G.L. 2011. Ion Exchange and Adsorption of Inorganic Contaminants. In Edzwald, J.K. (Ed.), Water Quality & Treatment: A Handbook on Drinking
Dixit, F., Barbeau, B., Mostafavi, S.G., and Madjid, M. 2020. Removal of legacy PFAS and other fluorotelomers: Optimized regeneration strategies in DOM-rich waters. Water Research, 183(2020), 116098. https://doi.org/10.1016/j.watres.2020.116098
Dixit, F., Barbeau, B., Mostafavi, S.G., and Mohseni, M. 2021. PFAS and DOM removal using an organic scavenger and PFAS-specific resin: Trade-off between regeneration and faster kinetics. Science of the Total Environment, 754(2021), 142107. https://doi.org/10.1016/j.scitotenv.2020.142107
Gottlieb, M.C. and Watkins, G.S. 2012. Ion Exchange Applications in Water Treatment. In
Hopkins, Z.R. 2021. Granular Activated Carbon Adsorption of Per- and Polyfluoroalkyl Substances - from Scale-Up to Factors Affecting Performance. Doctoral Dissertation, North Carolina State University. ProQuest Dissertations Publishing. 29004569. Horsham Water and Sewer Authority (HWSA). 2021. PFAS Summary. Retrieved from: https://www.horshamwater-sewer.com/pfas-summary
Jent, H. 2020. Crews near completion on new ion-exchange treatment plant to purify water in Security. The Gazette. Retrieved from: https://gazette.com/news/crews-near-completion-on-newion-exchange-treatment-plant-to-purify-water-in-security/article_2bf7d0ce-0410-11eb-87768306994433b3.html
Conference, Dallas, TX. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023
Kumarasamy, E., Manning, I. M., Collins, L. B., Coronell, O., and Leibfarth, F. A. 2020. Ionic Fluorogels for Remediation of Per-and Polyfluorinated Alkyl Substances from Water. ACS
Liu, C. 2017. Removal of Perfluorinated Compounds in Drinking Water Treatment: A Study of Ion Exchange Resins and Magnetic Nanoparticles. Doctoral Dissertation, University of Waterloo. Retrieved from http://hdl.handle.net/10012/12660
Mohseni, M., Dixit, F., Barbeau, B. 2019. Optimized Regeneration Strategies for Ion Exchange Resins During PFAS Removal from Natural Waters. AWWA Water Quality Technology Conference. Dallas, TX.
Newman, B. and Berry, J. 2019. Case Study: Pilot Testing Synthetic Media and Granular Activated Carbon for Treatment of Poly- and Perfluorinated Alkyl Substances in Groundwater. In Kempisty, D.M, Xing, Y., and Racz, L. (Eds.), Perfluoroalkyl Substances in the Environment:
Schaefer, C.E., Nguyen, D., Ho, P., Im, J., and LeBlanc, A. 2019. Assessing Rapid Small-Scale Column Tests for Treatment of Perfluoroalkyl Acids by Anion Exchange Resin. Ind. Eng. Chem. Res., 2019(58), 9701−9706. https://doi.org/10.1021/acs.iecr.9b00858 U.S. Environmental Protection Agency (USEPA). 2021a. Drinking Water Treatability Database: Perfluorooctanoic Acid. Retrieved from https://tdb.epa.gov/tdb/contaminant?id=10520
Woodard, S., Berry, J., and Newman, B. 2017. Ion exchange resin for PFAS removal and pilot test comparison to GAC. Remediation, 27, 19-27. https://doi.org/10.1002/rem.21515 Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Widefield Water and Sanitation District (WWSD). 2018. From Pilot to Full-Scale: A Case Study for the Treatment of Perfluorinated Compounds (PFCs) with Ion Exchange. AWWA Water Quality Technology Conference, Toronto, ON, Canada.
Zeng, C., Atkinson, A., Sharma, N., Ashani, H., Hjelmstad, A., Venkatesh, K., and Westerhoff, P. 2020. Removing per-and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns. AWWA Water Science, 2(1), e1172. https://doi.org/10.1002/aws2.1172 Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 4.0 Reverse Osmosis and Nanofiltration (RO/NF) 4.1 Operating Principle
EPA’s Drinking Water Treatability Database (USEPA, 2021a; 2021b; 2021c) includes extensive data from the literature on PFAS removal by RO and NF. Results are available from studies conducted in the laboratory, in the field at pilot scale, and in full-scale application, as shown in Table 4-2, Table 4-3, and Table 4-4. 12 These tables present the number of studies at each scale, along with a key benchmark of technology effectiveness: maximum removal efficiency. Removal efficiency is the percentage of the influent concentration removed through treatment. 12 Data shown in these tables are as of December 2021. EPA frequently updates the Drinking Water Treatability Database, so parties interested in results from recently published literature may wish to access the database directly at https://tdb.epa.gov/tdb/home. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Table 4-2. Studies of RO/NF Treatment for Carboxylate PFAS Number Carbons Number of Bench Studies Number of Pilot Studies Number of Fullscale Studies Maximum Removal Efficiency Maximum Removal Efficiency
PFBA 99.9 Lipp et al. 2010 PFPeA Horst et al. 2018; Liu et al. 2021; Dickenson and Higgins 2016 PFHxA 99.2 Liu et al. 2021 PFHpA Steinle-Darling et al. 2008; Liu et al. 2021
PFOA 99.9 99.9 Boonya-Atichart et al. 2016; Lipp et al. 2010
PFNA Steinle-Darling et al. 2008; Dickenson and Higgins 2016; Appleman et al. 2014
PFDA Steinle-Darling et al. 2008; Dickenson and Higgins 2016; Appleman et al. 2014 PFUnA Steinle-Darling et al. 2008; Dickenson and Higgins 2016; Appleman et al. 2014 PFDoA Dickenson and Higgins 2016; Appleman et al. 2014
PFAS Compound Source(s) for Maximum Removal Efficiency - = no data; NF = nanofiltration; RO = reverse osmosis Sources: USEPA, 2021a; 2021c Table 4-3. Studies of RO/NF Treatment for Sulfonate PFAS Number Carbons Number of Bench Studies Number of Pilot Studies Number of Fullscale Studies Maximum Removal Efficiency Maximum Removal Efficiency PFPrS Liu et al. 2021
PFBS 99.8 99.8 Lipp et al. 2010 PFPeS Liu et al. 2021 PFHxS Appleman et al. 2013; Thompson et al. 2011; Liu et al. 2021
PFAS Compound Source(s) for Maximum Removal Efficiency Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Number Carbons Number of Bench Studies Number of Pilot Studies Number of Fullscale Studies Maximum Removal Efficiency Maximum Removal Efficiency PFHpS Liu et al. 2021
PFOS >99.9 99.9 Lipp et al. 2010; 2163 PFDS Steinle-Darling et al. 2008 Source(s) for Maximum Removal Efficiency
PFAS Compound Source(s) for Maximum Removal Efficiency - = no data; NF = nanofiltration; RO = reverse osmosis Sources: USEPA, 2021b; 2021c Table 4-4. Studies of RO/NF Treatment for Other PFAS
HFPO-DA >64.2 CDM Smith 2018 PFOSA 98.5 Steinle-Darling et al. 2008; Dickenson and Higgins 2016 NMeFOSAA Dickenson and Higgins 2016 N-EtFOSAA Dickenson and Higgins 2016 - = no data; NF = nanofiltration; RO = reverse osmosis Source: USEPA, 2021c The literature demonstrates RO and NF removal efficiencies in the high 90 percent range for nearly all the carboxylate and sulfonate PFAS compounds for which data are available. The literature also shows that the technology often removes these compounds to levels below analytical detection limits. For PFOA and PFOS, maximum removal efficiencies are greater than 99 percent to levels lower than the regulatory thresholds currently under consideration. There are fewer studies of RO/NF performance for other (non-carboxylate and non-sulfonate) PFAS compounds. The apparently low removal values for these other PFAS compounds (e.g., greater than 64.2 percent removal for HFPO-DA) are an artifact of low influent levels relative to the detection or quantitation limits. As discussed below, higher removals than the values shown in Table 4-3 could be achievable for other PFAS that are similar in size and weight to the carboxylate and sulfonate compounds. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023
PFAS removal efficiency for specific membranes appears to be closely related to the characteristics of the membrane relative to the molecular weight of the target compound. For example, Yu et al. (2016) found only 55 percent removal of PFOS by a membrane with a membrane with a molecular weight cutoff (MWCO) of 1,000 grams per mole (g/mol), which is larger than the molecular weight of PFOS (500.13 g/mol). In the same study, a membrane with an MWCO of 200 g/mol achieved 95.5 to 97 percent removal of PFOS. Appleman et al. (2013) and Steinle-Darling and Reinhard (2008) also observed the effect of molecular weight on PFAS removal by NF, finding somewhat lower removal of lower molecular weight, shorter chain PFAS than higher molecular weight, longer chain PFAS. Accordingly, PFAS removal efficiency by NF membranes is not expected to vary substantially by functional group or chain length except to the extent that these factors influence molecular size and weight. RO membranes have a lower
Taylor, 2011). SDI measures the fouling potential of suspended solids. Manufacturers typically specify maximum SDIs of 3 to 5 for RO and NF elements (Bergman et al., 2012). In addition, it is important to model and conduct pilot studies to assess the potential for fouling from substances such as natural organic matter, calcium carbonate, silica, calcium fluoride, barium sulfate, calcium sulfate, strontium sulfate, and calcium phosphate. The Langelier saturation index (LSI), described in ASTM standard D3738, characterizes the potential for CaCO3 scaling. The
WWTP Dickenson and Higgins, 2016 Full Scale RO
WWTP 11.6 Dickenson and Higgins, 2016 Bench Scale NF 10 to 44 Bench Scale RO 17.6 to 23.5 Lipp et al., 2010 Bench Scale NF 6 to 41 Lipp et al., 2010 Appleman et al., 2013 gfd = gallons per square foot per day; NF = nanofiltration; RO = reverse osmosis; WWTP = potable reuse facility receiving water from wastewater treatment plant 4.6.3 Recovery Rate As discussed in Section 4.1, the recovery rate is the percentage of the influent flow that is recovered as permeate. Increasing the recovery rate will increase the concentration of dissolved solids in the membrane reject water and will thus increase the required feed pressure and the potential for membrane scaling. Thus, the achievable recovery rate depends on the quality of the source water as well as the pretreatment of the water, and systems with high levels of total dissolved solids in their feed water will typically operate at lower recovery rates than systems with lower levels. As shown in Table 4-6, recovery rates found in the literature range from 78 to 92 percent. Table 4-6. Recovery Rates for PFAS Treatment Reported in the Literature Study Scale and Membrane Type Source Water Recovery Rate Source(s) Full Scale RO
WWTP Thompson et al., 2011 Full Scale RO WWTP Dickenson and Higgins, 2016 Full Scale RO
WWTP Dickenson and Higgins, 2016 Full Scale RO Surface
Wetzel, 2021; WHNT News, 2019 Pilot Scale NF Ground Franke et al., 2019 Full Scale RO Surface 85 to 92% Bench Scale NF Ground Dowbiggin et al., 2021 Boonya-Atichart et al., 2016
NF = nanofiltration; RO = reverse osmosis; WWTP = potable reuse facility receiving water from wastewater treatment plant Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 4.7 References