Policy Replication

Technical Support Document - Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water

Docket document2023-03-29 · EPA · publication · EPA-HQ-OW-2022-0114-0038
RIN 2040-AG18 · Docket EPA-HQ-OW-2022-0114

Other documents for the same rulemaking (all, by stage)

2022-03-28 Docket documentProposed PFAS NPDWR EJ Public Meetings Presentation - FINAL
2022-04-20 Docket documentMarch 2022 Proposed PFAS NPDWR EJ Public Meeting Summary - Final
2022-04-20 Docket documentProposed PFAS NPDWR EJ Public Meetings Presentation Apr 5 2022 Meeting - Final
2022-09-12 Docket documentApril 2022 Proposed PFAS NPDWR EJ Public Meeting Summary - Final
2023-03-29 Federal RegisterPFAS National Primary Drinking Water Regulation Rulemaking
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS National Primary Drinking Water Regulation - Chapter 6.5 - Lipids Meta-Analysis
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS National Primary Drinking Water Regulation
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS National Primary Drinking Water Regulation - Chapter 6.7 - Disinfection Byproducts
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS National Primary Drinking Water Regulation - Chapter 6.5 - Auxiliary CVD Analyses 01 02
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS National Primary Drinking Water Regulation - Chapter 9.12 - Small System Compliance Technology (SSCT) Evaluation for Per- and Polyfluoroalkyl Substances (PFAS) (Hazardous Waste)
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS Rule Appendices
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS National Primary Drinking Water Regulation - Chapter 6.4 - Birth Weight Meta-Analysis Code Data
2023-03-29 Regulatory impact analysisEconomic Analysis for the Proposed PFAS National Primary Drinking Water Regulation, Chapter 9.12, Small System Compliance Technology (SSCT) Evaluation for Per- and Polyfluoroalkyl Substances
2023-03-29 Docket documentUSEPA 2010
2023-03-29 Docket documentUS BEA 2022 01 02
2023-03-29 Docket documentEO 12866 1993 01 02
2023-03-29 Docket documentDWQI 2017 D23001
2023-03-29 Docket documentAbt Associates 2020a (US EPA 2004a) 15
2023-03-29 Docket documentMarana Water 2019 09 11
2023-03-29 Docket documentCity of Issaquah 2020 09 11
2023-03-29 Docket documentSEER 2020a appendix 15P23002
2023-03-29 Docket documentMaine Department of Environmental Protection 2020 appendix 15P23002
2023-03-29 Docket documentPFAS VLS Unique Attributes 01 02
2023-03-29 Docket documentStarling et al 2017 D23001
2023-03-29 Docket documentCDM Smith 2018
2023-03-29 Docket documentPage 2020 09 11
2023-03-29 Docket documentNAPA 2017 01 02
2023-03-29 Docket documentNew York City Environmental Protection 2022 01 02
2023-03-29 Docket documentUS EPA 2021 01 02
2023-03-29 Docket documentUS BLS 2021 01 02
2023-03-29 Docket documentAbt Associates 2022a 01 02
2023-03-29 Docket documentUS EPA 2000 01 02
2023-03-29 Docket documentMaine DEP 2020 10
2023-03-29 Docket documentRaucher et al 2019 01 02
2023-03-29 Docket documentVT DEC 2021 10
2023-03-29 Docket documentPADEP 2021 10
2023-03-29 Docket documentCDPHE 2018 10
2023-03-29 Docket documentCDPHE 2020 appendix 01 02
2023-03-29 Docket documentCDC 2017c appendix 01 02
2023-03-29 Docket documentAgency for Healthcare Research and Quality 2017c appendix 01 02
2023-03-29 Docket documentCDC 2015a appendix 01 02
2023-03-29 Docket documentUS EPA 2003 01 02
2023-03-29 Docket documentCDC 2013c appendix 01 02
2023-03-29 Docket documentUS EPA 2016j 01 02
2023-03-29 Docket documentNorth Dakota Department of Environmental Quality 2020 appendix 01 02
2023-03-29 Docket documentWHO 2018 appendix 01 02
2023-03-29 Docket documentUS EPA 2014 01 02
2023-03-29 Docket documentUS EPA 2019b 01 02
2023-03-29 Docket documentWidefield Water and Sanitation District 2018 01 02
2023-03-29 Docket documentUSEPA 2023f
2023-03-29 Docket documentUSEPA 2002
2023-03-29 Docket documentUS EPA 2021b 03 04 05 06 07 08
2023-03-29 Docket documentForrester 2019 09 11
2023-03-29 Docket documentUSEPA 1989
2023-03-29 Docket documentGeorgia EPD 2020 appendix 15P23002
2023-03-29 Docket documentEPA Response to Letter of Peer Review for DBP Reduction as a Result of GAC Treatment for PFOA and PFOS in Drinking Water: Benefits Analysis Related to Bladder Cancer
2023-03-29 Docket documentUSEPA 2021a Perfluorooctanoic Acid 09 11
2023-03-29 Docket documentKlein et al 2018
2023-03-29 Docket documentRaucher et al 2019 01 02
2023-03-29 Docket documentFinal Tribal Summary Report Document 508 Compliant

References: 250 extracted, 0 linked to papers

Page 1Download these results: CSV · JSON
Kurunthachalam, K., Mabury, S.S., and van Leeuwen, S.P. 2011. Perfluoroalkyl and polyfluoroalkyl substances in the environment: terminology, classification, and origins. Integr Environ Assess Manag, 7(4), 513-541. https://doi.org/10.1002/ieam.258 Interstate Technology Regulatory Council (ITRC). 2020. Naming Conventions and Physical and Chemical Properties of Per- and Polyfluoroalkyl Substances (PFAS). Retrieved from https://pfas1.itrcweb.org/fact_sheets_page/PFAS_Fact_Sheet_Naming_Conventions_April2020.pdf National Center for Biotechnology Information (NCBI). 2021a. PubChem Compound Summary for CID 9554, Perfluorooctanoic acid. Retrieved from https://pubchem.ncbi.nlm.nih.gov/compound/9554#section=2D-Structure
journal articleNot linked to a paper · refsec · cited link
NCBI. 2021b. PubChem Compound Summary for CID 74483, Perfluorooctanesulfonic acid. Retrieved from https://pubchem.ncbi.nlm.nih.gov/compound/Perfluorooctanesulfonicacid#section=2D-Structure
research reportNot linked to a paper · refsec · cited link
Rogers, R.D., Reh, C.M., and Breysse, P. 2021. Advancing per- and polyfluoroalkyl substances (PFAS) research: an overview of ATSDR and NCEH activities and recommendations. J Expo Sci Environ Epidemiol, 31(6), 961-971. https://doi.org/10.1038/s41370-021-00316-6 U.S. Environmental Protection Agency (USEPA). 2021a. Drinking Water Treatability Database: Per- and Polyfluoroalkyl Substances. Retrieved from https://tdb.epa.gov/tdb/contaminant?id=11020
journal articleNot linked to a paper · refsec · cited link
USEPA. 2021b. Drinking Water Treatability Database: Perfluorooctane Sulfonate. Retrieved from https://tdb.epa.gov/tdb/contaminant?id=10940 Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023
datasetNot linked to a paper · refsec · cited link
USEPA. 2021c. Drinking Water Treatability Database: Perfluorooctanoic Acid. Retrieved from https://tdb.epa.gov/tdb/contaminant?id=10520
datasetNot linked to a paper · refsec · cited link
USEPA. 2021d. CompTox Chemicals Dashboard: PFAS structures in DSSTox (update August 2021). Retrieved from https://comptox.epa.gov/dashboard/chemical-lists/PFASSTRUCTv4
research reportNot linked to a paper · refsec · cited link
Weaver, J. 2020. PFAS should be managed as a single class of chemicals, experts say. Environmental Factor. National Institute of Environmental Health Sciences. Retrieved from https://factor.niehs.nih.gov/2020/8/papers/pfas/index.htm Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 2.0 Granular Activated Carbon (GAC) 2.1 Operating Principle
research reportNot linked to a paper · refsec · cited link
GAC beds typically also require periodic backwash to prevent head loss or biomass accumulation. The backwash process must be designed to remove accumulated solids, while preventing the spent carbon at the top of the column from mixing with the unspent carbon at the bottom, creating a mixed bed and the possibility of “leakage” of the target contaminant. 4 The terms “reactivation” and “regeneration” are sometimes used interchangeably in the drinking water industry. GAC vendors, however, make a distinction between the two processes. The appropriate term for the process used on spent GAC containing adsorbed PFAS is reactivation (Matthis and Carr, 2018). Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Figure 2-1. Conceptual Diagram of the GAC Treatment Process The specific design of a GAC treatment facility depends on the type of contactor and the system configuration used. GAC can be set up in a single-stage, series, or parallel system. In drinking water treatment, GAC configuration generally is a downflow fixed (packed) bed system. The system can have single or multiple adsorbers operated under pressure or fed by gravity (Brady and Moran, 2012; Summers et al., 2011). Pressure contactors are more cost effective for small systems because they can be purchased off the shelf as prefabricated, packaged units. Pressure
research reportNot linked to a paper · refsec
GAC systems can be operated at higher suspended solids concentrations with less frequent backwashing and over a wide range of flow rates due to the allowable pressure variances. Pressure GAC systems are also enclosed, so there is no visual observation of the system. Gravity contactor designs are generally used in larger installations (Brady and Moran, 2012; Summers et al., 2011). Gravity contactors can be sized larger than off-the-shelf pressure vessels and because common wall design can minimize space requirements. A gravity contactor design is better for systems that do not have large variances in flow, pressure, or turbidity (Summers et al., 2011). Figure 2-2 and Figure 2-3, respectively, provide schematic drawings for a pressure GAC facility and a gravity GAC facility. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Figure 2-2. Typical Schematic Layout for Pressure GAC Treatment Facility Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Figure 2-3. Typical Schematic Layout for Gravity GAC Treatment Facility 2.2 Effectiveness for PFAS Removal 2.2.1 Removal Efficiency
research reportNot linked to a paper · refsec
PFBA 99.5 Westreich et al. 2018 PFPeA Appleman et al. 2013; McCleaf et al. 2017; Park et al. 2017; Lombardo et al. 2018; Kempisty et al. 2019; Liu et al. 2019; Park et al. 2020 PFHxA 99.5 Westreich et al. 2018 PFHpA Zeng et al 2020
research reportNot linked to a paper · refsec
PFOA >99.8 Forrester and Bostardi 2019 PFNA Zeng et al 2020
research reportNot linked to a paper · refsec
PFDA Appleman et al. 2013 PFUnA McCleaf et al. 2017 PFDoA McCleaf et al. 2017; Park et al. 2017 PFTriA McCleaf et al. 2017
research reportNot linked to a paper · refsec
PFAS Compound Sources: USEPA, 2021a; 2021c Source(s) for Maximum Removal Efficiency Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Table 2-2. Studies of GAC Treatment for Sulfonate PFAS Number Carbons Number of Bench Studies Number of Pilot Studies Number of Full-scale Studies Maximum Removal Efficiency PFPrS Liu et al. 2019
datasetNot linked to a paper · refsec
PFBS 99.5 Westreich et al. 2018 PFPeS Liu et al. 2019 PFHxS 99.5 Westreich et al. 2018 PFHpS Belkouteb et al. 2020
research reportNot linked to a paper · refsec
PFAS Compound Source for Maximum Removal Efficiency Sources: USEPA, 2021b; 2021c Table 2-3. Studies of GAC Treatment for Other PFAS
datasetNot linked to a paper · refsec
PFMOAA FtS 4:2 Not reported PFBSA Yan et al. 2020 PFO2HxA Hopkins et al. 2018 PFO3OA Hopkins et al. 2018 FtS 6:2 Casey et al. 2018
research reportNot linked to a paper · refsec
HFPO-DA Hopkins et al. 2018 PFHxSA Rodowa et al. 2020 PFO4DA Hopkins et al. 2018 Nafion BP2 Hopkins et al. 2018 FtS 8:2 Woodard et al. 2017
research reportNot linked to a paper · refsec
For GAC, chain length appears to be the more important factor, followed by functional group. The results from Berretta et al. (2021) provide an example of a typical order of breakthrough. 6 A related measure is carbon use rate, which is often expressed in units of pounds of carbon used per 1,000 gallons of water treated. A lower carbon use rate reflects a longer bed life and more effective treatment. To avoid confusion, this document does not present data on carbon use rate. Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 From earliest breakthrough to latest, this typical sequence is as follows (with number of carbon atoms shown in parenthesis for ease of reference):
research reportNot linked to a paper · refsec
Gustavus, Alaska reported Groundwater 20182019 Alaska Community Action on Toxics 2019 Airline/Lambert Water Treatment Campus,
research reportNot linked to a paper · refsec
Marana, Pima County, Arizona reported Groundwater reported Marana Water 2019 Liberty Utilities, Litchfield Park, Arizona 1.58 Groundwater 2017
research reportNot linked to a paper · refsec
ADEQ 2021; Forrester 2019 Picture Rocks Water Treatment Campus,
research reportNot linked to a paper · refsec
Marana, Pima County, Arizona reported Groundwater reported Marana Water 2019 Municipal Services Commission of the City of New Castle, New Castle, Delaware 0.50 Groundwater 2015 Mordock 2016; Forrester 2019 Location Moose Creek, Fairbanks North Star
research reportNot linked to a paper · refsec
Borough, Alaska Sources Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Flow rate (MGD) Groundwater or Surface Water Year of Startup Emerald Coast Utilities Authority,
research reportNot linked to a paper · refsec
Pensacola, Escambia County, Florida 1.44 Groundwater 2017 Robinson 2018; Forrester 2019 Rome Water and Sewer Division, Rome, Georgia Groundwater reported Forrester 2019; City of Rome 2019 Former Naval Air Station, Brunswick, Maine reported Not reported 2011 Danko 2018
research reportNot linked to a paper · refsec
Kennebunk, Kennebunkport & Wells Water District, Kennebunk, Maine 2.90 Groundwater 2020 Berretta et al. 2021; Business Wire 2018 Mary Dunn Water Supply Wells, Hyannis & Town of Barnstable, Massachusetts 1.44 Groundwater 2015 Gallagher 2017; Forrester 2019 City of Westfield Department of Public
research reportNot linked to a paper · refsec
Works, Westfield, Massachusetts reported Groundwater 2018 Westfield 2019 Plainfield Township, Kent County, Michigan Groundwater 2018 Biolchini 2018 Ann Arbor Water Treatment Plant, Ann
research reportNot linked to a paper · refsec
Arbor, Michigan Surface Water 2018 Stanton 2019; Page 2020 Oakdale Public Works, Oakdale, Minnesota Groundwater 2006
research reportNot linked to a paper · refsec
MDH 2010; ATSDR 2008 Merrimack Village District Water Works,
research reportNot linked to a paper · refsec
Merrimack, Hillsborough County, New Hampshire reported Groundwater 2020 Cronin 2020 Pease International Tradeport Drinking Water System, Portsmouth, New Hampshire 0.72 Groundwater 2019 City of Portsmouth 2020; Forrester 2019 Montclair Water Bureau, Montclair, New Jersey 0.72 Groundwater reported Forrester 2019; PFAS Project Lab 2021 Passaic Valley Water Commission,
research reportNot linked to a paper · refsec
Garfield, New Jersey Groundwater reported Forrester 2019; Sobko 2021 Hampton Bays Water District, Suffolk
research reportNot linked to a paper · refsec
County, New York Groundwater 2018 Gordon 2018 Suffolk County Water Authority, New York reported Groundwater 2017
research reportNot linked to a paper · refsec
SCWA 2018 Town of Petersburgh Water District, Petersburgh/Rensselaer County, New York 0.07 Not reported 2017 Forrester 2019; NYS DEC 2020a Washington Lake Filtration Plant,
research reportNot linked to a paper · refsec
Newburgh, New York 8.86 Groundwater 2017 Forrester 2019; NYS DEC 2020b reported Groundwater 2007 Cummings et al 2015 1.01 Groundwater reported Forrester 2019; NYS DEC 2021 Location Little Hocking Water Association, Little
research reportNot linked to a paper · refsec
Hocking, Ohio Village of Hoosick Falls, New York Sources Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Flow rate (MGD) Groundwater or Surface Water Year of Startup Sweeny Water Treatment Plant, Cape Fear Public Utilities Authority, North Carolina Surface Water 2022 Vandermeyden and Hagerty 2020 Wright-Patterson Air Force Base, Dayton, Ohio 2.74 Groundwater 2017 Barber 2017; Forrester 2019 Aqua Pennsylvania, Chalfont Borough, Pennsylvania 0.58 Groundwater reported Forrester 2019; Chalfont Borough 2021 Horsham Water and Sewer Authority,
research reportNot linked to a paper · refsec
Horsham, Montgomery County, Pennsylvania 1.44 Groundwater 2017 Boodoo et al. 2019; Montgomery News 2017; Forrester 2019 Warrington Township Water and Sewer
research reportNot linked to a paper · refsec
Department, Warrington, Pennsylvania 0.58 Groundwater reported Forrester 2019; Warrington Township 2017 City of El Campo Water Department, El
government reportNot linked to a paper · refsec
Campo, Texas reported Groundwater 2017 Sullivan 2018 Airway Heights Water System, City of Airway Heights, Washington reported Groundwater 2018
research reportNot linked to a paper · refsec
ATSDR 2020 Joint Base Lewis-McChord, Washington reported Groundwater reported Sullivan 2018 4.32 Groundwater 2016 City of Issaquah 2020; Mende 2019; Kwan and York 2017 reported Not reported reported
research reportNot linked to a paper · refsec
USEPA 2009 Location Issaquah, Washington Parkersburg Utility Board, Parkersburg, West Virginia Sources
research reportNot linked to a paper · refsec
MGD = million gallons per day 2.3 Raw Water Quality Considerations Natural organic matter, often measured as dissolved organic carbon (DOC) or total organic carbon (TOC), can interfere with GAC’s capacity to adsorb PFAS (Appleman et al., 2013; Ateia et al., 2019; Berretta et al., 2021; Gagliano et al., 2020; Kothawala et al., 2017). The significance of this interference may depend on the specific type of natural organic matter present (Gagliano et al., 2020; Kothawala et al., 2017). However, in general, it does not necessarily reduce the maximum removal effectiveness of GAC. Instead, it shortens the time to breakthrough, meaning more frequent GAC replacement can be required at higher TOC concentrations, all other factors being equal. Therefore, it should be possible to reliably manage the impact of natural organic matter through piloting, selection of design parameters, and operational monitoring. For purposes of estimating national costs for GAC, EPA used a method to estimate bed life that explicitly includes consideration of influent TOC (see Sections 2.6.3 and 7.2.1). The presence of other adsorbable contaminants can reduce GAC capacity for a target contaminant, as the contaminants compete for adsorption sites on the media. The extent of this competition depends on the relative concentrations and adsorbability of the contaminants.
research reportNot linked to a paper · refsec
However, when a poorly adsorbed contaminant is present and not a treatment target, the system can allow the contaminant to breakthrough, reducing its impact on GAC capacity for the target Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 contaminant(s) (Stenzel and Merz, 1989). When multiple target contaminants (e.g., multiple
research reportNot linked to a paper · refsec
PFAS compounds) are present, GAC operation, specifically the selection of bed life, should consider competition among these contaminants. In extreme cases, where the GAC bed becomes highly saturated with contaminants, preferred contaminants in the influent can displace previously adsorbed, less preferred contaminants. Such cases can result in a phenomenon known as chromatographic peaking, where the treated concentration of a less preferred contaminant exceeds its influent concentration (Brady and Moran, 2012). Appleman et al. (2014) reported this phenomenon for PFBA at a full-scale GAC system removing PFAS. McCleaf et al. (2017) observed similar behavior for PFBA and PFPeA in column tests. Like TOC, the impact of competition among target contaminants, including the potential for chromatographic peaking, can be managed through piloting, selection of design parameters, and operational monitoring. For purposes of estimating national costs for GAC, EPA used a method to estimate bed life that is based on data from studies where multiple PFAS compounds were present in concentrations typical of PFAS-contaminated drinking water (see Sections 2.6.3 and 7.2.1). 2.4 Pre- and Post-Treatment Needs Because GAC also works as a filtration medium, solids in influent water can accumulate in the
research reportNot linked to a paper · refsec
GAC bed, causing excess pressure drop and increased backwash frequency. Therefore, under some circumstances, pre-filtration should be included. Such circumstances are site-specific, but examples include when upstream treatment includes coagulant addition for solids removal or when there is the potential for formation of iron and manganese precipitates (Stenzel and Merz, 1989; Summers et al., 2011). Chlorination prior to GAC treatment is not generally recommended because of the potential for the chlorine compounds to react with adsorbed compounds or the
research reportNot linked to a paper · refsec
EPA’s cost estimates. Values for other GAC design parameters (e.g., loading rate, backwash frequency), while not specifically addressed here, are well documented for GAC treatment in general. EPA has no reason to expect a significant difference in these parameters for GAC systems treating PFAS compounds. 2.6.1 Empty Bed Contact Time For a given set of site-specific conditions, there is a minimum EBCT required to produce water of a target quality. EBCT, measured in minutes, is defined by the following equation: Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸 (𝑖𝑖𝑖𝑖 𝑚𝑚𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖) = 𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉 𝑜𝑜𝑜𝑜 𝐺𝐺𝐺𝐺𝐺𝐺 𝐵𝐵𝐵𝐵𝐵𝐵 𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉 𝐹𝐹𝐹𝐹𝐹𝐹𝐹𝐹 𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅 (𝑝𝑝𝑝𝑝𝑝𝑝 𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚) The minimum EBCT required varies depending on the specific contaminant treated, the required contaminant removal percentage, the type of GAC used, and other influent water characteristics. Full-scale GAC treatment systems that are purpose-built for PFAS removal and for which EBCT data are available use EBCTs between 7.6 and 26 minutes (Appleman et al., 2014; Boodoo, 2018; Forrester and Mathis, 2018; Kwan and York, 2017; Vandermeyden and Hagerty, 2020).
government reportNot linked to a paper · refsec
GAC vendors commonly recommend a minimum EBCT of 20 minutes for PFAS removal (Calgon Carbon, 2018; Forrester and Mathis, 2017; 2018). 2.6.2 Contactor Configuration
research reportNot linked to a paper · refsec
Calgon Carbon, 2018; Forrester and Mathis, 2017; 2018). Gravity systems typically do not use series operation. 2.6.3 Bed Life As discussed in Section 2.2.2, GAC bed life depends on a number of factors. Designers should select EBCT and contactor configuration to maximize bed life. Although bed life data are available from full-scale systems removing PFAS, these data are of limited usefulness because of one or more of the following factors: Technologies and Cost for Removing Per- and Polyfluoroalkyl Substances (PFAS) from Drinking Water February 2023 Influent PFAS concentrations that are highly variable over time, with frequent non-detections A limited number of PFAS compounds monitored
research reportNot linked to a paper · refsec
TOC (mg/L) Burkhardt et al., 2022 Pilot 1.8 to 3.2(a)
government reportNot linked to a paper · refsec
PFHxS, PFOS, PFNS(b), HFPO-DA(c) Liu et al., 2019 Pilot 2.7(d) PFPeA(b), PFHxA, PFHpA, PFOA, PFPrS(b), PFBS, PFPeS(b), PFHpS(b),
research reportNot linked to a paper · refsec
PFHxS, PFOS McNamara et al., 2018 CD-RSSCT 1.42
research reportNot linked to a paper · refsec
PFOA, PFOS Park et al., 2020 CD-RSSCT 0.53 and 0.78 PFPeA(b), PFHxA, PFHpA, PFOA, PFBS,
research reportNot linked to a paper · refsec
Next →