US EPA. 1999b. Technologies and Costs for the Removal of Arsenic From Drinking Water. Prepared by International Consultants, Inc. and Malcolm Pirnie, Inc. under contract 68-C-C6–0039 with EPA OGWDW. April 1999. 392 pp.. [W-99-16-II-B-10]
Other documents for the same rulemaking (all, by stage)
References: 136 extracted, 0 linked to papers
TDS/As Ratio: NR 2,800 Hathaway and Rubel (1987)
Fox (1989) B Ionac ASB-1 land | Dowex 11 Bed Volume: 0.014 cu ft Flowrate: NR
TDS/As Ratio: 9200:1 400-500 (projected if oxidation to As(V)is preformed) Clifford and (1985) |« A-300E 1 (bench-scale) 1* A-300E I (full-scale) Bed Volume: 0.0018 cu ft Flowrate: 0.035 gpm
NR = Not Reported 2.4.6 Secondary Effects Chloride-form resins are often used in arsenic removal. Chloride ions are displaced from the column as contaminants (arsenic) are sorbed onto the column. As a result, the potential exists for increases in the chloride concentration of the product water. Increases in chlorides can greatly increase the corrosivity of the product water. Chlorides increase the corrosion potential of iron and as a result increase the potential for red water problems (EPA, 1995). Corrosion problems are 2-23 worsened when high chloride levels are intermittent. In situations where chlorides pose a problem, demineralization, blending, or alternate treatment techniques may be required.
Second, spent brine can be treated by precipitation. Clifford and Lin (1995) have shown that arsenic levels can be substantially reduced using iron and aluminum coagulants as well as lime. Much greater than the stoichiometric amounts (up to 20 times as much), however, are needed in actual practice to reduce arsenic to low levels. In addition, pH adjustment may be necessary to ensure optimum coagulation conditions. Reductionsfrom90 mg As(V)/L to less than 1.5 mg As(V)/L have been seen using iron and aluminum metal salts (Clifford and Lin, 1995). Both coagulant types seem to work well, however, iron precipitates tend to settle better due to their weight. Dried sludge from brine reduced to 1.5 mg As(V)/L using precipitation passed an EP toxicity test with only 1.5 mg/L As(V) in the leachate. In this situation, dried sludge could have been disposed of in a landfill. Reuse of decontaminated regenerant has yet to be evaluated, however, the possibility of reuse does exist. 2-25 2.4.10
EBCT A few studies have been performed to test the effect of EBCT on IX performance. Clifford and Lin (1986) reduced EBCT from 5 to 1.4 in a Hanford, CA study and found no significant reduction in arsenic removal performance. In a recent AWWARF study, four IX columns were run with EBCTs varying between 2.5 and 15 minutes. Data from this study show that the shorter the
EBCT, the more BVs can be treated before breakthrough. The disadvantage to shorter EBCT, however, is increased regeneration frequency. Based on these data, shorter EBCTs may be preferred to reduce capital costs (AWWARF, 1998). 2.4.11 Typical Design Parameters Through extensive research, Clifford and others (1998) assembled typical operating parameters and suggested options for ion exchange processes. Although many design parameters should be tailored to the specific treatment situation, Table 2-2 gives typical values and options.
MEMBRANE PROCESSES 2.5.1 Introduction Membranes are a selective barrier, allowing some constituents to pass and blocking the passage of others. The movement of constituents across a membrane requires a driving force (Le. a potential difference between sides of the membrane). Membrane processes are often classified by the type of driving force, including pressure, concentration, electrical potential, and temperature. The processes discussed here include only pressure-driven and electrical potential-driven types. Pressure-driven membrane processes are often classified by pore size into four categories: microfiltration (MF), ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO). Typical pore size classification ranges are given in Figure 2-1. High-pressure processes (Le., NF and RO) have a relatively small pore size compared to low-pressure processes (Le., MF and UF). Typical pressure ranges for these processes are given in Table 2-3. NF and RO primarily remove constituents through chemical diffusion (Aptel and Buckley, 1996). MF and UF primarily remove constituents through physical sieving. An advantage of high-pressure processes is that they tend to remove a broader range of constituents than low-pressure processes. However, the drawback to broader removal is the increase in energy required for high-pressure processes.
AWWARF (1998) performed bench-scale tests on two low-MWCO UF membranes. Single element testing was performed on Desai GM and FV UF membranes for a spiked, deionized water. Flat sheet testing was also performed on Desai GM, FV, and PM UF membranes for spiked, deionized water. Since the samples were spiked, no particulate or colloidal arsenic was present. Results of this study are given in Table 2-5.
Fox, 1989 Fox and Sorg, 1987 1 Eugene, OR 3-5 gpd 67% recovery 195 psi below MDL
Fox, 1989 Fox and Sorg, 1987 I Fairbanks, AL low-pressure (< 100 psi)
Fox, 1989 Fox and Sorg, 1987 j San Ysidro, NM Pilot (hollow fiber, cellulose acetate) 50% recovery pH adjustment to 6.3 antiscalent addition 93-99% Clifford and Lin, 1991 San Ysidro, NM Pilot (hollow fiber, polyamide) 50% recovery pH adjustment to 6.3 antiscalent addition Clifford and Lin, 1991 San Ysidro, NM 10-15% recovery
Fox, 1989 Fox and Sorg, 1987 Tarrytown, NY Pilot (FilmTec BW30, Hydranautics NCM1, Fluid Systems TCFL) 15 gfd 10% recovery below MDL
Malcolm Pirnie, 1992 Tanytown, NY Rogers, 1989 Charlotte
Huxstep, 1987 Cincinnati, OH As(H_) 73% Fox and Sorg. 1987
ENR Materials Prices 2189.24 BLS numerical values were re-based to 1967 base year (see Section 3.2.5) Table 3-8 Unit and General Cost Assumptions Electricity1 $0.08/kWh Diesel Fuel1 $1.25/galIon Natural Gas1 $0.006/scf Labor2 Large systems: Small systems: Very small systems: Building Energy Use 102.6 kWh/sq ft/yr P Housing Costs $125/sq ft Energy Information Administrauon. Technical Design Panel (EPA, 1998a) $40/hr S28/hr 8 hrs/wk P.85
Brandhuber (1998). "Arsenic Rejection by Nanofiltration and Ultrafiltration Membranes: Arsenic Forms vs. Membrane Properties," AWWA Inorganic Contaminants
Workshop, San Antonio, TX, February 23-24, 1998.
Buckley (1996). "Categories of Membrane Operations," Chapter in Water Treatment Membrane Processes, McGraw Hill, 1996. American Water Works Research
Foundation, Lyonnaise des Eaux, Water Research Commision of South Africa, 1996.
AWWA (1990). Water Quality and Treatment - A Handbook of Community Water Systems. McGraw-Hill Publishing Company, New York.
AWWA (1997). Arsenic Regulation, USEPA, Office of Ground Water and Drinking Water, October 1997.
AWWARF (1996) - Water Treatment Membrane Processes, McGraw-Hill Publishing Company, New York.
AWWARF (1998). Arsenic Treatability Options and Evaluation of Residuals Management Issues.
Amy, G.L., M. Edwards, M. Benjamin, K. Carlson, J. Chwirka, P. Brandhuber, L. McNeill and F. Vagliasindi, Draft Report, April 1998.
Bellack, E. (1971). "Arsenic RemovalfromPotable Water," J. AWWA, 63:7:454-458.
Bennett (1996). "Sorption and Filtration of Metals Using Iron-Oxide Coated Sand," Water Research, 30:11:2609.
Bennett (1998). "Sorption of Arsenic by Various Adsorbents," AWWA Inorganic Contaminants Workshop, San Antonio, TX, February 23-24, 1998. Cadmus Group, Inc. (1998). Cost Evaluation of Small System Compliance Options - Point-of-Use and Point-of-Entrv Treatment Units. Prepared for USEPA Office of Ground Water and Drinking Water.
CH2M Hill (1998). Telephone conversation with Joseph Chwirka, CH2M Hill, Albuquerque, New Mexico.
Ruiz (1994). "Removal of Arsenic by Enhanced Coagulation and Membrane Technology," Proceedings AWWA Annual Conference, New York.
Edwards (1998). "Raw Water QuaUty and Arsenic Treatment," Submitted for Publication in J. AWWA.
Edwards (1996). "Speciation of As in US Waters," Poster Session AWWA Annual
Yang (1994). "Arsenic Species in Groundwaters ofthe Blackfoot Disease Area, Taiwan," Environmental Science and Technology, 28:5:877.
Beuhler (1994). "Enhanced Coagulation for Arsenic Removal," /. AWWA, 9:79-90. Clifford; D., L. Ceber and S.
Chow (1983). "As (III) and As (V) Separation by Chloride-Form Ion Exchange Resins," Proceedings AWWA WQTC, Norfolk, Virginia.
Lin (1985). Arsenic (HI) and Arsenic (V) Removal From Drinking Water in San Ysidro. New Mexico, University of Houston, Houston, Texas.
Clifford, D. and C C Lin (1986). Arsenic Removal From Groundwater in Hanford, California - A Preliminary Report, University of Houston, Department of Civil/Environmental Engineering. Cited in: AWWA (1990). Water Quality and Treatment - A Handbook of Community Water
Clifford, D. (1994). "Computer Prediction of Arsenic Ion Exhange," J. AWWA, 86:4:10.
Clifford, D. and C C Lin (1995). "Ion Exchange, Activated Alumina, and Membrane Processes for Arsenic Removal from Groundwater," Proceedings of the 45th Annual Environmental Engineering Conference, University of Kansas, February 1995.
Tripp (1998). "Arsenic Removal by Ion Exchange With and Without Brine Reuse," AWWA Inorganic Contaminants Workshop, San Antonio, TX, February 2324, 1998. CulpAVesner/Culp (1979). Estimating Water Treatment Costs, Volume 2: Cost Curves Applicable to 1 to 200 mgd Treatment Plants, CWC Engineering, San Clemente, California. CulpAVesner/Culp (1984). Estimation of Small System Water Treatment Costs, CWC Engineering Software (for USEPA), San Clemente, California. CulpAVesner/Culp (1994). WATERCOST Model - A Computer Program for Estimating Water and Wastewater Treatment Costs (Version 2.0), CWC Engineering Software, San Clemente, California.
Tikkanen (1994). "Nationwide and California Arsenic Occurrence Studies," Published in Arsenic Exposure and Health, Chapman and Hall Publishing Company, pp. 31-40. P.87
DPRA, Inc. (1993a). Small Water System Byproducts Treatment "and Disposal Cost Document, Prepared for USEPA Office of Ground Water and Drinking Water.
DPRA, Inc. (1993b). Water System Byproducts Treatment and Disposal Cost Document. Prepared for USEPA Office of Ground Water and Drinking Water.
Hildebrandt (1998). "Granular Ferric Hydroxide - A New Adsorbent for the Removal of Arsenic from Natural Water," J. Water SRT - Aqua, Al: 1:30-35.
Edwards, M.A (1994). 'Chemistry of Arsenic Removal During Coagulation and Fe-Mn Oxidation," J. AWWA, September 1994, pp. 64-77.
Taylor II (1998). "Considerations in Arsenic Analysis and Speciation," J. AWWA, 90:3:103.
Hayes (1980). "Removal of Arsenic from Contaminated Drinking Water by Chitosan/Chitin Mixture," Water Research, 14:1307.
EPA (1989). SAB Review of Arsenic Issues Relating to the Phase II of Proposed Regulations from the ODW. EPA SAB-EHC-89-038.
EPA (1992). Review of ORD's Arsenic Research Recommendations. EPA SAB-DWC-92-018.
EPA (1994). Review of the Draft Drinking Water Criteria Document on Inorganic Arsenic, EPA