US EPA 2000t. Arsenic Technologies and Costs for the Removal of Arsenic from Drinking Water. December 2000. 272 pages [W-99-16-III-B-176]
Other documents for the same rulemaking (all, by stage)
References: 176 extracted, 0 linked to papers
TDS/As Ratio: NR 2,800 Hathaway and Rubel (1987)
Fox (1989) lonac ASB-1 - and Dowex 11 Bed Volume: 0.014 cu ft Flowrate: NR
TDS/As Ratio: 9200:1 400-500 [projected if As(III) is oxidized to As(V)] Clifford and Lin (1985) • A-300E (bench-scale) • A-300E (full-scale) Bed Volume: 0.0018 cu ft Flowrate: 0.035 gpm
NR = Not Reported Another approach for minimizing effluent levels is to operate IX columns in "counter-current flow" operation. In this mode, feed water is applied in one direction (e.g., downward) and the regenerant is applied in the opposite direction (e.g., upward). This minimizes leakage from the column. Typically columns are designed for "co-current flow" operation where the feed water and regenerant are applied in the same direction. Co-current operation increases chances for leakage, 2-25 P.43 however, since regeneration in this mode concentrates the contaminant on the effluent end of the IX column. Using the "counter-current flow" method also minimizes regenerant requirements, i.e. volume and concentration (EPA. 1995). 2.4.6 Secondary Effects Chloride-form resins are often used in arsenic removal. Chloride ions are displaced from the column as contaminants (arsenic) are sorbed onto the column. As a result, the potential exists for increases in the chloride concentration of the product water. Increases in chlorides can greatly increase the corrosivity of the product water. Chlorides increase the corrosion potential of iron and as a result increase the potential for red water problems (EPA, 1995). Corrosion problems are worsened when high chloride levels are intermittent. In situations where chlorides pose a problem, post-treatment corrosion control, demineralization, blending, or alternate treatment techniques may be required.
EBCT A few studies have been performed to test the effect of EBCT on IX performance. Clifford and Lin (1986) reduced EBCT from 5 to 1.4 in a Hanford, GA study and found no significant reduction in arsenic removal performance. In a recent AWWARF study, four IX columns were run with EBCTs varying between 2.5 and 15 minutes. Data from this study show that the shorter the
EBCT, the more BV can be treated before breakthrough. The disadvantage to shorter EBCT, however, is increased regeneration frequency. Based on these data, shorter EBCTs may be preferred to reduce capital costs (AWWARF, 1998). 2.4.11 Field Studies Anion exchange processes have demonstrated the capacity to consistently reduce arsenic concentrations below 3 /ug/L. The Battelle Memorial Institute, with funding from EPA, studied two ion exchange plants located in New England. (Wang, 2000) The treatment train of one of the plants consisted of a potassium permanganate greensand oxidizing filter followed by a mixed bed ion exchange system. This system was regenerated every 6 days and consistently reduced influent arsenic concentrations of 40 to 65 /ug/L to below 5 /ug/L. Indeed, this system was able to produce finished water with arsenic concentrations below 3 /ug/L for approximately 30 weeks. The treatment train of the second plant also incorporated pre-oxidation, consisting of a solid oxidizing media filter followed by an anion exchange system. However, although the influent arsenic concentrations facing this system (19 to 55 Mg/L) were not as great as those handled by the other ion exchange system involved in this study, effluent arsenic concentrations for this plant were not maintained at a consistently low level, ranging from below 5 /ug/L to more than 80 /ug/L.
Nonetheless, based on the breakthrough data collected during this study, the second system could feasibly achieve finished water levels of 5 /ug/L, or even 3 /ug/L, if it was regenerated with greater frequency (i.e., every 3 to 4 weeks). 2-28 This study also demonstrated that ion exchange has only a minimal impact on water pH when used to treat for arsenic. Following treatment, the average pH of one of the two plants was identical to the average influent pH (pH 7.5). while the average pH of the effluent from the second plant was only slightly below that of the influent (pH 7.3 and pH 8.3, respectively). Blending a treated portion with an untreated portion would reduce any impact on finished water pH. 2.4.12 Typical Design Parameters Through extensive research, Clifford and others (1998) assembled typical operating parameters and suggested options for ion exchange processes. Although many design parameters must be tailored to the specific treatment situation, Table 2-2 gives typical values and options.
MEMBRANE PROCESSES 2.5.1 Introduction Membranes are a selective barrier, allowing some constituents to pass while blocking the passage of others. The movement of constituents across a membrane requires a driving force (i.e. a potential difference between the two sides of the membrane). Membrane processes are often classified by the type of driving force, including pressure, concentration, electrical potential, and 2-29 P.47 temperature. The processes discussed here include only pressure-driven and electrical potentialdriven types. Pressure-driven membrane processes are often classified by pore size into four categories: microfiltration (MF), ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO). Typical pore size classification ranges are given in Figure 2-1. High-pressure processes (i.e., NF and RO) have a relatively small pore size compared to low-pressure processes (i.e., MF and UF). Typical pressure ranges for these processes are given in Table 2-3. NF and RO primarily remove constituents through chemical diffusion (Aptel and Buckley, 1996). MF and UF primarily remove constituents through physical sieving. An advantage of high-pressure processes is that they tend to remove a broader range of constituents than low-pressure processes. However, the drawback to broader removal is the increase in energy required for high-pressure processes.
Fox,1989 Fox and Sorg. 1987 3-5 gpd 67% recover}' 195 psi below MDL
Fox. 1989 Fox and Sorg. 1987 Fairbanks, AL low-pressure (< 100 psi)
Fox. 1989 Fox and Sorg, 1987 San Ysidro, NM Pilot (hollow fiber, cellulose acetate) 50% recovery pH adjustment to 6.3 antiscalent addition 93-99% Clifford and Lin, 1991 San Ysidro, NM Pilot (hollow fiber, polyamide) 50% recovery pH adjustment to 6.3 antiscalent addition Clifford and Lin. 1991 San Ysidro, NM 10-15% recover.'
Fox. 1989 Fox and Sorg. 1987 Tarrytown. NY Pilot (FilmTec BW30, Hydranautics NCM1. Fluid Systems TCFL) 15 gfd 10% recovery below MDL
Malcolm Pirnie. 1992 Tarrytown, NY Not Available
Rogers. 1989 Charlotte Harbor. (several membrane types) As(V) 96-99% As(III) 46-84%
Huxstep. 1987 Cincinnati, OH Not Available As(III)73% Fox and Sorg. 1987 Hudson. NH Not Available
DK.2540F Lake Water DK2540F Deionized DK.2540F Lake Water Deionized Membrane Single Element Flat Sheet DK2540F These results indicate very high rejection for As(V) but very low rejection for As(III) at neutral pH. Again, this points to the fact that oxidation conditions would be desirable, and that surface charge/electrostatic repulsion probably plays a role in arsenic rejection. Also, flat sheet testing produced a rejection rate comparable, and slightly conservative, to the single element rejection rate. Several RO pilot-scale tests were also performed (AWWARF, 1998). Two tests were performed on high- and low-DOC groundwaters. Another set of tests was performed on spiked, finished surface water. The results from these pilot tests are summarized in Table 2-11. Table 2-11 shows substantial rejection for both the low- and high-DOC waters. Rejection was only slightly higher with the high DOC water. As with UF and NF, flux and recovery changes did not seem to affect arsenic rejection. Results for the four membranes tested on spiked finished water also showed substantial removal. For all membranes during this test, As(V) exceeded 95 percent, however, As(III) rejection averaged only 74 percent. 2-41 P.59
ENR Materials Prices 2189.24 '" BLS numerical values were re-based to 1967 base year (see Section 3.2.5) Table 3-8 Unit and General Cost Assumptions Electricity1 $0.08/kWh Diesel Fuel1 $1.25/gallon Natural Gas1 $0.006/scf Labor Large systems: Small systems: Building Energy Use 102.6 kWh/ft7yr Energy Information Administration. $40/hr $28/hr P.78
Brandhuber (1998). "Arsenic Rejection by Nanofiltration and Ultrafiltration Membranes: Arsenic Forms vs. Membrane Properties," AWWA Inorganic Contaminants
Workshop, San Antonio, TX, February 23-24, 1998.
Buckley (1996). "Categories of Membrane Operations," Chapter in Water Treatment Membrane Processes. McGraw Hill, 1996. American Water Works Research
Foundation, Lyonnaise des Eaux, Water Research Commision of South Africa, 1996.
AWWA (1990). Water Quality and Treatment - A Handbook of Community Water Svstems. McGraw-Hill Publishing Company, New York.
AWWA (1997). Arsenic Regulation. USEPA, Office of Ground Water and Drinking Water, October 1997.
AWWA (1999).. Water Quality and Treatment - A Handbook of Community Water Supplies. Fifth Edition. McGraw-Hill Publishing Company, New York. 1999.
AWWARF (1996) - Water Treatment Membrane Processes. McGraw-Hill Publishing Company, New York.
AWWARF (1998). Arsenic Treatability Options and Evaluation of Residuals Management Issues.
Amy, G.L., M. Edwards, M. Benjamin, K. Carlson, J. Chwirka, P. Brandhuber, L. McNeill and F. Vagliasindi, Draft Report, April 1998.
AWWARF (2000). Arsenic Treatability Options and Evaluation of Residuals Management Issues,
Amy, G.L., M. Edwards, M. Benjamin, K. Carlson, J. Chwirka, P. Brandhuber, L. McNeill and F. Vagliasindi. AwwaRF. Denver, CO. 2000.
Bellack, E. (1971). "Arsenic Removal from Potable Water," J. AWWA, 63:7:454-458.
Bennett (1996). "Sorption and Filtration of Metals Using Iron-Oxide Coated Sand," Water Research, 30:11:2609.
Bennett (1998). "Sorption of Arsenic by Various Adsorbents," AWWA Inorganic Contaminants Workshop, San Antonio, TX, February 23-24, 1998. Cadmus Group, Inc. (1998). Cost Evaluation of Small System Compliance Options - Point-of-Use and Point-of-Entry Treatment Units. Prepared for USEPA Office of Ground Water and Drinking Water.
CH2M Hill (1998). Telephone conversation with Joseph Chwirka, CH2M Hill, Albuquerque, New P.86 Mexico.
Ruiz (1994). "Removal of Arsenic by Enhanced Coagulation and Membrane Technology," Proceedings AWWA Annual Conference, New York.
Edwards (1998). "Raw Water Quality and Arsenic Treatment." Submitted for Publication in,/. AWWA.
Edwards (1996). "Speciation of As in US Waters." Poster Session AWWA Annual
Yang (1994). "Arsenic Species in Groundwaters of the Blackfoot Disease Area, Taiwan," Environmental Science and Technology, 28:5:877.
Beuhler (1994). "Enhanced Coagulation for Arsenic Removal," J. A WW A, 9:79-90.
Chow (1983). "As (III) and As (V) Separation by Chloride-Form Ion Exchange Resins," Proceedings AWWA WQTC, Norfolk. Virginia.
Lin (1985). Arsenic (III) and Arsenic (V) Removal From Drinking Water in San Ysidro. New Mexico. University of Houston, Houston, Texas.
Lin (1986). Arsenic Removal From Groundwater in Hanford, California - A Preliminary Report. University of Houston, Department of Civil/Environmental Engineering. Cited in: AWWA (1990). Water Quality and Treatment - A Handbook of Community Water Svstems. McGraw-Hill Publishing Company, New York.
Clifford, D. (1995). "Computer Prediction of Arsenic Ion Exhange," J. AWWA, 86:4:10.
Lin (1995). "Ion Exchange, Activated Alumina, and Membrane Processes for Arsenic Removal from Groundwater," Proceedings of the 45th Annual Environmental Engineering Conference, University of Kansas, February 1995.
Clifford, D.A. G. Ghurye et al. (1997). Final Report: Phases 1 & 2 City of Albuquerque Arsenic Study Field Studies on Arsenic Removal in Albuquerque. New Mexico using the University of Houston/EPA Mobile Drinking Water Treatment Research Facility. Houston, TX: University of Houston, December 1997.
Tripp (1998). "Arsenic Removal by Ion Exchange With and Without Brine Reuse," AWWA Inorganic Contaminants Workshop, San Antonio, TX, February 2324, 1998.
Clifford, D.A. G. Ghurye et al.(1998) Final Report: Phase 3 Citv of Albuquerque Arsenic Study P.87 Field Studies on Arsenic Removal in Albuquerque. New Mexico using the University of Houston/EPA Mobile Drinking Water Treatment Research Facility. Houston, TX: University of Houston, August 1998. Cooperative Research Centres for Waste Management and Pollution Control Limited (1999). "Photo-Oxidation and Removal or Arsenic from Acid Mine Water: A Pilot Demonstration of CRC Process in Montana, USA," CRC for Waste Management and Pollution Control Ltd.,
Kensington, NSW 2033, Australia. Culp/Wesner/Culp (1979). Estimating Water Treatment Costs, Volume 2: Cost Curves Applicable to 1 to 200 mgd Treatment Plants, CWC Engineering, San Clemente, California. Culp/Wesner/Culp (1984). Estimation of Small System Water Treatment Costs. CWC Engineering Software (for USEPA), San Clemente, California. Culp/Wesner/Culp (1994). WATERCO$T Model - A Computer Program for Estimating Water and Wastewater Treatment Costs (Version 2.0). CWC Engineering Software, San Clemente, California.
Tikkanen (1994). "Nationwide and California Arsenic Occurrence Studies," Published in Arsenic Exposure and Health, Chapman and Hall Publishing Company, pp. 31-40.
DPRA, Inc. (1993a). Small Water System Byproducts Treatment and Disposal Cost Document, Prepared for USEPA Office of Ground Water and Drinking Water.
DPRA, Inc. (1993b). Water System Byproducts Treatment and Disposal Cost Document, Prepared for USEPA Office of Ground Water and Drinking Water.