USEPA (1991b). Optimizing Water Treatment Plant Performance Using the Composite Correction Program. EPA/625/6-91/027. 209 pp. [IESWTR-NOA-IX-B-123]
Other documents for the same rulemaking (all, by stage)
References: 27 extracted, 0 linked to papers
10. Renner, R.C, B.A. Hegg, and D.L. Fraser. 1989. Demonstration of the Comprehensive Performance Evaluation Technique to Assess Montana Surface Water Treatment Plants. Presented at the 4th Annual
ASDWA Conference, Tucson, Arizona. February. 11. U.S. EPA. 1990. EPA Summary Report: Optimizing Water Treatment Plant Performance with the Composite Correction Program. EPA 625/8-90-017. U.S. EPA Center for Environmental Research Information. March. •When an NTIS number is cited in a reference, that reference is available from: National Technical Information Service 5285 Port Royal Road
Water Treatment Plant Design. 1990. American Society of Civil Engineers and American Water Works Association, McGraw-Hill, 2nd ed. 2. Water Treatment Principles and Design. 1985.
3. Sanks, R.L., ed. 1978. Water Treatment Plant Design for the Practicing Engineer. Kent, England: Ann Arbor Science Publishers. Process Controllability/Flexibility - Design (B). The filter rate controllers were malfunctioning, causing periodic increases in filtered water turbidity. The plant had no capability of feeding a filter aid. U.S. EPA. 1990. EPA Summary Report: Optimizing Water Treatment Plant Performance with the Composite Correction Program. EPA 625/8-90/017. U.S.
Regli, S. 1990. Hows and Whys of CTs. Presented at
AWWA Annual Conference, Cincinnati, OH. June. U.S. EPA. 1989. Guidance Manual for Compliance with the Filtration and Disinfection Requirements for Public Water Systems Using Surface Water Sources. Science and Technology Branch, Criteria and Standards Division, Office of Drinking Water. NTIS No. PB90148016. Washington, DC: U.S. EPA.
Hibler, C P . and C M . Hancock. 1990. Waterborne Giardiasis. In: Drinking Water Microbiology Progress and Recent Developments. New York:
Springer-Verlag, Inc. U.S. EPA. 1989. Surface Water Treatment Rule. Federal Register, Vol. 54, No. 124, U.S. Environmental Protection Agency, 40 CFR, Parts 141 and 142, Rules and Regulations, Filtration/Disinfection. June. Assessing Applicability of a CCP The most serious of the performance-limiting factors identified were process control oriented. The evaluation of major unit processes resulted in a Type 3 rating at the present peak instantaneous operating flow. However, it was determined that the rating could be upgraded to Type 1 if the plant peak instantaneous operating flow rate could be reduced by operating for longer periods of time each day. This adjustment will require addressing the plant coverage factor by convincing administrators to allow operators to spend additional time at the treatment facility. If plant flow can be reduced and operator coverage increased, it appears that the utility would be able to achieve improved performance through implementation of a followup CCP. This recommendation should be made to the city council. Documentation of improved performance may be difficult because existing monitoring data do not reflect true past performance.
CPE Results The success of conducting CPE activities can be measured by plant administrators selecting an approach and implementing activities to achieve the required performance from their water treatment facility. If definite followup activities are not initiated within a reasonable timeframe, the objectives of conducting a CPE have not been achieved. Ideally, followup activities must comprehensively address the combination of factors identified (e.g., implement a CCP) and should not be implemented in a piecemeal approach. In the previous example, plant administrators decided to hire an operations consultant to implement a CCP. The CCP addressed the identified factors and resulted in the existing plant achieving SWTR requirements without major capital improvements. 11. Safe Drinking Water Notes from Pennsylvania Department of Environmental Resources. 1990. Division of Water Supplies, Harrisburg, PA. August.
12. Cleasby, J.L., M.M. Williamson, and E.R. Baumann. 1963. Effect of Filtration Rate Changes on Quality. Journal AWWA. 55:869-878.
13. Cleasby, J.L., A.H. Dharmarajah, G.L. Sindt, and E.R. Baumann. 1989. Design and Operation Guidelines for Optimization of the High Rate Filtration Process: Plant Survey Results. Denver, CO: AWWA Research Foundation and AWWA. September. P.42
4. Hudson, H.E. and J.E. Singley. 1974. Jar testing and utilization of jar test data. In: Upgrading Existing Water Treatment Plants. AWWA Seminar Proceedings, VI-79. June. 5. U.S. EPA. 1990. EPA Summary Report: Optimizing Water Treatment Plant Performance with the Composite Correction Program. EPA 625/8-90/017. U.S.
6. Renner, R.C, B.A. Hegg, and D.L. Fraser. 1989. Demonstration of the Comprehensive Performance Evaluation to Assess Montana Surface Water Treatment Plants. Presented at the 4th Annual ASDWA
Conference, Tucson, Arizona. February. 7. Water Rates (M1). 1983. AWWA Reference Manual Series. No. 30001. Denver, CO: AWWA. 8. Water Rates and Related Charges (M25). AWWA Reference Manual Series. No. 30026. Denver, CO: AWWA.
Service. 1986. AWWA Seminar Proceedings. No. 20001. Denver, CO: AWWA. P.59
10. Developing Water Rates, 1973. AWWA Seminar Proceedings. No. 20124. Denver, CO: AWWA. 11. Water Rates: An Equitability Challenge. 1983. AWWA Seminar Proceedings. No. 20172. Denver, CO: AWWA.
17. Hibler, CP. Protocol - Sampling Water for Detection of Waterborne Particulates, Giardia, and Cryptosporidium, Fort Collins, CO: CH Diagnostic & Consulting Service, Inc. 12. Process Applications, Inc. 1990. Summary Report Loma, Montana Water Treatment Plant Composite Correction Program. Unpublished report. December. 18. U.S. EPA. 1989. Guidance Manual for Compliance with the Filtration and Disinfection Requirements for Public Water Systems Using Surface Water Sources.
13. Prendiville, P.W. 1984. Ozonation of the 900 cfs Los Angeles Water Purification Plant. Presented at the
14. Cleasby, J.L., M.M. Williamson, and E.R. Baumann. 1963. Effect of filtration rate on quality. Journal
Novembers, 1990. P.60 CHAPTER 4 FINDINGS FROM FIELD WORK Further efforts, which include additional onsite activities, are being conducted to allow refinement of the handbook techniques. Table 4-1 provides information on the plants that have been evaluated. Ten of the plants were in Montana, three each were in Maryland and West Virginia, two each were in Ohio and Kentucky, and one was in Pennsylvania. The plants had a wide range of peak operating flow rates, but were generally serving small to medium-sized communities. All used surface water for their raw water source. Most of the plants utilized conventional unit
2. Cleasby, J.L., A.H. Dharmarajah, G.L. Sindt, and E.R. Baumann. 1989. Design and Operation Guidelines for Optimization of the High-Rate Filtration Process: Plant Survey Results. ISBN 0-89867-478-6.
EPA. 2. Renner, R.C, B.A. Hegg, and D.F. Fraser. 1989. Demonstration of the Comprehensive Performance Evaluation Technique to Assess Montana Surface Water Treatment Plants. Phoenix, AZ: Association of State Drinking Water Administrators Conference. 3. U.S. EPA. 1989. Guidance Manual for Compliance with the Filtration and Disinfection Requirements for Public Water Systems Using Surface Water Sources.
APPENDIX F Sample Special Study P.79 April 4,1989
CCP is that it optimizes the capability of existing facilities without the expense of major capital improvements. The state initiated a program to evaluate and demonstrate the effectiveness of the CCP approach at small water treatment facilities using surface water supplies (2). The state hired a consultant to develop and implement the approach. As part of this project, a CPE was conducted at water treatment Plant No. 5 in August 1988. The CPE revealed that the plant had some performance problems and that the top ranked factors identified were process control related. It was felt that operator training, conducted as a portion of a CCP, would improve plant performance. This report summarizes the results of the
CCP, which was initiated in April 1989. 1. Operator Application of Concepts and Testing to Process Control - Operation The plant had no formal process control program to provide information from which operational decisions could be made. Although the operators had a good understanding of water treatment, they were not applying their knowledge to operation of the plant. Because of the highly variable raw water quality, it was essential that the plant be monitored continuously
2. Renner, R.C, B.A. Hegg, and D.L. Fraser. 1989. "Demonstration of the Comprehensive Performance Evaluation Technique to Assess Montana Surface Water Treatment Plants," Presented at 4th Annual Association of State Drinking Water Administrators
Conference, Tucson, AZ. 3. U.S. EPA. 1989. Surface Water Treatment Rule. Federal Register, Vol. 54, No. 124, U.S. Environmental Protection Agency, 40 CFR, Parts 141 and 142, Rules and Regulations, Filtration/Disinfection, June. • U S COVtRNMENT PRINTING OFlHCt 1 9 9 3 - 7 5 0 - 0 0 2 / 80281