ATSDR. 1996a. Toxicological Profile for 1,2-Dichloroethene. U.S. Department of Health and Human Services, Public Health Service. 195 pages Available on the Internet at: http://www.atsdr.cdc.gov/toxprofiles/tp87.html [W-01-14-I-B-3]
Other documents for the same rulemaking (all, by stage)
References: 195 extracted, 0 linked to papers
Rochester, MN, municipal landfill 470 (mean) Brown and Donnelly 1988
Rochester, MN, municipal landfill trans 88 (mean) Brown and Donnelly 1988
Wisconsin, 20 municipal and industrial landfills 1985-1987 Detected in leachate from 8 of 26 sites Friedman 1988 Aqueous lagoon Forest Waste Disposal site in Otisville, Ml trans
EPA 1986b Urban storm water runoff 15 U.S. cities as of July 1982 trans 1-3 (in positive samples) Detected in runoff from Little Rock,
AR, and Eugene, OR Cole etal. 1984 Waste water Los Angeles, CA 5.2 (mean) Effluent from a county sewage treatment plant Gossett et al. 1983 1980/1981 trans untreated: 52-60 effluent: 31-43 Municipal sewage treatment plant; detected in 5 of 5 samples Lao etal. 1982
Chicago, IL trans Effluent from a municipal sewage treatment plant Lue-Hing et al. 1981 trans 20 (max.) Treated effluent from a petroleum refinery Snider and Manning 1982
Owensboro, KY August 1975 Chemical plant effluent
EPA 1976 Calvert City, KY October 1975 Chemical plant effluent
EPA 1976 Table 5-3. Water Monitoring Data for 1,2-Dichloroethene (continued) Media • Location United States Sampling date United States Isomer Concentration (PPb) trans trans 10 (max.) 46 (max.) Industry: coal mining electrical electronic components trans trans 10 (max.) 10 (max.) foundries pharmaceutical manufacturing trans 75 (max.) Waste water (cont.) Comments
EPA 1980d Shackelford et al. 1983 Shackelford et al. 1983 Shackleford et al. 1983 Table 5-3. Water Monitoring Data for 1,2-Dichloroethene (continued) Media Location Sampling date
UCLA campus, Los Angeles, CA ND = Not detected; NS = Not stated 3/26/82 19.0 (median) [detected in 1 sample (cis) and 2 samples (trans)] trans 60.6 auto and other laundries (detected in 1 sample) trans explosives (detected in 1 sample) trans 140.7 (medium) electronics (detected in 7 samples) trans 13.7 (median) mechanical products (detected in 2 samples) transportation equipment (detected in 1 sample) Shackelford et al. 1983 publicly owned treatment works (POTW)(detected in 63 samples) Shackelford et al. 1983
EPA 1980b trans 29.3 trans 16.3 (median) trans 260 (mean) 1700 (max) metal finishing trans 2200 (max) photographic equipment/supplies trans 75 (mean) 260 (max) non-ferrous metal manufacturing trans 150 (mean) 290 (max) rubber processing 0.230 1 sample Reference
OSURE Rain water trans Comments Isomer POTEr Waste water (cont.) Concentration (PPb) Kawamura and Kaplan 1983 P.20 1,2-DICHLOROETHENE
5. POTENTIAL FOR HUMAN EXPOSURE 96% of VOCs such as cis-1,2-dichloroethene (Clark et al. 1988; Lee et al. 1988; Stenzel and Gupta 1985). In a comprehensive survey of United States drinking water derived from groundwater, 16 of 466 randomly selected sites and 38 of 479 purposely selected sites contained 1,2-dichloroethene. The maximum concentration was 2 ppb at random sites and 120 ppb at the nonrandom sites (Westrick et al. 1984). Trans-1,2-dichloroethene was found in Miami, Florida, drinking water at 1 ppb. Cis-1,2-dichloroethene was found in Miami drinking water at 16 ppb; and in Cincinnati, Ohio, and
Philadelphia, Pennsylvania, drinking water at 0.1 ppb; but was not detected in 7 other drinking waters surveyed (EPA 1980d). In a four-city study (Cincinnati, Ohio; St. Louis, Missouri; Atlanta, Georgia; Hartford, Connecticut) to determine the major source type of priority pollutants in tap water and POTW influents, it was found that 43, 38, and 28% of commercial sources, industrial sources, and POTW influents, respectively, contained trans- 1 ,2dichloroethene (EPA 198 lc). The average concentrations from the industrial sources were between 10 and 100 ppb while the others were <10 ppb. Industrial effluent monitoring data from Shackelford et al. (1983) was obtained from a database of a comprehensive EPA survey of 4,000 effluent samples from industries and POTWs. This survey was conducted in response to the consent decree between the National Resources Defense Council and the EPA on June 7, 1976. Data from this study are presented in Table 5-3. Over the last decade, the Safe Drinking Water Act has focussed attention on improved controls over
VOC contamination (including 1,2-dichloroethene) of community drinking water systems. Based on available national statistics, 1,2-dichloroethene has been found in detectable concentrations at less than 5% of the community systems using surface water sources. The figures jumped to 21%, however, for community systems relying on groundwater (Coniglio et al. 1980). No comparable figures are available for noncommunity systems, such as truck stops or highway convenience stores in rural areas, or for domestic groundwater wells. 5.4.3 Sediment and Soil Available data on 1,2-dichloroethene in soil are limited to those obtained through hazardous waste site monitoring (Aldis et al. 1983; EPA 1986c, 1987a; Pennington 1983; VIAR 1987). Soil gas pollutants P.21 1,2-DICHLOROETHENE
5. POTENTIAL FOR HUMAN EXPOSURE in a shallow, unconfined aquifer receiving waste water from metal-plating operations at Picattinny Arsenal in Morris County, New Jersey, were found to have a maximum cis-1,2-dichloroethene concentration of 33 ppb in the vadose zone (Smith 1988). 1,2-Dichloroethene has been detected, but not quantified, in sediment samples at Love Canal, New York (HSDB 1995). Recent summaries related to data on l,2dichloroethene in sediments have not been located. In the early 1980s 1,2-dichloroethene was found at a concentration of >5 ppb (wet weight) in sediment at 4% of 361 stations reported in EPA's STORET database (Staples et al. 1985). No further summary information was located on the occurrence of 1,2-dichloroethene in sediments. EPA is in the process of consolidating all available information on toxics in sediments to comply with provisions of the Water Resources Development Act of 1992. This will lead to the creation of a National Sediment
Inventory, which should eventually facilitate custom data retrievals and encourage research studies to analyze available sediment monitoring results (EPA 1993). 5.4.4 Other Environmental Media Trans-l,2dichloroethene concentrations ranging from 22 to 55 g/L have been detected in municipal sludge from various treatment plants throughout the United States (Feiler et al. 1980; Nay lor and Loehr 1982). Few reports exist of 1,2-dichloroethene in biota from U.S. waters. This is because 1,2-dichloroethene is not a typical biota contaminant (Staples et al. 1985). Nicola et al. (1987) reported mean and maximum l,2dichloroethene levels of 0.04 and 0.05 ppm, respectively, in fish tissue from Commencement Bay in Tacoma, Washington. No fish obtained at the 95 stations in EPA's STORET database contained detectable levels of 1,2-dichloroethene (Staples et al. 1985). A BCF of 6 was estimated for fathead minnows (ASTER 1995) using the method of Veith and Kosian (1983). Using a log octanol/water partition coefficient of 2.06 for trans-1,2-dichloroethene and a recommended regression equation (Lyman et al. 1982), a BCF of 22 has been estimated (HSDB 1995). Based on these estimated BCFs, 1,2-dichloroethene is not expected to bioaccumulate to any appreciable extent. P.22 1,2-DICHLOROETHENE
5. POTENTIAL FOR HUMAN EXPOSURE Firefighters and workers at landfill sites may also be exposed to l,2dichloroethene (Michal 1976;
NIOSWOSHA 1978; Vogt and Walsh 1985). No information was located on exposure levels in other occupational settings. 5.6 POPULATIONS WITH POTENTIALLY HIGH EXPOSURES Other than individuals who are occupationally exposed, populations with potentially high exposure include those living near production and processing facihties, hazardous waste sites, municipal waste water treatment plants, and municipal landfills. Near production and processing facihties, certain hazardous waste sites, and municipal landfills, potential exists for exposure to elevated levels of dichloroethene in air downwind of the sites and in contaminated drinking water from groundwater downgradient of the sites. Potential exposure levels cannot be estimated with the data available. 5.7 ADEQUACY OF THE DATABASE Section 104(i)(5) of CERCLA, as amended, directs the Administrator of ATSDR (in consultation with the Administrator of EPA and agencies and programs of the Pubhc Health Service) to assess whether adequate information on the health effects of 1,2-dichloroethene is available. Where adequate information is not available, ATSDR, in conjunction with the NTP, is required to assure the initiation of a program of research designed to determine the health effects (and techniques for developing methods to determine such health effects) of 1,2-dichloroethene. The following categories of possible data needs have been identified by a joint team of scientists from
Production, Import/Export, Use, Release, and Disposal. According to the Emergency Planning and Community Right-to-Know Act of 1986, 42 U.S.C. Section 11023, industries are required to submit substance release and off-site transfer information to the EPA. The Toxics Release Inventory (TRI), which contains this information for 1993, became available in 1995. This database will be updated yearly and should provide a list of industrial production facilities and emissions. Exposure Levels in Environmental Media. Rehable monitoring data for the levels of l,2dichloroethene in contaminated media at hazardous waste sites are needed so that the information P.27 1,2-DICHLOROETHENE
GC/HECD 50 pg 93.3±12.4a(adipose) 53.4±2.4a(kidney) 62.6±2.6a (brain) Lin etal. 1982 Blood Heat in a closed vial
GC/FID No data No data Uehorietal. 1987 Blood Mix with water; heat in a closed vial at 40 °C; headspace analysis
GC/MS 10-20 pg No data Hara et al. 1980 Blood Purge and trap with antifoaming agent; thermal desorption
GC/MS 20 ppt Ashley etal. 1992 Blood, urine, solid tissue Sample in sealed vial heated to 65 °C; headspace analysis
GC/FID GC/ECD No data No data Streete et al. 1992 Body tissue Homogenize and mix tissue with water; heat in a closed vial at 40 °C; headspace analysis
GC/MS 10-20 pg No data Hara et al. 1980 Portable spirometer into canisters
GC/MS Breath No data 99 (trans) 90 (cis) Raymer et al. 1990 For trans-1,2-dichloroethene
6. ANALYTICAL METHODS identification of 1,2-dichloroethene in biological materials. A combination of detectors enabled Streete et al. (1992) to determine dichloroethenes in the headspace of blood, urine, and solid tissues. Dichloroethenes in breath can be determined by GUMS after collection with a portable spirometer (Raymer et al. 1990). In this approach, recoveries exceeded 90% for the dichloroethene isomers. The detection limit for dichloroethenes in human blood has been extended to part-per-trillion levels by Ashley et al. (1992), using an automated purge and trap technique that suppresses sample foaming with an antifoaming agent. High resolution GUMS can be used to enhance the contaminant separation abilities of gas chromatography on blood samples (Ashley et al. 1992; Bonin et al. 1992). 6.2 ENVIRONMENTAL SAMPLES Analytical methods for determining cis- and trans- 1,2 dichloroethene in environmental samples are presented in Table 6-2. Analysis of 1,2 dichloroethene in workplace air samples can be determined by
NIOSH 1987 Stainless steel canister (modified
EPA method TO-14) GC/MS 0.3 ppb (cis) No data McClenny et al. 1991 Gas sampling loop Fast GC/FID 4.3 ppb (cis) No data K e e t a l . 1992b Drinking water Purge and trap onto adsorbent; backflush to cryogenically-cooled trap
GC/HECD 0.002 pg/L 80+7 EPA 1986e Automated purge and trap; thermal desorption
GC/FID Drinking water No data 'Charcoal tube collection and CS 2 desorption Drinking water 16 ppm No data Ho e t a l . 1989 100 (cis) 92 (trans) Eichelberger et al. 1990 0.01 pg/L (trans)3 0.03 pg/L (cis)a 100 (trans) 99 (cis) Kessels et al. 1992 Water Purge and trap; thermal desorption
APHA/AWWAAVEF 1992 (Standard Methods) Water Purge and trap onto adsorbent; thermal desorption
APHA/AWWAA/VEF 1992 (Standard Methods) Water Flow injection
MIMS (uses ion trap MS) 0.5 ppt (trans) No data Bauer and Solyom 1994; Soni et al. 1995
EPA 1986 Groundwater, soil, sediment, solid waste Purge and trap onto adsorbent; thermal desorption
EPA 1986 Table 6-2. Analytical Methods for Determining 1,2-Dichloroethene in Environmental Samples (continued) Analytical method Sample detection limit Percent recovery Sample matrix Preparation method
6. ANALYTICAL METHODS EPA method 601 (purgeable halocarbons) and EPA method 524 (purgeables) describe analysis of 1,2-dichloroethene in municipal and industrial waste water (EPA 1982). In both methods, a 5 mL grab sample of water is connected to a purging chamber. This chamber allows an inert gas to bubble through the water sample; the gas flow is directed through an adsorbent tube. In EPA method 601, nitrogen or heliunus the purging gas, and the adsorbent column consists of two different adsorbents and a drying agent. In EPA method 624, helium is the purging gas, and the adsorbent column is made up of one adsorbent and a drying agent. The collected organics are liberated from the sorbent by heating the sorbent column while backflushing with an inert gas; these organics are then introduced into the gas chromatograph. EPA methods 601 and 624 were developed to analyze volatile priority pollutants. In EPA method 601, analysis by GC uses a Carbopack B column, a Poracil C column, and a HECD detector. In EPA method 624, analysis by GC uses a Carbopack B column and a mass spectrometer. Since trans-1,2-dichloroethene is a priority pollutant and cis- 1,2-dichloroethene is not, only the trans isomer is mentioned in this method.
EPA method 502.1 is used to analyze 1,2-dichloroethene in finished or raw source water (EPA 1986e). This method is similar to EPA method 601. However, once the compound has been purged from the water sample to the adsorbent tube, the compound is introduced to the gas chromatograph by rapidly heating the adsorbent tube, with no intermediate cryogenic trapping. Numerous researchers have applied modifications of the EPA methods to environmental samples.
EPA's Master Analytical Scheme (Michael et al. 1991) incorporates automated purge and trap and capillary chromatography into method 624 to achieve sensitivity of 1 ppb. Method 624 was compared to purgeable organic chloride analysis by Barber et al. (1992) and found to be superior by virtue of its contaminant identification capabilities. Eichelberger et al. (1990) modified method 524 by using a capillary column and an ion trap detector (ITD) to achieve detection levels below 200 ppt. Headspace sampling coupled with capillary GUMS offers a promising screening tool since it requires minimal sample preparation (Gryder-Boutet and Kennish 1988). Headspace GUMS can also been used for determining dichloroethenes in landfill leachate (Forst et al. 1989). Purge and trap methodology sometimes involves direct trapping of the bubbled compound cryogenically. Water contamination can become a problem in this method. The cryogenic trap described in EPA methods 601 and 624 is a specialized item and may not be adaptable to all gas P.34 1,2-DICHLOROETHENE
6. ANALYTICAL METHODS chromatographs. The considerations discussed above regarding use of different columns and detectors also apply here. The EPA guidelines for contract laboratories include methodology for water and soil sample analysis (EPA 1987c). The method listed in Table 6-2 is identical to EPA method 502.1 for the purpose of this discussion (except for the use of a mass spectrometer as the detector). The procedure for analyzing lowlevel contamination in soil is also similar to EPA method 502.1, except that the purging gas passes through a soil sample rather than a water sample. For higher-level soil contamination, the soil sample is first extracted with methanol. An aliquot of the extract is diluted with water; then the purge and trap methodology is followed. With respect to dichloroethene recoveries, Hewitt et al. (1991) found a headspace technique that is comparable to EPA SW-846 method 8240 for soil. It is practical for sample screening where contaminant identities were not required. The various SW-846 methods for 1,2dichloroethene presented in Table 6-2 are similar except for detection method.
6. ANALYTICAL METHODS exposure, and atmospheric exposure is likely to be of greatest concern to humans. However, the standardized methods for detecting 1,2-dichloroethene in air appear to be weak. For example, its detection limit of 16 ppm, outlined by the NIOSH technique (NIOSH 1987), is relatively high. Conversely, the stainless steel canister method of McClenny et al. (1991) purports to have a detection limit of 0.3 ppb and although not rigorously standardized, shows promise in detecting ambient background levels of 1 ,2dichloroethene. Information regarding the recovery efficiencies of the NIOSH (1987), McClenny (1991), and Ke et al. (1992b) procedures for detecting 1,2-dichloroethene in air were lacking. Additional data is needed to assess both accuracy and precision in the analysis of 1,2-dichloroethene in air. Contamination of surface water, groundwater, and foods in the vicinity of waste sites poses a threat to humans through oral exposure to l,2dichloroethene. Near quantitative recoveries and <.02 ppb detection limits were reported by Eichelberger et al. (1990). Low part-per-trilhon detection limits were reported by Kessels et al. (1992) and an 0.5 ppt detection limit was reported by Soni et al. (1995). These recoveries and detection limits for l,2dichloroethene in water, coupled with the specificity offered by capillary gas chromatography and selective detection used by these researchers provide a means for determining l,2dichloroethene at very low levels in water.
Currently, no viable method exists for determining 1,2-dichloroethene in food. The detection limit of 100 pg/kg reported by Page and Lacroix (1993) is at least two orders of magnitude higher than what is required to be comparable to existing air and water methods for 1,2-dichloroethene. Appreciable additional work is needed in this area. 6.3.2 Ongoing Studies The Environmental Health Laboratory Sciences Division of the National Center for Environmental
ATSDR has derived an MRL of 0.2 ppm for both acute-duratipn inhalation exposure (14 days or less) and intermediate-duration inhalation exposure (L-365 days) to trans- 1,2-dichloroethene based on a study by Freundt et al. (1977) that found fatty degeneration of the liver. The acute MRL is based on an LOAEL of 200 ppm over an 8-hour period, and the intermediate MRL is based on an LOAEL of 200 ppm for 8 hours per day, 5 days per week for 8 or 16 weeks.
ATSDR has derived oral MRLs for both acute- and intermediate-duration exposure. For acute oral exposure, data supported the derivation of an MRL for cis-1,2-dichloroethene of 1 mg/kg/day; however, no acute-duration MRL was derived for trans-1,2-dichloroethene. The acute oral MRL for cis-1,2-dichloroethene is based on a study by McCauley et al. (1990) that found hematological effects at 290 mgfkglday and reported a NOAEL of 97 mg/kg/day. Intermediate-duration oral exposure MRLs were derived for both the cis and trans isomers. The intermediate duration oral MRL for cis-1,2-dichloroethene is 0.3 mg/kg/day based on a hematological study (McCauley et al. 1990). For trans-1,2-dichloroethene, the intermediate oral MRL is 0.2 mg/kg/day, based on hepatic effects (Barnes et al. 1985).
EPA has given cis-1,2-dichloroethene a non-cancer rating or a "not classifiable" rating (D) (IRIS 1995). No National Toxicology Program (NTP) or IARC classifications exists.
OSHA requires employers of workers who are occupationally exposed to a mixture of trans- and cis-1,2-dichloroethene (CAS No. 540-59-O) to institute engineering controls and work practices to reduce exposure-to and maintain employee exposure at or below permissible exposure limits (PEL). The employer must use engineering and work practice controls, if feasible, to reduce exposure to or below an g-hour time-weighted average (TWA) of 200 ppm (790 mg/m3). Respirators must be provided during the time period necessary to install or implement feasible engineering and work practice controls (OSHA 1989). P.38 1,2-DICHLOROETHENE
7. REGULATIONS AND ADVISORIES 1,2-Dichloroethene is regulated by the Clean Water Effluent Guidelines as stated in Title 40, Section 400-475, of the Code of Federal Regulations. The point source category for which 1,2-dichloroethene is controlled as a Total Toxic Organic is electroplating (EPA 1981). The Resource Conservation and Recovery Act (RCRA) identifies 1,2-dichloroethene as a hazardous waste when it is discarded as a commercial chemical product, off-spec species, container residue, or spill residue (EPA 1980a). P.39 1,2-DICHLOROETHENE
EPA 1987 Treatment Standards Expressed as Waste Concentrations 0.054 mg/L (waste waters); 33 mg/kg (nonwaste waters) Land Disposal Restrictions: Appendix III List of Halogenated Organic Compounds Regulated Under 268.32 40 CFR 268